FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lutron Electronics Company Inc/
  3. JPZ0018

JPZ0018Light Dimmer

Lutron Electronics Company Inc
Light Dimmer - FCC ID JPZ0018 - Lutron Electronics Company Inc
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Feb 18, 2002
Application Purpose
Original Equipment
Date of Application
Jan 30, 2002
Equipment Note
Light Dimmer
Frequency Range
418.00000000 - 418.00000000
Company
Lutron Electronics Company Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 1 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 2 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 3 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 4 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 5 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 6 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 7 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 8 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 9 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 10 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 11 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 12 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 13 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 14 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 15 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 16 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 17 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 18 User’s Manual (Installation instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 19 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 20 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 21 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 22 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 23 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 24 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 25 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 26 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 27 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 28 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 29 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 30 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 31 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 32 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 33 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 34 User’s Manual (Programming instructions) RAGRXINS.doc FCC ID: JPZ0018 RA-GRX-3 35

Block Diagram

RAGRXBLK.doc FCC ID: JPZ0018 RA-GRX-3 1 Block Diagram RAGRXBLK.doc FCC ID: JPZ0018 RA-GRX-3 2

Cover Letter(s)

Underwriters Laboratories, Inc. 1285 Walt Whitman Road Melville, NY 11747-3081 Attn: Mr. Don Lerner December 7, 2001 Subject: Request for Confidentiality Dear Don, This letter is to formally request confidentiality per the FCC Rules 47 CFR Chapter 1, subpart C, section 0.459 - requests that materials or information submitted to the Commission be withheld for public inspection. For model RA-GRX-3, the following items are Lutron Electronics Co., Inc. confidential information that must be withheld from public inspection by potential competitors to protect our business. 1. Parts lists 2. Schematics 3. Theory of operation Thank you for your cooperation. Sincerely, R. S. Spehalski Engineering Leader

External Photos

RAGRXEXP.doc FCC ID: JPZ0018 RA-GRX-3 1 External Photos (top view, cover on) External Photos (top view, cover off) RAGRXEXP.doc FCC ID: JPZ0018 RA-GRX-3 2 External Photos (bottom view) External Photos (right side) RAGRXEXP.doc FCC ID: JPZ0018 RA-GRX-3 3 External Photos (left side) RAGRXEXP.doc FCC ID: JPZ0018 RA-GRX-3 4 External Photos (antenna)

ID Label/Location Info

RAGRXLAB2.doc FCC ID: JPZ0018 RA-GRX-3 1 Proposed Unit Label (with JPZ number) Proposed location of unit label (front view) RAGRXLAB2.doc FCC ID: JPZ0018 RA-GRX-3 2 Proposed FCC Warning Label Info RAGRXLAB2.doc FCC ID: JPZ0018 RA-GRX-3 3 FCC Warning Label location (front view) FCC Info Location

Internal Photos

RAGRXINP.doc FCC ID: JPZ0018 RA-GRX-3 1 Internal Photos ( Daughter board bottom side) Internal Photos (Daughter board top side) RAGRXINP.doc FCC ID: JPZ0018 RA-GRX-3 2 Internal Photos (Display board bottom side) Internal Photos (Display board top side) RAGRXINP.doc FCC ID: JPZ0018 RA-GRX-3 3 Internal Photos (Power sub-assembly)

Test Report

Page 1 of 37 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 Underwriters Laboratories Inc. 1285 Walt Whitman Road Melville, New York 11747-3081 (631) 271-6200 Report of Measurements of Electromagnetic Compatibility Testing Test Report File No.:MC2219Date of issue: January 28, 2002 Applicant:Lutron Electronics Co. Inc. Model / Serial No.:RA-GRX-3 / Product Type:Light Dimmer Power Supply:120Vac, 60Hz Manufacturer:Same As Applicant License holder:Same As Applicant Address:7200 Suter Road :Coopersburg, PA 18036 Test Type: Compliance Investigation Manufacturer’s Specification Test Project Number:01ME23499 References(s)FCC ID: JPZ0018 Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP or any agency of the US government. File Number: MC2219Issued: January 28, 2002 Project Number: 01ME23499 Model Number: RA-GRX-3FCC ID: JPZ0018 Page 2 of 37 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 Report Directory 1.0G E N E R A L - Product Description..........................................................................................3 1.1Device Configuration During Test......................................................................................................4 1.2Deviations from ANSI C63.4.............................................................................................................4 1.3Device Modifications Necessary for Compliance.................................................................................5 1.4Test Summary...................................................................................................................................5 2.0EMISSIONS TEST REGULATIONS.........................................................................................6 2.1EUT OPERATION MODE - EMISSIONS TESTS............................................................................6 2.1.1Conducted Emissions Tests.........................................................................................................7 2.1.2Radiated Emissions Test (10 Meter Semi-Anechoic Chamber)....................................................17 2.1.3Fundamental Frequency and Spurious Emissions Measurement Limit Calculations........................34 2.1.4Automatic Cease Operation......................................................................................................35 2.1.5Bandwidth Determination..........................................................................................................36 3.0SUMMARY:.................................................................................................................................37 File Number: MC2219Issued: January 28, 2002 Project Number: 01ME23499 Model Number: RA-GRX-3FCC ID: JPZ0018 Page 3 of 37 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 1.0 G E N E R A L - Product Description Device Function: The RA-GRX-3 is a wall mounted 3-zone dimmer. It contains a super-heterodyne receiver, a saw stabilized transmitter, and an antenna. It is used as part of an integrated lighting control system. The purpose of the RF communication is to transmit and receive command signals. Received command signals allow the RA-GRX-3 to turn zones of light ON or OFF in response to commands from the Lutron RAMC-XX master control keypads and the Lutron RA-REP. Transmitted command signals acknowledge the state of the RA-GRX-3 to the rest of the RadioRA system in response to manual button presses on a master control keypad. RF Function: The receiver down converts a 418.00MHz carrier frequency using a 407.30MHz local oscillator producing a 10.7MHz IF signal. The signal is further processed to decode data. The transmitter uses a SAW oscillator and power amplifier, which is keyed ON/OFF to produce the modulated carrier. The RA-GRX-3 contains a micro controller running at 4MHz to ensure that all transmissions stop within 5 seconds of the button release or within 5 seconds on the beginning of the transmission. A transmission actuated automatically shall cease transmission within 5 seconds after activation. Modulation is AM, specifically ON/OFF Keyed (OOK) or sometimes called Amplitude Shift Keyed (ASK) data at 15.625kbps. The antenna cannot be modified or easily replaced by the user. Analog Function: The RA-GRX-3 obtains power through standard household wiring. The power supply and voltage regulator produce a 5V DC output, which is used to power all analog and micro controller activities. File Number: MC2219Issued: January 28, 2002 Project Number: 01ME23499 Model Number: RA-GRX-3FCC ID: JPZ0018 Page 4 of 37 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 1.1 Device Configuration During Test The device under test was tested in normal orientation that represents the worst case orientation. The device is normally mounted in a vertical wall. The device was tested in two modes o…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emissions test set-up Radiated emissions test 30 – 1000MHz set-up Radiated emissions test 1 – 2GHz set-up Radiated Emissions test 1 – 5GHz set-up

Contact Information

Applicant

Daniel Schlegel(Standards Compliance Supervisor)
[email protected]610-282-6551Fax: 610-282-6354

Technical Contact

Underwriters Laboratories Inc.James R Marley
[email protected](919) 549-1408

12 Laboratory Drive · Research Triangle Park, North Carolina · United States

Non-Technical Contact

Underwriters Laboratories Inc.James R Marley
[email protected](919) 549-1408

Test Firm

UL LLCBob Delisi
[email protected]631-271-6200Fax: 516-439-6095

Technical Specifications

#Rule PartsFrequency RangePower Output
115C418 MHz - 418 MHz-
Confidentiality
Long Term

Other Applications from Lutron Electronics Company Inc

JPZ0161

Wireless Interface

Sep 03, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0159

Wireless Processor

Aug 12, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0158

Copy of Wireless Processor

Jul 27, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0157

LED Downlight

Mar 26, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0155

LED Lighting Controller

Sep 30, 2024

Equipment Class

DTS - Digital Transmission System