Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 06, 2011
Application Purpose
Original Equipment
Date of Application
Apr 06, 2011
Equipment Note
Keyless Entry System
Frequency Range
433.92000000 - 433.92000000
Company
Continental Automotive Technologies GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Annex no. 5 User Manual Statement m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 certified DAkkS accreditation number: D-PL-12053-01 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 FCC ID: KR55WK50083 IC Certification Number: 7812D-5WK50083 Subject: Compliance Statement in Car Manual Dear Sirs, The Continental products are marketed together with cars, where it’s operation is included in the individual owner’s manual of the car. We hereby assure that the following will be included in a prominent location of the owner’s manual of the cars: The title “CAUTION TO USERS” or “FCC WARNING”: “NOTE” or relevant title and “Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.” This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Le prĂ©sent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisĂ©e aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂ©lectrique subi, mĂŞme si le brouillage est susceptible d'en compromettre le fonctionnement. If you have any questions, please feel free to contact me at the address shown below. Yours sincerely, Signature: Date: 2011-02-21 NAME : Andreas Morsbach TITLE : Assistant Manager COMPANY : m. dudde hochfrequenz-technik TEL/FAX : +49 (0)2207 9689 0 /+49 (0)2207 9689 20 EMAIL : [email protected]

Cover Letter(s)

m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 zertifiziert Akkreditiertes Testhaus- Reg.-Nr.: DAT-P-225/96-02 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com Request for Confidentiality Date: 2011-02-22 RE: Certification Application FCC ID: KR55WK50083 Confidentiality Request To whom it may concern: Pursuant to Sections 0.457 (d) (1) (ii) and 0.459 of the Commission’s Rules, our customer hereby requests confidential treatment of information accompanying as outlined below: ď‚· Block diagram ď‚· Block diagram description / Operational description ď‚· Schematics ď‚· Parts list The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to our customer and provide unjustified benefits to their competitors. Thank you for your attention in this matter. m. dudde hochfrequenz-technik Andreas Morsbach Assistant Manager

External Photos

State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 1 External Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920

ID Label/Location Info

State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 4 Label Sample State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Label sample Continental Model: 5WK50083 FCC ID: KR55WK50083 IC: 7812D-5WK50083 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Label location

Internal Photos

State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 2 Internal Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920

Test Report

State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 3 Occupied Bandwidth Plot State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 20 dB bandwidth State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 99% bandwidth

Test Report

State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 11 Transmission Time Operation Characteristics State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. Open button Close button release point release point State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Trunk button release point State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Transmission Time / Averaging correction factor Open button State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 worst case transmission for the "open button" in any 100 ms time period during any pulse train = 34.2246 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Close button State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 worst case transmission for the "open button" in any 100 ms time period during any pulse train = 34.2936 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Trunk button State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 worst case transmission for the "open button" in any 100 ms time period during any pulse train = 34.3986 ms Calculating the averaging factor The worst case transmission time is 34.3986 ms in a 100 ms time sweep. The averaging factor was calculated by the following formula: averaging factor = 20*lg (TX ON / 100 ms) = 20*lg (34.3986 / 100 ms) = -9.2 dB

Test Report

Test report no. 10006647 Page 1 of 33 EUT: 5WK50083 FCC ID: KR55WK50083 Date of issue: 2011-02-22 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to Continental Automotive GmbH 5WK50083 Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 10006647 Page 2 of 33 EUT: 5WK50083 FCC ID: KR55WK50083 Date of issue: 2011-02-22 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Manufacturer’s details Manufacturer Continental Automotive GmbH Manufacturer‟s grantee code KR5 Manufacturer‟s address Continental Automotive GmbH Siemenstrasse 12 D-93005 Regensburg Germany Phone: +49 0941 790 6699 Fax: +49 941 790 996699 Email: [email protected] Relevant standard used 47 CFR Part 15C - Intentional Radiators ANSI C63.4-2009 Test report prepared by Technical engineer Ralf Trepper m.dudde hochfrequenz-technik (laboratory) Rottland 5a 51429 Bergisch Gladbach Germany Phone: +49 2207 96890 Fax: +49 2207 968920 Email: [email protected] Equipment Under Test (EUT) Equipment category Transmitter Trade name Continental Type designation 5WK50083 Serial no. --- Variants --- Test report no. 10006647 Page 3 of 33 EUT: 5WK50083 FCC ID: KR55WK50083 Date of issue: 2011-02-22 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 1. Test result summary CFR Section Report Chapter Requirements Headline Test result 15.203 11.1 Antenna requirement Pass Fail N.t. 15.205 11.2 Restricted bands of operation Pass Fail N.t. 15.209 11.3 Radiated emission limits, general requirements Pass Fail N.t. 15.231(a) 11.4 Periodic operation characteristics Pass Fail N.t. 15.231(b) 11.5 Fundamental frequencies / Field strength limits Pass Fail N.t. 15.231(c) 11.6 Bandwidth (20 dB) Pass Fail N.t. 15.201 (a) / 15.209 11.7 Equipment authorization requirement Pass Fail N.t. The equipment meets the requirements Yes No Signature: .............................. Signature: .............................. (Technician) (Manager) Test report no. 10006647 Page 4 of 33 EUT: 5WK50083 FCC ID: KR55WK50083 Date of issue: 2011-02-22 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Table of contents 1. Test result summary .......................................................................................................................................... 3 2. Test laboratory .................................................................................................................................................. 6 3. Introduction ...................................................................................................................................................... 6 4. Product ............................................................................................................................................................. 7 5. Test schedule .................................................................................................................................................... 7 6. Product and measurement documentation ......................................................................................................... 8 7. Observations and comments ............................................................................................................................. 8 8. Summary........................................................................................................................................................... 8 9. Conclusions ...................................................................................................................................................... 9 10. Operational description ................................................................................................................................... 10 11.1 Antenna requirement ..................................................................................................................................... 11 11.1.1 Regulation ........................................................................................................................................... 11 11.1.2 Result .................................................................................................................................................. 11 11.2 Restricted bands of operation ........................................................................................................................ 12 11.2.1 Regulation ........................................................................................................................................... 12 11.2.2 Result .................................................................................................................................................. 14 11.3 Radiated emission limits, general requirements ............................................................................................ 15 11.3.1 Regulation ........................................................................................................................................... 15 11.3.2 Test equipment ................................................................................................................................... 16 11.3.3 Test procedure .................................................................................................................................... 17 11.3.4 Calculation of the field strength ......................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 6 Test Setup Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920

Contact Information

Applicant

Thomas Heselberger
[email protected]49-941-790-3554Fax: 49-941-790-903554

Test Firm

m. dudde hochfrequenz-technikManfred Dudde
[email protected]49-2207-9689-0Fax: 49-2207-9689-20

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Continental Automotive Technologies GmbH

KR5FERKEY25

Romete Car Key

Jul 06, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KR5KAM01

KAM (Key Authentication Module)

May 12, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
KR5HFM501

Hand Free Module

Apr 29, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
KR5TXPZ6

Radio Frequency Transmitter

Mar 05, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KR5TXPZ5

TXPZ5

Mar 05, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter