Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Codes:Install in accordance with all local and national electrical codes. Environment:Ambient operating temperature: 0-40°C, 32-104°F, 0-90% humidity, non-condensing. Indoor use only. Cleaning:Clean with a soft damp cloth only.Do not use any chemical or abrasive cleaners. RF Device Placement:RF Signal Repeaters must be located within 60 feet (18m) of an RF Processor or another RF Signal Repeater. Power:Use only the DC adapter provided by Lutron with your unit (Lutron model # T120-9DC-3-WH). Caution -Using a DC adapter not rated at the following specifications could damage the con- trol and possibly overheat the DC adapter. • Input: AC 120/127V 50/60Hz • Output: DC 9V/300mA Class 2 Please Read Before Installing Installation Instructions Overview The HomeWorksRF Signal Repeater provides additional coverage area for Radio Frequency (RF) signals sent between HomeWorksRF Dimmers/Switches, and RF Keypads. Each RF Signal Repeater covers approximately 2500 square feet (232m 2 ) of living space. RF Signal Repeater HR-REP-SW 120/127VAC, 50/60Hz (DC Adapter) AUXILI ARY ACTIVATE TEST HR-REP-SW 2 DC Adapter Installation 1.Find a suitable location for the RF Signal Repeater.Place the Repeater in a convenient and accessible location. Note:RF Signal Repeaters should be located within 60 feet (18m) of another RF Signal Repeater or an RF Processor. 2.Apply power to the RF Signal Repeater. Optional Wall Mounting RF Signal Repeaters may be wall mounted using the supplied wall bracket. Verify Auxiliary LED is lit when powered Plug in power cord and DC adapter Attach wall bracket to wall using the supplied screws and wall anchors. Wrap excess DC Adapter cord around the cord holder. Align Repeater and snap onto wall bracket. UP UP AUXILIARYACTIVATETEST Function LEDs Test Button Tests whether RF components can “hear” RF Signal Repeater, and if RF Signal Repeater can “hear” RF compo- nents. Activate Button Used when adding RF Signal Repeater to the system. Auxiliary Button LED indicates RF Signal Repeater is powered (button is not used). Operation System Communications 3 ## P/N 292-153P/N 292 153 Notes • RF Dimmers and Keypads must be locat- ed within 30 feet (9m) of an RF Signal Repeater or an RF Processor. Multiple repeaters may be necessary to provide adequate coverage. • RF Dimmers cannot be controlled by the system and RF Keypads do not function until they are addressed and programmed. See the HomeWorksUtility online help. RF Tabletop Keypad RF Dimmer 30 Feet (9m) maximum RF Processor RF Keypad Home A: 2500 sq. ft. (232m 2 ) or less - all RF devices within 30' (9m) of RF Processor ## P/N 292-153P/N 292 153 RF Tabletop Keypad RF Dimmer 30 Feet (9m) maximum RF Processor RF Keypad Home B: 2500 sq. ft. (232m 2 ) or greater - some RF devices more than 30' (9m) from RF Processor RF Signal Repeater 30 Feet (9m) maximum 60 Feet (18m) maximum between RF Processors and Repeaters, or between Repeaters LIMITED WARRANTY Lutron will, at its option, repair or replace any unit that is defective in materials or manufac- ture within two years after purchase. After the two year period, a pro-rated warranty applies to this product until eight years after the purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre- paid. Telephone the Lutron Technical Support Center toll free at 800-523-9466. For more information regarding this warranty contact your Lutron representative. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO TWO YEARS FROM PUR- CHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR IMPROPER OR INCORRECT REPAIR, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUEN- TIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limi- tation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.This product may be covered by one or more of the following U.S. patents: 4,835,343; 5,736,965; 5,838,226; 5,848,054; 5,905,442; 5,982,103; DES 389,805; DES 404,013 and corresponding foreign patents. U.S. and foreign patents pending. Lutron and HomeWorks are registered trademarks of Lutron Electronics Co., Inc. © 2002 Lutron Electronics Co., Inc. Technical and Sales Assistance If you need assistance, call the toll-free Lutron Technical Support Center. Please provide exact model number when calling. (800) 523-9466 (U.S.A., Canada and the Caribbean) Other countries call: Tel: (610) 282-3800 Fax: (610) 282-3090 Visit our Web site at www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 11/02 P/N 043-110 Rev. A HomeWorks®Interactive RF Signal Repeater Troubleshooting SymptomCause and Action No power available to unit. • Faulty power supply. Replace power supply. Repeater not programmed. • Refer to the HomeWorksUtility online help for program- ming instructions. Repeater appears not to be working. FCC Information Note:This equipment has been tested and found to comply with the limits for a Class B digi- tal device, pursuant to Part 15 of the FCC rules. These limits are designed to provide rea- sonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed in accordance with the instructions, may cause harmful interference to radio…
Text truncated - open the document above for the full version.
1 External Photos (top view) FCC ID: JPZ0022 HR-REP 2 External Photos (bottom view) FCC ID: JPZ0022 HR-REP 3 External Photos (antenna) FCC ID: JPZ0022 HR-REP
Proposed Unit Label (with JPZ number) FCC ID: JPZ0022 H-REP Proposed location of unit label (left side view) FCC ID: JPZ0022 H-REP Proposed FCC Warning Label FCC ID: JPZ0022 H-REP
Proposed Unit Label (with JPZ number) FCC ID: JPZ0022 H-REP Proposed location of unit label (left side view) FCC ID: JPZ0022 H-REP Proposed FCC Warning Label FCC ID: JPZ0022 H-REP
1 Internal Photos (PCB top side) FCC ID: JPZ0022 HR-REP 2 Internal Photos (PCB bottom side) FCC ID: JPZ0022 HR-REP
Underwriters Laboratories Inc. 1285 Walt Whitman Road Melville, New York 11747-3081 (631) 271-6200 Report of Measurements of Electromagnetic Compatibility Testing Test Report File No.: NC2219 Date of issue: 11/5/02 Applicant: Lutron Electronics Co. Inc. Model.: HR-REP Product Type: RF Signal Repeater Power Supply: 120Vac, 60Hz Manufacturer: Same As Applicant License holder: Same As Applicant Address: 7200 Sutron Road Coopersburg, PA 18036 Test Type: ⌧ Compliance Investigation Manufacturer’s Specification Test Project Number: 02ME20017 References(s) FCC ID: JPZ0022 Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP or any agency of the US government. Page 1 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Report Directory 1.0 G E N E R A L - Product Description.........................................................................................3 1.1 Device Configuration During Test:..............................................................................................4 1.2 Deviations from ANSI C63.4.......................................................................................................4 1.3 Device Modifications Necessary for Compliance........................................................................5 1.4 Test Summary...............................................................................................................................5 2.0 EMISSIONS TEST REGULATIONS........................................................................................6 2.1 EUT OPERATION MODE - EMISSIONS TESTS.....................................................................6 2.1.1 Conducted Emissions Tests................................................................................................................8 2.1.2 Cease Operation Within 5 Seconds...........................................................................13 2.1.3 Radiated Emissions Test (10 Meter Semi-Anechoic Chamber).......................................................16 2.1.4 Occupied Bandwidth.............................................................................................45 2.1.5 Fundamental Frequency and Spurious Emissions Measurement Limit Calculations...................49 3.0 SUMMARY:...............................................................................................................................50 Page 2 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 1.0 G E N E R A L - Product Description Device Function: The HR-REP acts as a signal repeater in an integrated lighting control system. It contains an FM transceiver and an antenna. The purpose of a RF communication is to transmit and receive command signals. Transmitted commands allow the triggering of system events and the updating of control indicator status. RF Function: The receiver down converts a 431-437MHz-carrier frequency using a 420.3-426.3MHz voltage-controlled oscillator producing a 10.7MHz IF signal. The signal is further processed to decode data. The transmitter uses the voltage-controlled oscillator, which is frequency modulated, and power amplifier to produce the modulated carrier. The HR-REP contains a micro controller running at 32MHz to ensure that all transmissions stop within 5 seconds of a button release or within 5 seconds on the beginning of a transmission. A transmission shall automatically cease within 5 seconds after activation. Modulation is FM, sometimes referred to as Frequency Shift Keyed (FSK), data at 62.5kbps. The antenna cannot be modified or easily replaced by the user. Analog Function: The HR-REP obtains power through a 120Vac to 9Vdc Class 2 transformer. The voltage is then linearly regulated down to a 5Vdc output, which is used to power all analog and micro controller activities. Page 3 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 1.1 Device Configuration During Test: The device under test was tested in normal orientation that represents the worst-case orientation. The device was tested in two modes of operation: 1. Continuously transmitting an intentional radio frequency in Continuous Wave (CW). 2. Standby mode (Receive). The device is waiting to receive a signal source. The manufacturer configured the device. The device was powered with 120VAC, 60Hz. Device Manufacturer Model Number Serial Number FCC ID RF Signal Repeater Lutron HR-REP N/A JPZ0022 Class 2 Power Supply Lutron 280903003CO N/A ------------------ "The results contained in this report reflect the results for this particular model and serial number. It is the responsibility of the manufacturer to ensure that all pro…
Text truncated - open the document above for the full version.
File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Conducted Emissions Test Set-Up 150k-30MHz Page 12 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Test Set-Up Cease Operation < 5 seconds Page 15 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Pulse Train Test Set-Up Page 20 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Pulse Train Test Set-Up Page 41 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Radiated Emission Test Set-Up 30-1000MHz Front View Page 42 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Radiated Emission Test Set-Up 30-1000MHz Rear View Page 43 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Radiated Emission Test Set-Up 1-5GHz Front View Page 44 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0 File Number: NC2219 Issued: 11/6/02 Project Number: 02ME20017 Model Number: HR-REP FCC ID: JPZ0022 Occupied Bandwidth Test Set-up HR-REP Page 48 of 50 Underwriters Laboratories Inc. 1285 Walt Whitman Rd. Melville, New York 11747 USA Tel.: 631 271-6200 Fax: 631 439-6095 Rev. No 1.0
7200 SUTER ROAD · COOPERSBURG, Pennsylvania · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 431 MHz - 437 MHz | - |
Wireless Interface
Equipment Class
DTS - Digital Transmission SystemWireless Processor
Equipment Class
DTS - Digital Transmission SystemCopy of Wireless Processor
Equipment Class
DTS - Digital Transmission SystemLED Downlight
Equipment Class
DTS - Digital Transmission SystemLED Lighting Controller
Equipment Class
DTS - Digital Transmission System