Page 1 of 1 FCC ID: JPZ0022 HR-REP Block Diagram
Underwriters Laboratories, Inc. 1285 Walt Whitman Road Melville, NY 11747-3081 Attn: Mr. Joe Danisi October 21, 2002 Subject: Request for Confidentiality – HR-REP Dear Joe, This letter is to formally request confidentiality per the FCC Rules 47 CFR Chapter 1, subpart C, section 0.459 - requests that materials or information submitted to the Commission be withheld for public inspection. For model HR-REP, the Home Serve Signal Repeater, the following items are Lutron Electronics Co., Inc. confidential information that must be withheld from public inspection by potential competitors to protect our business. 1. Parts lists 2. Schematics 3. Theory of operation Thank you for your cooperation. Sincerely, R. S. Spehalski Engineering Leader
Daniel M. Horjus 05/06/2003 10:28 AM To:[email protected] cc:Robert V. Delisi/MEL/ULI@ULI, Joseph Danisi/MEL/ULI@ULI, Ramon J. Torres/CAM/ULI@ULI, William Owsley/CAM/ULI@ULI, Lyn A. Mccann/CAM/ULI@ULI Subject:Re: FCC ID JPZ0022, TC153799, Lutron, Corr Ref # 8054 Dear Katie, You stumped us on this one. Can you please tell us where in the regulations these requirements are found? Can you also please confirm that they really apply to these lighting controls? Following are our responses/questions to your item numbers. 1) Yes this is a "repeater" in that it "retransmits" information that it receives. It's purpose is to transmit and receive command signals in an integrated lighting control system. a) I have been told that it works with 5 different transmitters. Can we put 5 different transmitters on the Grant? It was not tested with each transmitter, it was set to continually transmit during testing. This is the only practical way to test this type of device. The output level is not affected by the information received from the transmitter. b) This is true for this device. c) This requirement is also met because the input (transmission information) does not affect the output level. The output level is the same regardless of the transmitter used to send the command. It is also the same if it specially prepared to transmit continuously as it was for the tests conducted. 2) The equipment classification DSC is for Security Remote Control Transmitter. This is not a security system and it is not just a transmitter, it is a transceiver. We discussed the equipment code when this was submitted and we looked at similar grants and come to the conclusion that it is a low power transceiver, Rx verified, DXT. Can you please explain why SDC is more appropriate? We would be pleased to change it to DSC if this is what it is, but we would like to understand why. 3) It appears that the confidentiality letter did not get uploaded. We will upload it immediately. Best regards, Dan Horjus EMC Engineering Group Leader International EMC Services Underwriters Laboratories, Inc. 2600 N.W. Lake Road Camas, WA 98607 Phone: 360-817-5605 Fax: 360-817-6025 E-mail: [email protected] [email protected] [email protected] c.gov 04/28/03 09:23 PM To:[email protected] cc: Subject: To: Rick Titus From: Katie Hawkins [email protected] FCC Equipment Authorization Branch Re: FCC ID: JPZ0022 Applicant: Lutron Electronics Company Inc Correspondence Reference Number: 8054 731 Confirmation Number: TC153799 Date of Original Email: 04/29/2003 Subject: 1)It appears from the photographs, user manual, and operational description that the device is a repeater. If it is not, please clarify. If it is, note that repeaters are allowed under Section 15.231 of our Rules subject to the following additional requirements: a). A repeater must be tested with a specific transmitter. The FCC identifier of the transmitter will be placed on the grant. b). The repeater only transmits when it demodulates and decodes an incoming signal from the specific transmitter. c). The repeater must meet the output levels in Section 15.231 regardless of the input levels. 2).Please change equipment classification to DSC. 3).Submit a formal confidentiality request letter specifying those exhibits you wish to have held confidential. Your letter must contain a statement of the reason for withholding the materials from inspection and of the facts upon which these records are based. The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal pursuant to Section 2.917(c). DO NOT Reply to this email by using the Reply button. In order for your response to be processed expeditiously, you must upload your response via the Internet at www.fcc.gov, E-Filing, OET TCB Electronic Filing, TCB Login. If the response is submitted through Add Attachments, a message which informs the processing staff that a new exhibit has been submitted must also be submitted via Submit Correspondence. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender.
1 External Photos (top view) FCC ID: JPZ0022 HR-REP 2 External Photos (bottom view) FCC ID: JPZ0022 HR-REP 3 External Photos (antenna) FCC ID: JPZ0022 HR-REP
Proposed Unit Label (with JPZ number) FCC ID: JPZ0022 H-REP Proposed location of unit label (left side view) FCC ID: JPZ0022 H-REP Proposed FCC Warning Label FCC ID: JPZ0022 H-REP
1 Internal Photos (PCB top side) FCC ID: JPZ0022 HR-REP 2 Internal Photos (PCB bottom side) FCC ID: JPZ0022 HR-REP
Underwriters Laboratories Inc. 1285 Walt Whitman Road Melville, New York 11747-3081 (631) 271-6200 Report of Measurements of Electromagnetic Compatibility Testing Test Report File No.: NC2219 Date of issue: 11/5/02 Applicant: Lutron Electronics Co. Inc. Model.: HR-REP Product Type: RF Signal Repeater Power Supply: 120Vac, 60Hz Manufacturer: Same As Applicant License holder: Same As Applicant Address: 7200 Sutron Road Coopersburg, PA 18036 Test Type: ⌧ Compliance Investigation Manufacturer’s Specification Test Project Number: 02ME20017 References(s) FCC ID: JPZ0022 Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP or any agency of the US government. Page 1 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Report Directory 1.0 G E N E R A L - Product Description.........................................................................................3 1.1 Device Configuration During Test:..............................................................................................4 1.2 Deviations from ANSI C63.4.......................................................................................................4 1.3 Device Modifications Necessary for Compliance........................................................................5 1.4 Test Summary...............................................................................................................................5 2.0 EMISSIONS TEST REGULATIONS........................................................................................6 2.1 EUT OPERATION MODE - EMISSIONS TESTS.....................................................................6 2.1.1 Conducted Emissions Tests................................................................................................................8 2.1.2 Cease Operation Within 5 Seconds...........................................................................13 2.1.3 Radiated Emissions Test (10 Meter Semi-Anechoic Chamber).......................................................16 2.1.4 Occupied Bandwidth.............................................................................................45 2.1.5 Fundamental Frequency and Spurious Emissions Measurement Limit Calculations...................49 3.0 SUMMARY:...............................................................................................................................50 Page 2 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 1.0 G E N E R A L - Product Description Device Function: The HR-REP acts as a signal repeater in an integrated lighting control system. It contains an FM transceiver and an antenna. The purpose of a RF communication is to transmit and receive command signals. Transmitted commands allow the triggering of system events and the updating of control indicator status. RF Function: The receiver down converts a 431-437MHz-carrier frequency using a 420.3-426.3MHz voltage-controlled oscillator producing a 10.7MHz IF signal. The signal is further processed to decode data. The transmitter uses the voltage-controlled oscillator, which is frequency modulated, and power amplifier to produce the modulated carrier. The HR-REP contains a micro controller running at 32MHz to ensure that all transmissions stop within 5 seconds of a button release or within 5 seconds on the beginning of a transmission. A transmission shall automatically cease within 5 seconds after activation. Modulation is FM, sometimes referred to as Frequency Shift Keyed (FSK), data at 62.5kbps. The antenna cannot be modified or easily replaced by the user. Analog Function: The HR-REP obtains power through a 120Vac to 9Vdc Class 2 transformer. The voltage is then linearly regulated down to a 5Vdc output, which is used to power all analog and micro controller activities. Page 3 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 1.1 Device Configuration During Test: The device under test was tested in normal orientation that represents the worst-case orientation. The device was tested in two modes of operation: 1. Continuously transmitting an intentional radio frequency in Continuous Wave (CW). 2. Standby mode (Receive). The device is waiting to receive a signal source. The manufacturer configured the device. The device was powered with 120VAC, 60Hz. Device Manufacturer Model Number Serial Number FCC ID RF Signal Repeater Lutron HR-REP N/A JPZ0022 Class 2 Power Supply Lutron 280903003CO N/A ------------------ "The results contained in this report reflect the results for this particular model and serial number. It is the responsibility of the manufacturer to ensure that all pro…
Text truncated - open the document above for the full version.
File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Conducted Emissions Test Set-Up 150k-30MHz Page 12 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Test Set-Up Cease Operation < 5 seconds Page 15 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Pulse Train Test Set-Up Page 20 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Pulse Train Test Set-Up Page 41 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Radiated Emission Test Set-Up 30-1000MHz Front View Page 42 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Radiated Emission Test Set-Up 30-1000MHz Rear View Page 43 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Radiated Emission Test Set-Up 1-5GHz Front View Page 44 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Occupied Bandwidth Test Set-up HR-REP Page 48 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0
7200 SUTER ROAD · COOPERSBURG, Pennsylvania · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 431 MHz - 437 MHz | - |
Wireless Interface
Equipment Class
DTS - Digital Transmission SystemWireless Processor
Equipment Class
DTS - Digital Transmission SystemCopy of Wireless Processor
Equipment Class
DTS - Digital Transmission SystemLED Downlight
Equipment Class
DTS - Digital Transmission SystemLED Lighting Controller
Equipment Class
DTS - Digital Transmission System