Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Continental I BS 1 of 2 Owner manual Immobilization system for Ford V36x Carline Type A2C95937800 Continental I BS 2 of 2 General: The Immobilizer is part of the PATS system and is mounted at the Steering lock. The IMMO has 2 Functionalities. 1. Read out the Code of the Transponder which are mounted in the Vehicle Key to release the engine start. 2. Charge the Battery of the Vehicle key wireless during driving. Owner Manual Information: Canada: Model: A2C95937800 IC:7812D-A2C95937800 This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference (2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d'Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes:(1) Cet appareil ne doit pas causer d'interférences (2) Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l'appareil. USA: FCC ID:KR5A2C95937800 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
@ntinentals PHOENIX TESTLAB GmbH Product Certification Department Königswinkel i0 D 32825 Blomberg To Whom lt May Concern: Please be advised that we Continental Automotive GmbH, Siemensstr. 12, 93055 Regensburg) authorizes the following persons from EMV Testhaus GmbH: . Mr. Tobias Zollner . Mr. Christian Kiermeier ¡ Mr. Konrad Graßl to handle the application of Type Approval Services for the following coutries: USA Canada Unless future correspondence from us, please extend your full cooperation to EMV Testhaus GmbH regarding, matters to 6 months after the signatory date of this authorization. Contact person Dagmar Kolar Position in the company Type approval Manager Date of signatory 2019-10-14 e? f natory (signature of the applicant)
@ntinentals Long/Short-term Confldential itv Reo uest PHOENIX TESTLAB GmbH Date: 10 December 2019 Product Certification Königswinkel 10 D 32825 Blomberg FCC lD: KR542C95937800 To Whom lt May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long{erm confidential treatment of information accompanying this application as outlined below: X Schematics X Block Diagram X Operational Description tr External Photos tr lnternal Photos ln addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure n for an initial period of _ days n until: X not applicable X Pàrts List n Tune-Up lnfo tr Test Setup Photos E Users Manuàl The above materials contain trade secrets and proprietary information not customarily released to the public. Ïhe public disclosure of these matters might be harmful to the applicant and provide uhjustified benefits to.its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application lf you have any questions, please feel free to contact me. Yours sincerely, Þ1)a7nrr Dagmar Kolar Type approval Manager
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex B Page 1 of 3 1 Annex B – EUT pictures 1.1 List of Pictures Picture 1: EUT front side.................................................................................................... 2 Picture 2: EUT back side ................................................................................................... 2 Picture 3: Name plate of EUT ............................................................................................ 3 Picture 4: Wiring harness................................................................................................... 3 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex B Page 2 of 3 Picture 1: EUT front side Picture 2: EUT back side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex B Page 3 of 3 Picture 3: Name plate of EUT Picture 4: Wiring harness
LABEL DRAFT – Canada, USA - Continental Immobilizer A2C95937800 Continental Model : A2C95937800 FCC ID:KR5A2C95937800 IC:7812D-A2C95937800
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex C Page 1 of 5 1 Annex C – internal pictures 1.1 List of Pictures Picture 1: Rear view of covering cap ................................................................................. 2 Picture 2: Front view of EUT without covering cap ............................................................ 2 Picture 3: Top view of EUT without covering cap .............................................................. 3 Picture 4: Top view of PCB ................................................................................................ 3 Picture 5: Bottom view of PCB ........................................................................................... 4 Picture 6: Bottom view of EUT with PCB ........................................................................... 4 Picture 7: Bottom view of EUT without PCB ...................................................................... 5 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex C Page 2 of 5 Picture 1: Rear view of covering cap Picture 2: Front view of EUT without covering cap EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex C Page 3 of 5 Picture 3: Top view of EUT without covering cap Picture 4: Top view of PCB EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex C Page 4 of 5 Picture 5: Bottom view of PCB Picture 6: Bottom view of EUT with PCB EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex C Page 5 of 5 Picture 7: Bottom view of EUT without PCB
All test results relate to the items tested only. For reproduction of extracts of this test report, the written approval of EMV TESTHAUS GmbH is required. Applicant: Continental Automotive GmbH Regensburg Siemensstraße 12 93055 Regensburg Tel.: +49 941 790-0 Fax: +49 941 790-136699 Test report no.: 190706-AU03+W01 for: Continental Automotive GmbH Regensburg Immobilizer A2C95937800 according to: Part 2 RSS 102 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W01 Page 2 of 24 Accreditation: FCC test firm accreditation expiration date: 2021-05-30 MRA US-EU, FCC designation number: DE0010 FCC registration number: 97268 BnetzA-CAB-02/21-02/5 Valid until 2023-11-26 Recognized on March 14 th , 2019 by the Department of Innovation, Science and Economic Development (ISED) Canada as a wireless testing laboratory CAB identifier: DE0011 ISED#: 3472A Location of Testing: EMV TESTHAUS GmbH Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Gustav-Hertz-Straße 35 94315 Straubing, Germany The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH. EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W01 Page 3 of 24 Table of contents 1 Test regulations ........................................................................................................................ 5 2 Summary of test results ............................................................................................................ 6 3 Equipment under test (EUT) ..................................................................................................... 7 4 Photographs of EUT ................................................................................................................. 7 5 Test results ............................................................................................................................... 8 5.1 FCC ................................................................................................................................... 9 5.2 Canada ............................................................................................................................ 16 6 Revision history ...................................................................................................................... 24 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W01 Page 4 of 24 List of pictures Picture 1: Setup of magnetic field test at a measurement distance of 8 cm, mode 2 ...................... 11 Picture 2: Setup of electric field test at a measurement distance of 8 cm, mode 2 ......................... 11 Picture 3: Setup of magnetic field test at a measurement distance of 0 cm ................................... 18 Picture 4: Setup of electric field test at a measurement distance of 0 cm, mode 2 ......................... 18 List of tables Table 1: Devices used for testing .................................................................................................... 9 Table 2: Limits for Maximum Permissible Exposure (MPE) to RF electromagnetic fields ............... 12 Table 3: RF exposure test results at measurement distance 8 cm ................................................. 14 Table 4: Measurement uncertainties.............................................................................................. 15 Table 5: Equipment calibration status ............................................................................................ 15 Table 6: Devices used for testing .................................................................................................. 16 Table 7: Electric field strength reference levels ............................................................................. 19 Table 8: Magnetic field strength reference levels ........................................................................... 19 Table 9: Limb exposure limit relaxation ......................................................................................... 21 Table 10: RF exposure test results according to RSS-102 at a distance of 0 cm, mode 2 ............. 22 Table 11: Measurement uncertainties ............................................................................................ 23 Table 12: Equipment calibration status .......................................................................................... 23 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W01 Page 5 of 24 1 Test regulations Standard Title RSS-102 Issue 5 March 2015 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radio communication Apparatus (All Frequency Bands) SPR-002 Issue 1 September 2016 Spectrum Management and Telecommunications Supplementary Procedure Supplementary Procedure for Assessing Compliance with RSS-102 Nerve Stimulation Exposure Limits Safety Code 6 (2015) Limits of Human Exposure to Radiofrequency Electromagnetic Energy in the Frequency Range from 3 kHz to 300 GHz IEEE C95.3-2002 (R2008) Approved December 11, 2002 Reaffirmed June 12, 2008 IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz–300 GHz KDB 680106 D01 May 31, 2013 (published by the Federal Communications Commission FCC) RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications OET Bulletin 65, 65A, 65B Edition 97-01, August 1997 Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields Part 1, Subpart I, Section 1.1310 Radiofrequency radiation exposure limits Par…
Text truncated - open the document above for the full version.
V All test results relate to the items tested only. For reproduction of extracts of this test report, the written approval of EMV TESTHAUS GmbH is required. Applicant: Continental Automotive GmbH Siemensstraße 12 93055 Regensburg Tel.: +49 941 790-0 Test report no.: 190706-AU01+W01 for: Continental Automotive GmbH Immobilizer A2C95937800 according to: 15.209 RSS-GEN EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Page 2 of 40 Accreditation: FCC test firm accreditation expiration date: 2021-05-30 MRA US-EU, FCC designation number: DE0010 FCC registration number: 97268 BnetzA-CAB-02/21-02/5 Valid until 2023-11-26 Recognized on March 14 th , 2019 by the Department of Innovation, Science and Economic Development (ISED) Canada as a wireless testing laboratory CAB identifier: DE0011 ISED#: 3472A Location of Testing: EMV TESTHAUS GmbH Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Gustav-Hertz-Straße 35 94315 Straubing, Germany The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH. EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Page 3 of 40 Table of contents 1 Summary of test results ............................................................................................................ 6 2 Referenced publications ........................................................................................................... 8 3 Equipment under test (EUT) ..................................................................................................... 9 3.1 General information ........................................................................................................... 9 3.2 Radio specifications ......................................................................................................... 10 3.3 Photo documentation ....................................................................................................... 10 4 Test configuration and mode of operation ............................................................................... 11 4.1 Test configuration ............................................................................................................ 11 4.2 Mode of operation ............................................................................................................ 11 5 Test procedures...................................................................................................................... 12 5.1 General specifications ..................................................................................................... 12 5.2 Radiated emissions below 30 MHz .................................................................................. 12 5.3 Radiated emissions from 30 MHz to 1 GHz ..................................................................... 15 5.4 Radiated emissions above 1 GHz .................................................................................... 16 5.5 Bandwidth measurements ............................................................................................... 19 5.6 Restricted bands of operation .......................................................................................... 20 6 Test results ............................................................................................................................. 21 6.1 20 dB bandwidth .............................................................................................................. 22 6.2 Occupied bandwidth ........................................................................................................ 25 6.3 Restricted band of operation from 0.090 MHz to 0.110 MHz ............................................ 28 6.4 Emissions outside the operating frequency band(s) specified .......................................... 31 7 Equipment calibration status ................................................................................................... 38 8 Measurement uncertainties .................................................................................................... 39 9 Revision history ...................................................................................................................... 40 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Page 4 of 40 List of figures Figure 1: Setup for radiated emissions test below 30 MHz ............................................................ 14 Figure 2: Setup for radiated emissions test from 30 MHz to 1 GHz ............................................... 16 Figure 3: Setup for radiated emissions test above 1 GHz .............................................................. 19 Figure 4: Chart of 20 dB bandwidth with vehicle key ..................................................................... 24 Figure 5: Chart of occupied bandwidth test with vehicle key .......................................................... 27 Figure 6: Restricted band of operation ........................................................................................... 30 Figure 7: Chart of emissions test below 30 MHz with key in position 1 .......................................... 33 Figure 8: Chart of emissions test from 30 MHz to 1 GHz without key in position 1......................... 37 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Page 5 of 40 List of tables Table 1: Devices used for testing .................................................................................................. 11 Table 2: Recalculation factors for extrapolation ............................................................................. 13 Table 3: Bandwidt…
Text truncated - open the document above for the full version.
The test result refers exclusively to the model tested. This test report may not be copied or published in extracts without the written authorization of the accreditation agency and/or EMV TESTHAUS GmbH Applicant: Continental Automotive GmbH Regensburg Siemensstraße 12 93055 Regensburg Tel.: +49 941 790-0 Fax: +49 941 790-136699 Test report no.: 190706-AU03+W03 for: Continental Automotive GmbH Regensburg Immobilizer A2C95937800 according to: 15.209 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W03 Page 2 of 31 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: FCC test firm accreditation expiration date: 2021-05-30 MRA US-EU, FCC designation number: DE0010 FCC registration number: 97268 BnetzA-CAB-02/21-02/5 Valid until 2023-11-26 Location of Testing: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH. EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W03 Page 3 of 31 Table of contents 1 Summary of test results ............................................................................................................ 5 2 Referenced publications ........................................................................................................... 6 3 Equipment under test (EUT) ..................................................................................................... 7 3.1 General information ........................................................................................................... 7 3.2 Radio specifications ........................................................................................................... 8 4 Photo documentation ................................................................................................................ 8 5 Test configuration and mode of operation ................................................................................. 9 5.1 Test configuration .............................................................................................................. 9 5.2 Mode of operation .............................................................................................................. 9 6 Test procedures...................................................................................................................... 10 6.1 General specifications ..................................................................................................... 10 6.2 Radiated emissions below 30 MHz .................................................................................. 10 6.2.1 Extrapolation according to ANSI C63.10 ................................................................... 10 6.2.2 Measuring radiated emissions below 30 MHz ........................................................... 11 6.3 Radiated emissions from 30 MHz to 1 GHz ..................................................................... 13 6.4 Bandwidth measurements ............................................................................................... 15 6.4.1 20 dB bandwidth of the emission .............................................................................. 15 7 Test results ............................................................................................................................. 16 7.1 Restricted bands of operation .......................................................................................... 17 7.1.1 Test equipment ......................................................................................................... 17 7.1.2 Limits ........................................................................................................................ 18 7.1.3 Test procedure .......................................................................................................... 18 7.1.4 Test results ............................................................................................................... 19 7.2 Radiated emissions ......................................................................................................... 20 7.2.1 Radiated emissions below 30 MHz ........................................................................... 20 7.2.2 Radiated emissions from 30 MHz to 1 GHz .............................................................. 23 7.3 20 dB bandwidth .............................................................................................................. 26 7.3.1 Test equipment ......................................................................................................... 26 7.3.2 Limits ........................................................................................................................ 27 7.3.3 Test procedure .......................................................................................................... 27 7.3.4 Test results ............................................................................................................... 28 8 Equipment calibration status ................................................................................................... 29 9 Measurement uncertainties .................................................................................................... 30 10 Revision history ...................................................................................................................... 31 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Continental Automotive GmbH Regensburg Immobilizer A2C95937800 190706-AU03+W03 Page 4 of 31 List of figures Figure 1: Setup for radiated emissions test below 30 MHz ...........................................…
Text truncated - open the document above for the full version.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 1 of 7 1 Annex A – Test setup 1.1 List of Pictures Picture 1: EUT test setup radiated emission test 9 kHz – 30 MHz (front view) .................. 2 Picture 2: EUT test setup radiated emission test 9 kHz – 30 MHz (rear view) ................... 2 Picture 3: EUT test setup radiated emission test 30 MHz – 1 GHz (front view) ................. 3 Picture 4: EUT test setup radiated emission test 30 MHz –1 GHz (rear view) ................... 3 Picture 5: EUT position 1 ................................................................................................... 4 Picture 6: EUT position 2 ................................................................................................... 4 Picture 7: EUT position 3 ................................................................................................... 5 Picture 5: Homologation box – top view ............................................................................ 5 Picture 6: Homologation box – bottom view....................................................................... 6 Picture 7: Vehicle key – top view ....................................................................................... 6 Picture 8: Vehicle key – bottom view ................................................................................. 7 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 2 of 7 Picture 1: EUT test setup radiated emission test 9 kHz – 30 MHz (front view) Picture 2: EUT test setup radiated emission test 9 kHz – 30 MHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 3 of 7 Picture 3: EUT test setup radiated emission test 30 MHz – 1 GHz (front view) Picture 4: EUT test setup radiated emission test 30 MHz –1 GHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 4 of 7 Picture 5: EUT position 1 Picture 6: EUT position 2 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 5 of 7 Picture 7: EUT position 3 Picture 8: Homologation box – top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 6 of 7 Picture 9: Homologation box – bottom view Picture 10: Vehicle key – top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Continental Automotive GmbH Immobilizer A2C95937800 190706-AU01+W01 Annex A Page 7 of 7 Picture 11: Vehicle key – bottom view
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |
Romete Car Key
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterKAM (Key Authentication Module)
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzHand Free Module
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzRadio Frequency Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterTXPZ5
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter