FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. KYE SYSTEMS CORP./
  3. FSUGG00A6

FSUGG00A6Wireless Stereo Earbuds

KYE SYSTEMS CORP.
Wireless Stereo Earbuds - FCC ID FSUGG00A6 - KYE SYSTEMS CORP.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 16, 2022
Application Purpose
Original Equipment
Date of Application
Jul 14, 2022
Equipment Note
Wireless Stereo Earbuds
Frequency Range
2402.00000000 - 2480.00000000
Company
KYE SYSTEMS CORP.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

KYE SYSTEMS CORP. Statement We KYE SYSTEMS CORP. Hereby Declare that The product Wireless Stereo Earbuds, models no. HS-M900BT, A2, HS-XXXXXX, HS-XXXXX, HS-XXXXXXX, HS-XXXXXXX, XX-XXXXX, XX-XXXXXX, XX-XXXXXXX, XX-XXXXXXXX (X can be 0-9 & A-Z & blank) are all identical in interior structure, electrical circuits and components, and just the model names are different for the marketing requirement. Your assistance on this matter is highly appreciated. Yours sincerely, Signature: <Signature>: Name:Ricky Chen Title:Section Supervisor

Attestation Statements

July 12, 2022 FCC ID : FSUGG00A6 Product Name: Wireless Stereo Earbuds The device has left and right earphones, the left and right earphones are electrically identical. <Signature>: Name:Ri cky Chen Title:Section Supervisor Applicant Company:KYE SYSTEMS CORP.

Cover Letter(s)

July 12, 2022 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: FSUGG00A6 Product Name: Wireless Stereo Earbuds Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Ricky Chen Title:Section Supervisor Applicant Company:KYE SYSTEMS CORP.

Cover Letter(s)

July Fede Auth 7345 Colu On o C, 1s Villa to ac that certi f defin labe For i beha for c Chon <Sig n Name Title: Applic 12, 2022 eral Commu horization & 5 Oakland M umbia, Mary our behalf, I st Floor, Blo ge, Nansha ct as our age submitted d fication is so ned in the Fe l identical to instances w alf, I acknow certification, ngxin Rd., S nature>: e:Ricky Ch Section Su cant Compa unications C Evaluation D Mills Road land 21046 appoint She ock B, Jun X n District, S ent in the pr documents p ought. I also ederal Comm o that submit where our au wledge that still resides Sanchong D hen upervisor any:KYE S ommission Division Author i enzhen Time Xiang Da Bui henzhen, C reparation of properly desc o certify that munications tted for appr uthorized ag all responsi with KY E ist., New Ta SYSTEMS C ity to Act as eway Testin ilding, Zhon hina (Name f this applica cribe the de each unit m s Commissio roval with th ent signs th ibility for com E SYSTEM aipei City 24 CORP. s Agent ng Laborator gshan Park of Agent co ation for equ evice or syst manufactured on’s regulatio his applicatio he applicatio mplying with MS CORP 160, Taiwan ries/ Zone C Road West ompany nam uipment cert em for which d, imported ons will hav on. on for certific h the terms . / No.492, n(R.O.C.) C, 1st Floor, t, Tong Le me and addr tification. I c h equipme n or marketed ve affixed to cation on ou and conditio Sec.5, Zone ress) ertify t d, as it a ur ons

External Photos

charger base Left earphone Right earphone

ID Label/Location Info

Size: 18mm*10mm HS-M900BT Genius FCC ID: FSUGG00A6

ID Label/Location Info

Label Location

Internal Photos

Left earphone Right earphone

RF Exposure Info

Acc eir whe pt gt E = d = Sop Ant Fie So <2. The ording to p = pt x re: = transmi = numeri c = electric = measurem t = (EXd) t gain = eld stre Pt={ [1 0 .79 mW n SAR eva o 447498 D gt = (EXd tter outp c gain of c field st ment dista 2 /30 x gt =-0.58dBi ngth =79 0 (79.85/20) aluation i RF Expo D04 Interi d) 2 /30 put power the tran s trength in ance in me i so Ant 9.85dBμV /10 6 x3 s not req osure eval im General in watts, smitting a n V/m, --- eters (m)- t numeri V/m @3m@2 ] 2 /(30x0 quired luation l RF Expos antenna (u - 10 ((dBuV ---3m ic gain= 2402MHz 0.875)} sure Guida unitless), V/m)/20) /10 6 0.875 x1000 mW ance v01 W = 0.033mW

Test Report

Report No.: TW2206386E File reference No.: 2022-07-09 Applicant: KYE SYSTEMS CORP. Product: Wireless Stereo Earbuds Model No.: HS-M900BT, A2, HS-XXXXXX, HS-XXXXX, HS-XXXXXXX, HS-XXXXXXX, XX-XXXXX, XX-XXXXXX, XX-XXXXXXX, XX-XXXXXXXX (X can be 0-9 & A-Z & blank) Trademark: Genius, AUOUA LIFE ON MUSIC Test Standards: FCC Part 15.249 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10 & FCC Part 15 Subpart C, Paragraph 15.249 regulations for the evaluation of electromagnetic compatibility Approved By Terry Tang Manager Dated: July 09, 2022 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2206386E Page 2 of 51 Date: 2022-07-09 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2017 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2206386E Page 3 of 51 Date: 2022-07-09 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ............................................................................................... 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty................................................................................................ 5 1.7 Test By......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results.................................................................................... 7 3.2 Test Standards................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test..................................................................... 8 5.1 Schematics of the Test....................................................................................... 8 5.2 Test Method and Test Procedure............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

Ricky Chen(Section Supervisor)
[email protected]+886-2-2995-6645Fax: +886-2-2999-9464

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from KYE SYSTEMS CORP.

Wireless Speaker - FCC ID FSUGG0AM - KYE SYSTEMS CORP.
FSUGG0AM

Wireless Speaker

Aug 20, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Keyboard - FCC ID FSUGKZI2 - KYE SYSTEMS CORP.
FSUGKZI2

Wireless Keyboard

May 23, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
FSUGMZN6

Wireless Mouse

Apr 20, 2026

Equipment Class

DTS - Digital Transmission System
FSUGMZN4

Wireless Mouse

Apr 03, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
FSUGMZN7

Wireless Mouse

Apr 01, 2026

Equipment Class

DTS - Digital Transmission System