Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 4 | 90,90.21 | 851 MHz - 870 MHz | 3.5 W | NOTE 1 | 1.5
ppm |
Grant NotesPower listed is rated conducted. Maximum conducted output power is 3.7 Watts per 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied for use with this product that provides at least 1.5 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.
The highest reported SAR values for head and body-worn accessories are: 1.28 W/kg; and 3.21 W/kg respectively accounting for a 50 % duty cycle.
NOTE 1: 11K0F3E, 16K0F3E, 8K10F1E, 8K10F1D