Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Aptiv Services Deutschland GmbH Postanschrift: D-42367 Wuppertal Hausanschrift: Am Technologiepark 1 D-42119 Wuppertal Telefon: Telefax: Internet: (02 02) 2 91 – 0 (02 02) 2 91 – 2777 www.aptiv.com Sitz der Gesellschaft: Wuppertal Registergericht: AG Wuppertal, HRB 21453 Geschäftsführung: Matthias Laumann (Sprecher) Johannes Bornmüller Darren Byrka Eoin Muldowney Aufsichtsrat: Michael Gassen (Vorsitzender) Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Compliance Statement in Car Manual / FCC ID: LTQ2R5TR Dear Sirs, Our products with the above FCC ID code are field disturbance sensors. The product will be installed in cars by our customer Nissan before they will be placed into the market. Hereby we assure that the following caution statement as per CFR 47, Part 15, § 15.21 will be included in the owner's manual of the cars: The title "CAUTION TO USERS" or "FCC Warning:" "NOTE:" or relevant title and "Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment." In addition our client also assures that the following statement will be included in the manual as per CFR 47, Part 15, § 15.19 (a) (3). This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. Yours Sincerely Ljiljana Trivic Certification Responsible E-Mail: [email protected] Phone +49 2261 971 415 Date: 25 th July 2022
Aptiv Services Deutschland GmbH Postanschrift: D-42367 Wuppertal Hausanschrift: Am Technologiepark 1 D-42119 Wuppertal Telefon: Telefax: Internet: (02 02) 2 91 – 0 (02 02) 2 91 – 2777 www.aptiv.com Sitz der Gesellschaft: Wuppertal Registergericht: AG Wuppertal, HRB 21453 Geschäftsführung: Matthias Laumann (Sprecher) Johannes Bornmüller Darren Byrka Eoin Muldowney Aufsichtsrat: Michael Gassen (Vorsitzender) Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request FCC ID: LTQ2R5TR Dear Sirs, Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Aptiv Services Deutschland GmbH hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation Internal Photos, ( Please see separate letter ) Aptiv Services Deutschland GmbH also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of period of 180 days: (Note: for the X number of days, you can list up to 180 days, but should not go past the date you start product marketing/sale) External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours Sincerely Ljiljana Trivic Certification Responsible E-Mail: [email protected] Phone +49 2261 971 415 Date: 19 th July 2022
Aptiv Services Deutschland GmbH Postanschrift: D-42367 Wuppertal Hausanschrift: Am Technologiepark 1 D-42119 Wuppertal Telefon: Telefax: Internet: (02 02) 2 91 – 0 (02 02) 2 91 – 2777 www.aptiv.com Sitz der Gesellschaft: Wuppertal Registergericht: AG Wuppertal, HRB 21453 Geschäftsführung: Matthias Laumann (Sprecher) Johannes Bornmüller Darren Byrka Eoin Muldowney Aufsichtsrat: Michael Gassen (Vorsitzender) Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request of internal photos Request for long term confidentiality of the Internal photos for our short range radar sensor with FCC ID: LTQ2R5TR Dear Sirs, We Aptiv Services Deutschland GmbH would like to kindly ask you for a long term confidentiality of the internal photos from our short range radar sensor due to following reasons: Our radar sensors are fully laser welded and cannot be opened and accessed by public persons. Non of the public manuals include internal photos. In case of failures the sensors can only be maintained/replaced by professional designated technicians trained and working at appointed OEM car shops. LTQ2R5TR sensor is using a special Aptiv developed technology which we would like to protect from competitors. Please see also the enclosed NDA Yours Sincerely Ljiljana Trivic Certification Responsible E-Mail: [email protected] Phone +49 2261 971 415 Date: 25 th July 2022
2R5TR FCC ID: LTQ2R5TR APTIV IC ID: 3659A-2R5TR 2R5TR FCC ID: LTQ2R5TR APTIV IC ID: 3659A-2R5TR 2R5TR FCC ID: LTQ2R5TR APTIV IC ID: 3659A-2R5TR
Germany · IBL-Lab GmbH · Heinrich-Hertz-Allee 7-10 · 66386 Sankt Ingbert · Tel: +49 6894 38938-0 · Fax: +49 6894 38938-99 1 / 19 Company Register: 105151, Amtsgericht Saarbrücken URL: www.ib-lenhardt.de · E-Mail: [email protected] Assessment Report Test report no.: 22037042-26419-2 Date of issue: 2022-09-29 Test result: The test item - passed - and complies with the listed standards. Applicant Aptiv Services Deutschland GmbH Manufacturer Aptiv Services Deutschland GmbH Test Item 2R5TR MPE Assessment according to: FCC 47 CFR Part 15 Radio frequency devices Parts 1.1307, 1.1310, 2.1091, 2.1093 Canada RSS-102 Issue 5 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Tested by (name, function, signature) Andreas Bender Deputy Managing Director Approved by (name, function, signature) Karsten Geraldy Lab Manager {{$tested}} {{$approved}} TR no.: 22037042-26419-2 2022-09-29 2 / 19 IBL-Lab GmbH Applicant and Test item details Applicant Aptiv Services Deutschland GmbH Am Technologiepark 1 42119, Wuppertal, Germany Phone: +49 2261 971 415 Manufacturer Aptiv Services Deutschland GmbH Am Technologiepark 1 42119, Wuppertal, Germany Test item description Short Range Radar (SRR5) Model/Type reference 2R5TR Standard specific information Frequency 76.0 GHz to 77.0 GHz Antenna integrated patch antenna Power supply 9.0 to 16.0 V DC Temperature range -40 °C to +85 °C FCC ID LTQ2R5TR Company number: 3659A IC (ISED CERTIFICATION NUMBER) 3659A-2R5TR HMN (HOST MARKETING NAME) APTIV PMN (PRODUCT MARKETING NAME) 2R5TR HVIN (HARDWARE VERSION IDENTIFICATION NO.) E1 FVIN (FIRMWARE VERSION IDENTIFICATION NO.) 0.0.4 {{#tested=Sig_es_:signer1:signature:align(center):dimension(width=35mm, height=15mm)}} {{#approved=Sig_es_:signer2:signature:align(center):dimension(width=35mm, height=15mm)}} Disclaimer and Notes The content of this report relates to the mentioned test sample(s) only. Without a written permit of IBL-Lab GmbH, this test report shall not be reproduced, except in full. The last valid version is available at TAMSys . Copyright : All rights reserved by IBL-Lab GmbH Within this test report, a ☒ point / ☐ comma is used as a decimal separator. If otherwise, a detailed note is added adjected to its use. IBL-Lab GmbH does not take samples. The samples used for testing are provided by the applicant. Decision rule: See parent Test Report IBL-Lab GmbH. Decision rule based on simple acceptance without guard bands, binary statement, based on mutually agreed uncertainty tolerances with expansion factor k=2. TR no.: 22037042-26419-2 2022-09-29 3 / 19 IBL-Lab GmbH 1 TABLE OF CONTENTS 1 TABLE OF CONTENTS ......................................................................................................................... 3 2 GENERAL INFORMATION ................................................................................................................... 4 2.1 Administrative details .......................................................................................................................... 4 2.2 Possible test case verdicts ................................................................................................................. 4 2.3 Observations ....................................................................................................................................... 5 2.4 Opinions and Interpretations .............................................................................................................. 5 2.5 Document History ............................................................................................................................... 5 3 ENVIRONMENTAL & TEST CONDITIONS........................................................................................... 6 3.1 Environmental conditions of test lab ................................................................................................... 6 4 TEST STANDARDS AND REFERENCES ............................................................................................ 6 5 Device Data ........................................................................................................................................... 7 6 MPE Assessment Requirements ........................................................................................................... 8 6.1 FCC 47 CFR ....................................................................................................................................... 8 6.1.1 FCC 47 CFR Part 1.1307 (b)(3) - Determine that they qualify for an exemption ................................ 8 6.1.2 FCC 47 CFR Part 1.1310 Radiofrequency radiation exposure limits. ................................................. 8 6.1.3 FCC 47 CFR Part 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. ............... 9 6.1.4 KDB 447498 D01 General RF Exposure Guidance v06, 4.3.2. Simultaneous transmission SAR test exclusion considerations .................................................................................................................................... 9 6.2 ISED RSS-102 Issue 5 - Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) ........................................................................................................................ 10 6.2.1 ISED MPE limits ................................................................................................................................. 10 6.2.2 RSS-102 Section 2.5 - Exemption Limits for Routine Evaluation ...................................................... 11 6.2.3 RSS-102 Section 2.5.2 - Exemption Limits for Routine Evaluation – RF Exposure Evaluation ........ 11 6.2.4 RSS-102 Section 3.1.2 SAR Measurement of Devices Containing Multiple Transmitters ................ 11 7 MPE Calculation Method ...................................................................................................…
Text truncated - open the document above for the full version.
Company: IBL-Lab GmbH · Heinrich-Hertz-Allee 7 · 66386 St. Ingbert · Germany · Tel: +49 6894 38938-0 · Fax: +49 6894 38938-99 1 / 71 Company Register: 105151, Amtsgericht Saarbrücken URL: www.ib-lenhardt.de · E-Mail: [email protected] Test Report Test report no.: 22037042-26423-1 Date of issue: 2022-10-26 Test result: The test item - passed - and complies with below listed standards. Applicant Aptiv Services Deutschland GmbH Manufacturer Aptiv Services Deutschland GmbH Test Item 2R5TR RF-Spectrum Testing according to: FCC 47 CFR Part 95 Personal radio services, Subpart M – The 76-81 GHz Band Radar Service Tested by (name, function, signature) Karsten Geraldy Lab Manager RF signature Approved by (name, function, signature) Andreas Bender Deputy Managing Director signature TR no.: 22037042-26423-1 2022-10-26 2 / 71 IBL-Lab GmbH Applicant and Test item details Applicant Aptiv Services Deutschland GmbH Am Technologiepark 1 42119, Wuppertal, Germany Phone: +49 2261 971 415 Manufacturer Aptiv Services Deutschland GmbH Am Technologiepark 1 42119, Wuppertal, Germany Test item description Short Range Radar (SRR5) Model/Type reference 2R5TR FCC ID LTQ2R5TR Frequency 76.0 GHz to 77.0 GHz Antenna integrated patch antenna Power supply 9.0 to 16.0 V DC Temperature range -40 °C to +85 °C Disclaimer and Notes The content of this test report relates to the mentioned test sample(s) only. Without a written permit of IBL-Lab GmbH, this test report shall not be reproduced, except in full. The last valid version is available at TAMSys . Copyright ©: All rights reserved by IBL-Lab GmbH Within this test report, a ☒ point / ☐ comma is used as a decimal separator. If otherwise, a detailed note is added adjected to its use. IBL-Lab GmbH does not take test samples. The samples used for testing are provided by the applicant. Decision rule: Decision rule based on simple acceptance without guard bands, binary statement, based on mutually agreed uncertainty tolerances with expansion factor k=2 according to ILAC-G8:09/2019 TR no.: 22037042-26423-1 2022-10-26 3 / 71 IBL-Lab GmbH 1 TABLE OF CONTENTS 1 TABLE OF CONTENTS ........................................................................................................................... 3 2 GENERAL INFORMATION ..................................................................................................................... 4 2.1 Administrative details .......................................................................................................................... 4 2.2 Possible test case verdicts ................................................................................................................. 4 2.3 Observations ....................................................................................................................................... 5 2.4 Opinions and interpretations ............................................................................................................... 5 2.5 Revision history .................................................................................................................................. 5 2.6 Further documents .............................................................................................................................. 5 3 ENVIRONMENTAL & TEST CONDITIONS ............................................................................................ 6 3.1 Environmental conditions ................................................................................................................... 6 3.2 Normal and extreme test conditions ................................................................................................... 6 4 TEST STANDARDS AND REFERENCES .............................................................................................. 6 5 EQUIPMENT UNDER TEST (EUT) ......................................................................................................... 7 5.1 Product description ............................................................................................................................. 7 5.2 Description of test item ....................................................................................................................... 7 5.3 Technical data of test item .................................................................................................................. 7 5.4 Additional information ......................................................................................................................... 7 5.5 Operating conditions ........................................................................................................................... 8 5.6 Antenna characteristics ...................................................................................................................... 8 6 SUMMARY OF TEST RESULTS ............................................................................................................. 9 7 TEST RESULTS .................................................................................................................................... 10 7.1 RF power output (§2.1046 & §95.3367) ........................................................................................... 10 7.2 Modulation characteristics (§2.1047 & KDB 653005 D01 76-81 GHz Radars) ................................ 22 7.3 Occupied bandwidth (§2.1049 & §95.3379) ..................................................................................... 23 7.4 Field strength of spurious radiation (§2.1053 & §95.3379) .............................................................. 30 7.5 Frequency stability (§2.1055 & §95.3379(b)) ................................................................................... 47 8 Test Setup Description .......................................................................................................................... 60 8.1 Semi Anechoic Chamber with…
Text truncated - open the document above for the full version.
TR-Annex no.: 22037042-26423-0 2022-09-29 8 / 12 IBL-Lab GmbH Annex 3 Test Setup Photographs Photo No. 12: Photo No. 13: TR-Annex no.: 22037042-26423-0 2022-09-29 9 / 12 IBL-Lab GmbH Photo No. 14: Photo No. 15: TR-Annex no.: 22037042-26423-0 2022-09-29 10 / 12 IBL-Lab GmbH Photo No. 16: Photo No. 17: TR-Annex no.: 22037042-26423-0 2022-09-29 11 / 12 IBL-Lab GmbH Photo No. 18: Photo No. 19: TR-Annex no.: 22037042-26423-0 2022-09-29 12 / 12 IBL-Lab GmbH End of Test Report Annex
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 95M | 76.05 GHz - 76.97 GHz | 105.00 mW |
SRR6+
Equipment Class
VRD - Part 95 Vehicular Radar SystemsRadar Sensor
Equipment Class
VRD - Part 95 Vehicular Radar SystemsInfotainment Head Unit
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBsRadar Sensor
Equipment Class
VRD - Part 95 Vehicular Radar Systems
Display Head Unit
Equipment Class
DTS - Digital Transmission System