
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL HoME MoNitoRiNg StARtER Kit DHM-901t VERSioN 1.0 2D-Link DHM-901T User Manual D-Link reserves the right to revise this publication and to make changes in the content hereof without obligation to notify any person or organization of such revisions or changes. Manual Revisions trademarks D-Link and the D-Link logo are trademarks or registered trademarks of D-Link Corporation or its subsidiaries in the United States or other countries. All other company or product names mentioned herein are trademarks or regis- tered trademarks of their respective companies. Copyright © 2010 by D-Link Systems, Inc. All rights reserved. This publication may not be reproduced, in whole or in part, without prior expressed written per- mission from D-Link Systems, Inc. RevisionDateDescription 1.0November 15, 2010DHM-901T Revision A1 with firmware version 1.00 Preface 3D-Link DHM-901T User Manual table of Contents Product overview ........................................................4 Package Contents ...................................................4 System Requirements .............................................5 Features ..................................................................6 Hardware Overview: Gateway (Front) .....................7 Hardware Overview: Gateway (Back) .....................8 Hardware Overview: Keypad ...................................9 Hardware Overview: Contact Sensor ....................10 Hardware Overview: Motion Sensor ......................11 Hardware Installation: Gateway .............................12 Hardware Installation: Keypad ...............................13 Hardware Installation: Contact Sensor ..................14 Hardware Installation: Motion Sensor ....................15 Appendix A - technical Specifications ...................16 Technical Specifications ........................................16 4D-Link DHM-901T User Manual Product OverviewProduct Overview If any of the above items are missing, please contact your reseller. Package Contents DHM-401T Gateway DHM-301T Keypad DHM-303T Contact Sensor DHM-304T Motion Sensor Stand for DHM-401T Power adapter for DHM-401T Bracket for DHM-304T Batteries for DHM-301T/303T/304T Mounting kits for DHM-301T/303T/304T Ethernet cable Quick Installation Guide 5D-Link DHM-901T User Manual Product Overview System Requirements A computer with Windows XP SP2/Vista/7 or higher for configuration 6D-Link DHM-901T User Manual Product Overview Features Contact Sensor The DHM-303T Contact Sensor can be used to detect whether a door or window is open or closed. You can use this to provide security for windows, or to monitor entry and exit through a doorway, and can be used in tandem with other sensors and keypads to monitor and control access to an area. Motion Sensor The DHM-304T Motion Sensor can be used to detect motion in an area. You can change the sensor's motion detec- tion sensitivity to help you find the right balance to detect movement without false alarms. Heartbeat Service and Low Battery Notification Each sensor and keypad periodically sends a "heartbeat" signal to the gateway, which notifies you when the batter- ies in a sensor need to be changed, or if a sensor is out of range. Expandable System The two USB ports allow you to expand your home monitoring system by adding adapters such as a DWM-156 3G dongle for a 3G fallback Internet connection, or a DHM-101 Z-Wave USB Dongle to allow for connection to Z-Wave devices. 7D-Link DHM-901T User Manual Product Overview Hardware overview: gateway (Front) LEDs - Status - Alarm - Online - Event 8D-Link DHM-901T User Manual Product Overview Hardware overview: gateway (Back) USB Ports Connect to compatible USB devices, such as the DHM-101 Z-Wave USB Dongle. LAN Port Connects to your router. Learn/Reset Button Turns on pairing mode. Power Connector Connects to the included power adapter. 9D-Link DHM-901T User Manual Product Overview Hardware overview: Keypad LEDs - Active/Operation - Status - Alarm/Error Status Button Armed Home Button Armed Away Button Help Button Clear Events Button 10D-Link DHM-901T User Manual Product Overview Hardware overview: Contact Sensor Contact Sensor Piece Pairing Button and LED 11D-Link DHM-901T User Manual Product Overview Hardware overview: Motion Sensor Pairing Button and LED 12D-Link DHM-901T User Manual Product Overview Hardware installation: gateway inserting batteries into your DHM-401t gateway (optional) Remove the battery cover and insert 6 AAA batteries (not included) as indicated. Replace the battery cover. Connect the DHM-401t gateway Connect one end of the included Ethernet cable to an available LAN port on your router, and connect the other end to the WAN port on the DHM-401T. Connect the power adapter to the DHM-401T. 13D-Link DHM-901T User Manual Product Overview Hardware installation: Keypad inserting batteries into your DHM-301t Keypad Slide and remove the battery cover on the back of the keypad, then insert 2 AAA batteries as indicated. Replace the battery cover. Pairing the DHM-301t Keypad Press and hold the pairing button on the DHM-401T Gateway until you hear a beep and the Online Status LED flashes green. You now have 60 seconds to pair sensors to the gateway. Press and hold the 1 and 2 buttons on the DHM-301T Keypad at the same time. When the 2 devices have successfully paired, the DHM-401T gateway will beep 2 times, and the DHM-301T Key- pad will beep 4 times. Mounting the DHM-301t Keypad (optional) You can hang the keypad 2 different ways. You can push in and slide the D-Link logo up to uncover 2 screw holes you can use to mount the keypad to a wall using the included screws. Alternatively, you can insert the included screws into a wall, then use the mounting holes on the back of the key- pad to hang it on the screws. 14D-Link DHM-901T User Manual Product Overview Hardware installation: Contact Sensor inserting batteries into your DHM-303t Contact Sensor Use a coin to open the case, then l…
Text truncated - open the document above for the full version.
No.289, Sinhu 3rd Rd., Neihu District, Taipei City 114, Taiwan, R.O.C. TEL.:+ 886-2-66000123 FAX:+ 886-2-55509988 AUTHORIZATION LETTER Date:2010-11-23 To whom it may concern: We, the undersigned D-Link Corporation hereby authorize Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all matters relating to all processes required in FCC Part 15C and any communication needed with the national authority. Any and all acts carried out by BV CPS Taoyuan on our behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, ------------------------------------------------- KC Hsieh / Director D-Link Corporation TEL.:+ 886-2-66000123 # 5850 FAX:+ 886-2-55509988 E-mail: [email protected]
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4
100.5mm 49mm DHM-401T FCC ID : KA2HM401TA1 DHM-401TA1 IC : 4216A-HM401TA1 Model : DHM-401T 12V/2A
Label location
Page 5 Page 6 Page 7 Page 8
FCC ID: KA2HM401TA1 Report No.: RF990708C04 Technical Description The transceiver of the EUT (Home Monitoring Gateway) is powered by ac adapter. The antenna is Monopole printed antenna without antenna connector. The other instruction, please have a look at the users manual.
Report No.: RF990708C04 1 Report Format Version 3.0.1 FCC TEST REPORT REPORT NO.: RF990708C04 MODEL NO.: DHM-401T FCC ID : KA2HM401TA1 RECEIVED: Jun. 30, 2010 TESTED: Jul. 13 ~ Jul. 29, 2010 ISSUED: Aug. 04, 2010 APPLICANT : D-Link Corporation. ADDRESS : 17595 Mt. Herrmann, Fountain Valley, CA 92708, U.S.A. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS : No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien 244, Taiwan, R.O.C. TEST LOCATION : No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 33 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agency. The test results in the report only apply to the tested sample. Report No.: RF990708C04 2 Report Format Version 3.0.1 Table of Contents 4 CERTIFICATION ......................................................................................................... 3 5 SUMMARY OF TEST RESULTS................................................................................. 4 2.1 MEASUREMENT UNCERTAINTY .............................................................................. 4 6 GENERAL INFORMATION ......................................................................................... 5 6.2 GENERAL DESCRIPTION OF EUT............................................................................ 5 6.3 DESCRIPTION OF TEST MODES.............................................................................. 6 6.3.1 CONFIGURATION OF SYSTEM UNDER TEST ........................................................ 6 6.3.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL.............................. 7 6.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................. 9 6.5 DESCRIPTION OF SUPPORT UNITS........................................................................ 9 7 TEST PROCEDURE AND RESULT .......................................................................... 10 4.1 RADIATED EMISSION MEASUREMENT ................................................................. 10 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .............................................. 10 4.1.2 TEST INSTRUMENT................................................................................................. 11 4.1.3 TEST PROCEDURE ................................................................................................. 12 4.1.4 TEST SETUP ............................................................................................................ 13 4.1.5 EUT OPERATING CONDITION ................................................................................ 13 4.1.6 TEST RESULTS ........................................................................................................ 14 4.2 CONDUCTED EMISSION MEASUREMENT ............................................................ 18 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ......................................... 18 4.2.2 TEST INSTRUMENTS .............................................................................................. 18 4.2.3 TEST PROCEDURES ............................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ..................................................................... 19 4.2.5 TEST SETUP ............................................................................................................ 20 4.2.6 EUT OPERATING CONDITIONS.............................................................................. 20 7.2.1 TEST RESULTS ........................................................................................................ 21 4.3 20DB OCCUPIED BANDWIDTH MEASUREMENT.................................................. 25 4.3.1 LIMITS OF EMISSION BANDWIDTH MEASUREMENT .......................................... 25 4.3.2 TEST INSTRUMENT................................................................................................. 25 4.3.3 TEST PROCEDURE ................................................................................................. 25 4.3.4 DEVIATION FROM TEST STANDARD ..................................................................... 26 4.3.5 TEST SETUP ............................................................................................................ 26 4.3.6 TEST RESULTS ........................................................................................................ 26 4.4 DEACTIVATION TIME............................................................................................... 28 4.4.1 LIMITS OF DEACTIVATION TIME MEASUREMENT ............................................... 28 4.4.2 TEST INSTRUMENTS .............................................................................................. 28 4.4.3 TEST PROCEDURES ............................................................................................... 28 4.4.4 DEVIATION FROM TEST STANDARD ..................................................................... 28 4.4.5 TEST SETUP ............................................................................................................ 29 4.4.6 TEST RESULTS ........................................................................................................ 29 8 PHOTOGRAPHS OF THE TEST CONFIGURATION ............................................... 31 9 INFORMATION ON THE TESTING LABORATORIES.............................................. 32 10 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ........................................................................................ 33 Report No.: RF990708C04 3 Report Format Version 3.0.1 4 CERT…
Text truncated - open the document above for the full version.
1 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST (TEST MODE A) 2 CONDUCTED EMISSION TEST (TEST MODE B) 3 RADIATED EMISSION TEST (TEST MODE A) 4 RADIATED EMISSION TEST (TEST MODE B)
No. 19, Hwa Ya 2nd Rd., Kwei Shan Hsiang · Taoyuan Hsien · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 314.9972 MHz - 314.9972 MHz | - |
2K Pan & Tilt Outdoor Wi-Fi Camera
Equipment Class
DTS - Digital Transmission System
2K Fixed Indoor Cloud Camera, 2K Fixed Indoor Wi-Fi Camera
Equipment Class
DTS - Digital Transmission SystemWi-Fi 7 BE6500 USB 3.0 Dongle
Equipment Class
NII - Unlicensed National Information Infrastructure TXBE9500 Celling mount Access Point
Equipment Class
6ID - 15E 6 GHz Low Power Indoor Access PointAX900 Wi-Fi 6 USB Adapter, Wi-Fi 6 AX900 USB 2.0 Dongle
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter