GAO-SM6222Smart phone

Collage Investments LLC.
Smart phone - FCC ID GAO-SM6222 - Collage Investments LLC.
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jan 12, 2022
Application Purpose
Original Equipment
Date of Application
Jan 12, 2022
Equipment Note
Smart phone
Frequency Range
2575.00000000 - 2615.00000000
Company
Collage Investments LLC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

For more information about the warranty of your phone, after sales service and repair centers and/or a complete version of the User Guideplease visitwww.smoothmobile.us This mobile phone meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. Device type: Smooth(FCC ID: GAO-SM6222)6.26 Max has also been tested against this SAR limit. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHzSAR compliance for body-worn. operating configurations is limited to the specific configurations tested for this filingBody-worn operations . are restricted to belt-clipsholsters or similar accessories ,that have no metallic provide atcomponent in the assembly and must least the body1.0 cm separation between the device and of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure complianceThe. highest reported SAR for headbody-worn accessory ,, product specific(wireless router)and simultaneous , transmissionuseconditions is 0.116Wkg0.768Wkg /, /, 0768Wkgand 0.917Wkgrespectively./ / . 13.Absorption Rate (SAR) information: -07- 14. Warranty 1.Conoce tu teléfono 2.Inserte la tarjeta SIM y la tarjeta de memoria Huella dactilar Linterna Camara trasera Subir /bajar volumen Encendido / apagado Pantalla energía Conector USB Altavoz Cámara frontal -08- Tarjeta de memoria SIM1 SIM2 Huella dactilar Micrófono Altavoz 13.Información sobre la tasa de absorción (SAR): Este teléfono móvil cumple con los requisitos gubernamentales de exposición a ondas de radio. Las pautas se basan en estándares que fueron desarrollados por organizaciones científicas independientes a través de evaluaciones periódicas y exhaustivas de estudios científicos. Los estándares incluyen un margen de seguridad sustancial diseñado para garantizar la seguridad de todas las personas independientemente de su edad o salud. Tipo de dispositivo: Smooth (FCC ID: GAO-SM6222) también se ha probado con este límite de SAR. s 16 .8 8 6.26 Max La potencia de salida indicada es ERP para frecuencias inferiores a 1 GHz y EIRP para frecuencias superiores a 1 GHz. El cumplimiento de SAR para configuraciones operativas para llevar sobre el cuerpo se limita a las configuraciones específicas probadas para esta presentación. Las operaciones en el cuerpo están restringidas a clips para cinturón, fundas o accesorios similares que no tienen componentes metálicos en el ensamblaje y deben proporcionar una separación de al menos 1,0 cm entre el dispositivo y el cuerpo del usuario. Los usuarios finales deben estar informados de los requisitos operativos de uso corporal para cumplir con el cumplimiento de la exposición a RF. El SAR más alto informado para la cabeza, los accesorios para llevar en el cuerpo, el producto específico (enrutador inalámbrico) y las condiciones de uso de transmisión simultánea esde0.1 W/kg, 076 W / kg, 0.76 W/kg y0.917 W / kg respectivamente. 14. Garantía: Para obtener más información sobre la garantía de su teléfono, el servicio postventa y los centros de reparación y / o una versión completa de la Guía del usuario, visite www.smoothmobile.us -14- 2.Insira o cartão SIM e o cartão de memória 1.Conheça o seu telefone -15- Impressão digital Luz de flash Câmera traseira Aumentar / Diminuir o volume Ligar /Desligar Tela Câmera frontal potência Entrada USB Cartão de memória SIM1 Impressão digital Palestrante Microfone Palestrante SIM2 13. Informações da taxa de absorção (SAR): Este telefone celular atende aos requisitos do governo para exposição a ondas de rádio. As diretrizes baseiam-se em padrões desenvolvidos por organizações científicas independentes por meio de avaliações periódicas e completas deestudos científicos. Os padrões incluem uma margem de segurança substancial projetada para garantir a segurança de todas as pessoas, independentemente da idade ou estado de saúde. Para obter mais informações sobre a garantia do seu telefone, serviço pós-venda e centros de reparo e / ou uma versão completa do Guia do Usuário, visite www.smoothmobile.us -21- Tipo de dispositivo: Smooth 6.26 (FCC ID: GAO-SM6222)Max também foi testado em relação a estelimite de SAR. 14. Garantia: A saída de energia listada é ERP para frequências abaixo de 1 GHz e EIRP para frequências acima de 1 GHz. A conformidade com SAR para configurações de operação junto ao corpo é limitada às configurações específicas testadas para este arquivamento. As operações junto ao corpo são restritas a clipes de cinto, estojos ou acessórios semelhantes que não possuem nenhum componente metálico na montagem e devem fornecer uma separação de pelo menos 1,0 cm entre o dispositivo e o corpo do usuário. Os usuários finais devem ser informados sobre os requisitos de operação junto ao corpo para atender à conformidade de exposição à RF. O SAR mais alto relatado para condições de uso de transmissão simultânea na cabeça, acessório para uso no corpo, produto específico (roteador sem fio) e transmissão simultânea é de 0.116 W / kg 0.768 W / kg, 0.768 W / kg e 0.917 W / kg, , respectivamente. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determ…

Text truncated - open the document above for the full version.

Block Diagram

CollageInvestmentsLLC. AgentAuthorization Company:CollageInvestmentsLLC. Address:6030NW99Ave#414Doral,FL33178 ProductName:Smartphone TradeMark:SSmooth ModelNumber(s):Smooth6.26Max FCCID:GAO-SM6222 WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2022-01-10 Name:DanielEstebanGonzalez Title:Manager Company:CollageInvestmentsLLC.

Cover Letter(s)

CollageInvestmentsLLC. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2022-01-10 Subject;RequestforConfidentiality FCCID:GAO-SM6222 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsForU-NIIDevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:DanielEstebanGonzalez Title:Manager

External Photos

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of5 ExternalPhotosoftheEUT Fig.1 Fig.2 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of5 Fig.3 Fig.4 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of5 Fig.5 Fig.6 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of5 Fig.7 Fig.8 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of5 Fig.9

ID Label/Location Info

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 _____________________________________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of1 LABELANDLOCATION (Size:L5.0cmx2.0cm) LabelLocation Smartphone Model:Smooth6.26Max FCCID:GAO-SM6222

Internal Photos

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of9 InternalPhotosoftheEUT Fig.1 Fig.2 BT/WIFI/GPSANT 2G/3G/4GANT ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of9 Fig.3 Fig.4 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of9 Fig.5 Fig.6 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of9 Fig.7 Fig.8 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of9 Fig.9 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page6of9 Fig.10 Fig.11 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page7of9 Fig.12 Fig.13 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page8of9 Fig.14 Fig.15 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page9of9 Fig.16 Fig.17

RF Exposure Info

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of169 SARTESTREPORT For CollageInvestmentsLLC. Smartphone TestModel:Smooth6.26Max Preparedfor:CollageInvestmentsLLC. Address:6030NW99Ave#414Doral,FL33178 Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:(86)755-82591330 Fax:(86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:December09,2021 Numberoftestedsamples:2 SampleNo.:211207028A-1,211207028A-2 Serialnumber:Prototype DateofTest:December09,2021~December25,2021 DateofReport:December30,2021 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of169 SARTESTREPORT ReportReferenceNo.................:LCS211207028AEB DateOfIssue...............................:December30,2021 TestingLaboratoryName........:ShenzhenLCSComplianceTestingLaboratoryLtd. Address........................................:101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China TestingLocation/Procedure........:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–¡ Otherstandardtestingmethodâ–¡ Applicant’sName......................: CollageInvestmentsLLC. Address........................................: 6030NW99Ave#414Doral,FL33178 TestSpecification: Standard.......................................: IEEEStdC95.1,2019&IEEEStd1528â„¢-2013&FCCPart2.1093 TestReportFormNo...................:LCSEMC-1.0 TRFOriginator............................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF..................................:Dated2014-09 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwill notassumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterial duetoitsplacementandcontext. TestItemDescription................:Smartphone TradeMark..................................:SSmooth Model/TypeReference................:Smooth6.26Max OperationFrequency...................: GSM850/PCS1900,WCDMABandII/V; LTEBand2/4/5/7/38; WLAN2.4G,5.2G,5.8GandBluetooth5.0. Ratings.........................................: Input:5.0V950mA ForAdapterInput:110-240V~,50/60Hz,200mA ForAdapterOutput:5.0V950mA,Max4.5W DC3.8VbyRechargeableLi-ionBattery,3000mAh Result.........................................: Positive Compiledby:Supervisedby:Approvedby: PingLi/Fileadministrators JinWang/TechniqueprincipalGavinLiang/Manager ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of169 SAR--TESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS211207028AEB December30,2021 Dateofissue Type/Model.........................:Smooth6.26Max EUT.......................................:Smartphone Applicant..............................:CollageInvestmentsLLC. Address..................................:6030NW99Ave#414Doral,FL33178 Telephone..............................:/ Fax.........................................:/ Manufacturer.......................: CollageInvestmentsLLC. Address..................................:6030NW99Ave#414Doral,FL33178 Telephone..............................:/ Fax.........................................:/ Factory..................................:/ Address..................................:/ Telephone..............................:/ Fax.........................................:/ ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of169 RevisonHistory RevisionIssueDateRevisionsRevisedBy 000December30,2021InitialIssueGavinLiang ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of169 TABLEOFCONTENTS 1.TESTSTANDARDSANDTESTDESCRIPTION......................................................................................................................6 1.1.TESTSTANDARDS....................................................................................................................................................................6 1.2.TESTDESCRIPTION..................................................................................................................................................................6 1.3.GENERALREMARKS................................................................................................................................................................6 1.4.PRODUCTDESCRIPTION...........................................................................................................................................................6 1.5.STATEMENTOFCOMPLIANCE..................................................................................................................................................9 2.TESTENVIRONMENT...............................................................................................................................................................10 2.1.TESTFACILITY..................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page117of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page118of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page119of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page120of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page121of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page122of169 5.4SID1900DipoleCalibrationCertificate ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page123of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page124of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page125of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page126of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page127of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page128of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page129of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page130of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page131of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page132of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page133of169 5.5SID2450DipoleCalibrationCeriticate ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page134of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page135of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page136of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page137of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page138of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page139of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page140of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page141of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page142of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page143of169 ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page144of169 5.6SID2600DipoleCalibrationCeriticate Shenz…

Text truncated - open the document above for the full version.

Test Report

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 1 AppendixF:TestDataforE-UTRABand2 ProductName:Smartphone TestModel:Smooth6.26Max EnvironmentalConditions Temperature: 23.5  C RelativeHumidity:52.2% ATMPressure:100.0kPa TestEngineer:LingZhu Supervisedby:LIHuan ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 2 F.1ConductedAveragePowerData TestResult BandBandwidthModulationChannelRBConfigurationResult(dBm)Verdict Band21.4MHzQPSK186071RB#021.47PASS Band21.4MHzQPSK186071RB#221.46PASS Band21.4MHzQPSK186071RB#521.43PASS Band21.4MHzQPSK186073RB#021.52PASS Band21.4MHzQPSK186073RB#121.48PASS Band21.4MHzQPSK186073RB#321.51PASS Band21.4MHzQPSK186076RB#020.43PASS Band21.4MHzQPSK189001RB#021.15PASS Band21.4MHzQPSK189001RB#221.11PASS Band21.4MHzQPSK189001RB#521.18PASS Band21.4MHzQPSK189003RB#021.21PASS Band21.4MHzQPSK189003RB#121.28PASS Band21.4MHzQPSK189003RB#321.29PASS Band21.4MHzQPSK189006RB#020.29PASS Band21.4MHzQPSK191931RB#021.08PASS Band21.4MHzQPSK191931RB#221.15PASS Band21.4MHzQPSK191931RB#521.06PASS Band21.4MHzQPSK191933RB#021.18PASS Band21.4MHzQPSK191933RB#121.16PASS Band21.4MHzQPSK191933RB#321.26PASS Band21.4MHzQPSK191936RB#020.10PASS Band21.4MHz16QAM186071RB#021.44PASS Band21.4MHz16QAM186071RB#221.44PASS Band21.4MHz16QAM186071RB#521.50PASS Band21.4MHz16QAM186073RB#020.10PASS Band21.4MHz16QAM186073RB#120.28PASS Band21.4MHz16QAM186073RB#320.30PASS Band21.4MHz16QAM186076RB#019.59PASS Band21.4MHz16QAM189001RB#021.28PASS Band21.4MHz16QAM189001RB#221.30PASS Band21.4MHz16QAM189001RB#521.25PASS Band21.4MHz16QAM189003RB#020.15PASS ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 3 Band21.4MHz16QAM189003RB#120.12PASS Band21.4MHz16QAM189003RB#320.15PASS Band21.4MHz16QAM189006RB#019.47PASS Band21.4MHz16QAM191931RB#020.51PASS Band21.4MHz16QAM191931RB#220.58PASS Band21.4MHz16QAM191931RB#521.19PASS Band21.4MHz16QAM191933RB#020.23PASS Band21.4MHz16QAM191933RB#120.31PASS Band21.4MHz16QAM191933RB#320.25PASS Band21.4MHz16QAM191936RB#019.41PASS Band23MHzQPSK186151RB#021.64PASS Band23MHzQPSK186151RB#821.66PASS Band23MHzQPSK186151RB#1421.54PASS Band23MHzQPSK186158RB#020.56PASS Band23MHzQPSK186158RB#420.60PASS Band23MHzQPSK186158RB#720.60PASS Band23MHzQPSK1861515RB#020.60PASS Band23MHzQPSK189001RB#021.20PASS Band23MHzQPSK189001RB#821.28PASS Band23MHzQPSK189001RB#1421.24PASS Band23MHzQPSK189008RB#020.35PASS Band23MHzQPSK189008RB#420.46PASS Band23MHzQPSK189008RB#720.40PASS Band23MHzQPSK1890015RB#020.40PASS Band23MHzQPSK191851RB#021.30PASS Band23MHzQPSK191851RB#821.25PASS Band23MHzQPSK191851RB#1421.28PASS Band23MHzQPSK191858RB#020.34PASS Band23MHzQPSK191858RB#420.32PASS Band23MHzQPSK191858RB#720.35PASS Band23MHzQPSK1918515RB#020.30PASS Band23MHz16QAM186151RB#020.03PASS Band23MHz16QAM186151RB#819.95PASS Band23MHz16QAM186151RB#1420.34PASS Band23MHz16QAM186158RB#019.86PASS Band23MHz16QAM186158RB#419.89PASS Band23MHz16QAM186158RB#719.85PASS ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 4 Band23MHz16QAM1861515RB#019.56PASS Band23MHz16QAM189001RB#020.13PASS Band23MHz16QAM189001RB#820.18PASS Band23MHz16QAM189001RB#1420.26PASS Band23MHz16QAM189008RB#019.52PASS Band23MHz16QAM189008RB#419.53PASS Band23MHz16QAM189008RB#719.71PASS Band23MHz16QAM1890015RB#019.44PASS Band23MHz16QAM191851RB#019.63PASS Band23MHz16QAM191851RB#820.02PASS Band23MHz16QAM191851RB#1420.03PASS Band23MHz16QAM191858RB#019.55PASS Band23MHz16QAM191858RB#419.47PASS Band23MHz16QAM191858RB#719.40PASS Band23MHz16QAM1918515RB#019.32PASS Band25MHzQPSK186251RB#021.82PASS Band25MHzQPSK186251RB#1221.69PASS Band25MHzQPSK186251RB#2421.69PASS Band25MHzQPSK1862512RB#020.71PASS Band25MHzQPSK1862512RB#620.71PASS Band25MHzQPSK1862512RB#1320.64PASS Band25MHzQPSK1862525RB#020.69PASS Band25MHzQPSK189001RB#021.32PASS Band25MHzQPSK189001RB#1221.31PASS Band25MHzQPSK189001RB#2421.39PASS Band25MHzQPSK1890012RB#020.39PASS Band25MHzQPSK1890012RB#620.39PASS Band25MHzQPSK1890012RB#1320.45PASS Band25MHzQPSK1890025RB#020.46PASS Band25MHzQPSK191751RB#021.54PASS Band25MHzQPSK191751RB#1221.45PASS Band25MHzQPSK191751RB#2421.32PASS Band25MHzQPSK1917512RB#020.39PASS Band25MHzQPSK1917512RB#620.40PASS Band25MHzQPSK1917512RB#1320.34PASS Band25MHzQPSK1917525RB#020.45PASS Band25MHz16QAM186251RB#020.79PASS ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 5 Band25MHz16QAM186251RB#1220.77PASS Band25MHz16QAM186251RB#2420.71PASS Band25MHz16QAM1862512RB#019.74PASS Band25MHz16QAM1862512RB#619.73PASS Band25MHz16QAM1862512RB#1319.72PASS Band25MHz16QAM1862525RB#019.57PASS Band25MHz16QAM189001RB#019.80PASS Band25MHz16QAM189001RB#1219.88PASS Band25MHz16QAM189001RB#2419.74PASS Band25MHz16QAM1890012RB#019.49PASS Band25MHz16QAM1890012RB#619.49PASS Band25MHz16QAM1890012RB#1319.48PASS Band25MHz16QAM1890025RB#019.51PASS Band25MHz16QAM191751RB#020.48PASS Band25MHz16QAM191751RB#1220.10PASS Band25MHz16QAM191751RB#2420.10PASS Band25MHz16QAM1917512RB#019.44PASS Band25MHz16QAM1917512RB#619.46PASS Band25MHz16QAM1917512RB#1319.37PASS Band25MHz16QAM1917525RB#019.26PASS Band210MHzQPSK186501RB#021.67PASS Band210MHzQPSK186501RB#2421.66PASS Band210MHzQPSK186501RB#4921.59PASS Band210MHzQPSK1865025RB#020.71PASS Band210MHzQPSK1865025RB#1220.71PASS Band210MHzQPSK1865025RB#2520.72PASS Band210MHzQPSK1865050RB#020.71PASS Band210MHzQPSK189001RB#021.33PASS Band210MHzQPSK189001RB#2421.32PASS Band210MHzQPSK189001RB#4921.36PASS Band210MHzQPSK1890025RB#020.41PASS Band210MHzQPSK1890025RB#1220.40PASS Band210MHzQPSK1890025RB#2520.42PASS Band210MHzQPSK1890050RB#020.46PASS Band210MHzQPSK191501RB#021.58PASS Band210MHzQPSK191501RB#2421.42PASS Band210MHzQPSK191501RB#4921.35PASS ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 6 Band210MHzQPSK1915025RB#020.46PASS Band210MHzQPSK1915025RB#1220.49PASS Band210MHzQPSK1915025RB#2520.40PASS Band210MHzQPSK1915050RB#020.52PASS Band210MHz16QAM186501RB#020.61PASS Band210MHz16QAM186501RB#2420.52PASS B…

Text truncated - open the document above for the full version.

Test Report

ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 79 Band2-3MHz-16QAM-18900-1RB#0-Range1:0.009~0.15MHz Band2-3MHz-16QAM-18900-1RB#0-Range2:0.15~30MHz Band2-3MHz-16QAM-18900-1RB#0-Range3:30~1000MHz ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 80 Band2-3MHz-16QAM-18900-1RB#0-Range4:1000~10000MHz Band2-3MHz-16QAM-18900-1RB#0-Range5:10000~20000MHz Band2-3MHz-16QAM-19185-1RB#0-Range1:0.009~0.15MHz ShenzhenLCSComplianceTestingLaboratoryLtd.FCCID:GAO-SM6222ReportNo.:LCS211207028AEI 81 Band2-3MHz-16QAM-19185-1R…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Daniel Esteban Gonzalez(Manager)
[email protected]7869728404Fax: 7869728404

Technical Contact

Collage Investments LLC
[email protected]

United States

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
24272.58 GHz - 2.62 GHz88.10 mW8M99W7D2.5 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.12W/kg, 0.77W/kg, 0.77W/kg and 0.92W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Other Applications from Collage Investments LLC.

Mobile Phone - FCC ID GAO-FLIP4G - Collage Investments LLC.
GAO-FLIP4G

Mobile Phone

Nov 30, 2023

Equipment Class

DTS - Digital Transmission System
Smartphone - FCC ID GAO-VISPLU - Collage Investments LLC.
GAO-VISPLU

Smartphone

Jan 30, 2023

Equipment Class

DTS - Digital Transmission System
Smartphone - FCC ID GAO-VISION - Collage Investments LLC.
GAO-VISION

Smartphone

Jan 17, 2023

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Smart phone - FCC ID GAO-SMTH60 - Collage Investments LLC.
GAO-SMTH60

Smart phone

Oct 13, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart phone - FCC ID GAO-55MAX22 - Collage Investments LLC.
GAO-55MAX22

Smart phone

Jun 07, 2022

Equipment Class

PCE - PCS Licensed Transmitter held to ear