Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
August 7, 2020 TUV SUD America Inc. 10 Centennial Drive Peabody, MA 01960, USA Dear Sir or Madam, We, ACCO Brands USA LLC of, hereby authorize Todd Heriford of ACCO Brands, Four Corporate Drive, Lake Zurich, IL 60047, USA to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Yours sincerely, Name: Benjamin Hsu Title: Compliance Manager, ACCO Brands USA LLC
August 7, 2020 TUV SUD America Inc. 10 Centennial Drive Peabody, MA 01960, USA Dear Sir or Madam, We, ACCO Brands USA LLC of, hereby authorize Todd Heriford of ACCO Brands, Four Corporate Drive, Lake Zurich, IL 60047, USA to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Yours sincerely, Name: Benjamin Hsu Title: Compliance Manager, ACCO Brands USA LLC
2320 Presidential Drive, Suite 101, Durham, NC 27703 USA Voice: 919-381-4235 Certification Exhibit FCC ID: GV3-20SP0M1 FCC Rule Part: 47 CFR Part 2.1091 TÜV SÜD Project Number: 72159794 Manufacturer: ACCO Brands USA LLC Model: SensorPod-M RF Exposure Model: SensorPod-M FCC ID: GV3-20SP0M1 TÜV SÜD Project: 72159794 TÜV SÜD America, Inc. Page 2 General Information: Applicant: ACCO Brands USA LLC Device Category: Mobile Environment: General Population/Uncontrolled Exposure Technical Information: Antenna Type: PCB Trace Antenna Antenna Gain: 2.0 dBi Maximum Transmitter Conducted Power: -6.11 dBm, 0.245 mW Maximum System EIRP: -4.11 dBm, 0.388 mW Exposure Conditions: 20 centimeters or greater MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: S = 2 4R PG Where: S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Table 1: MPE Calculation Transmit Frequency (MHz) Radio Power (dBm) Power Density Limit (mW/Cm2) Radio Power (mW) Antenna Gain (dBi) Antenna Gain (mW eq.) Distance (cm) Power Density (mW/cm^2) 2402 -6.11 1.00 0.24 2 1.585 20 0.00008
Report: RD72159794.602 TÜV SÜD America Inc. Page 1 of 29 2320 Presidential Dr Suite 101, Durham NC 27703-8077, Ph: 919-748-4615 Certification Test Report FCC ID: GV3-20SP0M1 IC: 6128A-20SP0M1 FCC Rule Part: 15.247 ISED Canada’s Radio Standards Specification: RSS-247 TÜV SÜD Report Number: RD72159794.602 Manufacturer: ACCO Brands USA, LLC Model: SensorPod-M Test Begin Date: May 20, 2020 Test End Date: July 27, 2020 Report Issue Date: August 28, 2020 A2LA Cert. No. 2955.18 This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, ANSI, or any agency of the Federal Government. Prepared by: Chris Gormley RF Wireless Engineer TÜV SÜD America Inc. Reviewed by: Kirby Munroe Technical Manager, US Wireless TÜV SÜD America, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of TÜV SÜD America Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. Report: RD72159794.602 TÜV SÜD America Inc. Page 2 of 29 2320 Presidential Drive Suite 101 Durham NC 27703-8077 USA, PH: 919-748-4615 TABLE OF CONTENTS 1GENERAL ............................................................................................................................................ 3 1.1PURPOSE .......................................................................................................................................... 3 1.2PRODUCT DESCRIPTION ................................................................................................................... 3 1.3TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 3 2TEST FACILITIES .............................................................................................................................. 4 2.1LOCATION ....................................................................................................................................... 4 2.2LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 4 2.3RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 5 2.3.1Semi-Anechoic Chamber Test Site .......................................................................................... 5 2.4CONDUCTED EMISSIONS TEST SITE DESCRIPTION ........................................................................... 6 3APPLICABLE STANDARD REFERENCES .................................................................................... 7 4LIST OF TEST EQUIPMENT ............................................................................................................ 7 5SUPPORT EQUIPMENT .................................................................................................................... 8 6EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ........................................................... 8 7SUMMARY OF TESTS ....................................................................................................................... 9 7.1ANTENNA REQUIREMENT –FCC:15.203 ........................................................................................ 9 7.2POWER LINE CONDUCTED EMISSIONS –FCC:15.207;ISEDCANADA:RSS-GEN 8.8 .................... 9 7.2.1Measurement Procedure ......................................................................................................... 9 7.2.2Measurement Results .............................................................................................................. 9 7.36DB/99%BANDWIDTH –FCC:15.247(A)(2);ISEDCANADA:RSS-2475.2(A),RSS-GEN 6.7 ....12 7.3.1Measurement Procedure ........................................................................................................12 7.3.2Measurement Results .............................................................................................................12 7.4FUNDAMENTAL EMISSION OUTPUT POWER –FCC:15.247(B)(3);ISEDCANADA:RSS-2475.4(D) 16 7.4.1Measurement Procedure ........................................................................................................16 7.4.2Measurement Results .............................................................................................................16 7.5EMISSION LEVELS –FCC:15.247(D),15.205,15.209;ISEDCANADA RSS-2475.5,RSS-GEN 8.9/8.10 ......................................................................................................................................................18 7.5.1Emissions into Non-restricted Frequency Bands ...................................................................18 7.5.1.1Measurement Procedure ................................................................................................................... 18 7.5.1.2Measurement Results ....................................................................................................................... 18 7.5.2Emissions into Restricted Frequency Bands ..........................................................................21 7.5.2.1Measurement Procedure ................................................................................................................... 21 7.5.2.2Duty Cycle Correction ..................................................................................................................... 21 7.5.2.3Measurement Results ....................................................................................................................... 21 7.5.2.4Sample Calculation: ......................................................................................................................... 26 7.6POWER SPECTRAL DENSITY –FCC:15.247(E);ISEDCANADA:RSS-2475.2(B) ..........................27 7.6.1Measurement Procedure ........................................................................................................27 7.6.2Measurement Results ..…
Text truncated - open the document above for the full version.
2320 Presidential Drive, Suite 101, Durham, NC 27703 USA Voice: 919-381-4235 Page 1 Certification Exhibit FCC ID: GV3-20SP0M1 IC: 6128A-20SP0M1 FCC Rule Part: 15.247 ISED Canada’s Radio Standards Specification: RSS-247 TÜV SÜD Project Number: 72159794 Manufacturer: ACCO Brands USA, LLC Model: SensorPod-M Test Setup Photos Model(s): SensorPod-M FCC ID: GV3-20SP0M1 IC: 6128A-20SP0M1 Project: 72159794 TÜV SÜD America Inc. Page 2 Figure 1: Radiated Emissions – Front – Below 1GHz Figure 2: Radiated Emissions – Back – Below 1GHz Model(s): SensorPod-M FCC ID: GV3-20SP0M1 IC: 6128A-20SP0M1 Project: 72159794 TÜV SÜD America Inc. Page 3 Figure 3: Radiated Emissions – Front – Above 1GHz Figure 4: Radiated Emissions – Back – Above 1GHz Model(s): SensorPod-M FCC ID: GV3-20SP0M1 IC: 6128A-20SP0M1 Project: 72159794 TÜV SÜD America Inc. Page 4 Figure 5: RF Conducted Measurements Figure 6: Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 245.00 µW |
KB270 EQ Rechargeable Keyboard
Equipment Class
DTS - Digital Transmission SystemKensington Vertical Wireless Mouse
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
MY430 Rechargeable Mouse
Equipment Class
DTS - Digital Transmission System
Wireless Presenter with Red Laser-Nano Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Pro Fit Ergo Wireless Keyboard
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter