FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Motorola Mobility LLC/
  3. IHDT56AR5

IHDT56AR5Mobile Cellular Phone

Motorola Mobility LLC

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 17, 2024
Application Purpose
Original Equipment
Date of Application
Apr 01, 2024
Equipment Note
Mobile Cellular Phone
Frequency Range
2402.00000000 - 2480.00000000
Company
Motorola Mobility LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: March 8, 2024 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Certifications concerning “covered” equipment pursuant to Part 2.911(d)(5)(i) and (ii) FCC ID: IHDT56AR4 FCC ID: IHDT56AR5 To Whom It May Concern, As required by section 2.911(d)(5)(i) of Commission’s rules (47 CFR), Motorola Mobility LLC certifies that, as of the date of the filing of the application, the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. As required by section 2.911(d)(5)(ii) of Commission’s rules (47 CFR), Motorola Mobility LLC certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Attestation Statements

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: March 8, 2024 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Certification Designing a U.S. Agent for Service of Process Concerning “Covered” Equipment Pursuant to Section 1.50002 FCC ID: IHDT56AR4 FCC ID: IHDT56AR5 To Whom It May Concern, As required by section 2.911(d)(7) of Commission’s rules (47 CFR), Motorola Mobility LLC acknowledge, consents and certifies that, as of the date of the filing of the application until this certification is revoked in writing by the applicant: • The applicant designates itself as the U.S. agent to accept service of process. • The physical U.S. address and email of the applicant as designated agent are as follows: Attention: Jeff Narducci Company: Motorola Mobility LLC Address: 222 W. Merchandize Mart Plaza, Chicago Il US FRN: 0004321311 Email: Jeff Narducci <[email protected]> • Applicant will remain as the designated agent for service for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. • The agent accepts the designation by Motorola Mobility LLC as the U.S. agent to accept service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. Sincerely, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Cover Letter(s)

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: March 8, 2024 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Request for Confidentiality FCC ID: IHDT56AR4 FCC ID: IHDT56AR5 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting confidentiality for exhibits filed with the commission supporting the application of equipment authorization for those items referenced above. Motorola Mobility respectfully requests the Commission to withhold indefinitely from public disclosure the following attachments under Long-Term Confidentiality. ⚫ Schematic Diagrams ⚫ Block Diagrams ⚫ Part List ⚫ Operational Description ⚫ Tune-up Procedure The above listed documents contain detailed system and equipment descriptions that are proprietary and confidential information under Motorola trade secret protection. Public disclosure of above documents would be harmful to our company and would provide competitors an unfair advantage. This information is not made publicly available even after commercial release of the device. In additional to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We request the commission to grant short-term confidentiality request on the following attachments for 180 days after the grant as outlined in Public Notice DA 04-1705. ⚫ External Photos ⚫ Internal Photos ⚫ Test Setup Photos ⚫ User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and that information will be available for public review once the grant of equipment authorization is issued. Sincerely, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Cover Letter(s)

Motorola Mobility LLC 222 W. Merchandize Mart Plaza, Chicago Il US www.motorola.com Date: March 8, 2024 To whom it may concern, Please be notified that I, Jeff Narducci, have designated Jones Tsai of Sporton International Inc. and Dai Lihua of Motorola Mobility LLC as the persons being responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out in their professional capacity by Jones Tsai of Sporton International Inc. and Dai Lihua of Motorola Mobility LLC in connection with all processes required for FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. We further certify that neither the applicant nor any party to this application, as defined in 47 CFR Ch. 1.2002 (b), is subject to a denial to Federal benefits, that include FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1998, 21 U.S.C. 862. This authorization is limited to the following product, and shall remain in place until completion of the certification, or until revoked, whichever is earlier: FCC ID: IHDT56AR4 FCC ID: IHDT56AR5 If you have any acknowledgement and response, please send it to Sporton International Inc. directly. Should you have any questions or comments regarding this matter, please don’t hesitate to contact me. Sincerely yours, Jeff Narducci Director, Global Regulatory Compliance [email protected]

Cover Letter(s)

Declaration Model Information: Manufacturer’s Name: Motorola Mobility LLC Manufacturer’s Business Address: 222 W, Merchandise Mart Plaza, Chicago IL 60654 USA Model Name: XT2429-2 HW version: DVT2 SW version: U2UU34.8 Description: We Motorola Mobility LLC declare H Software change history are list below Software Change Note SW 1:U2UU34.11 SW 2:U2UU34.16 SW 3:U2UU34.8 The difference between SW1 , SW2 ,SW3 is just for different SW version that not affect the RF test This declaration is issued to: Sporton International Inc. Certified By Title _________ Advisory Engineer,GT Cert Tel Email +86-18150396535 [email protected] Date 2024.3.21 Signature

ID Label/Location Info

FCC E-Label Information A. Images of the e-label screen are provided below: B. Access to the required information on the e-label Users are able to access the information in no more than three steps in a device’s menu. The actual steps are: Settings > then type Regulatory No any special accessories, access codes, or SIM card are required to go through the above steps. C. Devices have physical labels at point of marketing/sale visible to the purchaser (or in the alternative, on the packaging), and at time of importation? At the time of importation, marketing, and sale, the device will have the required physical label on the packaging, which will include the device’s FCC ID. D. Electronic labeling information is programmed into the device by the manufacturer at the time of manufacture. Yes. E. Electronic labeling information not modifiable by any third party. The e-label of the device is programmed by the grantee and secured in such a manner that it cannot be modified by third parties. F. All the applicable regulatory information required on the packaging or user instructions is provided according to the rules. Applicable regulatory information not found in the e-label is contained in the user manual.

RF Exposure Info

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/1/30 System Check_Head_750MHz DUT: D750V3 - SN:1087 Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium: HSL_750 Medium parameters used: f = 750 MHz; σ = 0.889 S/m; ε = 42.269; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.33, 6.33, 6.33); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.566 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 25.65 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.716 W/kg SAR(1 g) = 0.425 W/kg; SAR(10 g) = 0.278 W/kg Maximum value of SAR (measured) = 0.571 W/kg 0 dB = 0.571 W/kg = -2.43 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/1 System Check_Head_835MHz DUT: D835V2 - SN:4d091 Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 835 MHz; σ = 0.912 S/m; ε = 41.936; ρ = 1000 r 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.633 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.87 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.738 W/kg SAR(1 g) = 0.489 W/kg; SAR(10 g) = 0.332 W/kg Maximum value of SAR (measured) = 0.594 W/kg 0 dB = 0.594 W/kg = -2.26 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/3 System Check_Head_1900MHz DUT: D1900V2 - SN:5d118 Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: HSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.406 S/m; ε = 40.2; ρ = 1000 r 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.6 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(5.14, 5.14, 5.14); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 2.46 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 33.79 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 3.38 W/kg SAR(1 g) = 1.89 W/kg; SAR(10 g) = 0.985 W/kg Maximum value of SAR (measured) = 2.32 W/kg 0 dB = 2.32 W/kg = 3.65 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/5 System Check_Head_2600MHz DUT: D2600V2 - SN:1070 Communication System: UID 0, CW (0); Frequency: 2600 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2600 MHz; σ = 2.031 S/m; ε = 40.358; ρ = 1000 r 3 kg/m Ambient Temperature:23.4 °C; Liquid Temperature:22.8 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(4.69, 4.69, 4.69); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (71x71x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 4.66 W/kg Pin=50mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 50.25 V/m; Power Drift = 0.1 dB Peak SAR (extrapolated) = 5.95 W/kg SAR(1 g) = 2.71 W/kg; SAR(10 g) = 1.17 W/kg Maximum value of SAR (measured) = 4.75 W/kg 0 dB = 4.75 W/kg = 6.77 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/7 System Check_Head_3500MHz DUT: D3500V2 - SN:1076 Communication System: UID 0, CW (0); Frequency: 3500 MHz;Duty Cycle: 1:1 Medium: HSL_3500 Medium parameters used: f = 3500 MHz; σ = 2.81 S/m; ε r = 38.712; ρ = 1000 3 kg/m Ambient Temperature:23.3 °C; Liquid Temperature:22.6 °C DASY5 Configuration: - Probe: EX3DV4 - SN7764; ConvF(7.11, 7.11, 7.11); Calibrated: 2023/10/5 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=50mW/Area Scan (91x91x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 6.25 W/kg Pin=50mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm Reference Value = 49.33 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 8.24 W/kg SAR(1 g) = 3.15 W/kg; SAR(10 g) = 1.2 W/kg Maximum value of SAR (measured) = 6.11 W/kg 0 dB = 6.11 W/kg = 7.86 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/8 System Check_Head_3700MHz DUT: D3700V2 - SN:1008 Communication System: UID 0, CW (0); Frequency: 3700 MHz;Duty Cycle: 1:1 Medium: HSL_3700 Medium parameters used: f = 3700 MHz; σ = 2.988 S/m; ε = 38.36; ρ = 1000 r 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.6 °C DASY5 Configuration: - Probe: EX3DV4 - SN7764…

Text truncated - open the document above for the full version.

RF Exposure Info

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/1/30 01_LTE Band 71_20M_QPSK_1RB_0Offset_Right Tilted_0mm_Ch133322 Communication System: UID 0, LTE-FDD (0); Frequency: 683 MHz;Duty Cycle: 1:1 Medium: HSL_750 Medium parameters used: f = 683 MHz; σ = 0.861 S/m; ε = 42.776; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.33, 6.33, 6.33); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.588 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 16.30 V/m; Power Drift = 0.12 dB Peak SAR (extrapolated) = 1.92 W/kg SAR(1 g) = 0.633 W/kg; SAR(10 g) = 0.260 W/kg Maximum value of SAR (measured) = 0.810 W/kg 0 dB = 0.810 W/kg = -0.92 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/1/30 02_FR1 n71_30M_QPSK_1RB_1Offset_Right Tilted_0mm_Ch136100 Communication System: UID 0, 5G NR (0); Frequency: 680.5 MHz;Duty Cycle: 1:1 Medium: HSL_750 Medium parameters used: f = 680.5 MHz; σ = 0.861 S/m; ε = 42.776; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.33, 6.33, 6.33); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.440 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 14.37 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.70 W/kg SAR(1 g) = 0.499 W/kg; SAR(10 g) = 0.203 W/kg Maximum value of SAR (measured) = 0.785 W/kg 0 dB = 0.785 W/kg = -1.05 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/1 03_GSM850_GPRS (2 Tx slots)_Left Cheek_0mm_Ch189 Communication System: UID 0, GSM850 (0); Frequency: 836.4 MHz;Duty Cycle: 1:4.15 Medium: HSL_835 Medium parameters used: f = 836.4 MHz; σ = 0.904 S/m; ε = 42.013; ρ = 1000 r 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.290 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.31 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.323 W/kg SAR(1 g) = 0.256 W/kg; SAR(10 g) = 0.197 W/kg Maximum value of SAR (measured) = 0.278 W/kg 0 dB = 0.278 W/kg = -5.56 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/1 04_WCDMA V_RMC 12.2Kbps_Left Cheek_0mm_Ch4182 Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 836.4 MHz; σ = 0.913 S/m; ε r = 41.933; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: -Probe: ES3DV3 -SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 -Sensor-Surface: 3mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.187 W/kg Zoom Scan (6x7x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.225 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 0.381 W/kg SAR(1 g) = 0.181 W/kg; SAR(10 g) = 0.109 W/kg Maximum value of SAR (measured) = 0.196 W/kg 0 dB = 0.196 W/kg = -7.08 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/1 05_LTE Band 26_15M_QPSK_1RB_0Offset_Right Cheek_0mm_Ch26865 Communication System: UID 0, LTE-FDD (0); Frequency: 831.5 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 831.5 MHz; σ = 0.902 S/m; ε = 42.056; ρ = 1000 r 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.881 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 16.38 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 1.72 W/kg SAR(1 g) = 0.650 W/kg; SAR(10 g) = 0.360 W/kg Maximum value of SAR (measured) = 0.929 W/kg 0 dB = 0.929 W/kg = -0.32 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/1 06_FR1 n5_25M_QPSK_1RB_1Offset_Right Cheek_0mm_Ch167300 Communication System: UID 0, 5G NR (0); Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 836.5 MHz; σ = 0.913 S/m; ε r = 41.933; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: -Probe: ES3DV3 -SN3293;…

Text truncated - open the document above for the full version.

RF Exposure Info

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/12 26_LTE Band 26_15M_QPSK_1RB_0Offset_Back_5mm_Ch26865 Communication System: UID 0, LTE-FDD (0); Frequency: 831.5 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 831.5 MHz; σ = 0.934 S/m; ε r = 42.534; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: -Probe: ES3DV3 -SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 -Sensor-Surface: 3mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.20 W/kg Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 12.89 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 2.03 W/kg SAR(1 g) = 0.922 W/kg; SAR(10 g) = 0.478 W/kg Maximum value of SAR (measured) = 1.23 W/kg 0 dB = 1.23 W/kg = 0.90 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/12 27_FR1 n5_25M_QPSK_1RB_1Offset_Back_5mm_Ch167300 Communication System: UID 0, 5G NR (0); Frequency: 836.5 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 836.5 MHz; σ = 0.936 S/m; ε = 42.516; ρ = 1000 r 3 kg/m Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.722 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.58 V/m; Power Drift = -0.16 dB Peak SAR (extrapolated) = 1.12 W/kg SAR(1 g) = 0.647 W/kg; SAR(10 g) = 0.345 W/kg Maximum value of SAR (measured) = 0.672 W/kg 0 dB = 0.672 W/kg = -1.73 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/12 28_FR1 n26_20M_QPSK_1RB_1Offset_Back_5mm_Ch166300 Communication System: UID 0, 5G NR (0); Frequency: 831.5 MHz;Duty Cycle: 1:1 Medium: HSL_835 Medium parameters used: f = 831.5 MHz; σ = 0.934 S/m; ε r = 42.534; ρ = 1000 kg/m 3 Ambient Temperature:23.1 °C; Liquid Temperature:22.7 °C DASY5 Configuration: -Probe: ES3DV3 -SN3293; ConvF(6.27, 6.27, 6.27); Calibrated: 2023/11/30 -Sensor-Surface: 3mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.716 W/kg Zoom Scan (7x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.888 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 1.47 W/kg SAR(1 g) = 0.637 W/kg; SAR(10 g) = 0.329 W/kg Maximum value of SAR (measured) = 0.861 W/kg 0 dB = 0.861 W/kg = -0.65 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/14 29_GSM1900_GPRS (2 Tx slots)_Back_5mm_Ch512 Communication System: UID 0, PCS (0); Frequency: 1850.2 MHz;Duty Cycle: 1:4.15 Medium: HSL_1900 Medium parameters used: f = 1850.2 MHz; σ = 1.4 S/m; ε = 38.8; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(5.14, 5.14, 5.14); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.32 W/kg Zoom Scan (7x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.578 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 1.75 W/kg SAR(1 g) = 0.959 W/kg; SAR(10 g) = 0.529 W/kg Maximum value of SAR (measured) = 1.15 W/kg 0 dB = 1.15 W/kg = 0.61 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/14 30_WCDMA II_RMC 12.2Kbps_Bottom Side_5mm_Ch9262 Communication System: UID 0, WCDMA (0); Frequency: 1852.4 MHz;Duty Cycle: 1:1 Medium: HSL_1900 Medium parameters used: f = 1852.4 MHz; σ = 1.401 S/m; ε r = 38.793; ρ = 1000 kg/m 3 Ambient Temperature:23.2 °C; Liquid Temperature:22.5 °C DASY5 Configuration: -Probe: ES3DV3 -SN3293; ConvF(5.14, 5.14, 5.14); Calibrated: 2023/11/30 -Sensor-Surface: 3mm (Mechanical Surface Detection) -Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 -Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 -Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (41x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.34 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 27.39 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 1.93 W/kg SAR(1 g) = 1.02 W/kg; SAR(10 g) = 0.546 W/kg Maximum value of SAR (measured) = 1.28 W/kg 0 dB = 1.28 W/kg = 1.07 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/14 31_LTE Band 2_20M_QPSK_1RB_0Offset_Bottom Side_5mm_Ch18900 Communication System: UID 0, LTE-FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1 Medium: HSL_1900 Medium parameters used: f = 1880 MHz; σ = 1.415 S/m; ε = 38.749; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.5 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(5.14, 5.14, 5.14); Calibrated: 2023/11/…

Text truncated - open the document above for the full version.

RF Exposure Info

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/16 52_LTE Band 7_20M_QPSK_1RB_0Offset_Back_5mm_Ch21350 Communication System: UID 0, LTE-FDD (0); Frequency: 2560 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2560 MHz; σ = 1.989 S/m; ε = 40.214; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(4.69, 4.69, 4.69); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (91x161x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.38 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.116 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 2.53 W/kg SAR(1 g) = 1.08 W/kg; SAR(10 g) = 0.475 W/kg Maximum value of SAR (measured) = 1.43 W/kg Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.116 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 2.26 W/kg SAR(1 g) = 0.964 W/kg; SAR(10 g) = 0.423 W/kg Maximum value of SAR (measured) = 1.32 W/kg 0 dB = 1.32 W/kg = 1.21 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/16 53_LTE Band 41_20M_QPSK_1RB_0Offset_Back_5mm_Ch41490 Communication System: UID 0, LTE-TDD (0); Frequency: 2680 MHz;Duty Cycle: 1:1.59 Medium: HSL_2600 Medium parameters used: f = 2680 MHz; σ = 2.104 S/m; ε = 40.063; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(4.69, 4.69, 4.69); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (91x171x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.30 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.273 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 2.51 W/kg SAR(1 g) = 1.06 W/kg; SAR(10 g) = 0.419 W/kg Maximum value of SAR (measured) = 1.38 W/kg Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.273 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 2.26 W/kg SAR(1 g) = 0.848 W/kg; SAR(10 g) = 0.361 W/kg Maximum value of SAR (measured) = 1.17 W/kg 0 dB = 1.17 W/kg = 0.68 dBW/kg Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab Date: 2024/2/16 54_FR1 n7_40M_QPSK_1RB_1Offset_Back_5mm_Ch507000 Communication System: UID 0, 5G NR (0); Frequency: 2535 MHz;Duty Cycle: 1:1 Medium: HSL_2600 Medium parameters used: f = 2535 MHz; σ = 1.953 S/m; ε = 40.351; ρ = 1000 r 3 kg/m Ambient Temperature:23.2 °C; Liquid Temperature:22.7 °C DASY5 Configuration: - Probe: ES3DV3 - SN3293; ConvF(4.69, 4.69, 4.69); Calibrated: 2023/11/30 - Sensor-Surface: 3mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1650; Calibrated: 2023/9/13 - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: TP-1842 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (91x171x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 1.04 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.376 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 1.90 W/kg SAR(1 g) = 0.9…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jeff Narducci(Director Product Compliance)
[email protected]847-687-6928Fax: 847-687-6928

Test Firm

Sporton International Inc. (Kunshan)Jim Tsai
[email protected]+86 0512 57900158

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz20.60 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. SAR compliance for body- worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 5.0 mm, as described in this filing. End-users must be informed of the body- worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router) and simultaneous transmission exposure conditions are 0.26 W/kg, 0.17 W/kg, 0.25 W/kg and 1.56 W/kg, respectively.

Other Applications from Motorola Mobility LLC

IHDT56AX5

Mobile Cellular Phone

Aug 28, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IHDT56AW9

Smart Watch

May 12, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IHDT56AW5

Mobile Cellular Phone

Apr 08, 2026

Equipment Class

DTS - Digital Transmission System
IHDT56AW6

Smart Watch

Mar 18, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IHDT56AX4

Mobile Cellular Phone

Mar 17, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear