FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Panasonic Corporation of North America/
  3. N74-OMNIP400

N74-OMNIP400Active RFID Security Tag

Panasonic Corporation of North America
Active RFID Security Tag - FCC ID N74-OMNIP400 - Panasonic Corporation of North America
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 24, 2014
Application Purpose
Original Equipment
Date of Application
Aug 24, 2014
Equipment Note
Active RFID Security Tag
Frequency Range
433.27200000 - 433.27200000
Company
Panasonic Corporation of North America
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Visit w ww.o mni-id.com to l ear n more about Omni-ID® Power 400 The Omni-ID Power 400 is a r ugged a c tive tag capa ble of tremendous per formance whi le track in g as sets i n hars h environments. O ver- molded for maximum durabilit y a nd providing flexib le mounti ng o ptions, the Power 400 i nc lude s enough batter y capacit y for at least 5 years of dut y in alm ost al l applicatio ns. R adio commu ni cations penetrate snow/moist ure and provide exceptional dista nce. Building Intelligent Supply Chains Omni-ID Power 400 is per fec t for applicatio ns requiri ng long rang e as set tra ck ing, par ticu lar ly i n harsh e nvironment s: � M an ufac turi ng: M obil e car ts, contai ners a nd trol ley s � Logistics: Lay down yards, vehicles and docks Power* 5 yrs or 52 mil transmits under normal use Not required � Construc tion: Staging and materials tagging Physical Specifications Size (mm) 120 × 36 × 30 Size (in) 4.72 × 1.42 × 1.18 Weight (g) 92 Dimensions stated in mm DS0065-I PAGE 1 OF 2 Frequenc y R ange 433 MH z 860 – 930 MH z Read R ange ** 400m 3 - 6m Memor y n/a 1k bit RFID Proprietar y EPC Gen2 passive tag wakeup and data bridge (Monza® X-2K ) * Outdoor installation t ypical power settings shown. **Read distance can var y based on site, base station antenna compatibilit y and tag configurations. Visit w ww.o mni-id.com to l ear n more about Powerful Features: � Long Batter y Li fe — Bat ter y lasts at l east 5 y ear s unde r t ypic al use c ases � Integrated Pass ive Tag — Tr ack , t r igg er and commi ssion with stand ard re ade rs � Exception al To ughn ess — Fu lly s ea l ed a nd ove r mold ed fo r the most rugg ed us e. � H igh G a in Inter nal Antenna— Exce ptiona l r ang e and p er fo rman ce in snow, ic e or mud. Environmental Specifications Operating Temperature –40°C to +60°C IP R ating IP68 Nema PW12 (high pressure liquids immersion) Shock and Vibration IK07 4' drop to concrete MIL-810F Attachment Screw attachment with t wo #8 screws 5mm (0.2") Cable tie slots each end Colors and Labeling Gray with custom color options Can be source encoded and labeled Cer tifications EN55022 Class A, EN50082-2 CSA, RoHS FCC Par t 15 and ICES-003 Warrant y 1 year Ordering Information Produc t Name: Description OMNI Power 400 Ac tive RFID tag (433 MH z) Outdoor rated Shipped in minimum boxes of 128 FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Omni-ID office locations: US | UK | China | India | Southeast Asia For produc t or technology inquiries email: [email protected] DS0065-I PAGE 2 OF 2 2013 Omni-ID All rights reser ved.. 082013

Cover Letter(s)

Confidentiality Le tter Date: 6/10/2013 Subject: Confide ntiality Request f or F CC I D: N74-OMNIP400 IC: 10366A-OMNIP400 Pursua nt t o FCC 47 CRF 0.457(d) and 0.459 and IC R SP-100, Section 10, the applic ant requests tha t a part of the sub ject F CC/IC application be held confidentia l. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent User’s Manual OMNI-ID has spent substant ial e ffort i n develop ing this product a nd it is one of the first o f its kind in industry. Having the sub ject i nformati on easily available to "competition" w ou ld negate the advantage t hey have achieved by developing thi s product. Not protecting the details of t he design will r esult i n financial hardship. Permanent C onfidentiality: The applicant r equests the exhibits listed abov e as permanently confide ntial be permanently withheld from public review due to materials tha t contain trade secrets and prop rietary inf ormation not customaril y released to the public. Sincerely, By: Edmond S. Nabr otzky (Print name) QF094230 Page 1 of 1 Revision 0

External Photos

External Photos FCC ID: N74-OMNIP400 IC: 10366A-OMNIP400

ID Label/Location Info

Label & Location Photos FCC ID: N74-OMNIP400 IC: 10366A-OMNIP400

Internal Photos

FCC ID: N74-OMNIP400 IC: 10336A-OMNP400 Omni-ID Corporate Headquarters: 1200 Ridgeway Avenue Rochester, NY 14615 585-713-1000 www.Omni-ID.com Co mponent Side Interna l Pho tograph – Coil Antenna Shown ins ide Red Box FCC ID: N74-OMNIP400 IC: 10336A-OMNP400 Omni-ID Corporate Headquarters: 1200 Ridgeway Avenue Rochester, NY 14615 585-713-1000 www.Omni-ID.com Opposite Side Internal Photograph

Test Report

FCC ID: N74-OMNIP400 IC: 10336A-OMNIP400 Report No.: 31352153.004 P400 Active Tag.doc Page 1 of 30 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TUV Rheinland of North America, Inc., 12 Commerce Road, Newtown, CT 06470-1607, Tel: 203-426-0888, Fax: 203-426-4009 MS-0005239 Version 2.0 Electromagnetic Compatibility Test Report Prepared in accordance with FCC Part 15C, RSS-210 Issue 8 and ANSI C63.10 On Active RFID Tag P400 OMNI-ID 1200 Ridgeway Avenue Rochester, NY 14615 Prepared by: TUV Rheinland of North America, Inc. FCC ID: N74-OMNIP400 IC: 10336A-OMNIP400 Report No.: 31352153.004 P400 Active Tag.doc Page 2 of 30 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TUV Rheinland of North America, Inc., 12 Commerce Road, Newtown, CT 06470-1607, Tel: 203-426-0888, Fax: 203-426-4009 MS-0005239 Version 2.0 MANUFACTURERS STATEMENT FCC ID: N74-OMNIP400 IC: 10336A-OMNIP400 Report No.: 31352153.004 P400 Active Tag.doc Page 3 of 30 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TUV Rheinland of North America, Inc., 12 Commerce Road, Newtown, CT 06470-1607, Tel: 203-426-0888, Fax: 203-426-4009 MS-0005239 Version 2.0 Client: OMNI-ID 1200 Ridgeway Avenue Rochester, NY 14615 Contact: Tel: Fax: e-mail Len Desmond 585-713-1021 [email protected] Identification: Active RFID Tag Serial No.: 0D25 0103 1000 1610 Test item: Model P400 Date Test Completed: 8/30/2014 Testing location: TUV Rheinland of North America 336 Initiative Drive Rochester, NY 14624-6217 U.S.A. Tel: (585) 426-5555 Fax: 585-568-8338 Test specification: Emissions: FCC Part 15.231 Radiated Emissions Std FCC Part 15.209 and RSS - 210 Issue 8, FCC Part 15.231(b) and RSS - 210 Issue 8, FCC Part 15.231(c) and RSS - 210 Issue 8 Test Result: The above product was found to be Compliant to the above test standard(s) tested by: Randall Masline reviewed by: Cecil Gittens 11 August 2014 Date Name Signature 11 August 2014 Date Name Signature Other Aspects: None Abbreviations: OK, Pass, Compliant, Complies = passed Fail, Not Compliant, Does Not Comply = failed N/A = not applicable Industry Canada VCCI BSMI US5253 Testing Cert.# 3331.04 3466C-1 A-0037 SL2-IN-E- 050R FCC ID: N74-OMNIP400 IC: 10336A-OMNIP400 Report No.: 31352153.004 P400 Active Tag.doc Page 4 of 30 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This test report may not be published or duplicated in part without permission of the testing body. This test report by itself does not constitute authorization for the use of any TUV Rheinland test mark. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TUV Rheinland of North America, Inc., 12 Commerce Road, Newtown, CT 06470-1607, Tel: 203-426-0888, Fax: 203-426-4009 MS-0005239 Version 2.0 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................... 5 1.1 SCOPE ......................................................................................................................................................... 5 1.2 PURPOSE ..................................................................................................................................................... 5 1.3 SUMMARY OF TEST RESULTS ..................................................................................................................... 6 2 LABORATORY INFORMATION ................................................................................................................ 7 2.1 ACCREDITATIONS & ENDORSEMENTS ........................................................................................................ 7 2.2 MEASUREMENT UNCERTAINTY EMISSIONS ............................................................................................... 8 2.3 CALIBRATION TRACEABILITY .................................................................................................................... 8 2.4 MEASUREMENT EQUIPMENT USED ............................................................................................................ 9 3 PRODUCT INFORMATION ....................................................................................................................... 10 3.1 EQUIPMENT MODIFICATIONS ............................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: N74VIEW4 IC: 10336A-OMNIV4 Omni-ID Corporate Headquarters: 1200 Ridgeway Avenue Rochester, NY 14615 585-713-1000 www.Omni-ID.com Test Setup Photos FCC ID: N74VIEW4 IC: 10336A-OMNIV4 Omni-ID Corporate Headquarters: 1200 Ridgeway Avenue Rochester, NY 14615 585-713-1000 www.Omni-ID.com External Photograph Back

Contact Information

Applicant

Ben Botros(Manager - Regulatory & Compliance)
[email protected]201-348-7760Fax: 201-348-7760

Technical Contact

OMNI-IDLeonard Desmond
[email protected]585-713-1021

1200 Ridgeway Ave · Rochester, New York · United States

Non-Technical Contact

OMNI-IDEdmond Nabrotzky
[email protected]585-713-1021

Test Firm

TUV Rheinland of North America Inc.Bruce Fagley
[email protected]585-426-5555Fax: 585 568 8338

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
115.231433.272 MHz - 433.272 MHz1.00 mW424KFD110.0000000000 ppm
Confidentiality
Long Term
Grant Notes
This grant will become invalid upon any unapproved changes to the circuit board or components. Any changes would require a Class One or Class Two Permissive change. The antenna cannot be changed from the current configuration. The device must be placed to provide a separation distance of at least 20 cm from all persons.

Other Applications from Panasonic Corporation of North America

Active RF Security Tag - FCC ID N74-CP8563 - Panasonic Corporation of North America
N74-CP8563

Active RF Security Tag

Jul 12, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Active RF Security Tag - FCC ID N74-CP8564 - Panasonic Corporation of North America
N74-CP8564

Active RF Security Tag

Jun 27, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
RFID Security Interrogator - FCC ID N74-OMNIGTW - Panasonic Corporation of North America
N74-OMNIGTW

RFID Security Interrogator

Aug 28, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Active RFID Security Tag - FCC ID N74-OMNIV4 - Panasonic Corporation of North America
N74-OMNIV4

Active RFID Security Tag

Aug 28, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter