FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Garmin International Inc/
  3. IPH-04741

IPH-04741Digital device and low power data transceiver

Garmin International Inc

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jun 24, 2024
Application Purpose
Original Equipment
Date of Application
Jun 24, 2024
Equipment Note
Digital device and low power data transceiver
Frequency Range
13.56000000 - 13.56000000
Company
Garmin International Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: March 19, 2024 SUBJECT: FCC Application for FCC ID: IPH-047 41 To Whom It May Concern: Garmin International, Inc. will continue to apply processes and procedures to ensure compliance with 47 CFR 2 requirements regarding products produced under Supplier’s Declaration of Conformity procedure for class B co mputer peripheral portion as applicable to this composite filing. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: March 27, 2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: IPH-04741 FRN: 0005088588 Garmin International, Inc., (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Ben Karsak

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: March 27, 2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: IPH-04741 Garmin International, Inc., Garmin certifies that, as of the date of t he filing of the application, Garmin International, Inc.. is our designated U.S. agent for service of process for the above referenced FCC ID. Garmin International, Inc., accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or t he conclusion of any Commission-related proceeding involving the equipment. Garmin International, Inc. accepts, as of the date of t he filing of the application, the obligation of the designated U.S. agent for service of process for t he above referenced FCC ID. Designated U.S. Agent Information: FRN: 0005088588 Name: Garmin International, Inc. Address: 1200 East 151 st Street, Olathe, Kansas, 66062 Contact Person: Ben Karsak Tel.: 913-397-1946 Email: [email protected] Sincerely, Garmin International, Inc. Ben Karsak

Attestation Statements

Rev 1/ 26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: March 27, 2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: IPH-04741 FRN: 0005088588 Garmin International, Inc., (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Ben Karsak

Cover Letter(s)

REQUEST FOR CONFIDENTIALITY D ate: 18 March 2024 Applicant: Garmin Interna�onal Subject: Confiden�ality Request for FCC ID: IPH-04741 IC: 1792A-04741 P ursuant to FCC 47 CFR 0.457(d) and 0.459, and IC RSP-100 Sec�on 12.4, we request that a part of the FCC and ISED applica�on be held confiden�al. Type Of Confiden�ality Requested Exhibit ☐Short Term☒Permanent☐Not Provided Block Diagrams ☐Short Term☒Permanent☐Not Provided Schema�cs ☐Short Term☒Permanent☐Not Provided Opera�onal Descrip�on/ Theory of Opera�on ☐Short Term☐Permanent☒Not Provided Parts List & Placement/BOM ☐Short Term☐Permanent☒Not Provided Tune-Up Procedure ☒Short Term☐Permanent☐Not Provided Test Setup Photos ☒Short Term☐Permanent☐Not Provided User’s Manual(s) ☒Short Term☐Permanent☐Not Provided External Photos ☒Short Term☐Permanent☐Not Provided Internal Photos Garmin Interna�onal has spent a substan�al effort in developing this product and it is one of the first of its kind in the industry . Having the subject informa�on easily available to "compe��on" would negate the advantage we have achieved by developing this product. Not protec�ng the details of the design will result in financial hardship. Permanent Confiden�ality: Garmin requests the e xhibits listed above as permanently confiden�al be permanently withheld from public review due to m aterials that contain tr ade s ecrets a nd proprietary informa�on not customarily released to the public. Short-Term Confiden�ality (if a pplicable): The applicant requests the exhibits selected above as short term confiden�al be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authoriza�on and prior to marke�ng. This is to avoid premature release of sensi�ve informa�on prior to marke�ng or release of the product to the public. Sincerely, David Utt Staff Complianc e Engineer Garmin International Phone: +1 913-440-3199 | www.garmin.com 1200 E. 151st St. | Olathe, Kansas 66062

Cover Letter(s)

December 12, 2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Innovation, Science and Economic Development Canada Certification and Engineering Bureau 3701 Carling Avenue PO Box 11490, Station H Ottawa, Ontario, Canada K2H 8S2 To Whom It May Concern: Pursuant to 47 CFR 2.911, Garmin International, Inc. (Garmin) has authorized the following Garmin International Associates to act on Garmin's behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) and Innovation, Science and Economic Development Canada (ISED) for equipment authorization or certification. Mr. Chris Strauss, Compliance Engineering Team Lead Mr. William Pertner, Compliance Engineering Team Lead Mr. Jay Everett, Compliance Engineering Team Lead Mr. Richard Kockelkoren, Compliance Engineer Mr. Mike Moranha, Compliance Engineer Ms. Poojita Bhattu, Compliance Engineer Mr. Jeffrey Hailey, Compliance Engineer Mr. Dan Irish, Compliance Engineer Mr. Kiran Kumar, Compliance Engineer Mr. Tim Olson, Compliance Engineer Mr. Carlos Ortega, Compliance Engineer Mr. David Utt, Staff Compliance Engineer Mr. Jonathan Shafer, Design Certification Engineer Ms. Sara Jones, Design Certification Engineer Mr. Jacky Yeung, Compliance Engineer As such, the Garmin Associates listed above are authorized to: 1) sign Form 731, 2) sign letters of application, 3) request confidentiality, and 4) exchange data and information with the FCC, IC and/or authorized TCBs on behalf of Garmin. In addition, these individuals shall be considered "authorized individuals" to act on Garmin's behalf where an "authorized individual's" attestation is necessary or preferred. This authorization remains in effect until notified to the contrary by Garmin. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.

ID Label/Location Info

E- Label Description The following specific instructions are provided in the user’s manual that is provided with the device. There are no special codes, accessories, or permissions beyond the normal security protection to unlock the screen. The following specific instructions are provided in the owner’s manual that is provided at www.garmin.com/manuals: The instructions presented here explicitly match the steps in the manual for accessing the regulatory information. This language is clear to the end user on how to access the regulatory information. The E-Label will be easily accessible by the user and cannot be modifiable by the user. The following information will appear on the display in a manner that is clearly legible without the aid of magnification. The regulatory information and dedicated exclusive application or script is secured and implemented in a factory-set-unalterable format. The regulatory information will be capable of being retrieved and displayed locally, and under the control of the end user in possession of the product. The method is secure, such that the application or script ensures that the regulatory information will be displayed correctly. The following information will be shown on the outside of the package: FCC ID: IPH-04741 IC: 1792A-04741 M/N: A04741 This device complies with part 15 of th e FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: IPH-04741 IC: 1792A-04741 M/N: A04741

RF Exposure Info

45461908 R2.0 Test Report Issue Date: 18 March 2024 ©2022 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 52 of 54 APPENDIX D – PROBE CALIBRATION 45461908 R2.0 Test Report Issue Date: 18 March 2024 ©2022 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 53 of 54 APPENDIX E – DIPOLE CALIBRATION NCL CALIBRATION LABORATORIES Calibration File No: DC-1904 Project Number: 5921 Client.: Celltech Address: 21 – 364 Lougheed Road, Kelowna, BC V1X 7R8, Canada C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized procedures and using transfer standards traceable to NRC/NIST. Validation Dipole (Head) Manufacturer: SPEAG Part number: D2450V2 Frequency: 2450 MHz Serial No: 825 Calibrated: 27/04/2021 Released on: 05/05/2021 This Calibration Certificate is incomplete unless accompanied by the Calibration Results Summary NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 2 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Conditions Dipole SN 825 was a re-calibration. Ambient Temperature of the Laboratory: 21 C +/- 0.5C Temperature of the Tissue: 21 C +/- 0.5C Primary Measurement Standards Instrument Serial Number Cal due date Signal Generator HP 83640B 3844A00689 Sept. 17, 2022 Network Analyzer Keysight E5063A MY54502902 Mar. 9, 2023 Spectrum Analyzer Keysight N9030B MY57140772 Apr. 20, 2023 Attestation The below named signatories have conducted the calibration and review of the data which is presented in this calibration report. NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 3 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Calibration Results Summary The following results relate the Calibrated Dipole and should be used as a quick reference for the user. Tissue Validation Tissue Frequency Dielectric constant,  r Conductivity,  [S/m] Head 2450 MHz 40.73 1.86 Electrical Specification Tissue Frequency Return LossImpedanceSWR: Head 2450 MHz -19.83 dB 43.26  1.23U System Validation Results Tissue Frequency 1-Gram SAR 10-Gram SAR Uncertainty Head 2450 MHz 52.719 W/kg 24.015 W/kg 19.8% Head NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 4 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Introduction This Calibration Report has been produced in line with the SSI Dipole Calibration Procedure SSI-TP-018-ALSAS. The results contained within this report are for Validation Dipole SN 825. The calibration routine consisted of a three-step process. Step 1 was a mechanical verification of the dipole to ensure that it meets the mechanical specifications. Step 2 was an Electrical Calibration for the Validation Dipole, where the SWR, Impedance, and the Return loss were assessed. Step 3 involved a System Validation using the ALSAS-10U, along with APREL E-020 30 MHz to 6 GHz E-Field Probe Serial Number 225. References o IEEE Standard 1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques o EN 62209-1:2016 Human Exposure to RF Fields from hand-held and body-mounted wireless communication devices - Human models. instrumentation, and procedures - Part 1: Procedure to measure the Specific Absorption Rate (SAR) for hand-held mobile wireless devices o IEC 62209-2:2019 Human exposure to RF fields from hand-held and body-mounted wireless devices - Human models, instrumentation, and procedures - Part 2: specific absorption rate (SAR) for wireless communication devices (30 MHz - 6 GHz) o D22-012-Tissue dielectric tissue calibration procedure o D28-002-Dipole procedure for validation of SAR system using a dipole o IEEE 1309 Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHz Conditions Ambient Temperature of the Laboratory: 21 C +/- 0.5C Temperature of the Tissue: 21 C +/- 0.5C Dipole Calibration uncertainty The calibration uncertainty for the dipole is made up of various parameters presented below. Tolerance, % Mechanical 2.00 Positioning Error 0.10 Electrical 0.37 Tissue Permittivity 3.88 Tissue Conductivity 3.56 Dipole Validation 1.70 Combined Uncertainty, k=2 4.81 NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 5 of 7 This page has been reviewed for content and attested to on Page 2 of this document. The Following Graphs are the results as displayed on the Vector Network Analyzer. Electrical Calibration Test Head S11 R/L -19.83 dB Impedance 43.26  SWR 1.23 U S11 Parameter Return Loss Head Frequency Range 2326.59 MHz to 2450 MHz NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 6 of 7 This page has been reviewed for content and attested to on Page 2 of this document. Smith Chart Dipole Impedance Head NCL Calibration Laboratories Division of APREL Laboratories DC-1904 Dipole SN: 825 Page 7 of 7 This page has been reviewed for content and attested to on Page 2 of this document. SWR Head 45461908 R2.0 Test Report Issue Date: 18 March 2024 ©2022 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 54 of 54 APPENDIX F - PHANTOM

RF Exposure Info

0.18 <0.1 1.60 1200 East 151 St. <0.1 Olathe, KS, 66062 <0.1 4.00 USA IC Registration NumberFCC ID: A04741 In Accordance With: A04741 General Pop. Limit: © 2024 Celltech Labs Inc, This report shall not be reproduced in any form without the expressed written consent of Celltech Labs Inc. Extremity (10g) - DSS: Product Model Number / HVINProduct Name / PMN Canada Test Lab Certificate: 2470.01 Approved By: IPH-04741 FCC Registration: CA3874 FCC 47 CFR §2.1093 Radiofrequency Radiation Exposure Evaluation: Portable Devices Ben Hewson, President Celltech Labs Inc. IC Registration 3874A 21-364 Lougheed Rd. Kelowna, BC, V1X 7R8 Applicant: Garmin International Inc. Test Report Serial Number: Test Report Date: SAR Test Report - New Application 1666 Project Number: Maximum reported SAR Body (1g) - DSS: General Pop. Limit: Maximum reported SAR Body (1g) - DTS: Extremity (10g) - DTS: W/kg W/kg 45461908 R3.0 11 April 2024 45461908 R3.0 Test Report Issue Date: 11 April 2024 ©2024 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc. Page 2 of 54 Table of Contents 1.0 REVISION HISTORY ........................................................................................................................................................ 4 2.0 CLIENT AND DEVICE INFORMATION ............................................................................................................................ 5 3.0 SCOPE OF EVALUATION ................................................................................................................................................ 6 4.0 NORMATIVE REFERENCES ........................................................................................................................................... 7 5.0 STATEMENT OF COMPLIANCE ..................................................................................................................................... 8 6.0 SAR MEASUREMENT SYSTEM ...................................................................................................................................... 9 7.0 RF CONDUCTED POWER MEASUREMENT ................................................................................................................ 10 TABLE 7.1 CONDUCTED POWER MEASUREMENTS, WIFI/BT ............................................................................................................................ 10 8.0 MEASUREMENT METHOD ............................................................................................................................................ 11 TABLE 8.1 NUMBER OF TEST CHANNELS AND SAR TEST REDUCTION .................................................................................................................. 11 TABLE 8.2 EXEMPTIONS FOR SINGLE RF SOURCE ............................................................................................................................................ 12 9.0 ACCESSORIES EVALUATED ........................................................................................................................................ 13 TABLE 9.1 MANUFACTURER’S ACCESSORY LIST .............................................................................................................................................. 13 10.0 SAR MEASUREMENT SUMMARY .............................................................................................................................. 14 TABLE 10.1: MEASURED RESULTS – BODY .................................................................................................................................................. 14 TABLE 10.2: MEASURED RESULTS – EXTREMITY ............................................................................................................................................ 15 11.0 SCALING OF MAXIMUM MEASURE SAR ................................................................................................................... 16 TABLE 11.1 SAR SCALING 1G .................................................................................................................................................................... 16 TABLE 11.2 SAR SCALING 10G .................................................................................................................................................................. 17 TABLE 11.2 SAR SCALING 10G (CONT.) ...................................................................................................................................................... 18 12.0 SAR EXPOSURE LIMITS ............................................................................................................................................. 19 TABLE 12.1 EXPOSURE LIMITS .................................................................................................................................................................... 19 13.0 DETAILS OF SAR EVALUATION ................................................................................................................................. 20 13.1 DAY LOG ........................................................................................................................................................................................ 20 13.2 DUT SETUP AND CONFIGURATION ....................................................................................................................................................... 21 13.3 DUT POSITIONING ........................................................................................................................................................................... 21 13.4 GENERAL PROCEDURES AND REPORT .................................................................................................................................................... 22 13.5 FLUID DIELECTRIC AND SYSTEMS PERFORMANCE CHECK .........................…

Text truncated - open the document above for the full version.

Test Report

Test Report 2024-019 Version C Issued 11 Apr 2024 Project GCL-0437 Model Identifier A04741 Primary Test Standard FCC Part 15.225 RSS-210 Issue 10 Amd 1 Garmin Compliance Lab Garmin International 1200 E 151 st Street Olathe Kansas 66062 USA Client-supplied Information FCC ID: IPH-04741 IC ID: 1792A-04741 See section 6 of this report regarding the presence or absence of accreditation logos or marks on this cover page. Page 2 of 26 GCL Test Report 2024-019 Version C This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 1. Summary The equipment or product described in section 5 of this report was tested at the Garmin Compliance Lab according to standards listed in section 6. This report focuses on the 13.56 MHz Near Field Communication (NFC) Transceiver(s). The results are as follows. Parameter Description Key Performance Values Result Data starts at page Radio Modulation Summary of the kinds of communication this radio can achieve, as stated by the client. [RSS-GEN at Annex A item 10b] Digitally modulated OOK and BPSK signaling at rates as high as 424 kbps. Reported N/A Transmitter intentional emissions Emissions while transmitting must be limited according to a mask that varies across the frequency range 13.110 to 14.010 MHz.[15.225(a) through (c), RSS-210 B.6] 45.2 dB of margin to the intentional emission limit. PASS 11 Transmitter spurious emissions Emissions beyond the intended radio band while transmitting must be suppressed a general limit. [FCC 15.225 (d) and RSS 210 B.6] 7.8 dB of margin to the Class B limit. PASS 15 Conducted Emissions AC Power Port Radio emissions that this device may generate via its ac power network connections that are not necessary for its operation and that may affect radio communication. [FCC Part 15.205 and RSS- GEN 8.8] 5.74 dB of margin to the appropriate limit. Tested 150 kHz to 30 MHz applying combined Class B limits. PASS 18 Frequency stability under extreme Conditions The ability for the radio to accurately maintain carrier frequency stable with changes in temperature and supply voltage. [FCC 15.225 (e) and RSS 210 B.6] The Carrier frequency was stable within 0.01% of the target frequency. PASS with caveat 21 Other Bandwidths Bandwidth values are presented for 99% Occupied Bandwidth There are requirements to report these numbers, but they do not have performance limits. Reported 23 NT (Not Tested) means the requirement may or may not be applicable, but the relevant measurement or test was not performed as part of this test project. N/A (Not Applicable) means the lab judged that the test sample is exempt from the requirement. Table 1: Summary of results Report Organization For convenience of the reader, this report is organized as follows: 1. Summary 2. Test Background 3. Report History and Approval 4. Test Sample Modifications and Special Conditions 5. Description of Equipment Tested 6. Test Standards Applied 7. Measurement Instrumentation Uncertainty 8. Selected Examples of Calculations 9. Environmental Conditions During Test 10. Immunity Performance Criteria Annex: Test records are provided for each type of test, following the order and page numbering stated in the summary table. Concluding notes appear on the final page of this report. Due to confidentiality, certain material (such as test setup photographs) has been removed from this report and placed in GCL Test Report 2024-017. That report is treated as a part of this document by way of this reference. Page 3 of 26 GCL Test Report 2024-019 Version C This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 2. Test Background The testing reported here was performed at the Garmin Compliance Lab, an organization within Garmin International, located at 1200 E 151 st St, Olathe Kansas, USA. The contact telephone number is +1.913.397.8200. The testing was performed on behalf of the Garmin design group, a separate organization located at 1200 E 151 st St, Olathe Kansas, USA. Witnesses from the business group included: None. Test Sample received: 06 Nov 2023 Test Start Date: 26 Jan 2024 Test End Date: 21 Feb 2024 The data in this test report apply only to the specific samples tested. Upon receipt all test samples were believed to be properly assembled and ready for testing. 3. Report History and Approval This report was written by Aditya Prakash and initially issued on 14 Mar 2024 as Version A. On 20 March 2024, Version B was created by Aditya Prakash to make some editorial changes. Version C was created by Dave Arnett on 11 Apr 2024 to remove certain photos, include an FVIN entry in section 5.2, and provide NB values . Report Technical Review: _________________________________________ David Arnett Technical Lead EMC Engineer Report Approval: _________________________________________ Shruti Kohli Manager Test and Measurement (EMC, Reliability and Calibration) 4. Test Sample Modifications and Special Conditions The following special conditions or usage attributes were judged during test to be necessary to achieve compliance with one or more of the standards listed in section 6 of this report: None The following modifications to the test sample(s) were made, and are judged necessary to achieve compliance with one or more of the standards listed in section 6 of this report: None Page 4 of 26 GCL Test Report 2024-019 Version C This report may be reproduced in whole. Reproduction of parts or excerpts requires lab management approval. Garmin 5. Description of the Equipment Tested 5.1 Unique Identification Product Model A04741 Serial Numbers Tested 457910369, 457910400, 457910428 This product tested is a Digital device and low power data transceiver. The client affirmed that the test samples will be representative of production in all relevant aspects. 5.2 Key Parameters EUT Input Power: 5 Vdc I/O Ports: USB / Docking port Radio Transceivers: IEEE 802.11 b/g/n, Bluetooth, Bluetooth Low Energy, …

Text truncated - open the document above for the full version.

Test Report

Antenna Data Sheet Antenna Manufacturer Information: The 2.4 GHz antenna for Garmin Model A04741 is custom designed and manufactured by Garmin International, Inc. (Garmin) with headquarters located at 1200 E. 151 st Street, Olathe, KS, 66062, USA. Garmin is an antenna manufacturer that specializes in antenna construction and has been a technology leader in high performance antenna design for over thirty years. State-of-the art equipment is used as described below to design, measure, and analyze new designs that are superior to competitor designs and highly proprietary in nature. Equipment Description: This data sheet contains the antenna gain information for the antenna for Garmin Model A04741. The approximate operational frequency band of these technologies is given, and the maximum gain within the frequency band is reported. Reported Data: Antenna Model Number Antenna Maximum Gain @ Frequency Antenna Approximate Frequency Band A04741-A1 2.51 dBi @ 2480 MHz 2402 to 2480 MHz Data Sheet Requirements: This data sheet contains the following, as required by the FCC’s Antenna Data Sheet Requirements (Refer to Page 4 of https://transition.fcc.gov/oet/ea/presentations/files/oct22/35-Part-15-Antenna-Updates- TCB_Oct_2022.pdf): • Name and Address of the Manufacturer • Model Number of the Antenna(s) • The Maximum Antenna Gain in the frequency band of operation Additional Information: Proprietary information regarding antenna design, dimensions, cable length, etc. are provided in the Confidential Operation Description exhibit.

Contact Information

Applicant

Ben Karsak(Manager, Compliance Engineering)
[email protected]9134401946Fax: 913 397-8282

Test Firm

Garmin Compliance LabShruti Kohli
[email protected]913 475 2911

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Garmin International Inc

IPH-04812

Mobile Digital Transceiver

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
IPH-A04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IPH-B04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IPH-A5168

Transceiver

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
IPH-A5172

Transceiver

Aug 25, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter