Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TAB LE OF CON TEN TS Safety& OperatingInformation. . . . . . . .1 St eamGenie InterfaceModule Installation2 Ba tteryReplacement. . . . . . . . . . . . . . . .2 St eamGenie Operatio n . . . . . . . . . . . . . .3 Steam GenieInterfaceModule Operatio n. .3 Pairi ng. . . . . . . . . . . . . . . . . . . . . . . . .4 Troublesho oting. . . . . . . . . . . . . . . . . . .4 Lis t of ReplacementParts. . . . . . . . . . . .4 __ ___________________ ___ __ ____ __ ________________ BOXCONTENT • SteamGen ie • In terfaceModule • Lanyard •5ft.InterfaceModuleConnectionCable •2In terfaceModule mountingScrews • In stallation andOp erationInstructions __ ___________________ ___ __ ____ __ ________________ IM PO RT ANTNO TE: Asyoufollowth eseinstructions,youwillnoticewarning an d cautionsymbols. Th is blockedinformationis important forthesafe an d ef ficient installationandoperationof this SteamGe nie.These ar e twoty pesof potentialhazardsthat may occurduringth is installationandoperation: st at es a haz ard whi ch may cause serious injury or death if prec auti ons are not followed. si gnal s a situationwhere minor injury or productdamagemay oc cu r if you do not foll ow instruc ti ons. IMPORTANT NO TE: THIS HIG HLI GHTS IN FORMAT ION THA T IS ES PECIALLY RE LEV ANT TO A PRO BLEM-FREEINS TALLAT ION. PUR1004496/10 WARNING ! CAUTION ! mr . steam ® St eamGen ie ™ Wi relessCo nt rolIn st al lation andOperationInstructions _________________________________________________ mr . steam ® Su ss man-Automat ic Corp ® in fo @mrsteam.com www.mrsteam.com 43 -2 0 34t h St re et Lo ngIsl andCi ty , NY11101 TEL: 1 80 0 76ST EAM FAX: 7184723256 9410S. LaCienegaBlvd. Ingle woodCA9030 1 TEL: 1 80072 STEAM FAX: 3102162944 SAFETY AN D OPERATINGINFORMAT ION • Setth e steambath ingte mperatureacc ordingtopersonal pr eference,howev er it is high ly recommended tobeg in ste ambathingat a lowtemperaturesetting togaugecomfort and safetylev els . Set th e durati onat 10 minutesmax . Togaugecomfortand sa fetylev el s. Th is wil l allowthesteam generatorto heat upand beg in producing steam. • Donotins tal l orus e any eTEMPO/PL US ® , eTEMPO ® , eTEMPO/START ® , eTEMPO/ RE MOTE ® or STE AMGENIE ™ con trols wi th outreadi ng and understandingthe Mr .SteamsteamgeneratorIn stal lationand OperationManual (part numbe r 101289Revisionnumber10.0/08orhigh er).Fa il uretorea d andunders ta nd th eseinstr uctionsmayre sul t in an in operati veorhazar dousinstal la ti on. • A peel and stic k warnin g is providedwiththeMr .S teamsteamge nerator In stall ati onan d OperationManual. Mr .Steamstrongly re commendsthatthis warning be rea d an d postedin a conspicuouslocation near thesteam room. • In stall an d us e th e eTEMPOoreTEMPO /PLUS controls ac cordi ngtoinstructions. Fa ilur e toin stal l an d us e ac cording toin structionswil l resul t in an inoperativ e contr ol orhazard ousoverh eating orin adequate heatingof thesteamroom. • A Steam Ge ni e us edin closeproximitytomultiple generators, may inadvertently turnth emon . Pl ease re adth e pa rag ra phonpairingin this manualif morethan on e Steam Gen ie is us edin closeproximity. __________ _____ __ _____ _____ _____ _____ _____ _____ _____ _____ _____________ • En sure th e steam roomdooris clos edwhe n usinga SteamGenie.Leavingthe steamroomdooropenduring steamgen eratoroperationmayresult in property damage. • Donotroutean y eTEMPO/PL US , eTEMPO,eTEMPO/STARTor STEAM GENIE contr ol wiri ng insid e conduitwithpower li nesorclos e tohotwater orsteam pi pi ng.Doing so mayresul t in an in opera tiveorhazardousinstal lation. • Donotalterormodify any eTEMPO/ PL US, eTEMPO,eTEMPO/STARTor eTEMPO/REMOTEor STEAM GENIE controls. Doingso may resul t in aninopera- ti veorhazardousin stall ati on . __________ _____ __ _____ _____ _____ _____ _____ _____ _____ _____ ______________ IMP ORT ANT: • Donotoperatean y eTEMPO /PL US, eTEMPO,eTEMPO/START,eTEMPO /REMOTE or STEAM GENIE con trolwithan yth in g other than a Mr. Steam eTEMPO compatible steam gen era tor.Mr .S teamresidential ste amge ne ra tors withseria l numberslowerth an 90 0, 000 orany other br andof steamgeneratorare not tobeoperatedwitheTEMPOcontr ols . Doing somayresul t in an inoperati ve installation . • Th is documen t conta in s important safety, operationandmaintenanceinforma- ti on . Leav e th is doc ument withth e homeowner.Donotdisca rd thisdoc ument. • Di scontinueus e of th e steam gen eratororcontrol if thesteam generatoris damagedorother wise notfunctioning pr operly. WARNING ! CAUTION ! mr . steam ® SteamGenie ™ Instal lat ionandOperationIn st ructions ________ ___ ___ _______________________________________________ ______ _________________________________________ 2 STE AM GEN IE IN TERFACEMODULE INST ALLA TIO N • Connectth e STEAMGENIEINTERFACE MODUL E tothegenerator by pl uggingin th e pr ov ided5footcable to theSTEAMGE NIE IN TERFACE MODULE an d th e SteamGenie connectorontheside of thegeneratoras shown. • Mount theSTE AMGENIE IN TERFACE MODUL E in a dr y, indoor location. Formaximumra nge, th e SteamGenieInterfaceModule sh ou ld bemountedas hig h as pr acticalandawayfrommetal thatcouldeffecttheradiosignal.Securi ngit toa ne arbywood st udis id ea l. Th e antennash ouldbe pointi ngupwards. • Wi ththegeneratorpowered, th e red li gh t (steamof f) orgreenlight(steamon)shouldcomeonwhenpluggedin. PresstheTOGGLESTEAMbuttontoconfirm proper connection. • Pressth e ON/OFFbuttonan d confi rmthat th e SteamGenie lig htsmatchthestateof thesteamge ne rator. Redfor STEAM OF F (eTempocontr ol is of f) andgreenforSTEAM ON(eTempocontrolis on). • TheyellowRFacti vitylightontheSTEAMGENIE IN TERFACE MODULE should flasheachtime thebutton onth e St eam GenieFOBis pr essed. • Testthera ngeof th e SteamGeni e FOB. It maybenecessary to cha ng e th e loc at ionof theSteamGen ie Interface Module to improveth e ran ge.ContactMr. Steamte ch nicalserviceforan op tional 60 footcable,par t number 103 97 8- 60. STE AM GEN IE OPERATION: •Whe n theSteamGenie FOBlig ht…
Text truncated - open the document above for the full version.
55 44 33 22 11 D D C C B B A A 914 MHzTransmitter914 MHzReceiver FSKModulator FSKDemodulator MCU 2400bps GPIO 914 MHz RF Radio Block Diagram for Steam Genie - Innotech Systems Inc A 1 1 Wednesday, June 23, 2010 TitleSize Document Number Rev Date: Sheet of 26 MHzY1
Date: February 25, 2010 To: Federal Communications Commission Authorization and Evaluation Division From: William J Brown Subject: Agent Authorization for certification of FCC ID: KSK-104059. Innotech Systems Inc hereby appoints Donald Lerner of Retlif Testing Laboratories to act as our agent in the matter of FCC filings for the certification of FCC ID: KSK-104059. Innotech Systems Inc further attests that no party to the application is subject to denial of federal benefits pursuant to section 5301 of the Anti-Drug Abuse act of 1988, 21 USA 853(a). Sincerely, William J Brown VP of Engineering
Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: KSK-104059 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Operational Description Parts List FIM schematic FIM operational description FIM parts list The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, William J Brown VP of Engineering
Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 1 of 1 External Setup, Front View External Setup, Back View
Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 1 of 1 Antenna Permanently Connected to the EUT
FCC ID: KSK-104059 Mr.Steam: Steam Genie This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Sticker to be attached to bottom of FIM DATE CODE Mr. Steam uses the following convention for date coding their products. A month code as follows.. January O February P March Q April R May S June T July U August V September W October X November Y December Z Followed by the year as 2 digits. In other words May 2010 would be S10. If we have 2 shipments in May, then we should add an A, B suffix.
Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 1 of 2 Internal Setup, Front View Internal Setup, Back View Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 2 of 2 Internal Setup, Back View
Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 1 of 26 Technical Information APPLICANT MANUFACTURER Name: Innotech Systems, Inc. Name: Innotech Systems, Inc. Address: 320 Main St. Address: 320 Main St City, State, Zip: Port Jefferson NY 11777 City, State, Zip: Port Jefferson NY 11777 Date of Report: June 30, 2010 TEST SPECIFICATION: FCC Rules and Regulations Part 15, Subpart C, Section 15.249 TEST PROCEDURE: ANSI C63.4:2003 TEST SAMPLE DESCRIPTION Test Sample: FOB Interface Module (FIM) Brandname(s): Mr. Steam Model(s): Not Applicable FCC ID: KSK-104059 Type: Frequency Modulated Transceiver Power Requirements: 5 VDC derived from controller circuit board Frequency Of Operation: 914.0 MHz Applicable Rule Section: Part 15, Subpart C, Section 15.249 TESTS PERFORMED FCC Paragraph Test Method Testing Date(s) Transmitter 15.207(a) Conducted Emissions January 15, 2010 15.249(d)/15.209 Radiated Emissions, Spurious Case January 19, 2010 15.249(a) Radiated Emissions, Fundamental and Harmonics January 14, 2010 15.249(a) Occupied Bandwidth January 19, 2010 Receiver 15.107(a) Conducted Emissions January 15, 2010 15.109(a) Radiated Emissions January 19, 2010 Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 2 of 26 TEST RESULTS Transmitter: 15.203: The intentional radiator is designed to ensure that no antenna other than that furnished by the applicant can be used with the device. 15.207 (a): The radio frequency voltage that was conducted back on to the AC power line on any frequency/frequencies within the bandwidth of 150 kHz to 30 MHz did not exceed Class B limits as specified in CISPR 22. 15.249 (a): The unit operates in 902 MHz to 928 MHz band. The field strength of the fundamental did not exceed 50 mV/M average. The field strength of the harmonics did not exceed 500 μV/M averages. 15.249 (b): Field strength readings were taken at 3 meters unless otherwise noted. 15.249 (c): Emissions radiated outside the specified frequency band were attenuated in accordance with the general radiated emissions limits of 5.209. 15.249 (d): The peak field strength of any emission did not exceed the maximum permitted average field strength by more than 20 dB. Receiver: 15.107 (a): The radio frequency voltage that was conducted back on to the AC power line on any frequency/frequencies within the bandwidth of 150 kHz to 30 MHz did not exceed Class B limits as specified in CISPR 22. 15.109(a): The field strength of spurious radiated emissions did not exceed Class B limits specified in paragraph 15.109(a). Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 3 of 26 SPECTRUM ANALYZER DESENSITIZATION CONSIDERATIONS GENERAL NOTES 1. The AC input to the plug in transformer was varied from 85% to 115% of the rated input. Field strength measurements were taken with the AC input adjusted to produce maximum emissions. 2. The frequency range was scanned from 30 MHz to 10 GHz. All emissions not reported were more than 20 dB over the specified limit. 3. The Receiver was tested per “ANSI STANDARD C63.4-2003 12.1.1.2” 4. The unit operates at 914.0 MHz 5. The device was tested with the following components: • 120 VAC, 60 Hz to 24 VAC plug in transformer, model number: AC2410 (DV-2412A) • Controller circuit board, manufactured by Innotech, Part number: 103975, serial number: 080850101B 6. The device operates on 5 VDC derived from the controller circuit board 7. The controller circuit board operates on 24 VAC derived from the 120 VAC, 60 Hz to 24 VAC plug in transformer. Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 5 of 26 Equipment List Conducted Emissions EN Type Manufacturer Description Model No. Cal Date Due Date 078 LISN Solar Electronics 10 kHz - 30 MHz 8028-50-TS24BNC 5/29/2009 5/29/2010 079 LISN Solar Electronics 10 kHz - 30 MHz 8028-50-TS24BNC 5/27/2008 5/27/2010 1377 10 dB Atten. / 20W Narda DC - 11 GHz 768-10 8/4/2009 8/4/2010 520H Digital Multimeter Wavetek N/A DM25XT 7/6/2009 7/6/2010 712 EMI Test Receiver Rohde & Schwarz 20 Hz - 26.5 GHz ESIB26 3/19/2009 3/19/2010 Fundamental Harmonics and Occupied Bandwidth EN Type Manufacturer Description Model No. Cal Date Due Date 067 Open Area Test Site Retlif 3/10 Meter RNY 6/1/2009 6/1/2010 1232 Preamplifier Agilent 1 - 26.5GHz 8449B 3/17/2009 3/17/2010 128 Double Ridged Guide Electro-Mechanics 1 GHz - 18 GHz 3105 2/23/2009 2/23/2010 133 Broadband Pre-Amplifier Electro-Metrics 10 kHz - 1 GHz, 26dB BPA-1000 5/6/2009 5/6/2010 141 Spectrum Analyzer Hewlett Packard 100 Hz - 40 GHz 8566B 5/5/2009 5/5/2010 141B Quasi-Peak Adaptor Hewlett Packard 100 Hz - 1 GHz 85650A 5/5/2009 5/5/2010 206B 6.0 dB Attenuator Texscan 0 - 1.0 GHz FP-50 - 6 dB 5/6/2009 5/6/2010 512 Graphics Plotter Hewlett Packard N/A 7470A 10/1/2009 10/1/2010 523 Biconilog Electro-Mechanics 26 - 2000 MHz 3142B 10/13/2009 10/13/2010 Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 6 of 26 FCC Part 15, Subpart C, Section 15.207(a), Conducted Emissions, Power Leads, 150 kHz to 30 MHz Test Data Transmit Mode RETLIF Testing Laboratories, Job Number R-13277-3 FCC Part 15, Conducted Emissions, 150 KHz to 30 MHz. Customer: Innotech Systems, Inc. Test Sample: FOB Interface Module (FIM) FCC ID Number: KSK-104059 Test Specification: FCC Part 15,Subpart C, Radio Frequency Devices 15.207(a) Mode of Operation: Continuously transmitting a 914.0 MHz signal Technician / Date: N. Smith / January 15, 2010 Lead Tested: 115 VAC,60 Hz hot input to plug in transformer. Detector / Note: Peak / Peak emissions pass the quasi-peak Limit. Average detector required. 0 1020304050607080 Level [dBμV] 150k 300k 500k 1M 2M 3M 5M 7M 10M 30M Frequency [Hz] Page 1 of 4 RETLIF Testing Laboratories, Job Number R-13277-3 FCC Part 15, Conducted Emissions, 150 KHz to 30 MHz. Customer: Innotech Systems, Inc. Test S…
Text truncated - open the document above for the full version.
Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 1 of 6 Radiated Emissions, Test Setup, Front View Radiated Emissions, Rear View, X-Axis Setup Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 2 of 6 Radiated Emissions, Rear View, Y-Axis Setup Radiated Emissions, Rear View, Z-Axis Setup Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 3 of 6 Radiated Emissions, Biconilog Antenna, Vertical Polarity, Test Distance Radiated Emissions, Biconilog Antenna, Horizontal Polarity, Test Distance Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 4 of 6 Radiated Emissions, Double Ridged Guide Antenna, Vertical Polarity, Test Distance Radiated Emissions, Double Ridged Guide Antenna, Horizontal Polarity, Test Distance Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 5 of 6 Conducted Emissions, Test Setup Conducted Emissions, Cable Layout Retlif Testing Laboratories, Test Report R-13277-3, Innotech Systems, Inc., FCC ID: KSK-104059 Page 6 of 6 Conducted Emissions, Test Setup, Measurement Location, 115 VAC, 60 Hz Hot into Steam Controller PC Board Conducted Emissions, Test Setup, Measurement Location, 115 VAC, 60 Hz Neutral into Steam Controller PC Board
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 914 MHz - 914 MHz | - |

914MHz KEYFOB
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified