Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! Ǹ! WK636 C-U00075V2.4GHz WM116 1.5V 2.4GHz 100mA N/A N/A 1.5V2.4GHz100mAN/AN/A 100mAN/AN/A 6
Report No. : 141117E15 Page 1 CONSTRUCTION PHOTOS OF EUT Report No. : 141117E15 Page 5
(Fig.1) FCC ID: JNZWM116 FCC LABEL & Label LOCATION The label will be permanently affixed at a conspicuous location on the device.
Report No. : 141117E15 Page 2 Report No. : 141117E15 Page 3 Report No. : 141117E15 Page 4 Report No. : 141117E15 Page 6 Report No. : 141117E15 Page 7
Report No.: RF141117E15 1 of 22 Report Format Version 5.0.0 FCC TEST REPORT REPORT NO.: RF141117E15 MODEL NO.: WM116 FCC ID: JNZWM116 RECEIVED DATE: Nov. 17, 2014 TEST DATE: Nov. 18, 2014 ISSUED DATE: Nov. 25, 2014 APPLICANT: LOGITECH FAR EAST LTD. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF141117E15 2 of 22 Report Format Version 5.0.0 Table of Contents RELEASE CONTROL RECORD ................................................................................. 3 1 CERTIFICATION ............................................................................................... 4 2 SUMMARY OF TEST RESULTS ....................................................................... 5 2.1 MEASUREMENT UNCERTAINTY .................................................................... 5 3 GENERAL INFORMATION ............................................................................... 6 3.1 GENERAL DESCRIPTION OF EUT ................................................................. 6 3.2 DESCRIPTION OF TEST MODES ................................................................... 6 3.3 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................... 7 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ................................... 8 3.5 DESCRIPTION OF SUPPORT UNITS .............................................................. 9 3.6 CONFIGURATION OF SYSTEM UNDER TEST ............................................... 9 4 TEST PROCEDURES AND RESULTS ........................................................... 10 4.1 RADIATED EMISSION AND BAND EDGE MEASUREMENT ........................ 10 4.1.1 LIMITS OF RADIATED EMISSION AND BAND EDGE MEASUREMENT ...... 10 4.1.2 TEST INSTRUMENTS .................................................................................... 11 4.1.3 TEST PROCEDURES ..................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD ........................................................... 12 4.1.5 TEST SETUP .................................................................................................. 13 4.1.6 EUT OPERATING CONDITIONS .................................................................... 14 2.1.1 TEST RESULTS .............................................................................................. 15 5 PHOTOGRAPHS OF THE TEST CONFIGURATION ..................................... 20 6 INFORMATION ON THE TESTING LABORATORIES .................................... 21 7 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ........................................................... 22 Report No.: RF141117E15 3 of 22 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RF141117E15 Original release Nov. 25, 2014 Report No.: RF141117E15 5 of 22 Report Format Version 5.0.0 2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications: APPLIED STANDARD: FCC Part 15, Subpart C (Section 15.249) STANDARD PARAGRAPH TEST TYPE RESULTREMARK 15.207 Conducted Emission Test NA Without AC power port of the EUT. 15.209 15.249 15.249 (d) Radiated Emission Test Band Edge Measurement Limit: 50dB less than the peak value of fundamental frequency or meet radiated emission limit in section 15.209 PASS Meet the requirement of limit. Minimum passing margin is -8.7dB at 901.64MHz 2.1 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Measurement Value Radiated emissions (30MHz-1GHz) 5.37 dB Radiated emissions (1GHz -6GHz) 3.65 dB Radiated emissions (6GHz -18GHz) 3.88 dB Radiated emissions (18GHz -40GHz) 4.11 dB Report No.: RF141117E15 6 of 22 Report Format Version 5.0.0 3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT 2.4GHz Cordless Mouse MODEL NO. WM116 POWER SUPPLY DC 1.5V from battery MODULATION TYPE GFSK CARRIER FREQUENCY OF EACH CH…
Text truncated - open the document above for the full version.
Report No.: 120702E04 1 of 2 PHOTOGRAPHS OF THE TEST CONFIGURATION RADIATED EMISSION TEST (Below 1GHz) Report No.: 120702E04 2 of 2 RADIATED EMISSION TEST (Above 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.47 GHz | - |
Wireless Keyboard
Equipment Class
DTS - Digital Transmission SystemWireless Keyboard
Equipment Class
DTS - Digital Transmission SystemWireless Keyboard
Equipment Class
DTS - Digital Transmission SystemWireless Mouse
Equipment Class
DTS - Digital Transmission SystemWireless Mouse
Equipment Class
DTS - Digital Transmission System