Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model: MRQTR PMN: MagicMount Charge Pro HD FCC ID: IKQMRQTR FCC Statement: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment For CLASS B digital devices or peripherals, also add the following from the FCC 15.105 standard to the instructions. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: âReorient or relocate the receiving antenna. âIncrease the separation between the equipment and receiver. âConnect the equipment into an outlet on a circuit different from that to which the receiver is connected. âConsult the dealer or an experienced radio/TV technician for help. Shielded cables must be used with this unit to ensure compliance with the Class B FCC limits. FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipmen t should be installed and operated with a minimum distance of 20 cm between the radiator and your body. HVIN: MRQTR Model: MRQTR IC: 6955A-MRQTR Le prĂ©sent appareil est conforme aux CNR dâIndustrie Canada applicables aux appareils radio exempts de licence. Lâexploitation est autorisĂ©e aux deux conditions suivantes :(1) lâappareil ne doit pas produire de brouillage, et (2) lâutilisateur de lâappareil doit accepter tout brouillage radioĂ©lectrique subi, mĂȘme si le brouillage est susceptible dâen compromettre le fonctionnement. Any Changes or modifications not expressly approved by the party responsible for compliance could void the userâs authority to operate the equipment. IC Caution: RSS-Gen Issue 5 "&" RSS-Gen numĂ©ro 5 - English: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadaâs licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF exposure statement: The equipment complies with IC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 10cm between the radiator and your body. - French: Cet appareil contient des Ă©metteurs / rĂ©cepteurs exemptĂ©s de licence conformes aux RSS (RSS) d'Innovation, Sciences et DĂ©veloppement Ă©conomique Canada. Le fonctionnement est soumis aux deux conditions suivantes: (1) Cet appareil ne doit pas causer d'interfĂ©rences. (2) Cet appareil doit accepter toutes les interfĂ©rences, y compris celles susceptibles de provoquer un fonctionnement indĂ©sirable de l'appareil. Tout changement ou modification non expressĂ©ment approuvĂ© par la partie responsable de la conformitĂ© pourrait annuler l'autoritĂ© de l'utilisateur Ă utiliser l'Ă©quipement. DĂ©claration d'exposition RF: L'Ă©quipement est conforme Ă la limite d'exposition aux radiations de la IC Ă©tablie pour un environnement non contrĂŽlĂ©. Cet Ă©quipement doit ĂȘtre installĂ© et utilisĂ© avec une distance minimale de 10 cm entre le radiateur et votre corps. Input: 5Vâ3A, 9Vâ3A, 12Vâ3A Output: 25W
Rev 1/26/2023 Scosche Industries Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Mar. 02, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: IKQMRQTR [Scosche Industries Inc] certifies that the equipment for which authorization is sought is not âcoveredâ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Scosche Industries Inc] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Mark Larson Rev 1/26/2023 Scosche Industries Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Mar. 02, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: IKQMRQTR [Scosche Industries Inc] certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing âcoveredâ equipment. Sincerely, (Applicant signature) (Applicant printed name) Mark Larson
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Scosche Industries Inc Address: 1550 Pacific Ave, Oxnard, California 93033, United States FRN: 0027464049 Contact Name: Mark Larson Telephone No: 805-486-4450 E-mail: [email protected] This letter is to confirm that the US Agent for Service of Process accepts responsibility to act as a local representative on behalf of Scosche Industries Inc The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Applicant: Company Name: Scosche Industries Inc Product Description: magicMOUNT RUGGED FRN: 0027464049 Grantee Code: IKQ FCC ID: IKQMRQTR Contact Name: Mark Larson Address: 1550 Pacific Ave, Oxnard, California 93033, United States Telephone No: 805-486-4450 E-mail: [email protected] The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. This Agreement is valid until (Permanently valid). Date: 2026/3/02 Applicantâs Name: Scosche Industries Inc US Agent for Service of Processâs Name: Scosche Industries Inc Title: SR Product Manager Title: SR Product Manager Signature Signature
Scosche Industries Inc Family models declaration letter Mar. 02, 2026 We Scosche Industries Inc Of 1550 Pacific Ave, Oxnard, California 93033, United States Declare under our sole responsibility that the product FCC ID: IKQMRQTR Product: magicMOUNT RUGGED Model Number: MRQTR, MRQTR-20, MRQTR-25 All the models are the same circuit and module, except the differences in the diameter of the connecting ball at the bottom, accessories and model No.. Mark Larson/ SR Product Manager E-mail : [email protected] Phone : 805-486-4450 Fax : 805-486-9996 Address : 1550 Pacific Ave, Oxnard, California 93033, United States
Scosche Industries Inc Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 8, 2026 Subject; Request for Confidentiality FCC ID: IKQMRQTR To Whom It May Concern, Pursuant to the provisions of the Commissionâs rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Mark Larson Title: SR Product Manager
Effective Date: April 2, 2020 QSF 7.6.4-8 â Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Scosche Industries Inc Date: Mar. 02, 2026 Product Model Number: MRQTR, MRQTR-20, MRQTR-25 FCC ID: IKQMRQTR To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: ï· Testing ï· Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Title: SR Product Manager Email: [email protected] Telephone: 805-486-4450 On behalf of: Scosche Industries Inc
Ext Photos Model: MRQTR Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8
23 2318.718.7 5.5 5.5 0.77 0.77 Unit: mm
Int Photos Model: MRQTR Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 ANT
- Page 1 of 12 - Report No.: HB20260202005E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com RF EXPOSURE Test Report Product: magicMOUNT RUGGED Trade Mark: SCOSCHE Model Number: MRQTR FCC ID: IKQMRQTR Prepared for Scosche Industries Inc 1550 Pacific Ave, Oxnard, California 93033, United States Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 12 - Report No.: HB20260202005E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 6 2 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 2.1 TEST LABORATORY ..................................................................................................................................................... 7 2.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 2.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 7 2.4 TEST SOFTWARE ........................................................................................................................................................ 7 3 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 4 RF EXPOSURE..................................................................................................................................................... 9 4.1 MAXIMUM PERMISSIBLE EXPOSURE .............................................................................................................................. 9 4.1.1. Limit ............................................................................................................................................................ 9 4.1.2. Test Procedures ........................................................................................................................................... 9 4.1.3. Test Setup .................................................................................................................................................... 9 4.1.4. Test Result ................................................................................................................................................... 9 5 PHOTOGRAPHS OF THE TEST SETUP ..................................................................................................................12 - Page 3 of 12 - Report No.: HB20260202005E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com TEST RESULT CERTIFICATION Applicantâs Name ................. : Scosche Industries Inc Address ................................. : 1550 Pacific Ave, Oxnard, California 93033, United States Manufacturer's Name .......... : Scosche Industries Inc Address ................................. : 1550 Pacific Ave, Oxnard, California 93033, United States Product description Product name ........................ : magicMOUNT RUGGED Model Number ....................... : MRQTR Standards ............................. : FCC CFR 47 PART 1 , 1.1310 Test procedure ....................... : KDB 680106 D01 Wireless Power Transfer v04 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report. Date of Test ........................................... : Date (s) of performance of tests ............. : Feb. 02, 2026~Mar. 02, 2026 Test Result .............................................. : Pass Testing Engineer : ( Z o e Su) Technical Manager : ( G a r y Lu) Authorized Signatory : (L e o S u) - Page 4 of 12 - Report No.: HB20260202005E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Revision History Revised No. Date of Issue Description 01 Mar. 02, 2026 Original - Page 5 of 12 - Report No.: HB20260202005E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, GâŠ
Text truncated - open the document above for the full version.
- Page 1 of 30 - Report No.: HB20260202005E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Test Report Product: magicMOUNT RUGGED Trade Mark: SCOSCHE Model Number: MRQTR FCC ID: IKQMRQTR Prepared for Scosche Industries Inc 1550 Pacific Ave, Oxnard, California 93033, United States Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 30 - Report No.: HB20260202005E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ..................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 6 1.4 POWER SETTING CONFIGURATION PARAMETERS ............................................................................................................... 6 1.5 ANCILLARY EQUIPMENT .............................................................................................................................................. 6 2 SUMMARY OF TEST RESULT ............................................................................................................................... 7 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 8 3.1 TEST LABORATORY ..................................................................................................................................................... 8 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 8 3.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 8 3.4 TEST SOFTWARE ........................................................................................................................................................ 8 4 LIST OF TEST EQUIPMENT .................................................................................................................................10 5 TEST ITEM AND RESULTS ...................................................................................................................................12 5.1 ANTENNA REQUIREMENT .......................................................................................................................................... 12 5.2 CONDUCTED EMISSION ............................................................................................................................................. 13 5.3 RADIATED EMISSION ................................................................................................................................................ 15 5.4 OCCUPIED BANDWIDTH ............................................................................................................................................ 20 6 PHOTOGRAPHS OF THE TEST SETUP ..................................................................................................................22 7 PHOTOGRAPHS OF THE EUT..............................................................................................................................23 - Page 3 of 30 - Report No.: HB20260202005E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com TEST RESULT CERTIFICATION Applicantâs Name ................. : Scosche Industries Inc Address ................................. : 1550 Pacific Ave, Oxnard, California 93033, United States Manufacturer's Name .......... : Scosche Industries Inc Address ................................. : 1550 Pacific Ave, Oxnard, California 93033, United States Product description Product name ........................ : magicMOUNT RUGGED Model Number ....................... : MRQTR Standards ............................. : FCC Part 15C Test procedure ....................... : IEEE/ANSI C63.10-2020 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report. Date of Test ........................................... : Date (s) of performance of tests ............. : Feb. 02, 2026~Mar. 02, 2026 Test Result .............................................. : Pass Testing Engineer : ( Z o e Su) Technical Manager : ( G a r y Lu) Authorized Signatory : (L e o S u) - Page 4 of 30 - Report No.: HB20260202005E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.comâŠ
Text truncated - open the document above for the full version.
Fuda Semiconductor (Hefei) Co., Ltd. No. 5, 4th Building, Zhong'an Chuanggu Science and Technology Park, West Wangjiang Road, Hefei Science and Technology Park, Anhui Province www.nuvoltatech.com NuVolta Technologies Confidential 1 Specification for Approval Supplier Approve Customer Approve EE Confirm by PE Confirm by QE Confirm by Approval by Fuda Semiconductor (Hefei) Co., Ltd. J-FDIMPP 2023/6/1 A.0 CustomerïŒ Customer Part No.ïŒ SupplierïŒ Spec descriptionïŒ Supplier Part No.ïŒ DateïŒ VersionïŒ DrawïŒ www.nuvoltatech.com NuVolta Technologies Confidential 2 Version Change History Revision Before change After change Date Approval by A.0ââ Initial Release 2023/6/1 www.nuvoltatech.com NuVolta Technologies Confidential 3 1.Manufacturer information Items Manufacturer name Approval The first resource The second resource 2.Dimension specification Unit: mm A B C D E F G 20.5±0.5 39±1 19.5±0.3 42.5±0.5 8±1 4±1.5 2.05±0.1 Fuda Semiconductor (Hefei) Co., Ltd. Luo jie www.nuvoltatech.com NuVolta Technologies Confidential 4 NoteïŒ âŒNo high-temperature adhesive tape is applied at the coil leads. âŒWhen the coil is in contact with the magnetic shield, it must not protrude beyond the edge of the magnetic shield. 3.Schematic diagram 4.Electronic character TEMPERATURE:25±10°C, RELATIVE HUMIDITY :65±20% TIEM SPECIFICATION TEST FREQUENCY TEST EQUIPMENTS IND 8.4UH±10% 100 KHZ/1.0V LCRMETRTH2830N DCR 50mΩ Max \ PH2511S Q 100±10% 100 KHZ/1.0V LCRMETRTH2830N 5.Coil specification Turns Wire Dia. Wdg. Type Spred/Close Wdg.Directio n Intersect Yes/Not Coil Positive/ Anti Paste 11T S 0.08*80P ïŒSilk-Covered WireïŒ ïŒCloseïŒ (Anticlockwise) ïŒYesïŒ (Anti/-Paste) www.nuvoltatech.com NuVolta Technologies Confidential 5 6.Bill of materials number Material name Description Material Code 1 wire rod 0.08 * 80P Hot air twisted wire 2 Hard magnetic sheet G42.5*19.5*2.0H 3 Adhesive JS-E103 (Thickened) White Adhesive 4 5 6 7 JX-2U-F-0025
Photographs of the Test Setup Model: MRQTR Radiated Emission Below 30MHz Radiated Emission Above 30MHz MPE
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.111 MHz - 0.148 MHz | - |
| 2 | 15C | 0.36 MHz - 0.36 MHz | - |

FoundIT Locator Tag
Equipment Class
DTS - Digital Transmission System
FoundIT Passport
Equipment Class
DTS - Digital Transmission System
FoundIT Wallet+
Equipment Class
DTS - Digital Transmission System
BT FM Car Charger
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
magicMOUNT RUGGED
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz