FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nisshin Industry Co Ltd/
  3. JHU655N

JHU655NMICROWAVE OVEN-HOUSEHOLD

Nisshin Industry Co Ltd
MICROWAVE OVEN-HOUSEHOLD - FCC ID JHU655N - Nisshin Industry Co Ltd
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Nov 14, 2005
Application Purpose
Original Equipment
Date of Application
Sep 28, 2005
Equipment Note
MICROWAVE OVEN-HOUSEHOLD
Frequency Range
2400.00000000 - 2500.00000000
Company
Nisshin Industry Co Ltd
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗
↗
↗
↗

Block Diagram

↗
↗

Cover Letter(s)

↗

External Photos

↗
↗
↗
↗
↗
↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗
↗
↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

TO: FEDERAL COMMUNICATIONS COMMISSION SEPTEMBER 30, 2005 OET 7435 OAKLAND MILLS ROAD COLUMBIA, MD 21046 RE: FCC ID: JHU655N, NEW HOUSEHOLD MICROWAVE OVEN, 0.6 CU FT, 600W OUTPUT. (EA414938) TO WHOM IT MAY CONCERN, WE HAVE SUBMITTED OUR 731 FORM, AND FEES BY CREDIT CARD, ELECTRONICALLY, ALONG WITH THE REQUIRED EXHIBITS. WE WISH TO APPLY FOR A GRANT OF CERTIFICATION USING A PANASONIC MAGNETRON, 2M211A-M2J. THE TEST REPORTS SUBMITTED ARE APPLICABLE TO ANY MICROWAVE OVEN BEARING THE SUBJECT FCC ID. THE OVEN ELECTRICAL SPECS ARE AS FOLLOWS; INPUT; 120 V AC, 60 HZ, 1030 W OUTPUT; 600W, 2450 MHZ, +/- 50 MHZ. WE ASK THAT YOU PLEASE NOTE THAT THIS OVEN COMPLIES WITH THE NEW FCC REQUIREMENTS EFFECTIVE JULY 2004. BOTH FCC AND CISPR TEST REPORTS WERE SUBMITTED. WE APOLOGIZE FOR THE RATHER POOR QUALITY OF SOME OF THE PHOTOS, AND WILL SUBMIT BETTER QUALITY IN FUTURE FCC SUBMISSIONS. SHOULD YOU HAVE ANY QUESTIONS, OR NEED ADDITIONAL EXHIBITS, PLEASE FREE TO CONTACT US. THANK YOU. VERY TRULY, THOMAS L. FARINA, PRESIDENT NISSHIN INDUSTRY CO., LTD. (USA) 645 DAUPHINE CT, SUITE D ELK GROVE, IL 60007 TEL 847-640-8120, FAX 847-640–0186 EMAIL [email protected]

Test Report

MAGNETRON ENGINEERING & QUALITY ASSURANCE GROUP, ELECTRON TUBES DIVISION 1975, 23-CHOME MINAMI 5-JODORI, ASAHIKAWA, HOKKAIDO 078-8335, JAPAN PHONE : +81-166-31-4728 FACSIMILE : +81-166-31-4739 Mr. R. Kanemitsu Deputy General Manager Research & Development DepartmentReport No. : 05-107 Crystal Electric Co., Ltd.Issued date : September 20, 2005 3-22-5, Higashinakamoto, Higashinari-ku, Osaka 537-0021, Japan Dear R. Kanemitsu, We are enclosing the above mentioned EMI test results based on FCC Part 18 in our measuring facility. Please feel free to contact us, if you have any question or request. Sincerely yours, Toshiki Azuma Group Manager Magnetron Engineering & Quality Assurance Group Electron Tubes Division AZ/HR cc : Re : EMI test result in your model MFM-1NTPS MWO with Panasonic magnetron 2M211A-M2J Report No. : 05-107 Issued date : September 20, 2005 Page: 2 of 11 1.Test site Name: Toshiba Hokuto Electronics Corporation Magnetron Engineering & Quality Assurance Group, Electron Tubes Division Laboratory for EMI measurements Address: 1975-Banchi, 23-Chome, Minami 5-Jodori, Asahikawa 078-8335 Japan FCC registration number: 741626 (Date of listing: August 23, 2004) 2.Specification of EUT Manufacturer: Crystal Electric Co., Ltd. Equipment: Microwave oven Model No.: MFM-1NTPS Line voltage: 120V/60Hz Rating output power: 600W (IEC 60705) Magnetron: PANASONIC 2M211A-M2J 3.Test specification Test specification: FCC Part 18 Equipment classification: Consumer ISM equipment Test procedure: FCC/OST MP-5 4.Test result 4.1Output power measurement Test specification: IEC 60705 Load: 1000ml Water/Center Results: Output power : 468W, Input power : 998W Field strength limit @300m : 25μV/m Section 18.305 Temperature, Humidity : 26°C, 72% Tested date: September 19, 2005 Test engineer: S.Hirotani 4.2 Radiation hazard test Test specification: FDA (U.S. Food and Drug Administration) 21CFR 1030.10 Load: 275ml Water/Center Results: Radiation leakge : 0.6W/㎡ max. Temperature, Humidity : 24°C, 75% Tested date: September 19, 2005 Test engineer: S.Hirotani 4.3Frequency measurements Test specification: FCC Part 18 Load: 1000ml Water/Center Results: See Table below Temperature, Humidity : 24°C, 75% Tested date: September 19, 2005 Test engineer: S.Hirotani The variation of frequency with time (Line voltage : 120V/60Hz) Load (ml) Frequency (MHz) The variation of frequency for line voltage (Load : 1000ml Water/Center) Line voltage (V) Frequency (MHz) 24692471247124702471 150 24702471247124732474 96108120132 EMI test report 1000800600400200 Report No. : 05-107 Issued date : September 20, 2005 Page: 3 of 11 4.4Radiated emission measurements Test specification: FCC Part 18 Frequency range: Above 900MHz Field strength limit @300m : 25μV/m, Section 18.305 Result: Pass Tested date: September 19, 2005 Test engineer: S.Hirotani Data of measurement results : Refer to Page 4 4.5Conducted power line measurements Test specification: FCC Part 18 Frequency range: 0.15MHz to 30MHz Conducted limit: Section 18.307 Result: Pass Tested date: September 19, 2005 Test engineer: S.Hirotani Data of test results: Refer to Page 5 5.Description of radiated emission and conducted power line measurements See attached "Description of radiated emission and conducted power line measurements" Page 6. 6.Measuring instruments See attached "List of measuring instruments" Page 7. 7.Physical layout of anechoic chamber and shielded room See attached "Description of radiated emission and conducted power line measurements" Page 8. 8.Environmental condition of test site See attached "Description of radiated emission and conducted power line measurements" Page 9. 9.EUT arrangements See attached "Description of radiated emission and conducted power line measurements" Page 10-11. Report No.: 05-107 Issued date : September 20, 2005 Page: 4 of 11 Manufacturer: Crystal Electric Co., Ltd.Tested date: September 19, 2005 Equipment: Microwave ovenTemperature, Humidity: 24°C, 75% Model No.: MFM-1NTPSTest site: Anechoic chamber Test specification: FCC Part 18Measurement distance: 3m Equipment classification : Consumer ISM equipmentResult: Pass Test procedure: FCC/OST MP-5Test engineer: S.Hirotani Load condition: FCC/OST MP-5 Section 4.1 Line voltage: 120V/60Hz Operation mode: Cooking/600W(Max power) Magnetron: PANASONIC 2M211A-M2J Detector type : Average, IFBW : 1MHzH : Horizontal, V : Vertical 1 2 3 4 5 6 7 8 9 Result @3m (dBμV/m) = Reading(dBμV/m) + Ant. Factor(dB/m) + Cable Loss(dB) - Amp. Gain(dB) Result @300m (μV/m) = Conversion Factor × 10 ^ (Result @3m/20) *Lowest frequency : Lowest frequency generated in the device 700 15.1 700 Center 22.0 700 Center 700 8.92839.5V39.1 Center Center 25.0 Center Radiated emission measurements (Above 900MHz) 3.736.2 0.0100 Ant. polari- zation Ant. Factor (dB/m) H39.1 0.0100 700 1.6 2.0 Radiated emission measurements V21.8 2.836.325.0 11.7 25.0 22.4 25.0 23.0 25.0 Center Center Center (ml) 700 700 Load Position 300 Load Water Center4.425.0 20.6300 Radiated emission measurements 25.0 21.917.54341.4V37.24.833.7 0.0100 3.1 14.80951.9H37.14.733.89.9 4.335.63.0 0.0100 0.010011.87536.3H44.5 9.874H42.53.938.5 7.025H39.13.146.6 25.0 23.4 Limit @300m (μV/m) Margin (μV/m) 23.425.00.0061 0.0065 1.80.0 1.90.0 H21.8 Result @300m (μV/m) Conversion Factor 3m to 300m Cable loss (dB) Amp. Gain (dB) 1.6 13.3 36.6 36.0 0.0100 0.0100 2.6 24.2 56.9 No. Frequency (GHz) Reading (dBμV) 2.38824.6 4.936 2.542 0 10 20 30 40 50 60 70 80 02.454.97.359.812.2514.717.1519.6 Frequency (GHz) Emission level (μV/m) Limit @300m Report No. : 05-107 Issued date : September 20, 2005 Page: 5 of 11 Manufacturer: Crystal Electric Co., Ltd.Tested date: September 20, 2005 Equipment: Microwave ovenTemperature, Humidity : 25°C, 53% Model No.: MFM-1NTPSTest site: Shielded room Test specification: FCC Part 18Result: Pass Equipment classification : Consumer ISM equipmentTest engineer: S.Hirotani Test procedure: FCC/OST MP-5 Load condition: 700ml/Center (FCC/OST MP-5 Section 4.1) Line …

Text truncated - open the document above for the full version.

Test Report

MAGNETRON ENGINEERING & QUALITY ASSURANCE GROUP, ELECTRON TUBES DIVISION 1975, 23-CHOME MINAMI 5-JODORI, ASAHIKAWA, HOKKAIDO 078-8335, JAPAN PHONE : +81-166-31-4728 FACSIMILE : +81-166-31-4739 Mr. R. Kanemitsu Deputy General Manager Research & Development DepartmentReport No. : 05-108 Crystal Electric Co., Ltd.Issued date : September 20, 2005 3-22-5, Higashinakamoto, Higashinari-ku, Osaka 537-0021, Japan Dear R. Kanemitsu, We are enclosing the above mentioned test results based on CISPR11:1990+A2:1996 in our measuring facility. Please feel free to contact us, if you have any question or request. Sincerely yours, Toshiki Azuma Group Manager Magnetron Engineering & Quality Assurance Group Electron Tubes Division AZ/HR cc : Re : EMC test result in your model MFM-1NTPS microwave oven with Panasonic magnetron 2M211A-M2J This report is made only to examine whether the magnetron operates properly as incorporated into the microwave oven that you provided to us, and based upon examinations under limited conditions. This report is not to make any type of warranty on the quality, performance nor safety of any microwave oven manufactured by you. Therefore, you should carry out thorough approval tests before and during manufacturing microwave ovens. In case any claim or problem arises from any defect due to this report, our total liability shall be limited to replacement of the magnetrons in question or refunding the prices allocable to such magnetrons. Report No. : 05-108 Issued date: September 20, 2005 Page: 2 of 6 1.Test laboratory Toshiba Hokuto Electronics Corporation Magnetron Engineering & Quality Assurance Group, Electron Tubes Division Laboratory for EMI measurements 1975-Banchi, 23-Chome, Minami 5-Jodori, Asahikawa 078-8335, Japan Tel : +81-166-31-4728 Fax : +81-166-31-4739 2.Specification of EUT Manufacturer: Crystal Electric Co., Ltd. Equipment: Microwave Oven Model No.: MFM-1NTPS Line voltage: 120V/60Hz Output power: 600W (IEC 60705) Magnetron: PANASONIC 2M211A-M2J 3.Test specification Test specification: CISPR11:1990+A2:1996 Equipment classification : Group 2, Class B 4.Test result 4.1Mains terminal disturbance voltage (Frequency range : 0.15MHz to 30MHz) Test specification: CISPR11:1990+A2:1996 Limit: Table 2b, Group 2, Class B (Clause 5.1.2.1) Frequency range: 0.15MHz to 30MHz Result: Pass Tested date: September 20, 2005 Test engineer: S.Hirotani Data of test results: Refer to Page 4 4.2Electromagnetic radiation disturbance test (Frequency range : 30MHz to 1000MHz) Test specification: CISPR11:1990+A2:1996 Limit: Table 4, Group 2, Class B (Clause 5.2.2) Frequency range: 30MHz to 1000MHz Result: (Pass) See also the note ; Tested date: September 19, 2005 Test engineer: S.Hirotani Data of test results: Refer to Page 5 Note ; This test result is a reference data. at measurement distance 3m. 4.3Electromagnetic radiation disturbance power test (Frequency range : 1GHz to 18GHz) Test specification: CISPR11:1990+A2:1996 Limit: 57dBpW ; 11.7GHz to 12.7GHz, Group 2, Class B (Clause 5.2.3) Frequency range: 1GHz to 18GHz Result: Pass Tested date: September 19, 2005 Test engineer: S.Hirotani Data of test results: Refer to Page 6 Although CISPR11:1990+A2:1996 Table 4 regulations require measurements on the open site at measurement distance 10m, we measured in the anechoic chamber EMI test report Report No. : 05-108 Issued date: September 20, 2005 Page: 3 of 6 5.Measuring instruments Coaxial cable SUCOFLEX100-SF104 Suhner March 2005 (144786/4)(Annually) Coaxial cable SUCOFLEX100-SF104 Suhner March 2005 (134223/4)(Annually) Pre-amplifer 8449B Agilent March 2005 (3008A01826)(Annually) Horn antenna 5C401A SPC Electronics (B176126) Spectrum analyzer 8592L Hewlett Packard March 2005 (3624A00578)(Annually) Coaxial cable SUCOFLEX100-SF104March 2005 (109587/4)(Annually) Bilog antenna CBL6111 Chase (1350) EMI test receiver ESVS30 Rohde & Schwarz March 2005 (827957/010)(Annually) 3D-2W Fujikura March 2005 (Annually) KNW-242 (8-607-6) Kyoritsu Electrical Works March 2005 (Annually) ESHS30 (828144/044) Rohde & Schwarz March 2005 (Annually) Mains terminal disturbance voltage test (0.15MHz to 30MHz) Electromagnetic radiation disturbance test (30MHz to 1000MHz) Electromagnetic radiation disturbance power test (1GHz to 18GHz) EMI test receiver LISN Coaxial cable Calibration date (interval) Test item Manufacturer Model No. (Serial No.) Instruments Report No. : 05-108 Issued date : September 20, 2005 Page: 4 of 6 Manufacturer: Crystal Electric Co., Ltd.Tested date: September 20, 2005 Equipment: Microwave OvenTemperature, Humidity : 25°C, 53% Model No.: MFM-1NTPSTest site: Shielded room Test specification: CISPR11:1990+A2:1996Result: Pass Equipment classification : Group 2, Class BTest engineer: S.Hirotani Frequency range: Table 2b (Clause 5.1.2.1) Load condition: 250ml water (Clause 6.5.4) Line voltage: 120V/60Hz Operation mode: Cooking/600W(Max power) Magnetron: PANASONIC 2M211A-M2J Detector type : Quasi-Peak and Average, IF Bandwidth : 10kHzQP : Quasi-Peak, AV : Average 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Result(dBμV) = Reading(dBμV) + LISN factor(dB) + Cable loss(dB) + Atten.(dB) CISPR 11 Table 2b : Mains terminal disturbance voltage test O : Quasi-Peak, × : Average LISN factor (dB) 29.6 0.131.2 0.114.4 29.9 30.0 24.60.066.0 56.0 56.0 0.1 46.016.00.2 0.15051.7 3.500 51.9 0.1 40.9 0.0 0.0 0.136.6 15.1 5.8 0.1 40.5 15.6 0.2 0.246.0 25.6 14.1 46.0 46.0 19.4 37.2 33.3 56.0 42.4 16.1 39.6 14.5 35.2 17.5 16.4 13.6 7.22.00030.1 6.9 0.130.4 46.0 63.4 53.4 0.150.2 46.0 46.0 41.6 8.8 0.110.8 56.0 56.0 56.0 16.2 0.1 0.55041.4 15.9 0.1 1.00042.2 0.81150.0 No. Mains terminal disturbance voltage test (Frequency range : 0.15MHz to 30MHz) CISPR 11 Table 2b : Mains terminal disturbance voltage test 10.6 0.1 1.80639.4 14.3 0.1 1.33836.4 8.6 0.1 Atten.Frequency Reading (dBμV) (MHz)QP AV Cable loss (dB)(dB) 0.120.145.9 24.8 QPQP Margin (dB) AVAV Result (dBμV) AVQP Limit (dBμV) 10.000 26.8 40.1 32.22.6 0.4 0.6 0.0 27.8 0.7 56.0 46.9 50.…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hideo Tokuyama(Executive Director)
[email protected]81 06 976-1023Fax: 81 06 981-6623

Technical Contact

NISSHIN INDUSTRY CO., LTD. (USA)THOMAS L FARINA
[email protected]847-640-8120

645 DAUPHINE CT · ELK GROVE VILLAGE, Illinois · United States

Non-Technical Contact

NISSHIN INDUSTRY CO., LTD. (USA)THOMAS L FARINA
[email protected]847-640-8120

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.40 GHz - 2.50 GHz600 W

Other Applications from Nisshin Industry Co Ltd

MICROWAVE OVEN-HOUSEHOLD - FCC ID JHU955 - Nisshin Industry Co Ltd
JHU955

MICROWAVE OVEN-HOUSEHOLD

May 01, 2005

Equipment Class

8CC - Part 18 Consumer Device
MICROWAVE OVEN-HOUSEHOLD - FCC ID JHU755 - Nisshin Industry Co Ltd
JHU755

MICROWAVE OVEN-HOUSEHOLD

Dec 20, 2004

Equipment Class

8CC - Part 18 Consumer Device
MICROWAVE OVEN-HOUSEHOLD - FCC ID JHU114 - Nisshin Industry Co Ltd
JHU114

MICROWAVE OVEN-HOUSEHOLD

Aug 10, 2003

Equipment Class

8CC - Part 18 Consumer Device
MICROWAVE OVEN-HOUSEHOLD - FCC ID JHU7558Z - Nisshin Industry Co Ltd
JHU7558Z

MICROWAVE OVEN-HOUSEHOLD

May 02, 2000

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID JHU105ZZ - Nisshin Industry Co Ltd
JHU105ZZ

Microwave Oven

Apr 20, 1999

Equipment Class

8CC - Part 18 Consumer Device