FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Wistron NeWeb Corporation/
  3. NKR-LS05

NKR-LS05Keypad

Wistron NeWeb Corporation
Keypad - FCC ID NKR-LS05 - Wistron NeWeb Corporation
Click to zoom

Application Details

Equipment Class
PUB - Part 15 Unlicensed PCS Base Station
Date of Grant
Apr 17, 2023
Application Purpose
Original Equipment
Date of Application
Apr 17, 2023
Equipment Note
Keypad
Frequency Range
1921.53600000 - 1928.44800000
Company
Wistron NeWeb Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Keypad Safety & Regulatory Information Important safety information 1. Read and keep these instructions. 2. Clean only with a dry cloth. 3. Set up in accordance with the manufacturer’s instructions. 4. Do not set up near any heat sources such as radiators, heat registers, stoves or other devices (including amplifiers) that produce heat. 5. Only use attachments/accessories specified by the manufacturer. 6. The device should not be exposed to dripping or splashing water. Items filled with liquids, such as vases or hoses, should not be placed on or near the device. 7. Do not store batteries with hazardous or combustible materials. Batteries can explode, catch fire and/or cause burns if disassembled, punctured, cut, crushed, short-circuited, incinerated, recharged (disposable cells) or exposed to water, fire or high temperatures. 8. Keep batteries away from children. 9. Store spare batteries in a cool, dry and ventilated area. 10. Do not use counterfeit or inferior-quality batteries. Do not use rechargeable batteries. 11. Disposing of your device and old battery: ADT is committed to environmental protection and sustainability. We strongly encourage you to recycle your device and old battery in accordance with local waste and recycling laws. The device and battery cannot be disposed of with regular household waste. Please visit call2recycle.org and, in the “Find a recycling location” field, enter your ZIP Code to find your nearest battery recycling facility. © 2023 ADT LLC dba ADT Security Services. All rights reserved. ADT, the ADT logo, (800) ADT-ASAP and the product/service names listed in this document are marks and/ or registered marks. Unauthorized use is strictly prohibited. Third-party marks are the property of their respective owners. License information available at ADT.com or by calling (800) ADT-ASAP. CA ACO7155, 974443, PPO120288; MA 172C; NC Licensed by the Alarm Systems Licensing Board of the State of North Carolina; 2736-CSA, 2397-CSA, 2381-CSA; NY 12000305615, 12000261120; PA 090797; MS 15019511. 22.5.26 03032023 Warranty For warranty details, visit: help.adt.com/s/article/warranty Questions? Give us a call at (888) 392-2039 or visit us at i.adt.com/keypad where you can also find the complete owner’s manual or scan the QR code below. Regulatory approvals FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. FCC radiation exposure statement • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. • This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 7.87 in. (20 cm) between the radiator and your body. Note: To view FCC information on the device, remove wall mount or desk mount to expose the label on the bottom of keypad. Open-source software notice For information about the open-source code under GPL, LGPL, MPL and other open-source licenses that are contained in this product, please visit help.adt.com/s/article/adt-open-source. In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are available for download. 12. Do not drop the device or subject it to physical shock. 13. Do not use high-voltage products around this device (e.g., electrical swatter) as this product may malfunction due to electrical shock. 14. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles and the point where it exits from the device. 15. Only use the AC adapter supplied with this device. Do not use a power supply from another device or another manufacturer. Using any other power cable or power supply may cause damage to the device and void your warranty. 16. Do not defeat the safety purpose of the polarized plug. A polarized plug has two blades, with one wider than the other. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 1 7. WARNING: This product contains chemicals known to the State of California to cause cancer and congenital disabilities or other reproductive harm. Wash hands after handling. 18. CAUTION: Risk of explosion if battery is replaced by an incorrect type. Important notice The ADT Keypad requires AC power to send smoke/CO siren detection signals to the ADT Base or other ADT-compatible device base. Not all third-party smoke/CO detectors are compatible with the ADT Keypad’s siren detection. The ADT Keypad doesn’t act a…

Text truncated - open the document above for the full version.

Attestation Statements

WINSTRON NEWEB CORP 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C. Declarations Guidelines for Unlicensed Personal Communication Service (PCS) Devices FCC Part 15, Subpart D The following provides the standard requirements for your kind reference. Details please refer to FCC Part 15, Subpart D. 15.319 (f) Operational Failure Requirements: The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude transmission of control and signaling information or use of repetitive codes used by certain digital technologies to complete frame or burst intervals. 15.319 (c) (6) If the selected combined time and spectrum windows are unavailable, the device may either monitor and select different windows or seek to use the same windows after waiting an amount of time, randomly chosen from a uniform random distribution between 10 and 150 milliseconds, commencing when the channel becomes available. 15.323 (c) (12) Fair Access: The provisions of (c)(10) or (c)(11) shall not be used to extend the range of spectrum occupied over space or time for the purpose of denying fair access to spectrum to other devices. 15.323 (c) (10) Duplex System LBT: An initiating device may attempt to establish a duplex connection by monitoring both its intended transmit and receive time and spectrum windows. If both the intended transmit and receive time and spectrum windows meet the access criteria, then the initiating device can initiate a transmission in the intended transmit time and spectrum window. If the power detected by the responding device can be decoded as a duplex connection signal from the initiating device, then the responding device may immediately begin transmitting on the receive time and spectrum window monitored by the initiating device. 15.323 (c) (11) Co-located device LBT: An initiating device that is prevented from monitoring during its intended transmit window due to monitoring system blocking from the transmissions of a co-located (within one meter) transmitter of the same system, may monitor the portions of the time and spectrum windows in which they intend to receive over a period of at least 10 milliseconds. The monitored time and spectrum window must total at least 50 percent of the 10 millisecond frame interval and the monitored spectrum must be within 1.25 MHz of the center frequency of channel(s) already occupied by that device or co-located co-operating devices. If the access criteria is met for the intended receive time and spectrum window under the above conditions, then transmission in the intended transmit window by the initiating device may commence. WINSTRON NEWEB CORP 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C. March 17, 2023 To whom it may concern, Declarations FCC ID: NKR-LS05 I, the undersigned, hereby declare that 1. The device does not use the provisions of 47CFR 15.323 (c) (6), random waiting mechanism is not used in this system. 2. The provisions of 47CFR 15.323 (c) (10) and 47CFR 15.323 (c) (11) are not used to extend the range of spectrum occupied over space or time for the purpose of denying fair access to spectrum to other devices. 3. Only the LS05 will act as the initiating device, which will initiate the establishment of the duplex connection. 4. The device complies with the provisions of 47CFR 15.319(f). The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude transmission of control and signaling information or use of repetitive codes used by certain digital technologies to complete frame or burst intervals. The following table explains the reaction of device in case of either absence of information to transmit or operational failure after a connection of its companion device is established. Circumstances Reaction of LS05 1 Switch-off companion device NA 2 On hook by companion device NA 3 Remove power from companion device A 4 Switch-off device NA 5 On hook on device side C 6 Remove power from device C A – Connection is terminated and, transmission ceases. B – Connection is terminated but device transmits control or signaling information. C – Connection is terminated but companion device transmits control or signaling information. NA – Not applicable represents the device does not contain a hook switch or a power off switch. M L – is a level specified by the manufacturer and is the maximum amount in dB by which the limiting threshold may exceed thermal noise for an EUT transmitting the maximum allowed power. 5. M L of LS05 declared by manufacturer is 30dB. If you have questions or need further information, please contact the undersigned. Regards, Name: Meichi Chen Position: Program Manager Company: Wistron NeWeb Corporation

Attestation Statements

U.S. Agent for Service of Process Attestation To the attention of Federal Communications Commission Authorization and Evaluation Division U.S. Agent Company Name:[ W-NeWeb Corporation] FRN: [0033416025] Contact Name: [Stephen Sek] Street Address: [1525 McCarthy Blvd, #206] City/Province/Zip: [Milpitas 95035, California] Telephone No: [408 666 1277] Email: [[email protected]] This letter is to confirm that we have accepted the responsibility to act as the designated U.S. Agent for service of process as required by §2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: 2023-04-11 Signed by (printed name): Stephen Sek Applicant Company name: Wistron NeWeb Corporation Grantee Code or FCC ID: NKR or NKR-LS05 Contact Name: Meichi Chen Street Address: 20 Park Avenue II, Hsinchu Science Park City/Province/Zip: Hsinchu Telephone No: 886-3-6667799 Email: [email protected] This letter is to confirm that the Applicant has designated the U.S Agent noted above for the purpose of accepting service of process on their behalf as required by §2.911(d)(7). The Applicant further acknowledges acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. Applicant Signature: Date: 2023-04-11 Signed by (printed name): Meichi Chen

Cover Letter(s)

Date: 2023-03-21 FCC ID: NKR-LS05 AUTHORIZATION LETTER To whom it may concern: I, the undersigned William Su of Wistron NeWeb Corporation hereby authorize Meichi Chen of Wistron NeWeb Corporation to act on my behalf in all matters relating to all processes required in FCC and any communication needed with the national authority. Any and all acts carried out by Meichi Chen on my behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, ----------------------------------- William Su / Senior Director / System Engineering dept. Wistron NeWeb Corporation Tel: 886-3-666-7799 ext. 6688 Fax: 886-3-666-7323 E-mail: [email protected]

External Photos

Reference No.: BEOP-WTW-P22050522_Ext Page 1/7 CONSTRUCTION PHOTOS OF EUT Reference No.: BEOP-WTW-P22050522_Ext Page 2/7 Reference No.: BEOP-WTW-P22050522_Ext Page 3/7 Reference No.: BEOP-WTW-P22050522_Ext Page 4/7 Ac adapter (Brand: ADT, Model: 1A102-1215) Reference No.: BEOP-WTW-P22050522_Ext Page 5/7 Reference No.: BEOP-WTW-P22050522_Ext Page 6/7 Ac adapter (Brand: ADT, Model: 1A101-1215-02) Reference No.: BEOP-WTW-P22050522_Ext Page 7/7

ID Label/Location Info

Label and Label Location

Internal Photos

Reference No.: BEOP-WTW-P22050522_Int Page 1/14 CONSTRUCTION PHOTOS OF EUT Reference No.: BEOP-WTW-P22050522_Int Page 2/14 Reference No.: BEOP-WTW-P22050522_Int Page 3/14 Reference No.: BEOP-WTW-P22050522_Int Page 4/14 Reference No.: BEOP-WTW-P22050522_Int Page 5/14 Reference No.: BEOP-WTW-P22050522_Int Page 6/14 Reference No.: BEOP-WTW-P22050522_Int Page 7/14 Reference No.: BEOP-WTW-P22050522_Int Page 8/14 Reference No.: BEOP-WTW-P22050522_Int Page 9/14 Reference No.: BEOP-WTW-P22050522_Int Page 10/14 Reference No.: BEOP-WTW-P22050522_Int Page 11/14 Reference No.: BEOP-WTW-P22050522_Int Page 12/14 Reference No.: BEOP-WTW-P22050522_Int Page 13/14 Reference No.: BEOP-WTW-P22050522_Int Page 14/14

RF Exposure Info

Report No.: MFBEOP-WTW-P22050522 Page No. 1 / 9 Report Format Version: 7.1.0 Reference No.: BEOP-WTW-P22050522 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1091) Report No.: MFBEOP-WTW-P22050522 FCC ID: NKR-LS05 Product: Keypad Brand: ADT Model No.: SKP5R0-01 Received Date: 2023/2/18 Test Date: 2023/3/7 Issued Date: 2023/3/28 Applicant: Wistron NeWeb Corporation Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Taiwan Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300, Taiwan FCC Registration / Designation Number: 723255 / TW2022 Approved by: , Date: 2023/3/28 May Chen / Manager This test report consists of 9 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Vito Lung / Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBEOP-WTW-P22050522 Page No. 2 / 9 Report Format Version: 7.1.0 Reference No.: BEOP-WTW-P22050522 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Applicable RF Exposure Limit .................................................................................................................................. 5 3 Test Results ................................................................................................................................................................ 7 3.1 RF Exposure ............................................................................................................................................................. 7 4 Conclusion .................................................................................................................................................................. 8 5 Information of the Testing Laboratories .................................................................................................................. 9 Report No.: MFBEOP-WTW-P22050522 Page No. 3 / 9 Report Format Version: 7.1.0 Reference No.: BEOP-WTW-P22050522 Release Control Record Issue No. Description Date Issued MFBEOP-WTW-P22050522 Original release. 2023/3/28 Report No.: MFBEOP-WTW-P22050522 Page No. 4 / 9 Report Format Version: 7.1.0 Reference No.: BEOP-WTW-P22050522 1 Certificate Product: Keypad Brand: ADT Test Model: SKP5R0-01 Sample Status: Engineering sample Applicant: Wistron NeWeb Corporation Test Date: 2023/3/7 FCC Rule Part: FCC Part 2 (Section 2.1091) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBEOP-WTW-P22050522 Page No. 5 / 9 Report Format Version: 7.1.0 Reference No.: BEOP-WTW-P22050522 2 Applicable RF Exposure Limit § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatialaverage SAR of 8 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae…

Text truncated - open the document above for the full version.

Test Report

□Normal □Internal Use ■Confidential □Restricted Confidential LS05 antenna report 2022/03/01 2 □Normal □Internal Use ■Confidential □Restricted Confidential Summary Bluetooth x1,on board printed design. DECT x1, on board printed with metal part design. Antenna performance –VSWR •2 :1 for all antennas –Isolation •> 15dB for all antennas –Efficiency •61% AVG. for DECT antenna •55% AVG. for Bluetooth antenna 3 □Normal □Internal Use ■Confidential □Restricted Confidential Antenna Configuration Model name: LS05 Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu Test personal name: Yun Chi Test equipment:MVGSG64multi-probe chamber Test software: NPAC Spherical Measurement V1.5.4 Test description: DUTplace in SG64 chamber, and run the antenna passive measurement. Test Photo Please refer as Annex file “LS05 Antenna Report for Test Update Setup Photo FCC”. Test Date: 2023/2/6 4 □Normal □Internal Use ■Confidential □Restricted Confidential Test equipment list 5 □Normal □Internal Use ■Confidential □Restricted Confidential Test Method 6 □Normal □Internal Use ■Confidential □Restricted Confidential Efficiency Unit, Avg. Gain [dBi], Peak Gain [dBi] measured results includeonboard trace loss & housing material loss BT: Monopole DECT: PIFA 7 □Normal □Internal Use ■Confidential □Restricted Confidential VSWR Maximum VSWR is 2 : 1 for all antennas 8 □Normal □Internal Use ■Confidential □Restricted Confidential Isolation Isolation more than 20dB among all antennas 9 □Normal □Internal Use ■Confidential □Restricted Confidential Antenna pattern –Bluetooth 10 □Normal □Internal Use ■Confidential □Restricted Confidential Antenna pattern –DECT

Test Report

TEST REPORT 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong SAR, China. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/. The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. © 2017 Intertek Page 1 of 58 Report Number: 23010292HKG-001R1 Application For Original Grant of 47 CFR Part 15 Certification Unlicensed Personal Communications Service Devices (Keypad Unit) FCC ID: NKR-LS05 Prepared and Checked by: Approved by: Signed on File Leung Chiu Kuen, Stanley Engineer Tang Kwan Mo, Jess Lead Engineer Date: April 11, 2023 TEST REPORT Wistron NeWeb Corporation Intertek Report No: 23010292HKG-001R1.doc Page 2 of 58 GENERAL INFORMATION Grantee: Wistron NeWeb Corporation Grantee Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C. Manufacturer Name: Wistron NeWeb Corporation Manufacturer Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C. FCC Specification Standard: FCC Part 15, October 1, 2021 Edition FCC ID: NKR-LS05 FCC Model(s): SKP5R0-01 Type of EUT: Unlicensed Personal Communications Service Devices Description of EUT: Keypad Serial Number: N/A Sample Receipt Date: January 10, 2023 Date of Test: January 10, 2023 to March 10, 2023 Report Date: April 11, 2023 Environmental Conditions: Temperature: +10 to 40°C Relative Humidity: 10 to 90% Conclusion: Test was conducted by client submitted sample. The submitted sample as received complied with the 47 CFR Part 15 Certification. 1. This report supersedes previous report with report number 23010292HKG-001 date March 22, 2023. 2. Please refer ICT-S23-0008 Letter issued on April 11, 2023 for the amendment/ supersede notification. AMENDMENT HISTORY Report No. Issued Date Content 23010292HKG-001 March 22, 2023 Original Report 23010292HKG-001R1 April 11, 2023 1. P.1 – Revise “Portable Unit” to “Keypad Unit” 2. P.6 – Section 2.1 – Revise Product Description “Portable Unit” Deleted 3. P.6 – Section 2.3 – Add “FCC designation no. HK0005" 4. P.11 – Typo mistake on “adaptor model: 1A101- 1215-02” 5. P.12 – The digital modulation techniques provided by the applicant 6. P.22 – Typo mistake on “Middle Channel, Traffic Carrier” TEST REPORT Wistron NeWeb Corporation Intertek Report No: 23010292HKG-001R1.doc Page 3 of 58 TABLE OF CONTENTS 1.0 TEST RESULTS SUMMARY & STATEMENT OF COMPLIANCE .......................................... 4 1.1 Summary of Test Results ........................................................................................... 4 1.2 Statement of Compliance ......................................................................................... 5 2.0 GENERAL DESCRIPTION ................................................................................................ 6 2.1 Product Description .................................................................................................. 6 2.2 Test Methodology ..................................................................................................... 6 2.3 Test Facility ................................................................................................................ 6 3.0 SYSTEM TEST CONFIGURATION .................................................................................... 7 3.1 Justification ............................................................................................................... 7 3.2 Radiated Emission Test Setup ................................................................................... 8 3.3 AC Line Conducted Emission Test Setup ................................................................... 9 3.4 Conducted Emission Test Configuration ................................................................... 9 3.5 Conducted Monitoring and Operational Test Configuration ................................. 10 3.6 EUT Exercising Software.......................................................................................... 10 3.7 Details of EUT and Description of Accessories ....................................................... 11 3.8 Measurement Uncertainty...................................................................................... 11 4.0 MEASUREMENT RESULTS ........................................................................................... 12 4.1 Antenna Requirement ............................................................................................. 12 4.2 Digital Modulation Techniques ............................................................................... 12 4.3 Emission Bandwidth ................................................................................................ 13 4.4 Directional Gain of the Antenna ............................................................................. 15 4.5 Peak Transmit Power .............................................................................................. 16 4.6 Power Spectral Density…

Text truncated - open the document above for the full version.

Test Setup Photos

□Normal □Internal Use ■Confidential □Restricted Confidential LS05 Antenna Report for Test Update Setup Photo 2022/03/01 2 □Normal □Internal Use ■Confidential □Restricted Confidential Antenna Configuration Model name: LS05 Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu Test personal name: Yun Chi Test equipment:MVGSG64multi-probe chamber Test software: NPAC Spherical Measurement V1.5.4 Test description: DUTplace in SG64 chamber, and run the antenna passive measurement.

Test Setup Photos

INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: NKR-LS05 Radiated Emission – DECT Transmission with AC adaptor Front View Rear View The EUT is placed at the center of turntable INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: NKR-LS05 Radiated Emission – DECT Transmission (6V Battery Box) Front View Rear View The EUT is placed at the center of turntable INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: NKR-LS05 AC Conducted Emission – DECT Talk and Charging mode Front View Side View 1 INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: NKR-LS05 AC Conducted Emission Side View 2

Contact Information

Applicant

William Su(Senior Director / System Engineering dept.)
[email protected]886-3-666-7799Fax: 886-3-666-7323

Test Firm

Intertek Testing Services Hong Kong Ltd.Billy Chow
[email protected]85221738528Fax: 85227410521

Technical Specifications

#Rule PartsFrequency RangePower Output
115D1.92 GHz - 1.93 GHz110.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Wistron NeWeb Corporation

NKR-ATTCGW453

Enterprise product

Aug 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NKR-LS06B

Touchscreen

Aug 24, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NKR-DWSZW

Door/Window Sensor

Aug 10, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
NKR-TELE2

TELE2

Jun 26, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NKR-VMC-SA525MAX

NAD (Network Access Device)

Jun 05, 2026

Equipment Class

CXX - Communications Rcvr for use w/ licensed Tx and CBs