FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cochran Consulting Inc/
  3. LYP744556-04

LYP744556-04Scuba Diving Monitor TX

Cochran Consulting Inc
Scuba Diving Monitor TX - FCC ID LYP744556-04 - Cochran Consulting Inc
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Oct 14, 1999
Application Purpose
Original Equipment
Date of Application
Sep 13, 1999
Equipment Note
Scuba Diving Monitor TX
Frequency Range
0.24600000 - 0.24600000
Company
Cochran Consulting Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

โ†—
โ†—

Cover Letter(s)

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Operational Description

โ†—

Schematics

โ†—

Test Report

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GEMINI User Manual Version 001i 1 DRAFT GEMINI USER MANUAL English Language โ€“ Imperial Units Version 001 USER INFORMATION For your information, please fill in the following information SERIAL NUMBER OF THE TANK UNIT: ____________________________ SERIAL NUMBER OF THE WRIST UNIT: ____________________________ DATE OF PURCHASE: __________________________________________ PLACE OF PURCHASE: _________________________________________ ADDRESS: ____________________________________________________ CITY: _________________________________________________________ STATE: _______________________________ ZIP CODE: ____________ PHONE NUMBER: ______________________________________________ GEMINI User Manual Version 001i 2 TABLE OF CONTENTS Table of Contents 2 Figures Index 4 Limited Warranty and Liability Statement 5 Product Certifications 7 Patent Information 8 Introduction 9 Overview 9 User & Environmental Adaptation 9 Altitude Acclimatization 9 Water Temperature Compensation10 Microbubble Compensation10 User Conservatism11 Previous Dive Profile11 Salt/Fresh Water Compensation11 Workload Compensation11 Theory of Operation12 Nitrox-specific Functions12 Equivalent Air Depth12 Central Nervous System (CNS) Oxygen Toxicity13 Pulmonary, Whole Body (OTU) Oxygen Toxicity14 Installation15 Tank Unit Touch Contacts15 Activation17 Operating Modes18 Self-Diagnostic Mode18 Surface Mode19 Predive Prediction Mode22 CNS/OUT Toxicity Display24 O 2 Mix Display25 Battery/Altitude Display26 Logbook Mode27 Subsurface Mode29 Emergency Decompression Mode31 Field Programming Mode36 Field Programming โ€“ NITROX Disabled36 Field Programming โ€“ NITROX Enabled39 Explanations41 Altitude Diving41 Ascent Rate Ascent Rate Bar Graph42 BATT43 Bottom43 41 TABLE OF CONTENTS (CONTINUED) GEMINI User Manual Version 001i 3 BP44 Ceiling44 Depth45 Dive45 Max Depth46 Metric46 Mission OTU Clock46 Remaining Time Air46 Remaining Time NDC47 Remaining Time DEC47 Surface Time47 Tank47 Temp48 Time-To-Fly48 AUDIBLE & VISUAL ALARMS49 User Defined Maximum Depth49 ยฝ Tank Pressure Alarm49 Low On Air49 Ceiling Violation50 Breathing Parameter50 Ascent Rate Alarm50 Low Battery Voltage51 Two-Minute Warning51 100-Foot Decompression Stop Warning51 Entering Decompression Mode51 Oxygen Tolerance Units (OTU) Warning51 Central Nervous System (CNS) Oxygen Toxicity51 Maximum PO 2 Alarm52 Data Storage Types & Capacity53 User Configurable Options53 Questions & Answers57 Care and Maintenance58 Rinsing and Cleaning58 High-pressure Transducer Care59 Battery Type and replacement59 Battery Care60 Technical Specifications61 Replacement Parts62 Accessories62 Analyst ยฎ Personal Computer Interface62 GEMINI User Manual Version 001i 4 FIGURES - INDEX FigurePage Number 1Self-Diagnostic Mode18 2Surface Mode, Primary Screen, With Nitrogen19 2aSurface Mode, Primary Screen, No Nitrogen20 3Surface Mode, Alternate Screen, With Nitrogen21 3aSurface Mode, Alternate Screen, No Nitrogen21 4PreDive Prediction Mode, Primary Screen22 5CNS/OTU Toxicity Display24 6Oxygen Mix Percentage Display25 7Battery/Altitude Display26 8Subsurface Mode, Normal Dive, Primary Screen29 9Subsurface Mode, Normal Dive, Alternate Screen30 10 Subsurface Mode, Emergency Decompression, 20 Foot Ceiling, Primary Display33 10aSubsurface Mode, Emergency Decompression, 110-Foot Ceiling, Primary Screen34 11 Subsurface Mode, Emergency Decompression35 13Logbook Mode, Primary Screen27 14Logbook Mode, Alternate Screen28 15 Oxygen Toxicity Warning Screen52 17Field Programming Mode (Setting Oxygen %)39 18Field Programming Mode (Setting Cylinder Size)36 19Field Programming Mode (Setting Conservatism)38 20Field Programming Mode (Setting Depth Alarm)39 21Ascent Rate Bar Graph43 22Tank Unit Touch Contacts16 GEMINI User Manual Version 001i 5 Limited Warranty To the original purchaser (โ€œOWNERโ€) only, Cochran Undersea Technology, a division of Cochran Consulting, Inc. (โ€œCOCHRANโ€), represents this Product to be free of defects in both materials and workmanship under normal SCUBA use for 24 months from the date of shipment from COCHRAN to the Authorized Dealer or Distributor. For purposes of establishing warranty eligibility, this date may be noted on the original product box, or can be determined by contacting COCHRAN. Any defective Product, unless cause is specifically excluded in the โ€œWarranty Conditions and Limitationโ€ section below will at the sole discretion of COCHRAN, be repaired, replaced, or replaced with a new or refurbished unit of comparable or better function and/or condition. COCHRAN is not responsible for any incidental or secondary damages as a result of Product malfunction WARRANTY LIMITATIONS AND EXCLUSIONS Product must have been obtained from a COCHRAN Authorized Dealer. Contact COCHRAN for verification of dealer status. This Warranty is not transferable. The warranty registration card must be sent to COCHRAN within 15 days of the purchase in order to validate Limited Warranty Failure to provide proper care for this Product will render this Limited Warranty null and void. Damages or malfunction resulting from accidental or deliberate abuse, tampering, battery leakage, exceeding maximum intended operating depth or other parameters, extreme heat or cold, or other conditions that COCHRAN deem to be outside the intended scope of this Limited Warranty are not covered. Plastics, o-rings, batteries, battery life and flooded battery compartments are NOT covered by this Limited Warranty. OWNER is responsible for shipping this Product to COCHRAN for service, and paying all associated costs, including shipping, insurance, and import duties. OWNER may take Product to an Authorized Dealer to arrange service under terms of this Limited Warranty. COCHRAN will return Product to OWNER or Dealer via a method and carrier of its choosing. Costs for requested expedited return shipping will be the responsibility of OWNER. Product returned for service under terms of this Limited Warranty must be accompanied by a photocopy of the original sales receโ€ฆ

Text truncated - open the document above for the full version.

Users Manual

GEMINI Nitrox User Manual Version 001 1 DRAFT GEMINI Nitrox USER MANUAL English Language โ€“ Imperial Units Version 001 USER INFORMATION For your information, please fill in the following information SERIAL NUMBER OF THE TANK UNIT: ____________________________ SERIAL NUMBER OF THE WRIST UNIT: ____________________________ DATE OF PURCHASE: __________________________________________ PLACE OF PURCHASE: _________________________________________ ADDRESS: ____________________________________________________ CITY: _________________________________________________________ STATE: _______________________________ ZIP CODE: ____________ PHONE NUMBER: ______________________________________________ GEMINI Nitrox User Manual Version 001 2 TABLE OF CONTENTS Page Number Figures Index 5 Limited Warranty and Liability Statement 8 Product Certifications10 Patent Information11 Product Introduction12 Overview12 Constant PO 2 & FO 2 Modes12 User & Environmental Adaptation13 Altitude Acclimatization13 Water Temperature Compensation14 Microbubble Compensation15 User Conservatism15 Previous Dive Profile15 Salt/Fresh Water Compensation15 Workload Compensation15 Theory of Operation16 Enriched Air Nitrox, Three Blend Capability17 Equivalent Air Depth18 Central Nervous System (CNS) Oxygen Toxicity19 Pulmonary, Whole Body (OTU) Oxygen Toxicity20 Installation21 Tank Unit Touch Contacts22 Activation23 Operating Modes24 Self-Diagnostic Mode24 FO 2 Operating Modes25 FO 2 Surface Mode25 Predive Prediction Mode27 FO 2 Logbook Mode29 FO 2 Subsurface Mode33 Emergency Decompression Mode37 FO 2 Emergency Decompression Mode39 FO 2 CNS/OUT Toxicity Display41 Primary Battery Display48 Secondary Battery Display49 Wrist Unit Battery Display49 Altitude Display50 FO 2 Sensor Warning Display51 PO 2 Operating Modes22 PO 2 Surface Mode23 GEMINI Nitrox User Manual Version 001 3 TABLE OF CONTENTS (CONTINUED) PO 2 Logbook Mode28 PO 2 Subsurface Mode33 PO 2 Emergency Decompression Mode38 PO 2 CNS/OUT Toxicity Display43 PO 2 Sensor Warning Display52 Post-Dive Interval Mode Pseudo-Off Mode Wrist Unit Independent Operating Mode22 Surface Mode23 Predive Prediction Mode26 Logbook Mode28 Subsurface Mode33 Emergency Decompression Mode38 CNS/OUT Toxicity Display43 Battery/Altitude Display50 Sensor Warning Display52 Field Programming Mode55 Tank Unit Touch Contacts55 Field Programming โ€“ Tank Unit - Menu for FO 2 Mode56 Field Programming โ€“ Tank Unit - Menu for PO 2 Mode56 Wrist Unit Touch Contacts56 Field Programming โ€“ Wrist Unit - Slave Mode56 Field Programming โ€“ Wrist Unit - Independent Mode Explanations41 Altitude Diving41 Altitude Bar Graph Ascent Rate41 Ascent Rate Bar Graph42 Bottom43 BP44 Primary Battery Bar Graph43 Ceiling44 Depth45 Dive45 Max Depth46 Metric46 Mission OTU Clock46 Remaining Time Air46 Remaining Time NDC47 Remaining Time DEC47 Secondary Battery Bar Graph GEMINI Nitrox User Manual Version 001 4 Surface Time47 Tank47 Temp48 Time-To-Fly48 TABLE OF CONTENTS (CONTINUED) AUDIBLE & VISUAL ALARMS49 User Defined Maximum Depth49 ยฝ Tank Pressure Alarm49 Low On Air49 Ceiling Violation50 Breathing Parameter50 Ascent Rate Alarm50 Low Battery Voltage51 Two-Minute Warning51 100-Foot Decompression Stop Warning51 Entering Decompression Mode51 Oxygen Tolerance Units (OTU) Warning51 Central Nervous System (CNS) Oxygen Toxicity51 Maximum PO 2 Alarm52 Data Storage Types & Capacity53 User Configurable Options53 Questions & Answers57 Care and Maintenance58 Rinsing and Cleaning58 High-pressure Transducer Care59 Battery Type and replacement59 Battery Care60 Technical Specifications61 Replacement Parts62 Accessories62 Analyst ยฎ Personal Computer Interface62 GEMINI Nitrox User Manual Version 001 5 FIGURES Fig #Page Number 1. Self-Diagnostic22 2. Surface โ€“ No Nitrogen - FO 2 Mode - Primary23 2a. Surface โ€“ No Nitrogen - PO 2 Mode - Primary23 3. Surface โ€“ No Nitrogen - FO 2 Mode - Alternate24 3a.Surface โ€“ No Nitrogen - PO 2 Mode - Alternate23 4. Surface โ€“ With Nitrogen - FO 2 Mode - Primary24 4a.Surface โ€“ With Nitrogen - PO 2 Mode - Primary25 5. Surface โ€“ With Nitrogen - FO 2 Mode - Alternate24 5aSurface โ€“ With Nitrogen - PO 2 Mode - Alternate25 6. PreDive Prediction 26 7. Logbook - FO 2 Mode โ€“ Primary โ€“ No Nitrogen Normal Dive โ€“ Beginning29 7aLogbook - PO 2 Mode โ€“ Primary โ€“ No Nitrogen Normal Dive โ€“ Beginning29 8 Logbook โ€“ FO 2 Mode - Alternateโ€“ No Nitrogen Normal Dive โ€“ Beginning29 8aLogbook โ€“ PO 2 Mode - Alternateโ€“ No Nitrogen Normal Dive โ€“ Beginning29 9Logbook โ€“ FO 2 Mode - Primary Normal Dive โ€“ Ending30 9aLogbook โ€“ PO 2 Mode - Primary Normal Dive โ€“ Ending30 10Logbook โ€“ FO 2 Mode - Alternate Normal Dive โ€“ Ending31 10aLogbook โ€“ PO 2 Mode - Alternate Normal Dive โ€“ Ending31 11 Logbook โ€“ FO 2 Mode - Primary Decompression Dive โ€“ Ending31 11aLogbook โ€“ PO 2 Mode - Primary Decompression Dive โ€“ Ending31 12 Logbook โ€“ FO 2 Mode - Alternate Decompression Dive โ€“ Ending32 12aLogbook โ€“ PO 2 Mode - Alternate Decompression Dive โ€“ Ending32 13 Subsurface โ€“ FO 2 Mode - Primary - Showing Blend #1 33 13a Subsurface โ€“ PO 2 Mode - Primary - Showing BP = 035 14 Subsurface โ€“ FO 2 Mode - Alternate - Showing Blend 1 34 14aSubsurface โ€“ FO 2 Mode - Alternate - Showing Blend 2 36 14bSubsurface โ€“ FO 2 Mode - Alternate - Showing Blend 3 37 14cSubsurface โ€“ PO 2 Mode - AlternateXX 15 Emergency Decompression โ€“ FO 2 Mode - Primary40 15a Emergency Decompression โ€“ FO 2 Mode - Primary 120 foot stop41 15bEmergency Decompression โ€“ PO 2 Mode - Primary40 15c Emergency Decompression โ€“ PO 2 Mode - Primary 120 foot stopXX GEMINI Nitrox User Manual Version 001 6 FIGURES (continued) Fig #Page Number 16 Emergency Decompression โ€“ FO 2 Mode - Alternate42 16aEmergency Decompression โ€“ PO 2 Mode - Alternate 42 17 Ascent Bar Graph49 18 Primary Battery Bar Graph50 19 Secondary Battery Bar Graph51 20 Altitude Bar Graph52 21 Wrist Unit Battery Bar Graph51 23 Subsurface - FO 2 Mode - CNS/OTU Toxicity - Primary 44 23a CNS Warning Bar Graph45 23bSubsurface - PO 2 Mode - CNS/OTU Toxicity - Primary 44 24 Subsurface - FOโ€ฆ

Text truncated - open the document above for the full version.

Operational Description

COCHRAN CONSULTING, INC. GEMINI DIVE COMPUTER FCC ID: LYP744556-04 Description of Equipment: Tank Unit โ€“ The battery powered Tank Unit is a combination microprocessor and very low power transmitter that transmits data to a receiver (Wrist Unit) using PCM, 246 kHz magnetic (inductive) transmissions. The Tank Unit transmits data once each second while in an activated mode. The bulk of the Tank Unit circuitry is not powered (OFF) except when the Unit performs computations and transmits data (ON). A 4.9152 MHz oscillator operates only during the ON time. A 32.768 kHz oscillator runs all of the time while batteries are installed. There are three screw heads (Touch Contacts) on the outside of the case that provide RS-232 communications with a P.C. using the optional Analyst package, described below. These same Touch Contacts, a finger, and a coin can be used to manually program configurations and/or cause logbook data to be transmitted to the Wrist Unit for display. There is a short cable with a high-pressure transducer on it that connects to the regulator on the air/gas cylinder to provide pressure data to the microprocessor. Wrist Unit โ€“ The battery operated Wrist Unit is a combination microprocessor and receiver. The Wrist Unit of the standard system displays received data only. The Wrist Unit that comes with the Enhanced (NITROX) system displays additional information, can act as a stand-alone dive computer, and can communicate with a P.C. using the optional Analyst package. The NITROX Wrist Unit is programmed and accessed in the same way as the Tank Unit. A 3.2 MHz oscillator operates only during the Wrist Unitโ€™s ON time. A 32.768 kHz oscillator operates all of the time that batteries are installed. Analyst โ€“ The Analyst is an optional RS-232 cable/software package for the Tank Unit and the NITROX Wrist Unit for interfacing with the serial port of a P.C. The package allows the sport diver to retrieve extensive information about previous dives and to tailor the programming of the GEMINI for the next dive.

Test Report

Master: ktlPT15209 Date: June 3, 1999 KTL Test Report:9L0297RUS Applicant:Cochran Consulting 1758 Firman Drive Richardson, Tx. 75081 Equipment Under Test:Gemini / Gemini Nitrox (E.U.T.) FCC ID:LYP744556-04 In Accordance With:FCC Part 15, Subpart C, Paragraph 15.209 General Limits For Low Power Transmitters Tested By:KTL Dallas Inc. 802 N. Kealy Lewisville, TX 75057-3136 Authorized By: Tom Tidwell, RF Group Manager Date:9/01/99 Total Number of Pages:21 KTL DallasFCC PART 15, SUBPART C PARAGRAPH 15.209 PROJECT NO.: 9L0297RUS EQUIPMENT:Gemini / Gemini Nitrox FCC ID: LYP744556-04 Page 2 of 21 Table Of Contents Section 1. Summary Of Test Results....................................................................... 3 Section 2. General Equipment Specification........................................................... 5 Section 3. Powerline Conducted Emissions............................................................ 9 Section 4. Radiated Emissions................................................................................ 12 Section 5. Occupied Bandwidth.............................................................................. 17 Section 6. Test Equipment List............................................................................... 19 TEST DIAGRAMS ......................................................................................................... A1 KTL DallasFCC PART 15, SUBPART C PARAGRAPH 15.209 PROJECT NO.: 9L0297RUS EQUIPMENT:Gemini / Gemini Nitrox FCC ID: LYP744556-04 Page 3 of 21 Section 1.Summary Of Test Results Manufacturer: Cochran Consulting Model No.: Gemini / Gemini Nitrox Serial No.: None General:All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 15, Subpart C for low power devices. All tests were conducted using measurement procedure ANSI C63.4-1992. Radiated Emissions were made on an open area test site. New SubmissionProduction Unit Class II Permissive ChangePre-Production Unit THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. See โ€œ Summary of Test Dataโ€.

Contact Information

Applicant

Michael Cochran(Owner)
[email protected]9726446284Fax: 9726446286

Technical Contact

Tom TidwellTom N Tidwell
[email protected]972-436-9600

802 N. Kealy ยท Lewisville, Texas ยท United States

Non-Technical Contact

KTL Dallas, Inc.Tom N Tidwell
[email protected]972-436-9600

Test Firm

Nemko Dallas, Inc.Michael Cantwell
@.972-436-9600Fax: 972-436-2667

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.246 MHz - 0.246 MHz-

Other Applications from Cochran Consulting Inc

LYP744556-03

Dive Computer Device

Mar 19, 1996

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
LYP744556-01

Dive Monitor Transmitter w/Serial Port

Dec 14, 1994

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz