Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EVAL-HCRWATCH4Z One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A. • Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com ADI Confidential Vital Signs Monitoring (VSM) Watch PLEASE SEE THE LAST PAGE FOR AN IMPORTANT WARNING AND LEGAL TERMS AND CONDITIONS. Rev. Sp0 | Page 1 of 20 FEATURES Vital signs monitoring platform Wearable battery powered platform Real-time live data view Data storage to flash memory for offline analyses Easy configuration DEVICES HOSTED IN THE VSM WATCH nRF52840 ADP5360 ADXL362 ADPD4100 AD8233 5940 AD7156 EVALUATION KIT CONTENTS The VSM Watch A Charging Cradle A USB Type A to micro-USB cable Firmware Debug Board SOFTWARE NEEDED VSM WaveTool GENERAL DESCRIPTION The vital sign monitoring (VSM) watch, EVAL-HCRWATCH4Z, is a modular development, demonstration, and data collection platform for high performance vital signs monitoring applications based on Analog Devices, Inc., analog front ends and sensors. It is a wearable, battery-powered device which enables the continuous monitoring and on-demand spot check measurement of photoplethysmography (PPG), electrodermal activity (EDA, bioimpedance-based), skin temperature, electrocardiography (ECG, biopotential based), and motion/activity (based on a 3-axis accelerometer). It allows for synchronized, multiparameter data storage on internal memory for later data retrieval and offline analysis and/or live monitoring on a PC (Windows® OS) or Android or iOS-based device. PREPARING THE VSM WATCH Before using the VSM watch, proper preparations must be made. Ensure the battery of the watch is charged and the WaveTool program for PC is successfully installed. See the Powering Up the System for the First Time sections for installation instructions. The watch firmware must be upgraded using the VSM WaveTool. CONDITIONS REGARDING THE USE OF THIS PRODUCT IN HEALTHCARE APPLICATIONS This device design is being provided as-is without any express or implied representations or warranties of any kind and the use of this device shall impose no legal obligation on Analog Devices, Inc., and its subsidiaries, employees, directors, officers, servants, and agents. In addition, it is understood and agreed to that the device is not authorized for use in safety critical healthcare applications (such as life support) in which malfunction or failure of a product can be expected to result in personal injury or death. This device must not be used for diagnostic purposes. It must not be used with a defibrillator or other equipment that produces high voltages in excess of the supply rails on the evaluation board. This device is provided for evaluation and development purposes only. It is not intended for use as, or as part of, an end product. Any use of the device in such applications is at your own risk and you shall fully indemnify Analog Devices, its subsidiaries, employees, directors, officers, servants and agents for all liability and expenses arising from such unauthorized usage. You are solely responsible for compliance with all legal and regulatory requirements connected to such use. ADI Confidential Rev. Sp0 | Page 2 of 20 TABLE OF CONTENTS Features ......................................................................................................... 1 Devices Hosted in the VSM Watch .................................................... 1 Evaluation Kit Contents ......................................................................... 1 Software Needed ....................................................................................... 1 General Description ................................................................................. 1 Preparing the VSM Watch ..................................................................... 1 Conditions Regarding the Use of This Product in Healthcare Applications ................................................................................................ 1 Revision History ........................................................................................ 2 Evaluation Platform Overview ........................................................... 3 Evaluation Platform ................................................................................. 7 Overview .................................................................................................. 7 Powering Up the System for the First Time ............................. 7 Water Resistance .................................................................................. 7 Bluetooth USB PC Dongle (nRF52840) ...................................... 7 Buttons...................................................................................................... 8 Display Indicators ................................................................................ 9 Software Tools .................................................................................... 10 Vital Signs Monitored .......................................................................... 11 Photoplethysmography (PPG)—ADPD4100 ........................ 11 Motion and Activity - ADXL362 .................................................. 11 Electrocardiography - AD8233................................................... 11 Bio-Impedance – AD5940 ............................................................. 11 Skin and Ambient Temperature ................................................. 12 Use Cases ................................................................................................... 13 Embedded Algorithms for Evaluation ......................................... 16 Pedometer ............................................................................................ 16 Automatic Gain Control ................................................................. 16 Battery Life and Memory Footprint .............................................. 17 Battery Life .......................................................................................... 1…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZEM2012013318CR FCC ID: HRF-VSMW4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
First step:Switch to about page. How to access to FCC ID and warning words Second step:Enter ABOUT page How to access to FCC ID and warning words Third step:Switch to FCC ID page, and enter warning words page. How to access to FCC ID and warning words
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 Internal Photos for SZEM2012013318CR FCC ID: HRF-VSMW4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331803 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM2012013318CR Applicant: Analog Devices Incorporated Address of Applicant: One Technology Way PO Box 9106, Norwood, Massachusetts, 02062-9106, United States Manufacturer: Analog Devices Incorporated Address of Manufacturer: One Technology Way Wilmington, MA 01887 (United States) Factory: SHENZHEN FENDA TECHNOLOGY CO., LTD. Address of Factory: FENDA HI-TECH PARK, ZHOUSHI ROAD SHIYAN, BAOAN, SHENZHEN Equipment Under Test (EUT): EUT Name: Vital Signs Monitoring Watch Model No.: EVAL-HCRWATCH4Z Trade mark: Analog Devices FCC ID: HRF-VSMW4 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2020-12-23 Date of Test: 2021-02-10 to 2021-02-10 Date of Issue: 2021-02-18 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331803 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2021-02-18 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331803 Page: 3 of 6 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 4 4.2 TEST LOCATION ................................................................................................................................ 5 4.3 TEST FACILITY .................................................................................................................................. 5 4.4 DEVIATION FROM STANDARDS ............................................................................................................ 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 5 5 SAR EVALUATION ................................................................................................................................. 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ........................................................................................ 6 5.1.1 Standard Requirement ................................................................................................................ 6 5.1.2 Limits .......................................................................................................................................... 6 5.1.3 EUT RF Exposure ....................................................................................................................... 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331803 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: DC 5V from charging base input AC 120V/60Hz Lithium Ion Battery: 3.8V 200mAh rechargeable battery which charged by charging base Cable(s): USB cable: 26cm unshielded Bluetooth Version: V5.0 LE Data Rate: Only support 1Mb/s Operation Frequency: 2402MHz to 2480MHz Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PIFA Antenna Antenna Gain: -5.09dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331803 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331803 Page: 6 of 6 5 SAR Evaluation 5.1 RF Exposure Compliance Re…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331802 Page: 1 of 51 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2012013318CR Applicant: Analog Devices Incorporated Address of Applicant: One Technology Way PO Box 9106, Norwood, Massachusetts, 02062-9106, United States Manufacturer: Analog Devices Incorporated Address of Manufacturer: One Technology Way Wilmington, MA 01887 (United States) Factory: SHENZHEN FENDA TECHNOLOGY CO., LTD. Address of Factory: FENDA HI-TECH PARK, ZHOUSHI ROAD SHIYAN, BAOAN, SHENZHEN Equipment Under Test (EUT): EUT Name: Vital Signs Monitoring Watch Model No.: EVAL-HCRWATCH4Z Trade Mark: Analog Devices FCC ID: HRF-VSMW4 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-12-23 Date of Test: 2021-02-10 to 2021-02-10 Date of Issue: 2021-02-18 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331802 Page: 2 of 51 Revision Record Version Chapter Date Modifier Remark 01 2021-02-18 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331802 Page: 3 of 51 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201331802 Page: 4 of 51 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED PEAK OUTPUT POWER ................................................................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Mode Description ............................................................................................................12 7.1.3 Test Setup Diagram ................................................................................................................13 7.1.4 Measurement Procedure and Data .........................................................................................13 7.2 MINIMUM 6DB BANDWIDTH .............................................................................................................14 7.2.1 E.U.T. Operation .....................................................................................................................14 7.2.2 Test Mode Description ..................................................................................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 2 Setup Photos for SZEM2012013318CR FCC ID: HRF-VSMW4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 2 1 Photographs Radiated Emissions which fall in the restricted bands Radiated Spurious Emissions
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.60 mW |
JBP - Part 15 Class B Computing Device Peripheral
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral