FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Garmin International Inc/
  3. IPH-A5126

IPH-A5126Portable Digital Transceiver

Garmin International Inc

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Sep 09, 2026
Application Purpose
Original Equipment
Equipment Note
Portable Digital Transceiver
Frequency Range
5180.00000000 - 5240.00000000
Company
Garmin International Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA July 1, 2026 Ref: Attestation Statements Part 2.911(d)(5) FCC ID: IPH-A5126 FRN: 0005088588 Garmin International, Inc., (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Garmin International, Inc., (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Garmin International, Inc., (“the applicant”) certifies that, the device does not have cybersecurity and/or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant after certification. Sincerely, Rick Jankovics Lead Compliance Engineer Garmin International, Inc.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 1, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: IPH-A5126 Garmin International, Inc., Garmin certifies that, as of the date of the filing of the application, Garmin International, Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Garmin International, Inc., accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Garmin International, Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: FRN: 0005088588 Name: Garmin International, Inc. Address: 1200 East 151 st Street, Olathe, Kansas, 66062 Contact Person: Ben Karsak Tel.: 913-440-1946 Email: [email protected] Sincerely, Rick Jankovics Lead Compliance Engineer Garmin International, Inc.

Cover Letter(s)

December 16, 2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Innovation, Science and Economic Development Canada Certification and Engineering Bureau 3701 Carling Avenue PO Box 11490, Station H Ottawa, Ontario, Canada K2H 8S2 To Whom It May Concern: Pursuant to 47 CFR 2.911, Garmin International, Inc. (Garmin) has authorized the following Garmin International Associates to act on Garmin's behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) and Innovation, Science and Economic Development Canada (ISED) for equipment authorization or certification. Mr. Niklas Haydon, Compliance Engineering Team Lead Ms. Sara Jones, Design Certification Engineer Mr. Mitchell Phillipi, Compliance Engineering Team Lead Mr. Jacky Yeung, Compliance Engineer Mr. William Pertner, Compliance Engineering Team Lead Mr. Hayden Pernia, Compliance Engineer Mr. Jay Everett, Compliance Engineering Team Lead Mr. Jeremiah Darden, Compliance Engineer Mr. Richard Kockelkoren, Compliance Engineer Mr. Henry Lin, Compliance Engineer Mr. Mike Moranha, Compliance Engineer Ms. Claire Fryman, Compliance Engineer Ms. Pam Sequeira, Compliance Engineer Mr. Rick Jankovics, Compliance Engineer Mr. Jeffrey Hailey, Compliance Engineer Mr. Brodie Halbfoster, Compliance Engineer Mr. Dan Irish, Compliance Engineer Ms. Silvia Spenny, Compliance Engineer Mr. Jonathan Shafer, Design Certification Engineer As such, the Garmin Associates listed above are authorized to: 1) sign Form 731, 2) sign letters of application, 3) request confidentiality, and 4) exchange data and information with the FCC, IC and/or authorized TCBs on behalf of Garmin. In addition, these individuals shall be considered "authorized individuals" to act on Garmin's behalf where an "authorized individual's" attestation is necessary or preferred. This authorization remains in effect until notified to the contrary by Garmin. Sincerely, Ben Karsak Manager Compliance Engineering Garmin International, Inc.

Cover Letter(s)

REQUEST FOR CONFIDENTIALITY Date: July 1, 2026 Applicant: Garmin International Subject: Confidentiality Request for FCC ID: IPH-A5126 IC: 1792A-A5126 Pursuant to FCC 47 CFR 0.457(d) and 0.459, and IC RSP-100 Section 12.4, we request that a part of the FCC and ISED application be held confidential. Type Of Confidentiality Requested Exhibit ☐ Short Term ☒ Permanent ☐ Not Provided Block Diagrams ☐ Short Term ☒ Permanent ☐ Not Provided Schematics ☐ Short Term ☒ Permanent ☐ Not Provided Operational Description/ Theory of Operation ☐ Short Term ☐ Permanent ☒ Not Provided Parts List & Placement/BOM ☐ Short Term ☒ Permanent ☐ Not Provided Tune-Up Procedure ☒ Short Term ☐ Permanent ☐ Not Provided Test Setup Photos ☒ Short Term ☐ Permanent ☐ Not Provided User’s Manual(s) ☒ Short Term ☐ Permanent ☐ Not Provided External Photos ☒ Short Term ☐ Permanent ☐ Not Provided Internal Photos Garmin International has spent a substantial effort in developing this product and it is one of the first of its kind in the industry. Having the subject information easily available to "competition" would negate the advantage we have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: Garmin requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality (if applicable): The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Sincerely, Rick Jankovics Lead Compliance Engineer

ID Label/Location Info

APPLICANT: Garmin Intl FCC ID: IPH-A5126 IC: 1792A-A5126 Exhibit 10: E-Label Information A. The following specific instructions are provided in the Quick Start Manual that ships with the device, which directs the user to the Owner’s Manual B. The following specific instructions are provided in the owner’s manual that is provided at www.garmin.com/manuals: Viewing E-label Regulatory and Compliance Information 1. Select Settings 2. Select Device. 3. Select Regulatory. Note: The FCC statement is clearly legible and can be read without the aid of magnification. Regulatory FCC ID: IPH-A5126 IC: 1792A-A5126 M/N: AA5126 APPLICANT: Garmin Intl FCC ID: IPH-A5126 IC: 1792A-A5126 C. The above information is programmed by Garmin and secure so that third-parties cannot modify it and the application or script allows for the regulatory information to be displayed correctly. 1. The regulatory information and dedicated exclusive application or script is secured and implemented in a factory-set-unalterable format. The regulatory information is capable of being retrieved and displayed locally, and under the control of the end user in possession of the product. 2. “No special accessories or supplemental plug-ins (e.g., installation of a SIM/USIM card) are required to access the information. Access to the information is provided without special codes, accessories, or permissions beyond the normal security protection to unlock the screen, sign-in page, or overall product access.” D. The above M/N, FCC ID, and IC numbers can be found printed on the product packaging.

RF Exposure Info

FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager Document S/N: 1M2606160048-01.IPH DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. Page 1 of 31 REV 22.0 03/30/2022 Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from Element. If you have any questions or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. Applicant Name: Date of Testing: Garmin International Inc. 06/29/2026 – 07/23/2026 1200 E. 151st Street Test Site/Location: Olathe, Kansas USA 66062 Element, Columbia, MD, USA Document Serial No.: 1M2606160048-01.IPH F C C I D : IPH-A5126 A P P L I C A N T : GAR MI N INT ER NA T IONAL I N C. DUT Type: Portable Digital Transceiver Application Type: Certification FCC Rule Part(s): CFR §2.1093 Model(s): AA5126 This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE C95.1-1992 and has been tested in accordance with the measurement procedures specified in Section 1.9 of this report; for North American frequency bands only. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Test results reported herein relate only to the item(s) tested. The SAR Tick is an initiative of the Mobile & Wireless Forum (MWF). While a product may be considered eligible, use of the SAR Tick logo requires an agreement with the MWF. Further details can be obtained by emailing: [email protected]. SAR 1g Body (W/kg) DTS2.4 GHz WIFI2412 - 2462 MHz 1.19 NII5 GHz WIFI U-NII-1: 5180 - 5240 MHz U-NII-2A: 5260 - 5320 MHz U-NII-2C: 5500 - 5720 MHz U-NII-3: 5745 - 5825 MHz 1.19 DSS2.4 GHz Bluetooth2402 - 2480 MHz 0.19 Equipment Class Tx FrequencyBand & Mode ELEMENT MATERIALS TECHNOLOGY, Columbia MD (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com RF EXPOSURE TEST REPORT FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager Document S/N: 1M2606160048-01.IPH DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. Page 2 of 31 REV 22.0 03/30/2022 Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from Element. If you have any questions or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. T A B L E O F C O N T E N T S 1 TEST LABORATORY INFORMATION..........................................................................................................4 2 DEVICE UNDER TEST .................................................................................................................................5 3 INTRODUCTION ........................................................................................................................................ 10 4 DOSIMETRIC ASSESSMENT ................................................................................................................... 11 5 TEST CONFIGURATION POSITIONS....................................................................................................... 12 6 RF EXPOSURE LIMITS ............................................................................................................................. 13 7 FCC MEASUREMENT PROCEDURES ..................................................................................................... 14 8 RF CONDUCTED POWERS ...................................................................................................................... 17 9 SYSTEM VERIFICATION ........................................................................................................................... 22 10 SAR DATA SUMMARY .............................................................................................................................. 24 11 SAR MEASUREMENT VARIABILITY ........................................................................................................ 26 12 EQUIPMENT LIST ...................................................................................................................................... 27 13 MEASUREMENT UNCERTAINTIES.......................................................................................................... 28 14 CONCLUSION ............................................................................................................................................ 29 15 REFERENCES ........................................................................................................................................... 30 APPENDIX A: SAR TEST PLOTS APPENDIX B: SAR DIPOLE VERIFICATION PLOTS APPENDIX C: PROBE AND DIPOLE CALIBRATION CERTIFICATES APPENDIX D: SAR TISSUE SPECIFICATIONS APPENDIX E: SAR SYSTEM VALIDATION APPENDIX F: DUT ANTENNA DIAGRAM AND SAR TEST SETUP PHOTOGRAPHS FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager Document S/N: 1M2606160048-01.IPH DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, plea…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX A A P P E N D I X A : S A R T E S T P L O T S A1 ELEMENT DUT: IPH-A5126; Type: Portable Digital Transceiver; Serial: 92W000039 Communication System: UID:10415, WLAN; MAIA: Y; Frequency: 2437.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 2437.000 MHz; cond = 1.79 S/m; perm = 38.5; density = 1000 kg/m3 Phantom Section: Flat; Space: 0.00 mm Test Date: 06/29/2026; Ambient Temp: 19.3°C; Tissue Temp: 20.9°C Probe: EX3DV4 - SN7539; ConvF:(7.12,6.76,7.63); Calibrated: 2026-03-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1450; Calibrated: 2026-03-10 Phantom: Twin-SAM V8.0; Serial: 1966 Measurement SW: DASY Module SAR V16.4.0.5005 Mode: 2.4 GHz WIFI/ IEEE 802.11b, Antenna A1, 22 MHz Bandwidth, Exp: Body| Back Side, Ch. 6, 1Mbps Area Scan (260.0 x 140.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (40.0 x 40.0 x 31.2): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Reference Value = 0.75 W/kg; Power Drift = -0.03 dB Peak SAR (extrapolated) = 2.66 W/kg SAR(1 g) = 0.965 W/kg Smallest distance from peaks to all points 3 dB below is 6.8 mm Ratio of SAR at M2 to SAR at M1 = 67.4 % A2 ELEMENT DUT: IPH-A5126; Type: Portable Digital Transceiver; Serial: 92V000199 Communication System: UID:10117 - AAD, WLAN; MAIA: Y; Frequency: 5230.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 5230.000 MHz; cond = 4.47 S/m; perm = 35.7; density = 1000 kg/m3 Phantom Section: Flat; Space: 0.00 mm Test Date: 07/13/2026; Ambient Temp: 22.0°C; Tissue Temp: 21.1°C Probe: EX3DV4 - SN3914; ConvF:(6.02,5.45,5.48); Calibrated: 2026-05-08 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn728; Calibrated: 2026-05-07 Phantom: Twin-SAM V8.0; Serial: 2065 Measurement SW: DASY Module SAR V16.4.0.5005 Mode: 5 GHz WIFI/ IEEE 802.11n, Antenna A2, 40 MHz Bandwidth, U-NII-1, Exp: Body| Back Side, Ch. 46, 13.5 Mbps Area Scan (260.0 x 140.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (28.8 x 28.8 x 22.9): Measurement grid: dx=3.6 mm, dy=3.6 mm, dz=1.4 mm; Graded Ratio: 1.4 Reference Value = 1.09 W/kg; Power Drift = -0.03 dB Peak SAR (extrapolated) = 5.51 W/kg SAR(1 g) = 1.13 W/kg Smallest distance from peaks to all points 3 dB below is 4.9 mm Ratio of SAR at M2 to SAR at M1 = 60.9 % A3 ELEMENT DUT: IPH-A5126; Type: Portable Digital Transceiver; Serial: 92V000199 Communication System: UID:10670 - CAA, Bluetooth; MAIA: Y; Frequency: 2440.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 2440.000 MHz; cond = 1.74 S/m; perm = 38.0; density = 1000 kg/m3 Phantom Section: Flat; Space: 0.00 mm Test Date: 07/23/2026; Ambient Temp: 22.2°C; Tissue Temp: 20.4°C Probe: EX3DV4 - SN7539; ConvF:(7.12,6.76,7.63); Calibrated: 2026-03-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1450; Calibrated: 2026-03-10 Phantom: Twin-SAM V8.0; Serial: 1966 Measurement SW: DASY Module SAR V16.4.0.5005 Mode: 2.4 GHz Bluetooth LE, Antenna A1, Exp: Body| Back Side, Ch. 17, 1 Mbps Area Scan (260.0 x 140.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (33.6 x 33.6 x 31.2): Measurement grid: dx=4.2 mm, dy=4.2 mm, dz=1.5 mm; Graded Ratio: 1.5 Reference Value = 0.09 W/kg; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.348 W/kg SAR(1 g) = 0.116 W/kg Smallest distance from peaks to all points 3 dB below is 5.7 mm Ratio of SAR at M2 to SAR at M1 = 63.5 %

RF Exposure Info

FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX B A P P E N D I X B : S A R D I P O L E V E R I F I C A T I O N P L O T S B1 ELEMENT DUT: Dipole 2450.000 MHz; Type: D2450V2 - SN797 Communication System: UID: 0, CW; Frequency: 2450.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 2450.000 MHz; cond = 1.80 S/m; perm = 38.5; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 06/29/2026; Ambient Temp: 19.3°C; Tissue Temp: 20.9°C Probe: EX3DV4 - SN7539; ConvF:(7.12,6.76,7.63); Calibrated: 2026-03-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1450; Calibrated: 2026-03-10 Phantom: Twin-SAM V8.0; Serial: 1966 Measurement SW: DASY Module SAR V16.4.0.5005 2450.0 MHz System Verification at 20.0 dBm (100 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 11.2 W/kg SAR(1 g) = 5.47 W/kg; SAR(10 g) = 2.57 W/kg Deviation (1 g) = 3.99%; Deviation (10 g) = 3.63% B2 ELEMENT DUT: Dipole 2450.000 MHz; Type: D2450V2 - SN797 Communication System: UID: 0, CW; Frequency: 2450.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 2450.000 MHz; cond = 1.75 S/m; perm = 38.0; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 07/23/2026; Ambient Temp: 22.2°C; Tissue Temp: 20.4°C Probe: EX3DV4 - SN7539; ConvF:(7.12,6.76,7.63); Calibrated: 2026-03-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1450; Calibrated: 2026-03-10 Phantom: Twin-SAM V8.0; Serial: 1966 Measurement SW: DASY Module SAR V16.4.0.5005 2450.0 MHz System Verification at 20.0 dBm (100 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=5.0 mm, dy=5.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 11.3 W/kg SAR(1 g) = 5.64 W/kg; SAR(10 g) = 2.66 W/kg Deviation (1 g) = 7.22%; Deviation (10 g) = 7.26% B3 ELEMENT DUT: Dipole 5250.000 MHz; Type: D5GHzV2 - SN1191 Communication System: UID: 0, CW; Frequency: 5250.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 5250.000 MHz; cond = 4.50 S/m; perm = 35.7; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 07/13/2026; Ambient Temp: 22.0°C; Tissue Temp: 21.1°C Probe: EX3DV4 - SN3914; ConvF:(6.02,5.45,5.48); Calibrated: 2026-05-08 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn728; Calibrated: 2026-05-07 Phantom: Twin-SAM V8.0; Serial: 2065 Measurement SW: DASY Module SAR V16.4.0.5005 5250.0 MHz System Verification at 17.0 dBm (50 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (24.0 x 24.0 x 22.9): Measurement grid: dx=4.0 mm, dy=4.0 mm, dz=1.4 mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 15.4 W/kg SAR(1 g) = 3.79 W/kg; SAR(10 g) = 1.09 W/kg Deviation (1 g) = -3.32%; Deviation (10 g) = -3.11% B4 ELEMENT DUT: Dipole 5600.000 MHz; Type: D5GHzV2 - SN1191 Communication System: UID: 0, CW; Frequency: 5600.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 5600.000 MHz; cond = 4.86 S/m; perm = 34.9; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 07/13/2026; Ambient Temp: 22.0°C; Tissue Temp: 21.1°C Probe: EX3DV4 - SN3914; ConvF:(5.21,4.72,4.74); Calibrated: 2026-05-08 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn728; Calibrated: 2026-05-07 Phantom: Twin-SAM V8.0; Serial: 2065 Measurement SW: DASY Module SAR V16.4.0.5005 5600.0 MHz System Verification at 17.0 dBm (50 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (24.0 x 24.0 x 22.9): Measurement grid: dx=4.0 mm, dy=4.0 mm, dz=1.4 mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.1 W/kg SAR(1 g) = 3.89 W/kg; SAR(10 g) = 1.11 W/kg Deviation (1 g) = 0.39%; Deviation (10 g) = -0.45% B5 ELEMENT DUT: Dipole 5750.000 MHz; Type: D5GHzV2 - SN1191 Communication System: UID: 0, CW; Frequency: 5750.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 5750.000 MHz; cond = 5.01 S/m; perm = 34.6; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 07/13/2026; Ambient Temp: 22.0°C; Tissue Temp: 21.1°C Probe: EX3DV4 - SN3914; ConvF:(5.37,4.86,4.88); Calibrated: 2026-05-08 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn728; Calibrated: 2026-05-07 Phantom: Twin-SAM V8.0; Serial: 2065 Measurement SW: DASY Module SAR V16.4.0.5005 5750.0 MHz System Verification at 17.0 dBm (50 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (24.0 x 24.0 x 22.9): Measurement grid: dx=4.0 mm, dy=4.0 mm, dz=1.4 mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.3 W/kg SAR(1 g) = 3.83 W/kg; SAR(10 g) = 1.10 W/kg Deviation (1 g) = 1.59%; Deviation (10 g) = 2.33% B6 ELEMENT DUT: Dipole 5850.000 MHz; Type: D5GHzV2 - SN1191 Communication System: UID: 0, CW; Frequency: 5850.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 5850.000 MHz; cond = 5.11 S/m; perm = 34.5; density = 1000 kg/m3 Phantom Section: Flat; Space: 10 mm Test Date: 07/13/2026; Ambient Temp: 22.0°C; Tissue Temp: 21.1°C Probe: EX3DV4 - SN3914; ConvF:(5.34,4.84,4.86); Calibrated: 2026-05-08 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn728; Calibrated: 2026-05-07 Phantom: Twin-SAM V8.0; Serial: 2065 Measurement SW: DASY Module SAR V16.4.0.5005 5850.0 MHz System Verification at 17.0 dBm (50 mW) Area Scan (40.0 x 80.0): Measurement grid: dx=10.0 mm, dy=10.0 mm Zoom Scan (24.0 x 24.0 x 22.9): Measurement grid: dx=4.0 mm, dy=4.0 mm, dz=1.4 mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.5 W/kg SAR(1 g) = 3.98 W/kg; SAR(10 g) = 1.12 W/kg Deviation (1 g) = 3.65%; Deviation (10 g) = 2.28%

RF Exposure Info

FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX D Page 1 of 2 A P P E N D I X D : S A R T I S S U E S P E C I F I C A T I O N S Measurement Procedure for Tissue verification: 1) The network analyzer and probe system was configured and calibrated. 2) The probe was immersed in the tissue. The tissue was placed in a nonmetallic container. Trapped air bubbles beneath the flange were minimized by placing the probe at a slight angle. 3) The complex admittance with respect to the probe aperture was measured 4) The complex relative permittivity ε ’ can be calculated from the below equation (Pournaropoulos and Misra): where Y is the admittance of the probe in contact with the sample, the primed and unprimed coordinates refer to source and observation points, respectively, ,  is the angular frequency, and . Figure D-1 Note: Liquid recipes are proprietary SPEAG. Since the composition is approximate to the actual liquids utilized, the manufacturer tissue-equivalent liquid data sheets are provided below. ( )          −  = b a b a r r d d d r r j a b j Y            0 2 / 1 0 ' 0 2 0 ) ( exp cos ln 2        −  + = cos 2 2 2 2 r 1 − = j FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Approved by: Technical Manager DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX D Page 2 of 2 Figure D-2 600 – 10000 MHz Head Tissue Equivalent Matter

RF Exposure Info

FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Error! Reference source not found. Approved by: Technical Manager DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX E: Page 1 of 1 A P P E N D I X E : S A R S Y S T E M V A L I D A T I O N Per FCC KDB Publication 865664 D02v01r02, SAR system validation status should be documented to confirm measurement accuracy. The SAR systems (including SAR probes, system components and software versions) used for this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue- equivalent media for system validation, according to the procedures outlined in FCC KDB Publication 865664 D01v01r04 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point, using the system that normally operates with the probe for routine SAR measurements and according to the required tissue-equivalent media. A tabulated summary of the system validation status including the validation date(s), measurement frequencies, SAR probes and tissue dielectric parameters has been included. Table E-1 SAR System Validation Summary NOTE: The probes have been calibrated for both CW and modulated signals. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01v01r04 for scenarios when CW probe calibrations are used with other signal types. SAR systems were validated for modulated signals with a periodic duty cycle, such as GMSK, or with a high peak to average ratio (>5 dB), such as OFDM according to FCC KDB Publication 865664 D01v01r04. SENSITIVITY PROBE LINEARITY PROBE ISOTROPY MOD. TYPE DUTY FACTOR PAR L 2450 3/30/2026 7539 1450 cDASY6 2450 1.856 37.819 PASS PASS PASS PASS OFDM/TDD PASS S 5250 6/9/2026 3914 728 DASY8 5250 4.487 34.834 PASS PASS PASS PASS OFDM N/A S 5600 6/9/2026 3914 728 DASY8 5600 4.843 34.176 PASS PASS PASS PASS OFDM N/A S 5750 6/10/2026 3914 728 DASY8 5750 4.995 33.911 PASS PASS PASS PASS OFDM N/A S 5850 6/10/2026 3914 728 DASY8 5850 5.107 33.723 PASS PASS PASS PASS OFDM N/A Perm. (εr) CW VALIDATION MOD. VALIDATION SAR System Freq. (MHz) Date Probe SN Probe Cal Point Cond. (σ) DAE

RF Exposure Info

FCC ID: IPH-A5126 RF EXPOSURE TEST REPORT Error! Reference source not found. Approved by: Technical Manager DUT Type: Portable Digital Transceiver This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX E: Page 1 of 1 A P P E N D I X E : S A R S Y S T E M V A L I D A T I O N Per FCC KDB Publication 865664 D02v01r02, SAR system validation status should be documented to confirm measurement accuracy. The SAR systems (including SAR probes, system components and software versions) used for this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue- equivalent media for system validation, according to the procedures outlined in FCC KDB Publication 865664 D01v01r04 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point, using the system that normally operates with the probe for routine SAR measurements and according to the required tissue-equivalent media. A tabulated summary of the system validation status including the validation date(s), measurement frequencies, SAR probes and tissue dielectric parameters has been included. Table E-1 SAR System Validation Summary NOTE: The probes have been calibrated for both CW and modulated signals. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01v01r04 for scenarios when CW probe calibrations are used with other signal types. SAR systems were validated for modulated signals with a periodic duty cycle, such as GMSK, or with a high peak to average ratio (>5 dB), such as OFDM according to FCC KDB Publication 865664 D01v01r04. SENSITIVITY PROBE LINEARITY PROBE ISOTROPY MOD. TYPE DUTY FACTOR PAR L 2450 3/30/2026 7539 1450 cDASY6 2450 1.856 37.819 PASS PASS PASS PASS OFDM/TDD PASS S 5250 6/9/2026 3914 728 DASY8 5250 4.487 34.834 PASS PASS PASS PASS OFDM N/A S 5600 6/9/2026 3914 728 DASY8 5600 4.843 34.176 PASS PASS PASS PASS OFDM N/A S 5750 6/10/2026 3914 728 DASY8 5750 4.995 33.911 PASS PASS PASS PASS OFDM N/A S 5850 6/10/2026 3914 728 DASY8 5850 5.107 33.723 PASS PASS PASS PASS OFDM N/A Perm.…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ben Karsak(Manager, Compliance Engineering)
[email protected]Fax: 913 397-8282

Technical Contact

Garmin International, Inc.Ben Karsak
[email protected]

1200 East 151st Street · Olathe, 66062 · United States

Test Firm

HCT America, Inc.Kent Kim
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz21.00 mW
215E5.26 GHz - 5.32 GHz14.00 mW
315E5.50 GHz - 5.70 GHz5.00 mW
415E5.75 GHz - 5.83 GHz12.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. The highest reported SAR is 1.19 W/kg. This device supports 20, 40 and 80 MHz bandwidth modes.

Other Applications from Garmin International Inc

IPH-05126

Portable Digital Transceiver

Sep 09, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
IPH-04812

Mobile Digital Transceiver

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
IPH-A04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IPH-B04825

Marine Stereo

Sep 01, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IPH-A5168

Transceiver

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System