FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lear Corporation/
  3. KOBGTE05A

KOBGTE05AMulti-Frequency Transmitter

Lear Corporation
Multi-Frequency Transmitter - FCC ID KOBGTE05A - Lear Corporation
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 05, 2006
Application Purpose
Original Equipment
Date of Application
Apr 05, 2006
Equipment Note
Multi-Frequency Transmitter
Frequency Range
390.00000000 - 390.00000000
Company
Lear Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Lear UGDO Lear UGDO Owner’s Guide Version 3.2 Page 1 3/27/2006 Lear Car2U Transmitter The Lear Universal Garage Door Opener (LEAR Car2U ™) is a universal transmitter and can replace up to three different remote control transmitter units used to operate the following types of devices: xGarage Door Opener xSecurity Devices xHome Lighting Systems Additional Lear Car2U ™ information can be found on the internet at www.learcar2U.com or by calling 1-866-57Car2U. Types of Garage Door Openers (Fixed Code and Rolling Code) Lear UGDO™ has the capability of programming rolling code and fixed code garage door openers: xRolling code garage door openers are used for garage doors produced after 1996 and are code protected. Rolling code means the coded signal is changed every time your remote control garage door opener is used. xFixed code garage door openers are used for garage doors produced prior to 1996. Fixed code uses the same coded signal every time, which is manually programmed by setting DIP switches for a unique personal code. If you do not know if your garage door opener is a rolling code or fixed code device, open your garage door opener’s remote control battery cover. If a panel of DIP switches is present as shown in the typical remote device shown below, your garage door opener is a fixed code device. If not, your garage door opener is a rolling code device. Lear UGDO Lear UGDO Owner’s Guide Version 3.2 Page 2 3/27/2006 Programming the Lear UGDO™ Transmitter Depending on your garage door opener manufacturer, Lear UGDO™ provides two easy ways to program your garage door opener. 1. Rolling Code Garage Door Openers: If your garage door opener is a rolling code device and do not have a row of dip switches use the “Programming Rolling Code Garage Door Opener” procedure on page 4. 2. Fixed Code Garage Door Opener: If your garage door opener is a fixed code device and has a row of dip switches use the “Programming Fixed Code Garage Door Opener” procedure on page 6. CAUTION xDo not use the Lear UGDO™ Transmitter with any garage door opener that does not have a “stop and reverse” feature. This includes any garage door opener model manufactured before April 1, 1982. xRead the instructions completely before attempting to program the LEAR UGDO™ transmitter. Because of the steps involved, it may be helpful to have another person assist you in programming the transmitter. xBe sure to keep the original remote control transmitter for use in other vehicles as well as for future Lear UGDO™ programming. You only need it for fixed code device programming. It is also recommended that upon the sale or lease termination of the vehicle, the programmed Lear UGDO™ buttons should be erased for security reasons. Refer to “Erasing Lear UGDO™ Buttons” or for assistance, contact Lear UGDO™ at 1- 866-57Car2U. xMake sure that people and objects are clear of the garage door opener or security device you are programming. When programming a garage door, it is advised to park outside the garage. PROGRAMING CONSIDERATIONS: ƒRead the instructions completely before attempting to program Car2U. ƒThe following items may assist you in programming the system: oA ladder oA screwdriver oA writing pad and a pencil or pen ƒIt may be helpful but is not required to have an additional person available when programming Car2U. ƒRetain the original transmitter for use in other vehicles as well as for future programming procedures (i.e. new Car2U-equipped vehicle purchase). ƒUpon the sale of the vehicle, it is recommended that the programmed Car2U buttons should be erased for security reasons (refer to “Erase Car2U Settings”). ƒRepeat the programming steps for each garage door opener you wish to program up to a maximum of three. Lear UGDO Lear UGDO Owner’s Guide Version 3.2 Page 3 3/27/2006 CAUTION Programming the Rolling Code Garage Door Opener involves time-sensitive actions. Read the ENTIRE procedure prior to beginning so you will know which actions are time-sensitive. If you do not follow the time-sensitive actions, the device will time out and you will have to repeat the procedure. Make sure that your key is ON and engine OFF while programming the transmitter. Use the following steps to program up to three different devices. Lear UGDO Lear UGDO Owner’s Guide Version 3.2 Page 4 3/27/2006 Programming Rolling Code Garage Door Opener or Device 1. Firmly PRESS the outer two Lear UGDO™ buttons for one — two seconds and immediately release them. 2. Go to the garage. Locate the garage door motor head and Press and Release its “learn” button. You may need a ladder to reach the unit and you may need to remove the unit’s cover to locate the “learn” button. After pressing the “learn” Button you have 10 to 30 seconds to complete Step 3 depending on your garage control unit If you cannot locate the “learn” button, refer to the Owner’s Guide of your garage door opener or call 1-866- 57Car2U. 3. Return to your vehicle, Press and HOLD the Car2U Button you would like to use to control the garage door. Immediately (within 1 second) release the button once the garage door begins to move. You may need to hold the button from 5 to 20 seconds during which time the selected button indicator light will blink slowly. Press ANY one of the three Lear UGDO™ buttons to assign the rolling code to the garage door opener. “Learn” Button shown on typical Rolling Code Garage Door Opener Lear UGDO Lear UGDO Owner’s Guide Version 3.2 Page 5 3/27/2006 4. The indicator light will blink rapidly until programming is complete Press and release the button again. The garage door should move confirming that programming is successful and complete. 5. To program another rolling code device such as an additional garage door opener, a security device, or home lighting, repeat steps 1 – 4 substituting a different function button in Step 3 than what you used for the garage door opener. For example, you could assign the left-most button to the garage door, the center button to a security d…

Text truncated - open the document above for the full version.

Attestation Statements

Re: Certification for Lear Transmitter Model(s): UHR FCC ID: KOBGTE05A POWER OF ATTORNEY A letter granting Valdis V. Liepa the Power of Attorney is on file and can be provided when so requested. Re: Certification for Lear Transmitter Model(s): UHR FCC ID: KOBGTE05A REQUEST FOR CONFIDENTIALITY Pursuant to 47 CRF 0.459, Lear requests that a part of the subject application be held confidential. This comprises Exhibits (4) Block Diagram (5) Schematics (10) Parts List and Placement (11) Description of Operation Lear has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. If there are any questions regarding this request, please contact me at the above address or call 734-483-4211, fax 734-647-2106 or e-mail [email protected]. Sincerely, Valdis V. Liepa Research Scientist University of Michigan Re: Certification for Lear Transmitter Model(s): UHR FCC ID: KOBGTE05A REQUEST FOR SHORT-TERM CONFIDENTIALITY Pursuant to 47 CRF 0.457 and 0.459, Lear requests that a part of the subject application be temporarily withheld from public disclosure for an initial period of 45 days. This comprises Exhibit(s) (3) External Photos (7) Test Setup Photos (8) User’s Manual (9) Internal Photos The device in question will not be available to the consumer until the 2007/2008 automotive model year. Thus, Lear requests that the above exhibits not be made public at this time. Lear will continue to request the short-term confidentiality every 45 day period, up to 180 days from the date of grant, as necessary prior to release of the device. If there are any questions regarding this request, please contact me at the above address or call 734-483-4211, fax 734-647-2106 or e-mail [email protected]. Sincerely, Valdis V. Liepa Research Scientist March 31, 2006 Re: Certification for Lear Transmitter Model(s): UHR FCC ID: KOBGTE05A STATEMENT OF MODIFICATIONS There were no modifications made to the DUT by this test laboratory. However, during product development this laboratory was used by the applicant to determine correct output power levels for the device over all operating frequencies. (Also see Section 3.1 of the attached Test Report). _____________________ Valdis V. Liepa Research Scientist

Cover Letter(s)

March 31, 2006 Federal Communications Commission Equipment Approval Services P.O. Box 358315 Pittsburgh, PA 15251-5315 Re: Certification for Lear Transmitter Model(s): UHR FCC ID: KOBGTE05A Please find enclosed application materials for certification of Lear UHR Transmitter. We tested it and found it to comply with FCC Part 15. If there are any questions regarding the application or testing performed, please contact me at the above address or call 734-483-4211, fax 734-647-2106, or e-mail [email protected]. Sincerely, Valdis V. Liepa Research Scientist

Cover Letter(s)

March 31, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: KOBGTE05A IC: 3521A-GTE05A Model(s): UHR Please find enclosed application materials for certification of Lear UHR multi-frequency transmitter. Note: 1) portions of this submittal are filed Confidential 2) a list of the modifications made is provided in Attestations. If there are any questions regarding the application or testing performed, please contact me at the above address or call 734-483-4211, fax 734-647-2106, or e-mail [email protected]. Sincerely, Valdis V. Liepa Research Scientist

External Photos

DUT with Harness DUT (top) DUT (bottom)

ID Label/Location Info

5200 Auto Club Dr. Dearborn, Michigan 48126-9982 (313) 593-9000 Date: March 27, 2006 RE: Lear Universal Transmitter Model # UHR FCC ID: KOBGTE05A (Proposed) FCC/IC Statement The following information will be placed in the user manual: FCC and RSS-210 Industry Canada Compliance If your vehicle is equipped with a Lear Car2U ™ transmitter, it complies with Part 15 of the FCC Rules. Operation is subject to two following conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received including interference that may cause undesired operation. FCC/IC Label Barcode Model Number/ Part Number Lear Serial Number Customer Serial Number Julian Date Code

Internal Photos

DUT apart (top) DUT apart (bottom) DUT apart (top) DUT apart (bottom) PCB (top) PCB can open PCB (bottom)

Test Report

University of Michigan Radiation Laboratory FCC Part 15, IC RSS-210/Gen - Test Report No. 415031-283 Page 1 of 21 The University of Michigan Radiation Laboratory 3228 EECS Building Ann Arbor, MI 48109-2122 Tel: (734) 764-0500 Measured Radio Frequency Emissions From Lear Corporation Car2U Transmitter Model(s): UHR Report No. 415031-283 March 29, 2006 Copyright © 2006 For: Lear Corporation 5200 Auto Club Dr. Dearborn, MI 48126-9982 Contact: Tom Tang Tel: 313-593 - 9934 Fax: 313-593-9526 PO: Verbal Tests supervised by: Measurements made by: Report approved by: _____________________ Valdis V. Liepa Valdis V. Liepa Joseph D. Brunett Research Scientist Summary Tests for compliance with FCC Regulations Part 15, Subpart C, and Industry Canada RSS-210/Gen, were performed on Lear Corporation model UHR. This device is subject to the Rules and Regulations as a Transmitter. In testing completed on March 23, 2006 the device tested in the worst case met the allowed FCC specifications for radiated emissions by 1.0 dB (see p. 7-9). Besides harmonics, there were no other significant spurious emissions found; emissions from digital circuitry were negligible. Line conducted emission tests do not apply since the device is powered from a 12 V dc system. University of Michigan Radiation Laboratory FCC Part 15, IC RSS-210/Gen - Test Report No. 415031-283 Page 2 of 21 1. Introduction Lear Corporation model UHR was tested for compliance with FCC Regulations, Part 15, adopted under Docket 87-389, April 18, 1989 as subsequently amended, and with Industry Canada RSS-210, Issue 6, September 2005. The tests were performed at the University of Michigan Radiation Laboratory Willow Run Test Range following the procedures described in ANSI C63.4-2003 "Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz". The Site description and attenuation characteristics of the Open Site facility are on file with FCC Laboratory, Columbia, Maryland (FCC Reg. No: 91050) and with Industry Canada, Ottawa, ON (File Ref. No: IC 2057). 2. Test Procedure and Equipment Used The pertinent test equipment commonly used in our facility for measurements is listed in Table 2.1 below. The middle column identifies the specific equipment used in these tests. Table 2.1 Test Equipment. Test Instrument Eqpt. Used Manufacturer/Model Spectrum Analyzer (0.1-1500 MHz) Hewlett-Packard, 182T/8558B Spectrum Analyzer (9kHz-22GHz) X Hewlett-Packard 8593A SN: 3107A01358 Spectrum Analyzer (9kHz-26GHz) X Hewlett-Packard 8593E, SN: 3412A01131 Spectrum Analyzer (9kHz-26GHz) Hewlett-Packard 8563E, SN: 3310A01174 Spectrum Analyzer (9kHz-40GHz) Hewlett-Packard 8564E, SN: 3745A01031 Power Meter Hewlett-Packard, 432A Power Meter Anritsu, ML4803A/MP Harmonic Mixer (26-40 GHz) Hewlett-Packard 11970A, SN: 3003A08327 Harmonic Mixer (40-60 GHz) Hewlett-Packard 11970U, SN: 2332A00500 Harmonic Mixer (75-110 GHz) Hewlett-Packard 11970W, SN: 2521A00179 Harmonic Mixer (140-220 GHz) Pacific Millimeter Prod., GMA, SN: 26 S-Band Std. Gain Horn S/A, Model SGH-2.6 C-Band Std. Gain Horn University of Michigan, NRL design XN-Band Std. Gain Horn University of Michigan, NRL design X-Band Std. Gain Horn S/A, Model 12-8.2 X-band horn (8.2- 12.4 GHz) Narda 640 X-band horn (8.2- 12.4 GHz) Scientific Atlanta , 12-8.2, SN: 730 K-band horn (18-26.5 GHz) FXR, Inc., K638KF Ka-band horn (26.5-40 GHz) FXR, Inc., U638A U-band horn (40-60 GHz) Custom Microwave, HO19 W-band horn(75-110 GHz) Custom Microwave, HO10 G-band horn (140-220 GHz) Custom Microwave, HO5R Bicone Antenna (30-250 MHz) X University of Michigan, RLBC-1 Bicone Antenna (200-1000 MHz) X University of Michigan, RLBC-2 Dipole Antenna Set (30-1000 MHz) X University of Michigan, RLDP-1,-2,-3 Dipole Antenna Set (30-1000 MHz) EMCO 2131C, SN: 992 Active Rod Antenna (30 Hz-50 MHz) EMCO 3301B, SN: 3223 Active Loop Antenna (30 Hz-50 MHz) EMCO 6502, SN:2855 Ridge-horn Antenna (300-5000 MHz) X University of Michigan Amplifier (5-1000 MHz) X Avantak, A11-1, A25-1S Amplifier (5-4500 MHz) X Avantak Amplifier (4.5-13 GHz) Avantek, AFT-12665 Amplifier (6-16 GHz) Trek Amplifier (16-26 GHz) Avantek LISN Box University of Michigan Signal Generator Hewlett-Packard 8657B University of Michigan Radiation Laboratory FCC Part 15, IC RSS-210/Gen - Test Report No. 415031-283 Page 3 of 21 3. Configuration and Identification of Device Under Test The DUT is a multi-frequency (8 frequencies total: 288MHz, 300MHz, 303MHz, 310MHz, 315MHz, 318MHz, 372MHz, and 390MHz) transmitter, 3 x 0.5 x 3 inches in size, designed to emulate existing garage door openers. This transmitter has pre-programmed protocols selected by the user based upon garage door receiver information. There are three buttons on the device so that the user may program a separate protocol to each button. There exist 2 protocols wherein both 315 MHz and 390 MHz are used sequentially during a single button press in normal operating mode; all other protocols transmit on only a single frequency in this mode. In programming mode the device may transmit on up to 4 frequencies in a sequential manner during a single button press. The details of these modes are outlined in the included documentation. The output power of the DUT is internally adjusted according to the RF frequency and data transmitted. Duty factors are calculated in software for all fixed code transmissions. For rolling code transmissions, the duty factor is computed for the worst case maximum on time. The antenna is mounted off the PCB. The DUT was designed and manufactured by Lear Corporation, 5200 Auto Club Dr., Dearborn, MI 48126-9982. It is identified as: Lear Corporation Transmitter Model: UHR FCC ID: KOBGTE05A Since the DUT is capable of transmitting a large number of different protocols over 8 different frequencies, the following test procedure has been followed. The lowest, middle, and highest frequencies have been tested for the worst case duty cycle (least on time i…

Text truncated - open the document above for the full version.

Test Setup Photos

DUT on OATS DUT on OATS (close-up)

Contact Information

Applicant

Kristof von Czarnowski(RF Engineer)
[email protected]248-421-0714Fax: 0

Technical Contact

University of MichiganValdis Liepa
[email protected]734-483-4211

1301 Beal Ave. · Ann Arbor, Michigan · United States

Test Firm

University of MichiganValdis Liepa
[email protected]734-647-1792Fax: 734-647-2106

Technical Specifications

#Rule PartsFrequency RangePower Output
815.231390 MHz - 390 MHz-
Confidentiality
Long Term

Other Applications from Lear Corporation

RKE Transmitter with UWB - FCC ID KOBJXF23B - Lear Corporation
KOBJXF23B

RKE Transmitter with UWB

Jul 20, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
RKE Transmitter with UWB - FCC ID KOBJXF23A - Lear Corporation
KOBJXF23A

RKE Transmitter with UWB

Sep 26, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Security/Remote Control Transmitter - FCC ID KOBHT13BTPM - Lear Corporation
KOBHT13BTPM

Security/Remote Control Transmitter

Oct 15, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KOBATA12A

Remote keyless entry / Remote start

Jun 20, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Car2U System TX - FCC ID KOBGTE12A - Lear Corporation
KOBGTE12A

Car2U System TX

Apr 20, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter