Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Caution Guide / Wireless Noise-Cancelling Headphones Guide de mise en garde / Casque sans fil atténuateur de bruit Sicherheitsanweisungen / Kabellose Kopfhörer mit Geräuschunterdrückung Guida precauzionale / Cuffie wireless antirumore Guía de precauciones / Auriculares inalámbricos con cancelación de ruido Guia de precauções de segurança / Fones de ouvido sem fio com cancelamento de ruído Руководство по мерам предосторожности / Беспроводные шумоизолирующие наушники 注意事项指南 / 无线降噪耳机 注意事項 / 無線降噪耳機 주의사항�안내 / 무선�노이즈�캔슬링�헤드폰 ATH-ANC300TW English Thank you for purchasing this Audio-Technica product. Before using the product, read through this caution guide to ensure that you will use the product correctly. Please keep this manual for future reference. Safety precautions Although this product was designed to be used safely, failing to use it correctly may result in an accident. To ensure safety, observe all warnings and cautions while using the product. Cautions for the headphones • Do not use the product near medical equipment. Radio waves may affect cardiac pacemakers and medical electronic equipment. Do not use the product inside medical facilities. • When using the product in aircraft, follow airline instructions. • Do not use the product near automatic control devices such as automatic doors and fire alarms. Radio waves may affect electronic equipment and cause accidents due to malfunction. • Do not disassemble, modify or attempt to repair the product to avoid electric shock, malfunction or fire. • Do not subject the product to strong impact to avoid electric shock, malfunction or fire. • Do not handle the product with wet hands to avoid electric shock or injury. • Disconnect the product from a device if the product begins to malfunction, producing smoke, odor, heat, unwanted noise or showing other signs of damage. In such a case, contact your local Audio-Technica dealer. • Do not allow the product to get wet to avoid electric shock or malfunction. • Do not put foreign matter such as combustible materials, metal, or liquid in the product. • Do not cover the product with a cloth to avoid fire or injury by overheating. • Follow applicable laws regarding mobile phone and headphone use if using headphones while driving. • Do not use the product in places where the inability to hear ambient sound presents a serious risk (such as at railroad crossings, train stations, and construction sites). • The product effectively shields external sound, so you may not hear sound around you clearly while wearing the product. Adjust the volume to a level where you can still hear background sound and monitor the area around you while listening to music. • Store the product out of the reach of small children. • To prevent damage to your hearing, do not raise the volume too high. Listening to loud sound for an extended period may cause temporary or permanent hearing loss. • Discontinue use if skin irritation results from direct contact with the product. • If you begin to feel unwell while using the product, discontinue use immediately. • When removing the product from your ears, check to make sure the eartips are still attached to the main unit. If the eartips become lodged in your ears and you are unable to remove them, consult a physician at once. • If you develop an itch from wearing the product, discontinue use. Cautions for charging case • Do not disassemble, modify or attempt to repair the product to avoid electric shock, malfunction or fire. • Do not subject the product to strong impact to avoid electric shock, malfunction or fire. • Do not handle the product with wet hands to avoid electric shock or injury. • Disconnect the product from a device if the product begins to malfunction, producing smoke, odor, heat, unwanted noise or showing other signs of damage. In such a case, contact your local Audio-Technica dealer. • Do not allow the product to get wet to avoid electric shock or malfunction. • Do not put foreign matter such as combustible materials, metal, or liquid in the product. • Do not cover the product with a cloth to avoid fire or injury by overheating. • When charging, make sure to use the included USB charging cable. • Do not charge with devices that have quick-charge functionality (with a voltage of 5 V or more). Doing so may cause the product to malfunction. • Do not store the product in direct sunlight, near heating devices, or in hot, humid, or dusty places because such storage could cause malfunction or defect. • Do not put it close to fire because that could cause deformation or malfunction. • Do not use benzine, paint thinners and electrical contact cleaner, etc. because use of such material could cause deformation or malfunction. Cautions for rechargeable battery The headphones are equipped with a rechargeable battery (lithium ion battery). The charging case is equipped with a rechargeable battery (lithium polymer battery). • If battery fluid gets into eyes, do not rub them. Rinse thoroughly with clean water such as tap water and consult a doctor immediately. • If battery fluid leaks, do not touch fluid with bare hands. If fluid remains inside the product, it may cause malfunction. If battery fluid leaks, contact your local Audio- Technica dealer. –If fluid gets in your mouth, gargle thoroughly with clean water such as tap water and consult a doctor immediately. –If your skin or clothing comes in contact with fluid, immediately wash the affected skin or clothing with water. If you experience skin irritation, consult a doctor. • To avoid leakage, generation of heat or explosion: –Never heat, disassemble or modify the battery, nor dispose of it in a fire. –Do not attempt to pierce with a nail, hit with a hammer or step on the battery. –Do not drop the product or subject it to strong impact. –Do not get the battery wet. • Do not use, leave or store the battery in the following places: –Area exposed to direct sunlight or high temperatures and humidity –Inside of a car under the blazing sun –…
Text truncated - open the document above for the full version.
EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co.,Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 6 Charging Case EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co.,Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 6 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co.,Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 6 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co.,Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 6 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co.,Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 6 Headphones EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co.,Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 6 of 6
As the product is not big enough to put label information on product, please refer to label statement in P1 and FCC ID in P4 in user manual Part 3. FCC statement in user manual: FCC ID in user manual:
EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 2 BT Antenna EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 2
68.950.20.0014.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 RF exposure Estimation 1.Introduction Product: WIRELESS HEADPHONES Model no.: ATH-ANC300TW FCC ID: JFZANC300TW-R The EUT is WIRELESS HEADPHONES, which contain Bluetooth function inside. 2.Limit and Guidelines on Exposure to Electromagnetic Fields According to§15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 Mobile Portable RF Exposure v05r02, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. 3.Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 Conducted Power + tune up tolerance =4.36dBm= 2.73mW Distance = 5 mm f = 2.402 GHz [2.73/5] * SQRT (2.402) =0.846 0.846≤ 3.0 Therefore, excluded from SAR testing. - TÜV SÜD Shenzhen LTD. - Reviewed by: Prepared By: Mark Chen/EMC Project Manager Mark Chen/EMC Project Engineer Date: 2020-03-03 Date: 2020-03-03
Report Number:68.950.20.0014.01 EMC_SZ_FR_21.00FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District Shenzhen 518052, P.R. China Page 1 of 49 FCC - TEST REPORT Report Number:68.950.20.0014.01Date of Issue:February 27, 2020 Model:ATH-ANC300TW Product Type:WIRELESS HEADPHONES Applicant:Audio-Technica Corporation Address:2-46-1 Nishi-naruse, Machida Tokyo 194-8666 Japan Factory:Charter Media (Dongguan) Co., Ltd. Address:Dabandi Industrial Zone, Daning District, Humen Town, :523930 Dongguan City, Guangdong Province, :PEOPLE’S REPUBLC OF CHINA Test Result:nPositiveoNegative Total pages including Appendices:49 TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. SHENZHEN BRANCH is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. SHENZHEN BRANCH reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. SHENZHEN BRANCH shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. SHENZHEN BRANCH issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number:68.950.20.0014.01 EMC_SZ_FR_21.00FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District Shenzhen 518052, P.R. China Page 2 of 49 1 Table of Contents 1Table of Contents ........................................................................................................................................................... 2 2Details about the Test Laboratory.................................................................................................................................... 3 3Description of the Equipment Under Test ........................................................................................................................ 4 4Summary of Test Standards ............................................................................................................................................ 5 5Summary of Test Results ................................................................................................................................................ 6 6General Remarks ............................................................................................................................................................ 7 7Test Setups ..................................................................................................................................................................... 8 8Systems test configuration .............................................................................................................................................. 9 9Technical Requirement ................................................................................................................................................. 10 9.1Conducted peak output power ............................................................................................................................... 10 9.220 dB bandwidth and 99% Occupied Bandwidth ................................................................................................... 17 9.3Carrier Frequency Separation ............................................................................................................................... 27 9.4Number of hopping frequencies ............................................................................................................................ 30 9.5Dwell Time .......................................................................................................................................................... 32 9.6Spurious RF conducted emissions ......................................................................................................................... 35 9.7Band edge testing ................................................................................................................................................. 39 9.8Spurious radiated emissions for transmitter ........................................................................................................... 44 10Test Equipment List...................................................................................................................................................... 48 11System Measurement Uncertainty ................................................................................................................................. 49 Report Number:68.950.20.0014.01 EMC_SZ_FR_21.00FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District Shenzhen 518052, P.R. China Page 3 of 49 2 Details about the Test Laboratory Details about the Test Laboratory Test Site1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District Shenzhen 518052 P.R. Ch…
Text truncated - open the document above for the full version.
Radiated Emission Test below 1GHz Radiated Emission Test 1GHz-18GHz Radiated Emission Test 18GHz-40GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.73 mW |
DESK STAND TRANSMITTER
Equipment Class
DWM - Part 15 Wireless MicrophoneUniPak Transmitter
Equipment Class
TLD - Licensed LPAS DeviceHandheld Transmitter
Equipment Class
TLD - Licensed LPAS DeviceWireless Headphones
Equipment Class
DTS - Digital Transmission SystemWireless Headphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter