FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Belkin International, Inc./
  3. K7SBPD008

K7SBPD008BoostCharge Pro Magnetic Power Bank 10K

Belkin International, Inc.

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 02, 2024
Application Purpose
Original Equipment
Date of Application
Apr 02, 2024
Equipment Note
BoostCharge Pro Magnetic Power Bank 10K
Frequency Range
0.36000000 - 0.36000000
Company
Belkin International, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Fe deral Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name K7SBPD008 BPD008 We, applicant Company Name: Belkin International, Inc. Address: 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Phone: +1 310 633 9309*2960 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date Daisy Dai 2024-4-1 Printed Name of Signee: Company: Belkin International, Inc. Address: 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA P hone: +1 310 633 9309*2960 Fax:N/A Email: [email protected]

Attestation Statements

Rev 1/26/2023 Belkin International, Inc. Fe deral Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 01, 2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID or Grantee Code: [K7SBPD008] Applicant FRN: [0008128605] [Belkin International, Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, [B elkin International, Inc.] is our designated U.S. agent for service of process for the above referenced FCC ID. [Belkin International, Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. [Belkin International, Inc.] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: [Belkin International, Inc.] U. S. Agent FRN: [0008128605] Address: [555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA] Contact Person: [Jay Tu] Tel.: [310-633-9309(ext: 9142)] Em ail: [[email protected]] Sincerely, Belkin International, Inc. Belkin International, Inc. Daisy Dai Daisy Dai

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Fe deral Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name K7SBPD008 BPD008 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date Daisy Dai 2024-4-1 Printed Name of Signee: Company: Belkin International, Inc. A ddress: 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Phone: +1 310 633 9309*2960 Fax: Email: [email protected]

Cover Letter(s)

Belkin International, Inc. 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA 2024/4/1 To: Federal Communicaons Commission 7435 Oakland Mills Road Columbia, MD FCC ID: K7SBPD008 To Whom It May Concern: This le'er is to ascertain that ( Belkin International, Inc.) Product (BoostCharge Pro Magnetic Power Bank 10K ) Wireless Charger (BPD008), has been the units used for conducng FCC compliance tesng, and it meets KDB 680106 D01 V04 Clause 5(2) all 6 condions except criteria (4). Criteria Requirements Yes No Explanaon (1) The power transfer frequency is below 1 MHz. The power transfer frequency are 127.7kHz/360.0kHz (2) The output power from each transmi<ng element (e.g., coil) is less than or equal to 15 wa's. The maximum output power of each coil is less than 15 wa's. (3) A client device providing the maximum permi'ed load is placed in physical contact with the transmi'er (i.e., the surfaces of the transmi'er and client device enclosures need to be in physical contact) (4) Only § 2.1091-Mobile exposure condions apply Portable exposure condions (5) The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% of the applicable MPE limit, per KDB 447498, Table 1. These measurements shall be taken along the principal axes of the device, with one axis oriented along the direcon of the esmated maximum field strength, and for three points per axis or unl a 1/d (inverse distance from the emi'er structure) field strength decay is observed. Symmetry consideraons may be used for test reducon purposes. The device shall be operated in documented worst-case compliance scenarios (i.e., the ones that lead to the maximum field components), and while all the radiang structures (e.g., coils or antennas) that by design can simultaneously transmit are energized at their nominal maximum power. See the test report. (6) For systems with more than one radiang structure, the condions specified in (5) must be met when the system is fully loaded (i.e., clients absorbing maximum power available), and with all the radiang structures operang at maximum power at the same me, as per design condions. The DUT(Device Under Test) includes only one radiang structure, and operang at maximum power Belkin International, Inc. 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA If the design allows one or more radiang structures to be powered at a higher level while other radiang structures are not powered, then those cases must be tested as well. For instance, a device may use three RF coils powered at 5 W, or one coil powered at 15 W: in this case, both scenarios shall be tested. If you have any queson or concerns, please contact us. Sincerely Yours, Name / Title: Daisy Dai/ Regulatory Compliance Engineer C ompany Name: Belkin International, Inc. Company Address: 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA T el: +1 310 633 9309*2960 Fax: N/A Email: [email protected]

Cover Letter(s)

Power of Attorney Date: Jan. 10, 2022 To whom it may concern: I, the undersigned, Jay Tu, hereby authorize the person listed below to act in behalf of me to sign all related documents for Belkin International, Inc.’s FCC/IC application. Name: Zack Vogel / Regulatory Compliance Engineer, Regulatory Compliance Tel: +1 800-223-5546 E-mail: [email protected] Name: Andrei Moldavanov / Regulatory Compliance Engineer, Regulatory Compliance E-mail: [email protected] Name: Rossi Wu / Senior Regulatory Compliance Engineer, Regulatory Compliance Tel: +1 310 633 9309 # 2960 E-mail: [email protected] Name: Daisy Dai / Regulatory Compliance Engineer, Regulatory Compliance Tel: O +86 755 2387 1039 E-mail: [email protected] Respectfully, Applicant’s company name: Belkin International, Inc. Applicant’s company address: 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245-4852, USA Signature Name and Job Title: Jay Tu / Manager, Regulatory Compliance

Cover Letter(s)

Short Term Confidentiality Request Letter For Certification Service in the USA F ederal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705) , we request short term confidentiality prior to marketing the device for the documentation of the following products: FCC ID Model name K7SBPD008 BPD008 For the products listed above, we request short term confidentiality for all applicable exhibits as there are: • Internal photos • External Photos • Test Photos • User manual The above listed exhibits contain business sensitive information which we wish to keep confidential until the actual marketing of our device, that is planned for: Short term confidentiality release date: <date – max 180 after issue of grant> I f you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date Daisy Dai 2024-4-1 Printed Name of Signee: Company: Belkin International, Inc. Address: 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Phone: +1 310 633 9309*2960 Fax: N/A Email: [email protected]

ID Label/Location Info

Model: BPD008Model: BPD008Model: BPD008

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 16 Report Version 1 Test Report No.: FM2403WDG0230 RF EXPOSURE TEST REPORT Applicant Belkin International, Inc. Address 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Manufacturer or Supplier Belkin International, Inc. Address 555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Product BoostCharge Pro Magnetic Power Bank 10K Brand Name belkin Model BPD008 Additional Model & Model Difference N/A Date of tests Mar. 25, 2024 ~ Mar. 28, 2024 The submitted sample of the above equipment has been tested according to the requirements of the following standard: 47 CFR PART 1, Subpart I, Section 1.1310 KDB 680106 D01 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Eric Fang Project Engineer / EMC Department Approved by Glyn He Assistant Manager/ EMC Department Data: Apr. 02, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 16 Report Version 1 Test Report No.: FM2403WDG0230 TABLE OF CONTENTS RF EXPOSURE TEST REPORT ................................................................................................................1 RELEASE CONTROL RECORD ..................................................................................................................3 1. GENERAL INFORMATION ..................................................................................................................4 1.1. GENERAL DESCRIPTION OF EUT ............................................................................................4 2. RF EXPOSURE MEASUREMENT ......................................................................................................5 2.1 LIMITS .........................................................................................................................................5 2.2 DESCRIPTION OF SUPPORT UNITS ........................................................................................5 2.3 CONFIGURATION OF SYSTEM UNDER TEST .........................................................................6 2.4 TEST SETUP FOR WPC .............................................................................................................6 2.5 EQUIPMENTS USED DURING TEST.........................................................................................7 2.6 TEST POINT DESCRIPTION ......................................................................................................7 2.7 TEST RESULTS ..........................................................................................................................8 3. PHOTOGRAPHS OF THE TEST CONFIGURATION....................................................................... 16 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 16 Report Version 1 Test Report No.: FM2403WDG0230 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2403WDG0230 Original release Apr. 02, 2024 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 16 Report Version 1 Test Report No.: FM2403WDG0230 1. GENERAL INFORMATION 1.1. GENERAL DESCRIPTION OF EUT FCC ID K7SBPD008 PRODUCT BoostCharge Pro Magnetic Power Bank 10K MODEL NO. BPD008 ADDITIONAL MODEL N/A POWER SUPPLY 5Vdc or 9 Vdc (adapter) MODULATION TECHNOLOGY FSK OPERATING FREQUENCY RANGE 127.7kHz( for iPhone 15 Pro >80% Battery Charging) 360.0kHz( for iPhone 15 Pro <80% Battery Charging) MAXIMUM POWER OUTPUT FOR Q2 CHARGING COIL 15W ANTENNA TYPE Coil Antenna I/O PORTS Refer to user’s manual CABLE SUPPLIED USB-…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jay TU(Manager, Regulatory Compliance)
[email protected]310-633-9309Fax: none

Technical Contact

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchJoyce Fang
[email protected]+86-769-85935656

No.96, Guantai Road (Houjie Section) · Dongguan · China

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-260-0884Fax: +886-3-211-5834

Technical Specifications

#Rule PartsFrequency RangePower Output
215C0.36 MHz - 0.36 MHz-
Confidentiality
Long Term

Other Applications from Belkin International, Inc.

K7S-CAB029

SureFind Loop Cable Tag

Aug 11, 2026

Equipment Class

DTS - Digital Transmission System
K7SBPD024

UltraCharge Pro Slim Magnetic Power Bank 5K with BoostSolid Cell

Aug 10, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
K7SMMA016

SureFind Wallet Stand

Jul 22, 2026

Equipment Class

DTS - Digital Transmission System
K7SMMA015

SureFind

Jul 10, 2026

Equipment Class

DTS - Digital Transmission System
K7SAUC018

SoundForm Dot ANC Earbuds, SoundForm Dot Earbuds

Jun 17, 2026

Equipment Class

DTS - Digital Transmission System