Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Sep 05, 2001
Application Purpose
Original Equipment
Date of Application
Jun 24, 2001
Equipment Note
Alarmpath
Frequency Range
806.00000000 - 821.00000000
Company
CRN Wireless LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Install antenna as shown. Securely tighten screw. Slide antenna insulator grommet down to engage with hole on top of case. NOTE: If an antenna other than that supplied is used, it must have a antenna gain of 6 dBi or less in order to comply with the RF exposure warning. Refer to the antenna manufacturer specifications for details. WARNING: DO NOT APPLY POWER TO UNIT UNTIL ANTENNA IS INSTALLED! DAMAGE WILL OCCUR! 2 Apply 12VDC to screw terminals labeled “-“and “+”. Power supply must be able to handle a 3 AMP load. AP1 Installation Instructions 3 Wait 1 minute after power-up, then observe the Coverage LED. The LED will blink a number of times to indicate the network signal strength, as follows: # BLINK COVERAGE # BLINK COVERAGE 9 95% 4 70% 8 90% 3 65% 7 85% 2 60% 6 80% 1 55% 5 75% 0 50% CONSTANT RAPID BLINKING = NETWORK HAS ISSUED A SHUTDOWN COMMAND – CONTACT PROVIDER. Permanently mount the unit in a fixed, indoor location which provides at least 65% coverage. Always mount the unit at least 2 feet away from large metal objects and human beings. 4 Press the manual test button to send test signal to the Network. The coverage LED will blink rapidly for 3 seconds while the test signal is bein g sent. Confirm reception of signal with provider. 5 Trigger input channels. All input channels have an integration delay of 1 second. Default trigger method is voltage (5 to 15VDC). To change channels 1 to 4 trigger method to “Electronic Pull-to-Ground”, cut resistors R1 to R4, respectively. The coverage LED will blink rapidly for 3 seconds while the channel trigger signal is being sent. Confirm reception of signal with provider. 1 3 4 2 5 WARNING: To ensure user's safety and to satisfy FCC RF exposure requirements, this unit must be installed, so that a minimum separation distance of 34 cm is always maintained between the antenna of the transmitting device and nearby persons. Operation at closer than this distance is not recommended.

Cover Letter(s)

CRN TELEMETRY DEVICES, INC. 1515 MIDDLE COUNTRY ROAD CENTEREACH, NY 11720 June 21, 2001 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Authority to Act as an Agent to FCC Applicant: CRN Telemetry Devices, Inc. Product: Radio Modem Model: AP-1M FCC ID: ITC-AP-1 Dear Sir/Madam, I hereby appoint UltraTech Engineering Labs Inc. (UltraTech) to act as my agent in preparation of this application to F.C.C. for authourization of equipment under F.C.C. Rules. I also certify that the information provided, properly described the device or system for which authourization is required. Regards, Herbert Krieger President CRN Telemetry Devices, Inc. FCC LABELLING REQUIREMENTS AND INFORMATION TO USER Section 15.19 - Labelling Requirements - The device subject to Verification must be labelled as follows: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation - The device subject to Declaration of Conformity (DoC) must be labeled as follows: Where a device is constructed in two or more sections connected by wires and marketed together, the statement specified in this Section is required to be affixed only to the main control unit. (c) When the device is so small or for such use that it is not practicable to place the statement specified in this Section on it, the information required by these paragraphs shall be placed in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. However, the FCC identifier or the unique identifier, as appropriate, must be display on the device. If the Digital Portion of the EUT is computing devices and comply with FCC DoC Requirements, the following label is required: TRADE NAME MODEL NUMBER Tested to Comply With FCC Standards FOR HOME OR OFFICE USE Sections 15.21 & 15.105 - Information to User The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. (a) For a Class B digital device or peripheral, the instructions furnished the user shall include the following or similar statement, placed in a prominent location in the text of the manual. NOTE : This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by <manufacturer> could void the user’s authority to operate the equipment. (a) For a Class A digital device or peripheral, the instructions furnished the user shall include the following or similar statement, placed in a prominent location in the text of the manual. NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provided reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Warning : Changes or modifications not expressly approved by <manufacturer> could void the user’s authority to operate the equipment. FCC IDENTIFIER LABELING Note: XXX: Your company FCC grantee code MMM: Product identifier nunber This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation FCC ID: ITC-AP-1 Location of FCC Label – Example Only Show be an actual sample or photograph. If a drawing, show exact wording and label dimensions. Show exactly where on the EUT label is to be affixed FRONT EUT BOTTOM CHASSIS FCC ID LABEL

Cover Letter(s)

June 19, 2001 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Limited Modular Approval Application under FCC CFR 47, Parts 2 and 90 (Subpart I) - Non-Broadcast Radio Transceivers Operating in the frequency bands 806-821 MHz (25 kHz Channel Spacing). Applicant: CRN Telemetry Devices Inc. Product: Radio Modem Model: AP-1M FCC ID: ITC-AP-1 Dear Sir/Madam, As appointed agent for CRN Telemetry Devices Inc., we would like to submit the application to Federal Communications Commission for certification of the above product. This application is for a Limited Modular Approval. This device incorporates a radio modem manufactured by Research In Motion Ltd. (RIM), model 802D, FCC ID: L6AR802D-2-O. The radio modem module is supplied as a complete OEM unit, with no tuning or modifications required for operation in this device. UltraTech Engineering Labs Inc. will provide the following test data: • ERP calculations • MPE Evaluation • Transmitter Spurious/Harmonic emission measurements Details of all other test requirements and data will be provided by RIM. Please review all necessary files uploaded to the FCC OET site. This transmitter complies with FCC 2.1091 with the minimum calculated RF safety distance of 34 cm when used with an antenna having a maximum gain of 6 dBi. Please refer to the User’s Manual, for details of the antenna installation instructions and Section 6.6 of this test report for MPE evaluation data. If you have any queries, please do not hesitate to contact us by our TOLL FREE number: OUR TELEPHONE NO.: 1-877-765-4173 Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering TML/MT Encl. 2 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] UltraTech Group of Labs

Cover Letter(s)

RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 02400-CERT-FCC-COVER-021_mod2June 26, 2001 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21045 Reference :FCC ID : L6AR802D-2-O Subject :Letter requesting confidentiality of R802D-2-O radio modem device FCC Certification application . Pursuant to CFR 47 Chapter 1 Section 0.459, Research In Motion Limited (RIM) requests that the following identified detailed technical information regarding the R802D-2-O device be held confidential by the Federal Communication Commission (FCC) and as such be withheld from public inspection. RIM does not disclose proprietary confidential information about our products to any third parties and as such we request that the FCC does the same and forward the confidentiality acceptance letter to RIM. Our FCC submissions are considered proprietary confidential information. Pursuant to CFR 47 Chapter 1 Sections 0.457(d) and 0.457(d)(2)(i) the exhibits contain details of trade secrets and technical data that is customarily guarded from competitors and not released to the public by Research In Motion Limited. The specific parts of the Exhibits indicated in this letter are considered confidential by RIM and as such should be prevented from disclosure to public and competitors. RIM has taken necessary measures to have limited access to confidential documents only to RIM internal employees on a need-to-know basis, and have signed confidentiality agreements with employees. If the disclosure of such information is made public, it will cause serious competitive harm to RIM. Previously, none of the requested confidential Exhibits have been disclosed to third parties by RIM. The following Exhibits with specific sections described, submitted with the Form 731 Attachments should be held confidential: Exhibit Parts List/Tune Up InfoProcedur.doc “DOC-01606-007”, Users.doc “DOC-1606-006” CFR 47 Section 2.1033(c)(9) - Description of operational, test, and device tune-up technical procedure and operators’ manual. Section 010-10, CFR 47 Section 2.1033 (c) (10) - Description of Circuitry and Devices provided for: frequency stabilizing circuitry, suppression of spurious radiation, circuits for modulation limiting, and circuits for power limiting Exhibit Operational DescriptionSection 010-13 and 010-13-1, CFR 47 Section 2.1033 (c) (13) - Description of digital modulation format and necessary bandwidth Exhibit Parts List/Tune Up InfoSection 010-13-2 and 010-13-3, CFR 47 Section 2.1033 (c) (13) – Modulation generation methods and circuits. Detailed diagrams of modulation format and generation methods and circuits Exhibit Operational DescriptionSection 011-1 and 011-2, CFR 47 Section 2.1033 - Detailed system and functional description Exhibit Parts List/Tune Up InfoSection 011-3, CFR 47 Section 2.1033 - Detailed technical RF and power circuit description Exhibit Block Diagram02400-CERT-FCC-BLOCK-“R802D-2-O RADIO BLOCK”, CFR 47 Section 2.1033 – Detailed technical radio modem block diagram Exhibit Schematics“RIM 802D OEM DataTAC - AMSC” SCH-02400-001 Rev B, CFR 47 Section 2.1033 (c) (10) - Complete technical schematic circuit diagrams Yours truly, MasudS.Attayi,P.Eng. Senior Certification Engineer Research In Motion Limited ( 519 ) 888 – 7465 x2442 [email protected] RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 02400-CERT-FCC-Cover-022_modJune 26, 2001 Federal Communications Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd. Columbia, Md. 21046 FCC ID:L6AR802D-2-O Subject:FCC Part 90 Certification Application for Research In Motion Limited, Model R802D-2-O This is to inform that Research In Motion is submitting the technical documentation of our radio modem Model R802D-2-O (existing FCC ID: L6AR802D-2-O ) in support of the application for Certification of our integrator, CRN Wireless, with FCC ID ITCAP-1 The Model R802D-2-O is a radio modem intended for integration into other equipment to allow wireless data communication. All required documents in compliance with Parts 2 and 90 of the FCC Rules have been provided in the attached Exhibits. Research In Motion would like to request confidentiality as indicated in the Form 731, Item 8 and as requested in the letter Ref: CERT-01677-021_mod2, under Exhibit “Covering Letters”. Please do not hesitate to call at (519) 888-7465 x2442 or email at [email protected] should you require additional information or have any questions. Yours truly, MasudS.Attayi,P.Eng. Senior Certification Engineer Research In Motion Limited ( 519 ) 888 – 7465 x2442 [email protected]

Cover Letter(s)

2 3000 Bristol Circle Oakville, Ontario Canada, L6H 6G4 Telephone (905) 569-2550 Facsimile (905) 569-2480 Web Site: www.ultratech-labs.com Email: [email protected] July 4, 2001 Federal Communications Commission FCC Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 USA Attn.: Ms. Linda Elliot Re: FCC ID: ITCAP-1 Applicant: CRN Telemetry Devices, Inc. Correspondence Reference Number: 19848 731 Confirmation Number: EA101473 Dear Ms. Elliot, This letter is our reply to the Above Referenced Number. The correct FCC ID is ITC-AP-1. Please revise Form 731 as necessary. All uploaded documents reference the correct FCC ID, thus no further revisions to those documents are required. Contact information for the applicant is as follows: Name: Herb Krieger Telephone: 631-696-2769 Fax: 631-698-7943 Email: [email protected] If you have any queries, please do not hesitate to contact us. Yours truly, Tri M. Luu, P. Eng. V.P., Engineering Encl. TML/MT UltraTech Group of Labs

External Photos

CRN TELEMENTRY DEVICES FCC ID: ITC-AP-1 RADIO MODEM TRANSCEIVER MODEL: AP-1M PHOTO #1 TOP VIEW CRN TELEMENTRY DEVICES FCC ID: ITC-AP-1 RADIO MODEM TRANSCEIVER MODEL: AP-1M PHOTO #2 REAR VIEW CRN TELEMENTRY DEVICES FCC ID: ITC-AP-1 RADIO MODEM TRANSCEIVER MODEL: AP-1M PHOTO #3 FRONT VIEW

ID Label/Location Info

CRN AP-1 LABEL LOCATION FCC ID LABEL AND LOCATION ON RADIO MODEM FCC LABEL AND LOCATION ON THE FINAL ASSEMBLY Front of Unit ALARMPATH CRN TELEMETRY DEVICES, INC. FCC ID: ITC-AP-1 Contains Transceiver Module SERIAL #: 00001

Internal Photos

CRN TELEMENTRY DEVICES FCC ID: ITC-AP-1 RADIO MODEM TRANSCEIVER MODEL: AP-1M PHOTO #4 TOP VIEW – COVER OPEN CRN TELEMENTRY DEVICES FCC ID: ITC-AP-1 RADIO MODEM TRANSCEIVER MODEL: AP-1M PHOTO #5 BACK VIEW – COVER OPEN

RF Exposure Info

FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS Page 10 Radio Modem, Model AP-1M FCC ID: ITC-AP-1 ULTRATECH GROUP OF LABS File #: CRN02_90 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 June 19, 2001 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA ) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST 6.6. RF EXPOSURE REQUIRMENTS @ 1.1310 & 2.1091 6.6.1. Limits ƒ FCC 1.1310:- The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b). LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) (A) Limits for Occupational/Control Exposures 300-1500 ... ... F/300 6 1500-100,000 ... ... 5 6 (B) Limits for General Population/Uncontrolled Exposure 300-1500 ... ... F/1500 6 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 6.6.2. Method of Measurements Refer to FCC @ 1.1310, 2.1091 and Public Notice DA 00-705 (March 30, 2000) • In order to demonstrate compliance with MPE requirements (see Section 2.1091), the following information is typically needed: (1) Calculation that estimates the minimum separation distance (20 cm or more) between an antenna and persons required to satisfy power density limits defined for free space. (2) Antenna installation and device operating instructions for installers (professional/unskilled users), and the parties responsible for ensuring compliance with the RF exposure requirement (3) Any caution statements and/or warning labels that are necessary in order to comply with the exposure limits (4) Any other RF exposure related issues that may affect MPE compliance FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS Page 11 Radio Modem, Model AP-1M FCC ID: ITC-AP-1 ULTRATECH GROUP OF LABS File #: CRN02_90 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 June 19, 2001 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA ) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST Calculation Method of RF Safety Distance : S = PG/4Πr 2 Where: P: power input to the antenna in mW EIRP: Equivalent (effective) isotropic radiated power. S: power density mW/cm 2 G: numeric gain of antenna relative to isotropic radiator r: distance to centre of radiation in cm r = PG/4ΠS FCC radio frequency exposure limits may not be exceeded at distances closer than r cm from the antenna of this device Calculation Example using a 6 dBi antenna gain For General Population/Uncontrolled Exposure, Power Density (S) = F/1500 mW/cm 2 For the operating frequency range of 806-821 MHz for this device, F = lowest operating frequency of 806 MHz, therefore Power Density (S) = 806/1500 = 0.537 mW/cm 2 P = 32.7 dBm = 1862.088 mW G = 6 dBi = 10 (6/10) = 3.98 numeric S = 0.537 mW/cm 2 Since r = PG/4ΠS Then r = 1862.088 mW x 3.98 numeric / 4 x Π x S = 34 cm Therefore, the minimum separation distance of 34 cm (with antenna gain equal to or less than 6 dBi) is necessary to comply with RF Exposure requirements. The following RF exposure warning statement will be placed in the installation manual. RF Exposure Warning: To ensure user’s safety and to satisfy RF exposure requirements, this unit must be installed so that a minimum separation distance of 34 cm is always maintained between the antenna of the transmitting device and the body of nearby persons. Operations at closer than this distance is not recommended. FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS Page 12 Radio Modem, Model AP-1M FCC ID: ITC-AP-1 ULTRATECH GROUP OF LABS File #: CRN02_90 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 June 19, 2001 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA ) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST 6.6.3. Test Data Maximum Antenna Gain (G) (dBi) Frequency (MHz) Measured Conducted Power (P) (dBm) Calculated Minimum RF Safety Distance r (cm) Laboratory’s Recommended Minimum RF Safety Distance r (cm) 6 806.0 32.4 32.0 34 6 813.5 32.6 32.8 34 6 821.0 32.7 33.1 34 Note 1 : RF EXPOSURE DISTANCE LIMITS: r = PG/4ΠS Evaluation of RF Exposure Compliance Requirements RF Exposure Requirements Compliance with FCC Rules Minimum calculated separation distance between antenna and persons required: 34 cm Manufacturer’ instruction for separation distance between antenna and persons required: 34 cm. Please refer to the User’s Manual and FCC RF Exposure folder Caution statements and/or warning labels that are necessary in order to comply with the exposure limits Please refer to the Users/ Manual and FCC RF Exposure folder Any other RF exposure related issues that may affect MPE compliance None.

Test Report

Radio Modem Model No.: AP-1M FCC ID: ITC-AP-1 Applicant: CRN Telemetry Devices Inc. 1515 Middle Country Road Centerreach, NY USA, 11720 Tested in Accordance With Federal Communications Commission (FCC) CFR 47, PARTS 2 and 90 (Subpart I) UltraTech's File No.: CRN02_90 This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: ........................... Report Prepared by: Mike Tom Tested by: Hung Trinh, RFI Engineer Issued Date: June 19, 2001 Test Dates: June 4, 2001 • The results in this Test Report apply only to the sample(s) tested, which was randomly selected. • Under no circumstances may this report be used by the client to claim product endorsement by NVLAP or any agency of the US Government. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS Contents i Radio Modem, Model AP-1M FCC ID: ITC-AP-1 ULTRATECH GROUP OF LABS File #: CRN02_90 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 June 19, 2001 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA ) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST TABLE OF CONTENTS EXHIBIT 1. SUBMITTAL CHECK LIST ............................................................................................................1 EXHIBIT 2. INTRODUCTION ............................................................................................................................ 2 2.1. SCOPE ...................................................................................................................................................... 2 2.2. RELATED SUBMITAL(S)/GRANT(S)........................................................................................................ 2 2.3. NORMATIVE REFERENCES.................................................................................................................... 2 EXHIBIT 3. PERFORMANCE ASSESSMENT.................................................................................................. 3 3.1. CLIENT INFORMATION............................................................................................................................ 3 3.2. EQUIPMENT UNDER TEST (EUT) INFORMATION ................................................................................ 3 3.3. EUT’S TECHNICAL SPECIFICATIONS.................................................................................................... 4 3.4. L IST OF ANCILLARY EQUIPMENT .......................................................................................................... 4 EXHIBIT 4. EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS ........................... 5 4.1. CLIMATE TEST CONDITIONS ................................................................................................................. 5 4.2. OPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TEST SIGNALS................................... 5 EXHIBIT 5. SUMMARY OF TEST RESULTS ................................................................................................... 6 5.1. LOCATION OF TESTS.............................................................................................................................. 6 5.2. APPLICABILITY & SUMMARY OF EMC EMISSION TEST RESULTS.................................................... 6 5.3. MODIFICATIONS INCORPORATED IN THE EUT FOR COMPLIANCE PURPOSES ............................ 6 EXHIBIT 6. MEASUREMENTS, EXAMINATIONS & TEST DATA FOR EMC EMISSIONS............................ 7 6.1. TEST PROCEDURES ............................................................................................................................... 7 6.2. MEASUREMENT UNCERTAINTIES ........................................................................................................ 7 6.3. MEASUREMENT EQUIPMENT USED: ....................................................................................................7 6.4. ESSENTIAL/PRIMARY FUNCTIONS AS DECLARED BY THE MANUFACTURER: .............................. 7 6.5. RF POWER OUTPUT @ FCC 2.1046 & 90.205....................................................................................... 8 6.5.1. Limits @ FCC 90.205 ......................................................................................................................... 8 6.5.2. Method of Measurements................................................................................................................... 8 6.5.3. Test Equipment List............................................................................................................................ 8 6.5.4. Test Arrangement............................................................................................................................... 8 6.5.5. Test Data ............................................................................................................................................ 9 6.6. RF EXPOSURE REQUIRMENTS @ 1.1310 & 2.1091........................................................................... 10 6.6.1. Limits ................................................................................................................................................ 10 6.6.2. Method of Measurements................................................................................................................. 10 6.6.3. Test Data ...................................................…

Text truncated - open the document above for the full version.

Test Report

FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS Page 3 Radio Modem, Model AP-1M FCC ID: ITC-AP-1 ULTRATECH GROUP OF LABS File #: CRN02_90 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 June 19, 2001 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA ) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST EXHIBIT 3. PERFORMANCE ASSESSMENT 3.1. CLIENT INFORMATION APPLICANT Name: CRN Telemetry Devices Inc. Address: 1515 Middle Country Road Centerreach, NY USA, 11720 Contact Person: Mr. Herb Krieger Phone #: 631-696-2769 Fax #: 631-698-7943 Email Address: [email protected] MANUFACTURER Name: Research In Motion Ltd. Address: 295 Philip Street Waterloo, Ontario Canada, N2L 3W8 Contact Person: Mr. Masud Attayi Phone #: 519-888-7465, ext. 2442 Fax #: 519-888-6906 Email Address: [email protected] 3.2. EQUIPMENT UNDER TEST (EUT) INFORMATION The following information (with the exception of the Date of Receipt) has been supplied by the applicant. Brand Name: CRN Telemetry Devices Inc. Product Name: Radio Modem Model Name or Number: AP-1M Serial Number: Pre-Production Type of Equipment: Non-Broadcast Radio Communication Equipment External Power Supply: Yes, 12Vdc Transmitting/Receiving Antenna Type: Non-integral Primary User Functions of EUT: Alarm reporting device that monitors up to four contact closures or contact open inputs and transmits these signals to a receiver when one of these contacts are activated

Test Report

ELECTROMAGNETIC EMISSIONS TEST REPORT BY COM-SERVE CORPORATION KITCHENER, ONTARIO CANADA RESULTS R802D-2-O RIM 025 COMPLIANCE (yes) (no) RF POWER OUTPUT Transmitter: 2.1046 ( X ) ( ) OCCUPIED BANDWIDTH Transmitter: 2.1049 (N/T) ( ) SPURIOUS EMISSIONS AT THE ANTENNA TERMINALS Transmitter: 2.1051 (N/T) ( ) FIELD STRENGTH OF SPURIOUS RADIATION Transmitter: 2.1053 ( X ) ( ) FREQUENCY STABILITY Transmitter: 2.1055 (N/T) ( ) BANDWIDTH LIMITATIONS Transmitter:90.210 g (N/T) ( ) SYSTEM DESCRIPTION RIM 025 The R80…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Richard Moreau
[email protected]631-696-2769Fax: 631-698-7943

Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

3000 Bristol Circle · Oakville, Ontario · Canada

Non-Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

Test Firm

UltraTech Engineering Labs Inc.Tri Luu
[email protected]877-747-6381Fax: 905-829-8050

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
190806 MHz - 821 MHz2 W20K0F1D2.5000000000 ppm
Confidentiality
Long Term

Other Applications from CRN Wireless LLC

Alarmpath Echo Wireless Subscriber Unit - FCC ID ITC-AP-4700V - CRN Wireless LLC
ITC-AP-4700V

Alarmpath Echo Wireless Subscriber Unit

Jun 09, 2005

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
AlarmPath Echo - FCC ID ITC-AP-4700 - CRN Wireless LLC
ITC-AP-4700

AlarmPath Echo

May 09, 2002

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
ITCCRNTU

TNB - Licensed Non-Broadcast Station Transmitter

Jul 09, 1996

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
ITCCRNVHF

TNB - Licensed Non-Broadcast Station Transmitter

Nov 25, 1991

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
ITCCRNUHF

TNB - Licensed Non-Broadcast Station Transmitter

May 15, 1991

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter