FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Senstar Corporation/
  3. I5T-BR100

I5T-BR100Senstar BR100

Senstar Corporation
Senstar BR100 - FCC ID I5T-BR100 - Senstar Corporation
Click to zoom

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Feb 15, 2021
Application Purpose
Original Equipment
Date of Application
Feb 15, 2021
Equipment Note
Senstar BR100
Frequency Range
24102.50000000 - 24147.50000000
Company
Senstar Corporation
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Product Guide UltraW ave BR100 ™ Microwave Detection Sensor E5DA0102-001, Rev A July 23, 2020 BR100 Produc t Guide Senstar Corporation Website: www.senstar.com Email address: [email protected] E5DA0102-001, Rev A July 23, 2020 Sens tar and the Senstar logo a re registere d trademarks, and BR100 and S ilver Network are trademarks of Senstar Corporation. P roduct names and C ompany names included i n this document are u sed o nly for identifica tion p urposes and are the property o f, and m ay be t rademarks of, their r espective owners. Copyright © 2019, Senstar C orporation. All rights reserved. The information provided in t his guide has been prepared by Senstar Corporation to the b est of i ts ability. Senstar Corporation is not res ponsib le for any damage or accidents that may occur due to e rrors or omissions in this guide. Senstar Corporation is not liable for a ny damages, or incidental conseque n ces, arising f rom the u se of, or the inability to use, the software a nd e quipment described in this guide. Senstar C orporation i s n ot responsible for any d amage or accidents that may o ccur due to information a bout items o f equipment o r components manufactu red by other companies. F eature s a nd specifications are subject to change without notice . Any changes o r modifications to the software or equipment that are not expressly approved by S enstar Corporation void the manufacturer’s w arranty, and could void the user’s authority to operate the equipment. The figures included i n t his document are for illustration purpos e s only, a nd ma y differ from the actual equipment. Senstar Corporation’s Quality Management System is ISO 9001:2015 registered. Compliance: C anada: I ndustry Canada Identification Number: transmitter 1454B-BR100 Europe: This device complies with ETSI standard EN 300 440 for European operation The use of shielded cables is required for compliance. S ervice statement - We ensure t hat our products are correctly applied to achieve the maximum benefits for the end-user. We work hand-in-hand with our customers and remain accessible through all stages of a project - from concept to deployment to long-term support. We provide design as sistance, site surveys, installation support, comprehensive documentation, training, post-installation annual calibration and maintenance visits, electronics and software extended warranty, rapid factory repair service and on-call/ eme rgency service. Contact Senstar Corpora tion to inquire about how a package can be customized for your unique applications. This device complies with Industry Canada l icense-exempt RSS standard(s). Operation is subject to t he following two conditions: ( 1) This device may not cause harmful interference, and (2) this d evice must accept any i nterference received, including interference that may cause u ndesired operation.A ny C hanges or modificat ions notexpr essly a pproced by the party responsible for compliance could void t he user's authority t o operate the equipment. Ce dispositif est conforme aux normes CNR d’Industrie Canada applicables aux appareils radio exempts de licence. Son f onctionnement est su jet aux d eux conditions suivantes : 1 ) le dispositif ne doit pas produire d e brouillage prĂ©judiciable; et 2) il d oit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indĂ©sirable. Tout changement ou modification non expressĂ©ment approuvĂ© par la partie responsable de la conformitĂ© peut annuler le droit de l'utilisateur Ă  utiliser l'Ă©quipement. USA : FCC Identification Number: I5T-BR100 FCC Certification - This device complies with part 15 of the F CC Rules. Operation is subject to the following two conditions: (1) This de vice may not cause harmful interference, and (2) this devic e m ust accept any interference received, i ncluding i nterference that may cause u ndesired operation. Any Changes or modifications notexpressly approced by the party responsible for compliance could void the user's authority to operate the equipment. This equipment h as been tested and fou nd to comply with the lim its for a Class B digital device, pursuant to Part 15 of the FCC R ules. These limits are designed t o provide reasonable protection against harmful inter ference i n a residential installation. This equipment generates, uses a nd can radiat e r adio frequency energy and, i f not installed and u sed i n accorda nce with the i nstructions, may cause harmful interference to radi o communications. Ho wever, there is no guarantee that int erfere nce will not o cc ur in a particular installation. If this equipment does cause harmful interference to radi o or television reception, which can be d etermined by turning the equipmen t off and on, the u ser is encouraged to try to correct the i nterference by one or more of the f ollowing measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -C onnect the eq uipment int o an outlet on a circuit different from t hat to which the receiver is connect ed. -C onsult the dealer or an experienced radio/TV t echnician for help. This equipment complies with ISEDC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This equipment should be installed and operated with minimum distance 20cm between the radiator &you body. Cet Ă©quipement est conforme aux limites d'exposition aux rayonnements ISEDC dĂ©finies pour un environnement non contr?lĂ©. Cet Ă©metteur ne doit pas ĂŞtre colocalisĂ© ou fonctionner en conjonction avec une autre antenne ou un autre Ă©metteur.Cet Ă©quipement doit ĂŞtre installĂ© et exploitĂ© Ă  une distance minimale de 20cm entre le radiateur et le corps. BR100 Product GuidePage 3 Table of contents 1 System planning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 Site design - - - - - - - - - - - -…

Text truncated - open the document above for the full version.

Cover Letter(s)

Senstar Corporation Address: 119 John Cavanaugh Drive, Carp, Ontario, Canada Tel.: 613-839-5572 Fax: 613-839-5830 E-mail: [email protected] FCC Confidential Authorization Date: 2021-02-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: I5T-BR100 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Senstar Corporation hereby requests long-term confidential treatment of information accompanying this application as outlined below: ď‚· Block Diagram ď‚· Schematics ď‚· Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Name:Bill Hodgins Title: VP Engineering

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

MANUFACTURED IN CANADA FCC ID: I5T-BR100HVIN:A This device complies with part 15 of the FCC rules.Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) this device must accept any interference received,including interference that may cause undesired operation. SERIAL NUMBER: TX CARP, ONTARIOCANADA, K0A 1L0119 JOHN CAVANAUGH DR. TM E5EM0101-001 IC: 1454B-BR100 BR100 Transmitter 12 - 48V 1.2 W label location

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Ant Ant

Test Report

RSS-GEN, ISSUE 5 MARCH 2019 AMENDMENT 1 RSS-210, ISSUE 10, DECEMBER 2019 FCC PART 15.245 TEST REPORT For Senstar Corporation 119 John Cavanaugh Drive, Carp, Ontario, Canada FCC ID: I5T-BR100 IC: 1454B-BR100 Report Type: Original Report Product Type: Senstar BR100 Re port Number: RTZ201009001-00A Re port Date: 2021-01-15 Reviewed By: Ivan Cao Assistant Manager Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RTZ201009001-00A Page 2 of 35 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 DECLARATIONS ............................................................................................................................................................ 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT CABLE LIST AND DETAILS ............................................................................................................................ 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 7 RSS-102 § 2.5.2 - EXEMPTION LIMITS FOR ROUTINE EVALUATION – RF EXPOSURE EVALUATION ......................................................................................................................................................................................... 8 APPLICABLE STANDARD .............................................................................................................................................. 8 FCC§15.203, RSS-GEN CLAUSE 6.8 - ANTENNA REQUIREMENT.................................................................... 9 APPLICABLE STANDARD .............................................................................................................................................. 9 ANTENNA CONNECTOR CONSTRUCTION ...................................................................................................................... 9 FCC §15.207 (A), RSS-GEN CLAUSE 8.8– AC LINE CONDUCTED EMISSIONS ........................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 EUT SETUP ................................................................................................................................................................ 10 EMI TEST RECEIVER SETUP ....................................................................................................................................... 10 TEST PROCEDURE ...................................................................................................................................................... 11 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 11 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 11 TEST DATA ................................................................................................................................................................ 12 FCC§15.205, §15.209&§15.245, RSS-210 ANNEX F.1, RSS-GEN CLAUSE 8.10- RADIATED EMISSIONS .. 14 APPLICABLE STANDARD ............................................................................................................................................ 14 EUT SETUP ................................................................................................................................................................ 17 TEST EQUIPMENT SETUP ............................................................................................................................................ 19 TEST PROCEDURE ...................................................................................................................................................... 19 CORREC…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View

Contact Information

Applicant

Bill Hodgins(VP Engineering)
[email protected]613 839-5572Fax: 613 839-5830

Test Firm

Bay Area Compliance Laboratories Corp.(Dongguan)David Zhang
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115.24524.10 GHz - 24.15 GHz-
Confidentiality
Long Term

Other Applications from Senstar Corporation

ultraWave bistatic receiver - FCC ID I5T-E4EM0201 - Senstar Corporation
I5T-E4EM0201

ultraWave bistatic receiver

Apr 05, 2011

Equipment Class

FDS - Part 15 Field Disturbance Sensor
ultraWave bistatic transmitter - FCC ID I5T-E4EM0101 - Senstar Corporation
I5T-E4EM0101

ultraWave bistatic transmitter

Apr 04, 2011

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Perimeter Protection System - FCC ID I5T-A4EM0101 - Senstar Corporation
I5T-A4EM0101

Perimeter Protection System

Mar 18, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
FDS - Part 15 Field Disturbance Sensor - FCC ID I5T-MW001 - Senstar Corporation
I5T-MW001

FDS - Part 15 Field Disturbance Sensor

Nov 08, 1998

Equipment Class

FDS - Part 15 Field Disturbance Sensor
I5T-BCIDS001

Perimeter Protection System

Sep 29, 1996

Equipment Class

FDS - Part 15 Field Disturbance Sensor