FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Continental Automotive Technologies GmbH/
  3. KR55WY8462

KR55WY8462Radio Frequency Transmitter

Continental Automotive Technologies GmbH
Radio Frequency Transmitter - FCC ID KR55WY8462 - Continental Automotive Technologies GmbH
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 14, 2007
Application Purpose
Original Equipment
Date of Application
Jun 14, 2007
Equipment Note
Radio Frequency Transmitter
Frequency Range
315.00000000 - 315.00000000
Company
Continental Automotive Technologies GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 5 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EuT 5WY8462 T31728-01-00KG External Photo Top view 5WY8462 T31728-01-00KG External Photo Rear view

ID Label/Location Info

FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 5 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EuT 5WY8462 T31728-01-00KG External Photo Top view 5WY8462 T31728-01-00KG External Photo Rear view

Internal Photos

FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 6 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5WY8462 T31728-01-00KG Internal Photo FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 7 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5WY8462 T31728-01-00KG Internal Photo Top view of PCB 5WY8462 T31728-01-00KG Internal Photo Rear view of PCB

Test Report

FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 1 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 EMI -- T E S T R E P O R T Test Report No. : T31728-01-00KG 24. May, 2007 ______________________________________________________________________________________________ Date of issue Type / Model Name : 5WY8462 Product Description : Radio Frequency Transmitter Applicant : Siemens AG, Siemens VDO Automotive Address : Siemensstrasse 12 D – 93055 Regensburg Manufacturer : Siemens AG, Siemens VDO Automotive Address : Siemensstrasse 12 D – 93055 Regensburg Licence holder : Siemens AG, Siemens VDO Automotive Address : Siemensstrasse 12 D – 93055 Regensburg Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test DAT-P-207/05-00 laboratory. FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 2 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 Contents 1 TEST STANDARDS 3 2 SUMMARY 4 3 EQUIPMENT UNDER TEST 5 3.1 PHOTO DOCUMENTATION OF THE EUT 5 3.2 POWER SUPPLY SYSTEM UTILISED 8 3.3 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) 8 4 TEST ENVIRONMENT 9 4.1 ADDRESS OF THE TEST LABORATORY 9 4.2 ENVIRONMENTAL CONDITIONS 9 4.3 STATEMENT OF THE MEASUREMENT UNCERTAINTY 9 4.4 MEASUREMENT PROTOCOL 9 5 TEST CONDITIONS AND RESULTS 11 5.1 CONDUCTED EMISSIONS 11 5.2 RADIATED POWER OF THE FUNDAMENTAL WAVE 12 5.3 SPURIOUS EMISSIONS (MAGNECTIC FIELD) 9 KHZ – 30 MHZ 14 5.4 RADIATED EMISSIONS (ELECTRIC FIELD) 30 MHZ – 18 GHZ 17 5.5 EMISSION BANDWIDTH 21 5.6 SIGNAL DEACTIVATION 23 6 USED TEST EQUIPMENT AND ACCESSORIES 25 FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 3 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 1 TEST STANDARDS The tests were performed according to following standards: FCC Rules and Regulations Part 15 Subpart C - Intentional Radiators (October 01, 2006) Part 15, Subpart C, Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz §15.231(a) Signal deactivation §15.231(b) Radiated emissions, Fundamental & Harmonics §15.231(c) Emission Bandwidth Part 15, Subpart C, Section 15.207(a) AC Line conducted emissions Part 15, Subpart C, Section 15.209(a) Radiated emissions, general requirements FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 4 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 2 SUMMARY GENERAL REMARKS: None FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 23. May 2007 Testing concluded on : 24. May 2007 Checked by: Tested by: Thomas Weise Dipl.-Ing.(FH) Laboratory Manager Klaus Gegenfurtner Dipl.-Ing.(FH) FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 5 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EuT 5WY8462 T31728-01-00KG External Photo Top view 5WY8462 T31728-01-00KG External Photo Rear view FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 6 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5WY8462 T31728-01-00KG Internal Photo FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 7 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5WY8462 T31728-01-00KG Internal Photo Top view of PCB 5WY8462 T31728-01-00KG Internal Photo Rear view of PCB FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 8 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 3.2 Power supply system utilised Power supply voltage : 3V / DC 3.3 Short description of the Equipment under Test (EuT) The EuT is a wireless handheld transmitter of a keyless entry system for vehicles. Number of tested samples: 2 Serial number: Prototype EuT operation mode: The equipment under test was operated during the measurement under the following conditions: - TX mode at 315 MHz - - EuT configuration: (The CDF filled by the applicant can be viewed at the test laboratory.) The following peripheral devices and interface cables were connected during the measurements: - Model : - Model : - Model : - Model : - Model : - Model : FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 9 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 4 TEST ENVIRONMENT 4.1 Address of the test laboratory mikes-testingpartners gmbh Ohmstrasse 2-4 94342 Strasskirchen Germany 4.2 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 86-106 kPa 4.3 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit modelling – Uncertainty in EMC measurements“ and is documented in the quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 4.4 Measurement Protoco…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 12 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5.2 Radiated power of the fundamental wave For test instruments and accessories used see section 6 Part CPR 2. 5.2.1 Description of the test location Test location: OATS1 Test distance: 3 metres 5.2.2 Photo documentation of the test set-up FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 14 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5.3 Spurious emissions (Magnectic field) 9 kHz – 30 MHz For test instruments and accessories used see section 6 Part SER 1. 5.3.1 Description of the test location Test location: OATS1 Test distance: 3 metres 5.3.2 Photo documentation of the test set-up FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 17 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5.4 Radiated emissions (electric field) 30 MHz – 18 GHz For test instruments and accessories used see section 6 Part SER 2, SER 3. 5.4.1 Description of the test location Test location: OATS1 Test location: Anechoic Chamber A2 Test distance: 3 metres 5.4.2 Photo documentation of the test set-up FCC ID: KR55WY8462 mikes-testingpartners gmbh File No. T31728-01-00KG, page 18 of 25 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1 5.4.3 Description of Measurement Radiated spurious emissions from the EuT are measured in the frequency range of 30 MHz to 1000 MHz using a tuned receiver and appropriate broadband linearly polarized antennas. Measurements between 30 MHz and 1000 MHz are made with 120 kHz/6 dB bandwidth and quasi-peak detection. Table top equipment is placed on a 1.0 X 1.5 meter non-conducting table 80 centimetres above the ground plane. Floor standing equipment is placed directly on the turntable/ground plane. The set up of the Equipment under test will be in accordance to ANSI C63.4-2003. The Interface cables that are closer than 40 centimetres to the ground plane are bundled in the center in a serpentine fashion so they are at least 40 centimetres from the ground plane. Cables to simulators/testers (if used in

Contact Information

Applicant

Thomas Heselberger
[email protected]49-941-790-3554Fax: 49-941-790-903554

Technical Contact

mikes-testingpartners gmbhKlaus Gegenturtner
[email protected]+49 9424 9481 350

Ohmstrasse 2-4 · Strasskirchen · Germany

Test Firm

CSA Group Bayern GmbHThomas Weise
[email protected]49-9424-9481-150Fax: 49-9424-9481-240

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from Continental Automotive Technologies GmbH

KR5FERKEY25

Romete Car Key

Jul 06, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KR5KAM01

KAM (Key Authentication Module)

May 12, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
KR5HFM501

Hand Free Module

Apr 29, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
KR5TXPZ6

Radio Frequency Transmitter

Mar 05, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KR5TXPZ5

TXPZ5

Mar 05, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter