FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Skit International Ltd./
  3. N4NRG138RD

N4NRG138RDMotion Sensor Alarm

Skit International Ltd.
Motion Sensor Alarm - FCC ID N4NRG138RD - Skit International Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 27, 1999
Application Purpose
Original Equipment
Date of Application
Jul 27, 1999
Equipment Note
Motion Sensor Alarm
Frequency Range
300.00000000 - 300.00000000
Company
Skit International Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

Cover Letter(s)

β†—

External Photos

β†—
β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—
β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

Skit International Ltd. Application For Certification (FCC ID: N4NRG138RD) Transmitter WO# 9905339 WN/at July 19, 1999 INTERTEK TESTING SERVICES FCC ID: N4NRG138RD i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: N4NRG138RD ii MEASUREMENT/TECHNICAL REPORT Skit International Ltd. - MODEL: CSA 138 Ceiling Strobe Alarm FCC ID: N4NRG138RD July 19, 1999 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-1-96 Edition] provision. Report prepared by:Wilbur Ng Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone: 852-2713-8502 Fax:852-2745-8306 INTERTEK TESTING SERVICES FCC ID: N4NRG138RD iii Table of Contents 1.0 General Description................................................................................................................. 2 1.1 Product Description ................................................................................................................ 2 1.2 Related Submittal(s) Grants .................................................................................................... 2 1.3 Test Methodology ................................................................................................................... 3 1.4 Test Facility ............................................................................................................................ 3 2.0 System Test Configuration...................................................................................................... 5 2.1 Justification............................................................................................................................. 5 2.2 EUT Exercising Software ....................................................................................................... 5 2.3 Special Accessories................................................................................................................. 5 2.4 Equipment Modification ......................................................................................................... 6 2.5 Support Equipment List and Description ................................................................................ 6 3.0 Emission Results....................................................................................................................... 8 3.1 Field Strength Calculation....................................................................................................... 9 3.2 Radiated Emission Configuration Photograph ...................................................................... 11 3.3 Radiated Emission Data ........................................................................................................ 13 3.4 Line Conducted Configuration Photograph (cont’d) ............................................................. 14 3.5 Line Conducted Emission Data .................................................................................................19 4.0 Equipment Photographs........................................................................................................ 15 5.0 Product Labelling................................................................................................................... 17 6.0 Technical Specifications......................................................................................................... 19 7.0 Instruction Manual................................................................................................................ 21 8.0 Miscellaneous Information.................................................................................................... 23 8.1 Measured Bandwidth ............................................................................................................ 24 8.2 Discussion of Pulse Desensitization...................................................................................... 25 8.3 Calculation of Average Factor ..............................................................................................26 8.4 Emissions Test Procedures.................................................................................................... 27 INTERTEK TESTING SERVICES FCC ID: N4NRG138RD iv List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated1.jpg, radiated2.jpg Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoophoto1.jpg to ophoto2.jpg Internal PhotoInternal Photoiphoto1.jpg to iphoto2.jpg Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf INTERTEK TESTING SERVICES FCC ID: N4NRG138RD 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: N4NRG138RD 2 1.0General Description 1.1Product Description The Equipment Under Test (EUT) is a Ceiling Strobe Alarm Trasmitter operating at 300 MHz. The EUT is powered by one 9V battery and 4 x 1.5V "C type" batteries. The EUT is built with a Passive Infrared Sensor to detect motor. The function is activated by an infrared transmitter. Once motion is detected, the strobe light and alarm will be triggered. At the sam…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Arthur Yung(Director)
852-2619-1663

Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilbur Ng
[email protected](852)-2173-8504

2/F., Garment Centre, Β· Kowloon Β· Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilbur Ng
[email protected](852)-2173-8504

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
115C300 MHz - 300 MHz-

Other Applications from Skit International Ltd.

CRR - Superregenerative Receiver - FCC ID N4NRG118RD - Skit International Ltd.
N4NRG118RD

CRR - Superregenerative Receiver

Sep 28, 1999

Equipment Class

CRR - Superregenerative Receiver