• The test results reported in this report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited FCC ID : N8Q5357-5358-1-R The Coleman Company, Inc. Application For Certification (FCC ID: N8Q5357-5358-1-R) RF Lighting Device WO# 9809628 WN/at December 24, 1998 INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R ii MEASUREMENT/TECHNICAL REPORT The Coleman Company, Inc. - MODEL: Coleman 5357H705 Coleman 5358H705 FCC ID: N8Q5357-5358-1-R December 24, 1998 This report concerns (check one:)Original Grant X Class II Change Equipment Type: RF Lighting Device (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date Report prepared by:Wilbur Ng Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone:852-2746-8680 Fax:852-2785-5487 INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R iii Table of Contents 1.0 General Description................................................................................................................. 2 1.1 Product Description ................................................................................................................ 2 1.2 Related Submittal(s) Grants .................................................................................................... 2 1.3 Test Methodology ................................................................................................................... 3 1.4 Test Facility ............................................................................................................................ 3 1.5 Equipment List ....................................................................................................................... 4 2.0 System Test Configuration...................................................................................................... 6 2.1 Justification............................................................................................................................. 6 2.2 EUT Exercising Software ....................................................................................................... 6 2.3 Special Accessories................................................................................................................. 6 2.4 Equipment Modification ......................................................................................................... 7 2.5 Support Equipment List and Description ................................................................................ 7 3.0 Emission Results....................................................................................................................... 9 3.1 Field Strength Calculation..................................................................................................... 10 3.1 Field Strength Calculation (cont) ..........................................................................................11 3.2 Radiated Emission Configuration Photograph ...................................................................... 12 3.3 Radiated Emission Data ........................................................................................................ 14 4.0 Equipment Photographs........................................................................................................ 17 5.0 Product Labelling................................................................................................................... 19 6.0 Technical Specifications......................................................................................................... 21 7.0 Instruction Manual................................................................................................................ 23 INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R iv List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated1.jpg, radiated2.jpg External PhotoExternal Photoophoto1.jpg, ophoto4.jpg Internal PhotoInternal Photoiphoto1.jpg to iphoto8.jpg Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R 2 1.0General Description 1.1Product Description The Equipment under test is a remote control fluorescent lantern. It is powered by eight ‘D’ batteries, 12Vdc. It consist of a receiver and a RF lighting device. The RF lighting device part is operated with 40kHz. The model: Coleman 5357H705 and Coleman 5358H705 are same hardware aspect except the housing and PCB layout. The brief circuit description is saved with filename: descri.pdf 1.2Related Submittal(s) Grants This is a single application for certification of a RF lighting device. The FCC ID of the associated transmitter is N8Q5357-5358-1-T and the receiver is under DOC procedure. INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R 3 1.3Test Methodology Radiated emission measurements were performed according to the procedures MP-5. All measurements were performed in Open Area Test Sites. Preliminary scans were performed in the Open Area Test Sites only to determine worst case m…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R Company: The Coleman Company, Inc. Date of Test: October 23, 1998 Model: Coleman 5357H705 Mode: Low Table 2 Radiated Emissions Frequency Reading A ntenna Pre- N et LimitMargin (MHz) (dB μV ) Factor A m p at 3m at 3m (dB) (dB) G ain(dBμV /m) (dBμV /m) (dB) 30.429 24.6101618.640-21.4 35.481 23.4101617.440-22.6 40.368 25.5101619.540-20.5 45.294 26.1101620.140-19.9 50.731 26.2111621.240-18.8 55.220 25.5111620.540-19.5 Notes:1. Peak Detector Data unless otherwise stated. 2. All measurements were made at 3 meter. Harmonic emissions not detected at the 3- meter distance were measured at 0.3-meter and an inverse proportional extrapolation was performed to compare the signal level to the 3-meter limit. No other harmonic emissions than those reported were detected at a test distance of 0.3-meter. 3. Negative value in the margin column shows emission below limit. 4. Horn antenna and average detector are used for the emission over 1000MHz. Test Engineer: Kenneth H. M. Lam INTERTEK TESTING SERVICES FCC ID: N8Q5357-5358-1-R Company: The Coleman Company, Inc. Date of Test: October 23, 1998 Model: Coleman 5358H705 Mode: Low Table 2 (Continue) Radiated Emissions Polarity Frequency Reading A ntenna Pre- N et LimitMargin (MHz) (dB μV ) Factor A m p at 3m at 3m (dB) (dB) G ain(dBμV /m) (dBμV /m) (dB) H 30.416 24.5101618.540-21.5 H 35.474 23.2101617.240-22.8 H 40.354 26.0101620.040-20.0 H 45.281 26.4101620.440-19.6 H 50.732 27.0111622.040-18.0 H 55.218 25.6111620.640-19.4 Notes:1. Peak Detector Data unless otherwise stated. 2. All measurements were made at 3 meter. Harmonic emissions not detected at the 3- meter distance were measured at 0.3-meter and an inverse proportional extrapolation was performed to compare the signal level to the 3-meter limit. No other harmonic emissions than those reported were detected at a test distance of 0.3-meter. 3. Negative value in the margin column shows emission below limit. 4. Horn antenna and average detector are used for the emission over 1000MHz. Test Engineer: Kenneth H. M. Lam
2/F., GARMENT CENTRE, · KOWLOON · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.04 MHz - 0.04 MHz | - |

Remote Control lantern
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control Tent Light
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote Control Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote Control Fluorescent Lantern
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter