Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date: 2024-06-17 FCC ID: K7SWIA008V2 To the attention of Federal Communications Commission Authorization and Evaluation Division Attestation Statements Attestation Statements Part 2.911(d)(5)(i) Filing Belkin International, Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receivingan equipment authorization pursuant to section 2.903 of the FCC rules. Attestation Statements Part 2.911(d)(5)(ii) Filing Belkin International, Inc.certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely yours, ----------------------------------------------- Zack Vogel, Sr. Regulatory Compliance Engineer Belkin International, Inc. Tel: +1 310 751 2800 E- mail: [email protected]
U.S. Agent for Service of Process Attestation To the attention of Federal Communications Commission Authorization and Evaluation Division Applicant / Designated U.S Agent Company Name: Belkin International, Inc. FRN: 0008128605 Grantee code: K7S Contact Name: Jay Tu Address: 555 S Aviation Blvd. Suite 180 El Segundo, CA 90245 USA Telephone No: +1 310 633 9309 # 9142 Email: [email protected] This letter is to confirm that the Applicant has designated itself as the U.S Agent for service of process as required by §2.911(d)(7). The Applicant further acknowledges acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant / U.S. Agent Signature: Date: 2023-12-28 Signed by (printed name): Zack Vogel
Date: 2024-06 -17 FCC ID: K7SWIA008V2 To the attention of Federal Communications Commission Authorization and Evaluation Division Permanent Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ----------------------------------------------- Zack Vogel, Sr. Regulatory Compliance Engineer Belkin International, Inc. Tel: +1 310 751 2800 E- mail: [email protected]
Date: 2024-06-17 FCC ID: K7SWIA008V2 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until (180 days after the Grant Date of Equipment Authorization) in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ----------------------------------------------- Zack Vogel, Sr. Regulatory Compliance Engineer Belkin International, Inc. Tel: +1 310 751 2800 E- mail: [email protected]
Date: 2024-06-17 FCC ID: K7SWIA008V2 AUTHORIZATION LETTER To Whom It May Concern: Belkin International, Inc. hereby authorizes Tilly Pan / Specialist of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (“BV CPS Taoyuan”), to act on its behalf in all matters relating to the Federal Communication Commission (“FCC”) application for equipment authorization in connection with the FCC ID listed above, including signing of all documents relating to these matters. Any and all acts carried out by Tilly Pan / Specialist of BV CPS Taoyuan on Belkin International, Inc.’s behalf, within the scope of the powers granted herein, shall have the same effect as acts of its own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ----------------------------------------------- Zack Vogel, Sr. Regulatory Compliance Engineer Belkin International, Inc. Tel: +1 310 751 2800 E- mail: [email protected]
Power of Attorney Date: June 19, 2024 To whom it may concern: I, the undersigned, Jay Tu, hereby authorize the person(s) listed below to act on behalf of me to sign all related documents for Belkin International, Inc.’s FCC/IC application. Name: Zack Vogel / Sr. Regulatory Compliance Engineer, Regulatory Compliance Tel: +1 310 751 2800 E-mail: [email protected] Name: Rossi Wu / Senior Regulatory Compliance Engineer, Regulatory Compliance Tel: +1 310 633 9309 # 2960 E-mail: [email protected] Name: Daisy Dai / Regulatory Compliance Engineer, Regulatory Compliance Tel: O +86 755 2387 1039 E-mail: [email protected] Respectfully, Applicant’s company name: Belkin International, Inc. Applicant’s company address: 555 S. Aviation Blvd., Suite 180, EI Segundo, CA 90245, USA Signature Name and Job Title: Jay Tu / Manager, Regulatory Compliance E-mail: [email protected] Tel: +1 310 633 9309 # 9142
Report No.: MFBCBS-WTW-P24050227 Page No. 1/ 14Report Format Version: 6.1.1 RF Exposure Report Report No.:MFBCBS-WTW-P24050227 FCC ID:K7SWIA008V2 Test Model:WIA008V2 Received Date:May 09, 2024 Test Date:Jun. 06, 2024 Issued Date:Jun. 27, 2024 Applicant:Belkin International, Inc. Address:555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Issued By:Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address:No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location:No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN FCC Registration / Desi gnation Number: 788550 / TW0003 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBCBS-WTW-P24050227 Page No. 2/ 14Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 General Information .............................................................................................................................. 5 2.1 General Description of EUT ................................................................................................................ 5 2.2 Description of Test Modes ................................................................................................................... 6 3 RF Exposure .......................................................................................................................................... 7 3.1 Description of Support Units ............................................................................................................... 7 3.1.1 Configuration of System under Test .................................................................................................... 7 3.2 Test Setup ........................................................................................................................................... 8 3.3 Test Instruments .................................................................................................................................. 8 3.4 Limits for Maximum Permissible Exposure (MPE) .............................................................................. 9 3.5 Test Point Description ....................................................................................................................... 10 4. Calculation Result of Maximum Conducted Power .......................................................................... 11 5. Photographs of the Test Configuration ............................................................................................ 14 Report No.: MFBCBS-WTW-P24050227 Page No. 3/ 14Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued MFBCBS-WTW-P24050227 Original release Jun. 27, 2024 Report No.: MFBCBS-WTW-P24050227 Page No. 4 / 14Report Format Version: 6.1.1 1 Certificate of Conformity Product: BoostCharge Pro Convertible Magnetic Charging Stand Brand: belkin Test Model: WIA008V2 Sample Status: Engineering sample Applicant: Belkin International, Inc. Test Date: Jun. 06, 2024 FCC Rule Part: FCC Part 1 (Section 1.1307(b), Section 1.1310) FCC Part 2 (Section 2.1091) Standards: KDB 680106 D01 Wireless Power Transfer v04 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Prepared by : , Date:Jun. 27, 2024 Polly Chien / Specialist Approved by : , Date:Jun. 27, 2024 Jeremy Lin / Project Engineer Report No.: MFBCBS-WTW-P24050227 Page No. 5 / 14Report Format Version: 6.1.1 2 General Information 2.1 General Description of EUT Product BoostCharge Pro Convertible Magnetic Charging Stand Brand belkin Test Model WIA008V2 Sample Status Engineering sample Power Supply Rating 5 or 9 or 12 Vdc(adapter) Modulation Type FSK Operating Frequency 127.7kHz for iPhone (8-11 series) 360.0kHz for iPhone (12 ser…
Text truncated - open the document above for the full version.
Report No.: RFBCBS-WTW-P24050227 Page No. 1/ 41Report Format Version: 6.1.1 FCC Test Report Report No.:RFBCBS-WTW-P24050227 FCC ID:K7SWIA008V2 Test Model:WIA008V2 Received Date:May 09, 2024 Test Date:May 27, 2024 ~ May 30, 2024 Issued Date:Jun. 27, 2024 Applicant:Belkin International, Inc. Address:555 S. Aviation Blvd., Suite 180, El Segundo, CA 90245, USA Issued By:Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address:No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location:No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN FCC Registration / Desi gnation Number: 788550 / TW0003 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: RFBCBS-WTW-P24050227 Page No. 2/ 41Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 Summary of Test Results ..................................................................................................................... 5 2.1 Measurement Uncertainty ................................................................................................................... 5 2.2 Modification Record ............................................................................................................................ 5 3 General Information .............................................................................................................................. 6 3.1 General Description of EUT ................................................................................................................ 6 3.2 Description of Test Modes ................................................................................................................... 7 3.2.1 Test Mode Applicability and Tested Channel Detail ............................................................................. 8 3.3 Description of Support Units ............................................................................................................... 9 3.3.1 Configuration of System under Test .................................................................................................... 9 3.4 General Description of Applied Standards .......................................................................................... 9 4 Test Types and Results ...................................................................................................................... 10 4.1 Radiated Emission and Bandedge Measurement ............................................................................. 10 4.1.1 Limits of Radiated Emission and Bandedge Measurement .............................................................. 10 4.1.2 Test Instruments ................................................................................................................................. 11 4.1.3 Test Procedures ................................................................................................................................. 12 4.1.4 Deviation from Test Standard ............................................................................................................ 12 4.1.5 Test Set Up ........................................................................................................................................ 13 4.1.6 EUT Operating Conditions ................................................................................................................. 13 4.1.7 Test Results ....................................................................................................................................... 14 4.2 Conducted Emission Measurement .................................................................................................. 29 4.2.1 Limits of Conducted Emission Measurement .................................................................................... 29 4.2.2 Test Instruments ................................................................................................................................ 29 4.2.3 Test Procedures ........................................................................…
Text truncated - open the document above for the full version.
No.19, Hwa Ya 2nd Rd., Wen Hwa Vil. · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 0.36 MHz - 0.36 MHz | - |
SureFind Loop Cable Tag
Equipment Class
DTS - Digital Transmission SystemUltraCharge Pro Slim Magnetic Power Bank 5K with BoostSolid Cell
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzSureFind Wallet Stand
Equipment Class
DTS - Digital Transmission SystemSureFind
Equipment Class
DTS - Digital Transmission SystemSoundForm Dot ANC Earbuds, SoundForm Dot Earbuds
Equipment Class
DTS - Digital Transmission System