Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Nov 19, 1998
Application Purpose
Original Equipment
Date of Application
Sep 10, 1998
Equipment Note
R\C Transmitter
Frequency Range
310.00000000 - 310.00000000
Company
Samhong Engineering Co, Ltd
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Schematics

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ONETECH Corp. 2F. KUNHAN BD, 1557-11 SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA TEL: 587-9037 FAX: 587-9039 ONETECH USER’S MANUAL & SCHEMATIC (BLOCK DIAGRAM) PRODUCTMULTI CODE TRANSMITTER FCC IDN55CARPER310 MODEL NO.CARPER310SERIAL NO.N/A APPLICANT & ADDRESS SAMHONG ENGINEERING CO., LTD. 324-4, DANG JUNG-DONG, KUMPO-SI, KYUNGKI-DO, 435-030, KOREA REPORT NO.E989R-008ISSUE DATESeptember 8, 1998 PREPARED BY : ONETECH CORPORATION 2 F. KUNHAN B/D, 1557-11, SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA (TEL)02-587-9037, (FAX)02-587-9039 SECURITY / REMOTE CONTROL TRANSMITTER CERTIFICATION TO FCC PART 15 REQUIREMENT

External Photos

ONETECH Corp. 2F. KUNHAN BD, 1557-11 SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA TEL: 587-9037 FAX:587-9039 ONETECH PHOTO REPORT PRODUCTMULTI CODE TRANSMITTER FCC IDN55CARPER310 MODEL NO.CARPER310SERIAL NO.N/A APPLICANT & ADDRESS SAMHONG ENGINEERING CO., LTD. 324-4, DANG JUNG-DONG, KUMPO-SI, KYUNGKI-DO, 435-030, KOREA REPORT NO.E989R-008ISSUE DATESeptember 8, 1998 PREPARED BY : ONETECH CORPORATION 2 F. KUNHAN B/D, 1557-11, SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA (TEL)02-587-9037, (FAX)02-587-9039 SECURITY / REMOTE CONTROL TRANSMITTER CERTIFICATION TO FCC PART 15 REQUIREMENT

ID Label/Location Info

ONETECH Corp. 2F. KUNHAN BD, 1557-11 SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA TEL: 587-9037 FAX:587-9039 ONETECH IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The label included following statement will be attached on the bottom of product. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : N55CARPER310

Test Report

ONETECH Corp. 2F. KUNHAN BD, 1557-11 SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA TEL: 587-9037 FAX: 587-9039 ONETECH ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT PRODUCTMULTI CODE TRANSMITTER FCC IDN55CARPER310 MODEL NO.CARPER310SERIAL NO.N/A APPLICANT & ADDRESS SAMHONG ENGINEERING CO., LTD. 324-4, DANG JUNG-DONG, KUMPO-SI, KYUNGKI-DO, 435-030, KOREA REPORT NO.E989R-008ISSUE DATESeptember 8, 1998 PREPARED BY : ONETECH CORPORATION 2 F. KUNHAN B/D, 1557-11, SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA (TEL)02-587-9037, (FAX)02-587-9039 SECURITY / REMOTE CONTROL TRANSMITTER CERTIFICATION TO FCC PART 15 REQUIREMENT REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: September 8, 1998 LIST OF EXHIBITS FCC ID: N55CARPER310 MODEL : CARPER310 EXHIBIT 1. IDENTIFICATION LABEL 2. AGENT AUTHORIZATION 3. MODIFICATION LIST 4. TECHNICAL INFORMATION: ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT 5. PHOTO REPORT 6. USER’S MANUAL & SCHEMATIC (BLOCK DIAGRAM) PREPARED BY:ONETECH CORPORATION 2 F. KUNHAN B/D, 1557-11, SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA (TEL)02-587-9037(FAX)02-587-9039 REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: September 8, 1998 EXHIBIT 1. IDENTIFICATION LABEL: PROPOSED FCC LABEL (Part15 sec. 15.19) The label included following statement will be attached on bottom side of product. “Please find an ID Label for EUT at ID Label/Location Info in Exhibit Type” This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : N55CARPER310 REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: September 8, 1998 EXHIBIT 2. AGENT AUTHORIZATION: “Please find an Agent Authorization Letter at Attestation Statements in Exhibit Type” REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: September 8, 1998 EXHIBIT 3. MODIFICATION LIST: “There was no modified items during EMI test” REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: September 8, 1998 EXHIBIT 4. TECHNICAL INFORMATION: ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT PRODUCTMULTI CODE TRANSMITTER FCC IDN55CARPER310 MODEL NO.CARPER310SERIAL NO.N/A APPLICANT & ADDRESS SAMHONG ENGINEERING CO., LTD. 324-4, DANG JUNG-DONG, KUMPO-SI, KYUNGKI-DO, 435-030, KOREA REPORT NO.E989R-008ISSUE DATESeptember 8, 1998 PREPARED BY : ONETECH CORPORATION 2 F. KUNHAN B/D, 1557-11, SEOCHO-DONG, SEOCHO-KU, SEOUL 137-070 KOREA (TEL)02-587-9037, (FAX)02-587-9039 SECURITY / REMOTE CONTROL TRANSMITTER CERTIFICATION TO FCC PART 15 REQUIREMENT REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: September 8, 1998 TABLE OF CONTENTS page 1. VERIFICATION OF COMPLIANCE................................................................................................................. 1 2. GENERAL INFORMATION .............................................................................................................................. 2 2.1 Product Description .........................................................................................................................................................2 2.2 Related Submittal(s) / Grant(s)........................................................................................................................................2 2.3 Test System Details .........................................................................................................................................................2 2.4 Test Methodology............................................................................................................................................................2 2.5 Test Facility.....................................................................................................................................................................2 3. SYSTEM TEST CONFIGURATION ................................................................................................................. 3 3.1 Justification .....................................................................................................................................................................3 3.2 Equipment Modifications ................................................................................................................................................3 3.3 Configuration of Test System..........................................................................................................................................3 4. PRELIMINARY TESTS ..................................................................................................................................... 4 4.1 AC Power line Conducted Emissions Tests ....................................................................................................................4 4.2 Radiated Emissions Tests ................................................................................................................................................4 5. CONDUCTED AND RADIATED MEASUREMENT PHOTOS ...................................................................... 5 6. FINAL RESULT OF MEASUREMENT ............................................................................................................ 7 6.1 Conducted Emissions Tests .............................................................................................................................................7 6.2 Field Strength of the Carrier Test ....................................................................................................................................8 6.3 Spurious Emission Test ...................................................................................................................................................9 6.4 Bandwidth of the operating frequency ...............................................................................................................…

Text truncated - open the document above for the full version.

Test Report

REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: October 12, 1998 6.2 Field Strength of the Carrier Test The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical. Humidity Level: 60 % Temperature : 22 Limits apply to: FCC CFR 47, PART 15, SUBPART C Result: PASSED BY –28.31 at Average mode and -8.41 dB at Peak mode Operating Condition: TX modeDate: October 12, 1998 Distance: 3 Meter Radiated EmissionsAnt Correction Factors TotalFCC Limit Ampl. (dBuV)Margin(dB)Carrier Freq. (MHz) AveragePeak Pol. Ant. (dB/m) Cable (dB) Average (dBuV/m) Peak (dBuV/m) Limit (dBuV/m) AveragePeak 31027.447.3H14.415.2047.0166.9175.32-28.31-8.41 *Remark: FCC Limit: 3,750 ~ 12,500uV/m to 260 ~ 470 MHz (linear interpolations) Limit calculation at 310 MHz = (12,500 – 3,750)/(470 – 260) X (310 – 260) + 3,750 = 5,833.3uV/m 20Log 5,833.3 = 75.32dBuV/m REPORT NO.: E989R-008FCC ID: N55CARPER310 DATE: October 12, 1998 6.3 Spurious Emission Test Humidity Level: 60 % Temperature : 22 Limits apply to: FCC CFR 47, PART 15, SUBPART C Result: PASSED BY –13.65 dB at Peak mode Operating Condition: TX mode Date: October 12, 1998 Distance: 3 Meter Radiated EmissionsAntExt.Correction FactorsTotal(dBuV/m)FCC Limit(dBuV/m) Amp.(dBuV)PeakLimitMargin(dB)Freq. (MHz) AveragePeak Pol. RF Amp. (dBuV) Ant. (dBuV) Cable (dB) Average AveragePeak 620.00*15.60H019.296.78-41.6755.32--13.65 930.00*6.80H023.177.76-37.7355.32--17.59 1240.00*24.50H2527.978.30-35.7755.32--19.55 Other spurious frequencies were not found up to 3000 MHz. *Remark: FCC Limit: 375 ~ 1,250uV/m to 260 ~ 470MHz (linear interpolations) Limit calculation at 310 MHz (Carrier Freq.) = (1,250 – 375)/(470 – 260) X (310 – 260) + 375 = 583.33uV/m 20Log 583.33 = 55.32dBuV/m The marked “*” means less than 10dBuV.

Contact Information

Applicant

Ki -Jung Kim(Manager)
+82-343-29-0981Fax: +82-343-29-0984

Technical Contact

ONETECH CORPORATIONYONG-KWANG, KWON
[email protected]+82-347-765-8289

426-1, DAESSANGRYUNG-RI, CHOWOL-MYUN, KWANGJU-KUN · KYUNGGI-DO · South Korea

Non-Technical Contact

ONETECH CORPORATIONI. C. KIM
[email protected]+82-2-587-9037

Test Firm

Onetech CorporationIhn-Cheol Kim
- -

Technical Specifications

#Rule PartsFrequency RangePower Output
115C310 MHz - 310 MHz-

Other Applications from Samhong Engineering Co, Ltd

DIGITAL MULTI CODE TRANSMITTER - FCC ID N55CARPER390 - Samhong Engineering Co, Ltd
N55CARPER390

DIGITAL MULTI CODE TRANSMITTER

Oct 27, 1999

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Garage Door Opener - FCC ID N55CARPER300 - Samhong Engineering Co, Ltd
N55CARPER300

Garage Door Opener

Nov 29, 1998

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Auto Security System Transmitter - FCC ID N55CARPER318 - Samhong Engineering Co, Ltd
N55CARPER318

Auto Security System Transmitter

Nov 17, 1998

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter