Presenter Expert ™ Red Laser Presenter with Cursor Control INSTRUCTION GUIDE HASZNÁLATI ÚTMUTATÓ GUIDE D’INSTRUCTIONS PŘÍRUČKA S POKYNY BEDIENUNGSANLEITUNG INSTRUKCJA OBSŁUGI HANDLEIDING РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ ISTRUZIONI MANUAL DE INSTRUÇÕES MANUAL DE INSTRUCCIONES Register Now! Enregistrer maintenant ! Jetzt registrieren! Nu registreren Registrar ahora Registra adesso Regisztràljon most! Zaregistrujte se nyní! Zarejestruj się! Зарегистрироваться! Registe-se agora! register.kensington.com INSTRUCTION GUIDE 901-2672- 00 KL Technical Support / Assistance technique / Technischer Support / Technische ondersteuning / Supporto tecnico / Asistencia técnica / Műszaki támogatás / Technická podpora / Pomoc techniczna / Техническая поддержка / Assistência técnica Australia1300 881 931Nederland010 713 1882 België / Belgique02 401 2395New Zealand0800 539 26273 Brasil14 3235-4003Norway80017520 Canada1 800 268 3447Österreich0800 677 873 Denmark80 250966Polska22 570 18 00 Deutschland0692 222 3654Portugal800855802 España911 146 735Russia007 495 933 5163 Finland0800 9 15697Schweiz / Suisse044 580 6667 France01 7671 0404Sweden08 5033 6577 Hungary06 20 9430 612United Kingdom0203 364 5390 Ireland01 431 1395United States1 800 535 4242 Italia02 3604 7030International Toll+31 53 484 9135 México55 15 00 57 00 Kensington Computer Products Group A Division of ACCO Brands 333 Twin Dolphin Drive, Sixth floor Redwood Shores, CA 94065 ACCO MEXICANA, S.A. DE C.V. Avenida Circuito de la Industria Norte # 6 Parque Industrial Lerma, Lerma, 52000 Estado de Mexico MEXICO Designed in California, U.S.A. by Kensington Made in China ACCO Brands Europe Oxford House Oxford Road Aylesbury Bucks, HP21 8SZ United Kingdom Acco Brands Chile S.A., Avda. San Josemaría Escrivá de Balaguer Nº5773 Vitacura, C.P. 7640870 Santiago Chile ACCO Brands Canada 5 Precidio Court Brampton Ontario, L6S 6B7 Canada Tilibra Produtos de Papelaria Ltda. Rua Aimorés, 6-9 Bauru, CEP 17013-900 São Paulo Brasil www.kensington.com Patents Pending ACCO Australia Level 2, 8 Lord St Botany NSW 2019 Australia N1368 23 Getting Started / Démarrage / Erste Schritte / Aan de slag / Introduzione / Introducción / Első lépések / Začínáme / Przygotowanie do pracy / Приступая к работе / Introdução 150' (50m) max. 150’ (50m) max. Maximal 50 m (150 Fuß) Max. 50 meter (150 voet) 50 m max 150’ (50m) máx. 150’ (50m) max. Max. 150’ (50m). 150’ (50m) maks. 150’ (50 м) макс. 150’ (50m) máx. 1 2 3 On/Off switch / Interrupteur Marche/Arrêt / Ein-/Ausschalter / Aan-uit-schakelaar / Interruttore On/Off / Interruptor de encendido/apagado / BE/KI kapcsoló / Vypínač / Włączanie/wyłączanie / Выключатель питания / Interruptor On/Off (Ligado/Desligado) Mode switch / Bouton du mode / Moduswechsel / Modusschakelaar / Interruttore di modalità / Conmutador de modo / Üzemmódkapcsoló / Přepnutí režimu / Przełącznik trybu / Переключатель режимов / Interruptor de modo 45 LED Indicator / Voyant lumineux / LED-Anzeige / LED-indicatielampje / Indicatore LED / Indicador luminoso / LED jelző / Kontrolka LED / Dioda / Светодиодный индикатор / Indicador de LED Presentation Mode / Mode présentation / Präsentationsmodus / Presentatiemodus / Modalità di presentazione / Modo de presentación / Bemutató mód / Režim Prezentace / Tryb prezentacji / Режим презентации / Modo Apresentação Joystick, cursor control. Press for left mouse button / Joystick de navigation. Cliquez sur le bouton gauche de la souris / Joystick, Cursorsteuerung. Drücken = Klick mit linker Maustaste / Joystick, cursorbesturing. Indrukken voor linkermuisknop / Controllo del cursore con il joystick Corrisponde al pulsante sinistro del mouse / Joystick, control de cursor. Pulsar para botón izquierdo del ratón / Joystick, kurzorvezérlés. A bal egérgombot nyomja meg / Pákový ovladač, ovladač kurzoru. Stiskněte levé tlačítko myši / Joystick, sterowanie kursorem. Wciśnięcie spełnia rolę lewego przycisku myszy / Джойстик, управление курсором. Функция левой кнопки мыши / Joystick, controlo do cursor. Prima para activar o botão esquerdo do rato Laser pointer / Pointeur laser / Laserpointer / Laseraanwijzer / Puntatore laser / Puntero láser / Lézeres mutató / Laserový ukazatel / Wskaźnik laserowy / Лазерная указка / Apontador laser Next / Suivant / Weiter / Volgende / Avanti / Siguiente / Tovább / Další / Dalej / Далее / Seguinte Black screen / Écran vide / Schwarzer Bildschirm / Zwart scherm / Schermo nero / Pantalla negra / Fekete képernyő / Černá obrazovka / Wygaszony ekran / Черный экран / Ecrã a preto Previous / Précédent / Zurück / Vorige / Precedente / Anterior / Előző / Předchozí / Wstecz / Назад / Anterior Power On / Marche / Einschalten / Inschakelen / Acceso / Alimentación encendida / Bekapcsolva / Zapnutí / Włączone zasilanie / Питание вкл / Alimentação ligada Red on (3 secs) / Rouge allumé (3 secs) / Rot an (3 Sek.) / Rood AAN (3 sec.) / Rosso acceso (3 sec.) / Rojo encendido (3 segundos) / Piros be (3 mp) / svítí červeně (3 sek.) / Świeci się na czerwono (3 s) / Горит красный (3 сек.) / Vermelho aceso (3 seg.) Laser On / Laser allumé / Laser an / Laser aan / Laser acceso / Láser encendido / Lézer bekapcsolva / Zapnutí laseru / Włączony laser / Лазер вкл / Laser ligado Red on / Rouge allumé / Rot an / Rood AAN / Rosso acceso / Rojo encendido / Piros be / svítí červeně / Świeci się na czerwono / Горит красный / Vermelho aceso Low Battery / Voyant de batterie faible / Akku fast leer / Batterij bijna leeg / Batteria scarica / Nivel de batería bajo / Akkumulátor kimerülőben / Slabá baterie / Niski stan baterii / Низкий уровень заряда батареи / Bateria Fraca Red Blinking / Voyant rouge clignotant / Rote LED blinkt / Rood knipperend / Rosso lampeggiante / Rojo parpadeando / Villogó piros lámpa / Bliká červená / Miga na czerwono / Красный мигает / Vermelho a piscar 67 English CAUTION! IMPORTANT SAFETY INSTRUCTIONS The Presenter Expert™ Red Laser Presenter includes a built-in laser pointer. Therefore, as with any laser pointer, it is important to…
Text truncated - open the document above for the full version.
ACCO Brands, Inc. DATE: 2012-09-17 To whom it may concern: We the undersigned, hereby authorize EMCCert DR. RAŠEK GmbH and Neutron Engineering Inc.to ac t on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by EMCCert DR. RAŠEK GmbH on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from (ACCO Brands, Inc.). Sincerely, (Name and Title) Maggie Zhang , QA Compliance Engineer
ACCO Brands, Inc. To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for confidentiality FCC ID: GV3M01174-T Dear FCC TCB: 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Schematic Block diagram Operational description Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials: Internal Photos Planned Release Date STC: 180 days from date of grant Justification: This document contains detailed system and equipment description is considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor unfair advantage in the market. Sincerely, Maggie Zhang Sep 17, 2012
Neutron Engineering Inc. Project No.: 1209C013 Page 2 of 7
Label location
Neutron Engineering Inc. Project No.: 1209C013 Page 3 of 7 Neutron Engineering Inc. Project No.: 1209C013 Page 4 of 7 Neutron Engineering Inc. Project No.: 1209C013 Page 5 of 7 Neutron Engineering Inc. Project No.: 1209C013 Page 6 of 7 Neutron Engineering Inc. Project No.: 1209C013 Page 7 of 7
Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 1 of 65 FCC/IC Radio Test Report FCC ID: GV3M01174-T IC: 6128A-M01174T This report concerns (check one): Original Grant Class II Change Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Sep. 01, 2012 Date of Test: Sep. 01, 2012 ~ Sep. 08, 2012 Testing Engineer : (David Mao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Issued Date : Sep. 10, 2012 Project No. : 1209C013 Equipment : 2.4G Wireless Red Laser Presenter Model Name : M01174-T Applicant for FCC : ACCO Brands, Inc Address for FCC : 333 Twin Dolphin Drive, Sixth Floor, Redwood Shores, CA 94065, USA Applicant for IC : ACCO Canada Inc. Address for IC : 5 Precidio Court Brampton Ontario L6S 6B7 Canada Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 2 of 65 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 3 of 65 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 MEASUREMENT INSTRUMENTS LIST 17 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 22 4.2.7 TEST RESULTS (BELOW 30MHz) 23 4.2.8 TEST RESULTS (BETWEEN 30 – 1000 MHz) 24 4.2.9 TEST RESULTS (ABOVE 1000 MHz) 36 5 . BANDWIDTH TEST 54 5.1 MEASUREMENT INSTRUMENTS LIST 54 5.2 TEST PROCEDURE 54 5.3 DEVIATION FROM STANDARD 54 5.4 TEST SETUP 54 5.5 EUT OPERATION CONDITIONS 54 5.6 TEST RESULTS 55 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 57 6.1 APPLIED PROCEDURES / LIMIT 57 Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 4 of 65 Table of Contents Page 6.1.1 MEASUREMENT INSTRUMENTS LIST 57 6.1.2 TEST PROCEDURE 57 6.1.3 DEVIATION FROM STANDARD 57 6.1.4 TEST SETUP 57 6.1.5 EUT OPERATION CONDITIONS 57 6.1.6 TEST RESULTS 58 7 . EUT TEST PHOTO 63 Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 5 of 65 1. CERTIFICATION Equipment : 2.4G Wireless Red Laser Presenter Brand Name : Kensington Model Name : M01174-T Applicant for FCC : ACCO Brands, Inc Applicant for IC : ACCO Canada Inc. Factory : Sysgration(Shenzhen) Ltd. Address : Egongling Village, Pinghu Town, Longgang Dist, Shenzhen City, China Date of Test : Sep. 01, 2012 ~ Sep. 08, 2012 Test Sample : Engineering Sample Standards : FCC Part15, Subpart C(15.249)/ ANSI C63.4 : 2009; Canada RSS-210:2010 ; Canada RSS-Gen:2010 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1209C013) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 6 of 65 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Canada RSS-Gen:2010 StandardSection FCC RSS-210/ RSS-Gen Test Item Judgment Remark 15.207 RSS-Gen 7.2.2 Conducted Emission - N/A 15.209 RSS-210 2.7 Radiated Emission PASS 15.249 RSS-210 A2.9(a) Radiated Spurious Emission PASS NOTE: (1)”N/A” denotes test is not applicable in this test report. Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 7 of 65 2.1 TEST FACILITY The test facilities used to collect the test data in this report is DG-C01/DG-CB03 at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792 Neutron's test firm number for FCC 319330 Neutron's test firm number for IC 4428B-1 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 63 of 65 7. EUT TEST PHOTO Radiated Measurement Photos 9K-30MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 64 of 65 Radiated Measurement Photos 30M~1000MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1209C013 Page 65 of 65 Radiated Measurement Photos Above 1000MHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.47 GHz | - |
KB270 EQ Rechargeable Keyboard
Equipment Class
DTS - Digital Transmission SystemKensington Vertical Wireless Mouse
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
MY430 Rechargeable Mouse
Equipment Class
DTS - Digital Transmission System
Wireless Presenter with Red Laser-Nano Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Pro Fit Ergo Wireless Keyboard
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter