FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lutron Electronics Company Inc/
  3. JPZ0020

JPZ0020HRD-5KP

Lutron Electronics Company Inc
HRD-5KP - FCC ID JPZ0020 - Lutron Electronics Company Inc
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Nov 17, 2002
Application Purpose
Original Equipment
Date of Application
Nov 17, 2002
Equipment Note
HRD-5KP
Frequency Range
431.00000000 - 437.00000000
Company
Lutron Electronics Company Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Please Read Before Installing RF Designer-Style Keypads HRD-5KP, -5RL, -10KP, -10RL 120/127VAC, 50/60Hz Installation Instructions Overview The HRD-5KP, -5RL and HRD-10KP, -10RL keypads are for use with HomeWorkssystems. The keypad buttons are programmed with a personal computer using the HomeWorksUtility. Up to 32 keypads, each with a unique address, can be assigned to each HomeWorksRF Processor. HRD-5KP HRD-10KP HRD-10RL HRD-5RL Important Notes Codes:Install in accordance with all local and national electrical codes. Environment:Ambient operating temperature: 0-40°C, 32-104°F, 0-90% humidity, non-condensing. Indoor use only. Wallplates:Lutron Claro ®and Satin ColorsTMwallplates are recommended for best color match and clean aes- thetic appearance. Do not paint controls or wallplates. Cleaning:Clean with a soft damp cloth only.Do not use any chemical or abrasive cleaners. Wallboxes: Lutron recommends using 3.5" (89mm) deep wallboxes for easier installation. RF Device Placement:RF Keypads must be located within 30 feet (9m) of an RF Signal Repeater or an RF Processor. RF Keypads will not function until they are addressed and programmed. See the HomeWorksUtility online help. Mounting Diagram Wallbox Wallplate Adapter* Wallplate* Keypad Mounting Screws Keypad Adapter Mounting Screws 2 * Wallplate and Adapter are purchased separately. 1.Turn power OFF at fusebox or circuit breaker. 2.Prepare wires. When making wire connections, fol- low the recommended strip lengths and combina- tions for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. Small: Strip insulation .375" (10mm) for 14AWG (2.5mm 2 ). Strip insulation .5" (13mm) for 16AWG (2.5mm 2 ). Use to join one 14AWG supply wire with one 16 or 18AWG (1.0mm 2 ) con- trol wire. 3.Wiring: See Wiring Diagram (page 3) 4.Push all wires back into the wallbox and loosely fasten the control to the wallbox using the screws provided. Do not pinch the wires. 5.Attach Lutron Claro®or Satin ColorsTM wallplate adapter and wallplate. a. Loosely install keypad mounting screws. b. Tighten adapter mounting screws snug. c. Tighten keypad mounting screws until keypad is flush to wall (do not over-tighten). d. Snap wallplate onto adapter. 6.Restore power. Included: Wire Connectors (3) Mounting Screws (2) Installation Danger - Locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON may result in personal injury. Small 3 Troubleshooting Guide RF Keypads will not function until they are addressed and programmed. See the HomeWorksUtility online help. Keypad is working properly when LEDs light up and loads respond as buttons are pressed. SymptomCause and Action Power not present at keypad • Circuit breaker OFF. Turn ON breaker. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagram. LEDs don't light up. Wiring Diagram 120/127V 50/60Hz Hot/Live Black Green Earth/Ground Neutral White LEDs cycle from top to bottom sequentially. Keypad is properly powered but... • Keypad has not been addressed. See the HWI Utility online help for addressing details. LEDs light when pressed, but the system response is not correct. Improper programming • Check programming in HWI Utility. Keypad is properly powered but... • Keypad has not been programmed. See the HWI Utility online help for programming details. Keypad is out of RF communications range. • Move RF Repeater or RF Processor to within 30 feet of keypad. LEDs blink twice while cycling from top to bottom sequentially. Keypad cannot be addressed. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 11/02 P/N 043-111 Rev. A LIMITED WARRANTY Lutron will, at its option, repair or replace any unit that is defective in materials or manufac- ture within two years after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. Telephone the Lutron Technical Support Center toll free at 800-523-9466. After the two year period, a pro-rated warranty applies to this product until eight years after the purchase. For more infor- mation regarding this warranty contact your Lutron representative. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO TWO YEARS FROM PUR- CHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR IMPROPER OR INCORRECT REPAIR, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUEN- TIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limi- tation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.This product may be covered by one or more of the following U.S. patents: 4,835,343; 4,889,999; 5,170,068; 5,237,207; D378,814; D436,579 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, and HomeWorks are registered trademarks and Satin Colors is a trademark of Lutron Electronics Co., Inc. © 2002 Lutron Electronics Co., Inc. Technical and Sales Assistance If you need assistance, call the toll-free Lutron Technical Support Center. Please provide exact model number when calling. (800) 523-9466 (U.S.A., Canada and the Caribbean) Other countries call: Tel: (610) 282-3800 Fax: (610) 282-3090 Visit our Web site at www.lutron.com FCC Information Note:This equipment has bee…

Text truncated - open the document above for the full version.

Block Diagram

Page 1 of 1 FCC ID: JPZ0020 HRD-5KP Block Diagram

Cover Letter(s)

Underwriters Laboratories, Inc. 1285 Walt Whitman Road Melville, NY 11747-3081 Attn: Mr. Joe Danisi October 21, 2002 Subject: Request for Confidentiality – HRD-5KP Dear Joe, This letter is to formally request confidentiality per the FCC Rules 47 CFR Chapter 1, subpart C, section 0.459 - requests that materials or information submitted to the Commission be withheld for public inspection. For model HRD-5KP, the Home Serve 5 Button Wall KeypadTransceiver, the following items are Lutron Electronics Co., Inc. confidential information that must be withheld from public inspection by potential competitors to protect our business. 1. Parts lists 2. Schematics 3. Theory of operation Thank you for your cooperation. Sincerely, R. S. Spehalski Engineering Leader

External Photos

1 External Photos (top view) FCC ID: JPZ0020 HRD-5KP 2 External Photos (bottom view) FCC ID: JPZ0020 HRD-5KP 3 External Photos (antenna) FCC ID: JPZ0020 HRD-5KP

ID Label/Location Info

Proposed Unit Label (with JPZ number) FCC ID: JPZ0020 HRD-5KP Proposed location of unit label (left side view) FCC ID: JPZ0020 HRD-5KP Proposed FCC Warning Label FCC ID: JPZ0020 HRD-5KP FCC Warning label location (right side view) JPZ0020 HRD-5KP

Internal Photos

1 Internal Photos (PCB top side) FCC ID: JPZ0020 HRD-5KP 2 Internal Photos (PCB bottom side) FCC ID: JPZ0020 HRD-5KP

Test Report

Underwriters Laboratories Inc. 1285 Walt Whitman Road Melville, New York 11747-3081 (631) 271-6200 Report of Measurements of Electromagnetic Compatibility Testing Test Report File No.: NC2219 Date of issue: 11/5/02 Applicant: Lutron Electronics Co. Inc. Model: HRD-5KP Product Type: Wireless Wall Keypad Power Supply: 120Vac, 60Hz Manufacturer: Same As Applicant License holder: Same As Applicant Address: 7200 Sutron Road Coopersburg, PA 18036 Test Type: ⌧ Compliance Investigation Manufacturer’s Specification Test Project Number: 02ME20017 References(s) FCC ID: JPZ0020 Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP or any agency of the US government. Page 1 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Report Directory 1.0 G E N E R A L - Product Description.........................................................................................3 1.1 Device Configuration During Test...............................................................................................4 1.2 Deviations from ANSI C63.4.......................................................................................................4 1.3 Device Modifications Necessary for Compliance........................................................................5 1.4 Test Summary...............................................................................................................................5 2.0 EMISSIONS TEST REGULATIONS........................................................................................6 2.1 EUT OPERATION MODE - EMISSIONS TESTS.....................................................................6 2.1.1 Conducted Emissions Tests................................................................................................................8 2.1.2 Cease Operation Within 5 Seconds...........................................................................13 2.1.3 Radiated Emissions Test (10 Meter Semi-Anechoic Chamber).......................................................16 2.1.4 Occupied Bandwidth.............................................................................................47 2.1.5 Fundamental Frequency and Spurious Emissions Measurement Limit Calculations ..................50 3 SUMMARY:......................................................................................................................................51 Page 2 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 1.0 G E N E R A L - Product Description Device Function: The HRD-5KP is a wall-mounted keypad. It contains a FM transceiver and an antenna, which is not accessible to the user. It is used as part of an integrated lighting control system. The purpose of the RF communication is to transmit and receive command signals. Transmitted commands allow the triggering of system events. Received commands allow for updating of control indicator status. RF Function: The receiver down converts a 431-437MHz-carrier frequency using a 420.3-426.3MHz voltage-controlled oscillator producing a 10.7MHz IF signal. The signal is further processed to decode data. The transmitter uses the voltage-controlled oscillator, which is frequency modulated, and power amplifier to produce the modulated carrier. The HRD-5KP contains a micro controller running at 32MHz to ensure that all transmissions stop within 5 seconds of a button release or within 5 seconds on the beginning of a transmission. A transmission shall automatically cease within 5 seconds after activation. The ceasing of the transmission is accomplished via the micro controller. Modulation is FM, sometimes referred to as Frequency Shift Keyed (FSK), data at 62.5kbps. The antenna is permanently attached and cannot be modified or replaced by the user since it is underneath the plastic enclosure, which is secured by several odd screws, unit labels that prevent the plastic from being pried open, and plastic snap features. Analog Function: The HRD-5KP obtains power through standard household wiring. The power supply and voltage regulator produces a 5Vdc output, which is used to power all analog and micro controller activities. Page 3 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 1.1 Device Configuration During Test The device under test was tested in normal orientation that represents the worst-case orientation. The device was tested in two modes of operation: 1. Continuously transmitting an intentional radio frequency in Continuous Wave (CW). 2. Standby mode (Receive). The device is waiting to receive a signal source. The manufacturer configured the device. The device was powered with…

Text truncated - open the document above for the full version.

Test Setup Photos

File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Conducted Emission Test Set-Up 0.150 to 30MHz Page 12 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Test Set-Up Cease Operation < 5 seconds Page 15 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Pulse Train Test Set-Up Page 20 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Radiated Emission Test-Set-Up Page 41 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Radiated Emission Test-Set-Up 30-1000MHz Page 42 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Radiated Emission Test-Set-Up 1000-5000MHz Page 43 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Radiated Emission Test-Set-Up 1000-5000MHz Page 44 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Radiated Emission Test-Set-Up 1000-5000MHz Page 45 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/5/02 Project Number: 02ME20017 Model Number: HRD-5KP FCC ID: JPZ0020 Occupied Bandwidth Test Set-Up HRD-5KP Page 49 of 51 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0

Contact Information

Applicant

Daniel Schlegel(Standards Compliance Supervisor)
[email protected]610-282-6551Fax: 610-282-6354

Technical Contact

LUTRON ELECTRONIS INCROBERT BOLLINGER
[email protected]610-282-6509

7200 SUTER ROAD · COOPERSBURG, Pennsylvania · United States

Non-Technical Contact

LUTRON ELECTRONICS INCROBERT SPEHALSKI
[email protected]610-282-7424

Test Firm

UL LLCBob Delisi
[email protected]631-271-6200Fax: 516-439-6095

Technical Specifications

#Rule PartsFrequency RangePower Output
115C431 MHz - 437 MHz-
Confidentiality
Long Term

Other Applications from Lutron Electronics Company Inc

JPZ0161

Wireless Interface

Sep 03, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0159

Wireless Processor

Aug 12, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0158

Copy of Wireless Processor

Jul 27, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0157

LED Downlight

Mar 26, 2026

Equipment Class

DTS - Digital Transmission System
JPZ0155

LED Lighting Controller

Sep 30, 2024

Equipment Class

DTS - Digital Transmission System