NKR-GGW12Gateway

Wistron NeWeb Corporation
Gateway - FCC ID NKR-GGW12 - Wistron NeWeb Corporation
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Aug 09, 2011
Application Purpose
Original Equipment
Date of Application
Aug 09, 2011
Equipment Note
Gateway
Frequency Range
2405.00000000 - 2480.00000000
Company
Wistron NeWeb Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DOCUMENT TRACKING – REMOVE THIS SECTION BEFORE FINAL PRODUCTION Date By Notes 6/27/2011 Kevin Lewis Created new version based on 1.0.2 to add US specs and FCC statement. Blue highlighting represents changes since v.1.0.2. Gateway GW110 / GW112 GW120 / GW122 GW140 / GW142 Table of Contents Introduction 1 Gateway Overview 2 Installation 5 Common Z-Wave Tasks 10 Network Inclusion Process 10 Network Exclusion Process 12 Safety Information 15 About GreenWave 17 Product Specifications 18 1 Introduction The GreenWave Reality platform helps create a smart, energy-efficient home through the monitoring and controlling of your appliances and electronics (referred to as “devices”). You can conserve energy with minimal impact to your lifestyle by using our products to easily manage your devices. Simply connect our Gateway to your GreenWave Reality energy management system, plug your devices into our PowerNodes, and then monitor and control the devices’ power usage through a Web browser or smartphone application. Gateway Overview The GreenWave Reality Gateway provides the network connection for GreenWave Reality PowerNodes (our smart outlet adapters that connect your devices to electrical outlets). This connection enables the Gateway to securely connect the devices you have powered through PowerNodes to your energy management system and our servers, allowing you to monitor and control your devices’ power usage remotely through a Web browser or smartphone application. The Gateway automatically connects to your PowerNodes, collecting information on energy consumption by each connected device. Once the PowerNodes are connected to the Gateway, you can control the energy consumption of each connected device automatically using GreenWave Reality Smart Controls. These user-defined Smart Controls allow you to turn devices on or off remotely through a Web browser or smartphone application or to set a schedule for automatically turning your devices on or off at pre-defined times. 3 1. Sync button: Button that syncs devices and shows current activity and status of synced devices. 2. WAN (Internet connection) error indicator: Indicator that shows whether or not the Gateway is connected to the Internet. 3. LAN (home network) error indicator: Indicator that shows whether or not the Gateway is connected to your network. 4. Power indicator: Indicator that shows whether or not the Gateway is powered. 5. Network socket (RJ45): Ethernet port to connect the Gateway to your network. 6. USB socket (on some models): Socket providing a USB connection that can be used for alternate network connections (for example, through a 3G USB network adapter). 7. Power adapter socket: Socket to plug in the Gateway power adaptor. 2 5 1 4 3 6 7 Indicators Your Gateway has sync and network indicators that display the following patterns and colors to show you its current status: Power indicator—off (no color): Gateway is off. Power indicator—steady white: Gateway is on. Sync button—two rotating green bars: Gateway is in inclusion mode to connect with other GreenWave Reality devices. When inclusion is successful, the rotating bars stop and all bars turn green for five seconds. Sync button—one rotating green bar: Gateway is in exclusion mode to disconnect from other GreenWave Reality devices. When exclusion is successful after a few seconds, the rotating bar turns off. Network indicator—off (no color): Gateway is connected to the network. Network indicator—red: Gateway is not connected to the network. Check that the Gateway is connected to your network router. Internet indicator—off (no color): Gateway is connected to the Internet. Internet indicator—red: Gateway is not connected to the Internet. Check that your network router has an active Internet connection. 5 Installation Before you install your Gateway, make sure that your home network is operating and connected to the Internet. There are four basic steps to install your Gateway: 1. Connect the Gateway to your network router. 2. Power the Gateway. 3. Verify that the Gateway is connected. 4. You are ready to install GreenWave Reality PowerNodes. 1. Connect the Gateway to Your Network Router Connect the Gateway to any available port in your home network router using the included Ethernet cable. 2. Power the Gateway Power the Gateway by plugging it into an electrical outlet using the included power adaptor. The Gateway illuminates while it is attempting to connect to the Internet. 3. Verify that the Gateway is Connected Your Gateway is connected when both the network indicator and the Internet indicator turn off, and the sync button changes from white to green. 7 4. Ready to Install Your PowerNodes The GreenWave Reality PowerNode is a smart outlet adapter that connects your devices to electrical outlets and your GreenWave Reality energy management system. This connection allows you to monitor and control your devices’ power usage remotely through a Web browser or smartphone application. Your PowerNode has a corner wheel with colored numbers to represent the room or device that the PowerNode is powering. Set the PowerNode to the colored number you want to use to identify the room or device (this is referred to as the “room color”). For example, you can set the room color to blue. Then, when you access your account through the Web or smartphone application, the corresponding room is identified by the same blue color as your PowerNode. You can set PowerNodes in different rooms to different colors to make those rooms easy to identify when managing the power sources on the Web or smartphone application. To activate your PowerNode, follow the instructions that came with the PowerNode to plug in your device and connect it to your energy management system. 9 Installation Tips Review the safety information. Be sure to review the information contained in the “Safety Information” chapter for important safety information you should follow. Keep radio signals clear. Your Gateway and PowerNodes have ante…

Text truncated - open the document above for the full version.

Cover Letter(s)

AGENCY AUTHORIZATION LETTER Date: 2011-05-05 I, Troy Chien, am Senior Principal Engineer for Wistron NeWeb Corp. hereby authorize the following to act on our behalf, as our agent, in all matters relating to all processes required according to FCC approval for Wistron NeWeb Corp. products (Grantee Code: NKR) Brown Wang If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely, Sincerely, ____________ _______________ Troy Chien / Senior Principal Engineer Wistron NeWeb Corp. Tel: 886-3-6667799 Ext 6361 Fax: 886-3-6667323 E-mail: [email protected]

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3

Internal Photos

Page 4 Page 5 Page 6 Page 7 Page 8

Test Report

Report No.: RF110712C20 1 Report Format Version 4.0.0 FCC TEST REPORT REPORT NO. :RF110712C20 MODEL NO. :GW120 (refer to item 3.1 for more details) FCC ID :NKR-GGW12 RECEIVED :Jul. 12, 2011 TESTED :Jul. 19 ~ Jul. 27, 2011 ISSUED :Aug. 02, 2011 APPLICANT : Wistron NeWeb Corp. ADDRESS : 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS : No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien 244, Taiwan, R.O.C. TEST LOCATION : No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 37 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product, certification, approval or endorsement by TAF or any government agency. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Report No.: RF110712C20 2 Report Format Version 4.0.0 Table of Contents RELEASE CONTROL RECORD...............................................................................................3 1. CERTIFICATION ...........................................................................................................4 2. SUMMARY OF TEST RESULTS ...................................................................................5 2.1 MEASUREMENT UNCERTAINTY ................................................................................5 3. GENERAL INFORMATION............................................................................................6 3.1 GENERAL DESCRIPTION OF EUT..............................................................................6 3.2 DESCRIPTION OF TEST MODES................................................................................7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ...........................................................7 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ................................8 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .............................................10 3.4 DESCRIPTION OF SUPPORT UNITS ........................................................................10 4. TEST TYPES AND RESULTS ..................................................................................... 11 4.1 RADIATED EMISSION MEASUREMENT ................................................................... 11 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT................................................. 11 4.1.2 TEST INSTRUMENTS ................................................................................................12 4.1.3 TEST PROCEDURES .................................................................................................13 4.1.4 DEVIATION FROM TEST STANDARD .......................................................................13 4.1.5 TEST SETUP ..............................................................................................................14 4.1.6 EUT OPERATING CONDITIONS ................................................................................14 4.1.7 TEST RESULTS ..........................................................................................................15 4.2 CONDUCTED EMISSION MEASUREMENT ..............................................................24 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT............................................24 4.2.2 TEST INSTRUMENTS ................................................................................................24 4.2.3 TEST PROCEDURES .................................................................................................25 4.2.4 DEVIATION FROM TEST STANDARD .......................................................................25 4.2.5 TEST SETUP ..............................................................................................................26 4.2.6 EUT OPERATING CONDITIONS ................................................................................26 4.2.7 TEST RESULTS ..........................................................................................................27 4.3 BAND EDGES MEASUREMENT ................................................................................31 4.3.1 LIMITS OF BAND EDGES MEASUREMENT .............................................................31 4.3.2 TEST INSTRUMENTS ................................................................................................31 4.3.3 TEST PROCEDURE ...................................................................................................31 4.3.4 DEVIATION FROM TEST STANDARD .......................................................................31 4.3.5 EUT OPERATING CONDITION ..................................................................................31 4.3.6 TEST RESULTS ..........................................................................................................32 5. PHOTOGRAPHS OF THE TEST CONFIGURATION..................................................35 6. INFORMATION ON THE TESTING LABORATORIES ................................................36 7. APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB.........................................................................................37 Report No.: RF110712C20 3 Report Format Version 4.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED Original release NA Aug. 02, 2011 Report No.: RF110712C20 4 Report Format Version 4.0.0 1. CERTIFICATION PRODUCT: Gateway MODEL NO.: GW120 (refer to item 3.1 for more details) BRAND: greenWAVE REALITY APPLICANT: Wistron NeWeb Corp. TESTED: Jul. 19 ~ Jul. 27, 2011 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 15, Subpart C (Section 15.2…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST TEST MODE A 2 CONDUCTED EMISSION TEST TEST MODE B 3 RADIATED EMISSION TEST TEST MODE A 4 RADIATED EMISSION TEST TEST MODE B

Contact Information

Applicant

William Su(Senior Director / System Engineering dept.)
[email protected]886-3-666-7799Fax: 886-3-666-7323

Technical Contact

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchGary Chang
[email protected]886-3-3183232

No. 19, Hwa Ya 2nd Rd., Kwei Shan Hsiang · Taoyuan Hsien · Taiwan

Non-Technical Contact

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchNatacha Chen
[email protected]886-3-3183232

Test Firm

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchRichard Chen
[email protected]886-3-3183232Fax: 886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Wistron NeWeb Corporation

NKR-ATTCGW453

Enterprise product

Aug 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NKR-LS06B

Touchscreen

Aug 24, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NKR-DWSZW

Door/Window Sensor

Aug 10, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
NKR-TELE2

TELE2

Jun 26, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NKR-VMC-SA525MAX

NAD (Network Access Device)

Jun 05, 2026

Equipment Class

CXX - Communications Rcvr for use w/ licensed Tx and CBs