FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HBC-radiomatic GmbH/
  3. NO9M50004

NO9M50004Micron 5

HBC-radiomatic GmbH

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Apr 24, 2002
Application Purpose
Original Equipment
Date of Application
Apr 24, 2002
Equipment Note
Micron 5
Frequency Range
902.00000000 - 918.00000000
Company
HBC-radiomatic GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

β†—

Attestation Statements

β†—

Block Diagram

β†—

Cover Letter(s)

β†—
β†—

External Photos

ID Label/Location Info

β†—

Internal Photos

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operating Instructions Radio Transmitter micron 5-3 BE-MICR5-3_V2-1.DOC [ Word 2000 ] US Page 1 / 18 HBC-radiomatic GmbH β€’ D-74564 Crailsheim β€’ GERMANY Information and specifications subject to change without notice. 02-13-2002 Radio Control System HBC – Radio Control R R a a d d i i o o T T r r a a n n s s m m i i t t t t e e r r m m i i c c r r o o n n 5 5 - - 3 3 Operating Instructions Radio Transmitter micron 5-3 Page 2 / 18 BE-MICR5-3_V2-1.DOC [ Word 2000 ] US HBC-radiomatic GmbH β€’ D-74564 Crailsheim β€’ GERMANY 02-13-2002 Information and specifications subject to change without prior notice. Radio Control System Manufacturer: HBC-radiomatic GmbH Haller Strasse 49 - 53 74564 Crailsheim β€’ Germany Tel. +49 ( 0 ) 79 51 – 3 93 - 0 Fax +49 ( 0 ) 79 51 – 3 93 – 50 E-mail: [email protected] http://www.hbc-radiomatic.com HBC-radiomatic GmbH is not liable for any misprints or errors! – All rights reserved. β„’ radiomatic is a registered German trademark. Β© 2002 – 02 , HBC-radiomatic GmbH , D-74564 Crailsheim, Germany No part of any software or of the present document may be reproduced in any manner whatsoever without the expressed written permission of HBC-radiomatic GmbH. Operating Instructions Radio Transmitter micron 5-3 BE-MICR5-3_V2-1.DOC [ Word 2000 ] US Page 3 / 18 HBC-radiomatic GmbH β€’ D-74564 Crailsheim β€’ GERMANY Information and specifications subject to change without notice. 02-13-2002 Radio Control System Table of Contents 1 Description...................................................................................4 2 Safety Instructions........................................................................5 2.1 Pictographs.......................................................................................5 2.2 General Safety Instructions................................................................6 2.3 Operator Safety Instructions..............................................................7 3 Operation......................................................................................8 Activating the transmitter..................................................................8 Frequency Selector (Scanner)............................................................9 Transmitter Inscription....................................................................10 3.1 Battery and Battery Charger.............................................................11 3.1.1 FuB 3A Transmitter Battery.................................................11 3.1.2 FLG 105 Battery Charger.....................................................11 4 Fault Correction..........................................................................12 5 Maintenance................................................................................13 5.1 In the Event of a Fault......................................................................13 6 Technical Data............................................................................14 Dimensions......................................................................................15 6.1 Accessories.....................................................................................16 7 Certificates and Approvals.........................................................17 Operating Instructions Radio Transmitter micron 5-3 Page 4 / 18 BE-MICR5-3_V2-1.DOC [ Word 2000 ] US HBC-radiomatic GmbH β€’ D-74564 Crailsheim β€’ GERMANY 02-13-2002 Information and specifications subject to change without prior notice. Radio Control System 1 Description The micron 5-3 transmitter is designed to transmit command instructions for controlling industrial cranes and hoists as well as operating machines and plants. Depending on the type and version selected, up to 14 control commands plus the integrated safety commands are available to the operator. A non-interchangeable system address ensures the functional safety of the radio control system when operating cranes or machines. This feature is particularly important when several cranes or machines are in use, for example in halls and shops. The system address is exclusively allocated to each HBC radio transmitter and its respective receiver. It is not possible to activate crane or machine functions using a radio control system allocated to another crane or machine. The transmitter has general telecommunications approvals. It is not necessary to have or to apply for a license to operate the transmitter with the respective receiver. The transmitter broadcasts in either a 30 cm or 70 cm bandwidth. The transmitter is equipped with < 5 mW or < 10 mW transmitting power. Operating the transmitter using a different frequency range or transmitting power requires the approval of the competent regulative authorities for telecommunication. High-quality radio technology pursuant to the guidelines laid down by the German Regulative Authorities for Telecommunications and Postal Services and the Regulations For The Prevention of Accidents combined with perfected microprocessor technology guarantees the highest degree of operative safety, service quality and serviceable life. Operating Instructions Radio Transmitter micron 5-3 BE-MICR5-3_V2-1.DOC [ Word 2000 ] US Page 5 / 18 HBC-radiomatic GmbH β€’ D-74564 Crailsheim β€’ GERMANY Information and specifications subject to change without notice. 02-13-2002 Radio Control System 2 Safety Instructions 2.1 Pictographs The following pictographs will be used throughout the present operating instructions : Indicates a possible shock hazard Contacting components under voltage may lead to death. Housing (e.g. hoods and lids) marked with this symbol may only be opened by qualified electricians after having disconnected the device from the mains supply (supply voltage, operating voltage or input terminal voltage). Indicates safety relevant passages You will find this pictograph as an indicator for occupational safety measures. The neglecting of such measures poses a serious hazard. Always observe the instructions and …

Text truncated - open the document above for the full version.

Attestation Statements

ATTESTATION STATEMENT FCC ID: NO9M50004 Remote control transmitter micron 5 SUMMARY: All tests according to FCC Part Subpart C Paragraph 15.249 Β„ - Performed The equipment under test Β„ - Fulfills the general approval requirements of FCC Part Subpart C Paragraph 15.249 - MIKES BABT PRODUCT SERVICE GmbH - Responsible Engineer ____________________________ Anton Altmann

Cover Letter(s)

TEST TEST A w avelength ahead Telefon: +49-9424-9407-0 Telefax: +49-9424-9407-60 e-mail [email protected] Internet: http//www.babtps.com 2001-11-16 Agent Authorization Letter Dear Sir or Madam: We, MIKES BABT Product Service GmbH, Ohmstrasse 2-4, D-94342 Strasskirchen, Germany, hereby authorize BABT Product Service, 4855 Patrick Henry Drive, Building 6, Santa Clara, CA 95054 to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. I further certify that the applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862. This authorization expires on 16 November 2002. Sincerely, Thomas Weise Dipl.Ing. (FH) Laboratory Manager Tel.: +49 9424 9407 0 Fax.: +49 9424 9407 60 TCB BABT Product Service 4855 Patrick Henry Drive, Building 6 Santa Clara, CA 95054 MIKES BABT Product Service Postfach 28  94340 Strasskirchen

Test Report

FCC ID: NO9M50004 TTI - P-G 009 / 98-00 TTI - P-G 089 / 94-50 File No. T 21804-1-01 AA , Page 1 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 E M I S S I O N -- T E S T R E P O R T Test Report File No. : T 21804-1-01 AA ________________ Date : April 22, 2002 of issue ________________ Type Designation: micron 5 ______________________________________________ Kind of Product: Remote Control Transmitter ______________________________________________ Applicant: HBC-radiomatic GmbH ______________________________________________ Manufacturer: HBC-radiomatic GmbH ______________________________________________ Licence holder: HBC-radiomatic GmbH ______________________________________________ Address: Haller Str. 49-53 ______________________________________________ 74564 Crailsheim ______________________________________________ Test result accdg. to the regulation(s) at page 3 : Positive This test report with attachment consists of 38 pages. The test result only corresponds to the tested sample. It is not permitted to copy this report, in part or in full, without the permission of the test laboratory. FCC ID: NO9M50004 File No. T 21804-1-01 AA , Page 2 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 D I R E C T O R Y Page Documentation Directory2 ________ Test regulations3 ________ General information4-5 ________ Discovery of worst case condition6 ________ Equipment under Test17 ________ Summary18 ________ Test data Conducted emissions 10/150 kHz - 30 MHz7 ________ Spurious emissions (magnetic field) 9 kHz - 30 MHz8-9 ________ Spurious emissions (electric field) 30 MHz - 1000 MHz10-11 ________ Spurious emissions (electric field) 1 GHz - 18 GHz12-13 ________ Radiated power of the fundamental wave14-15 ________ Conducted power of the fundamental wave measured on16 the antenna terminals ________ Attachment A)Test dataA1-A3 ________ B)List of Test EquipmentB1 ________ C) Photos of the test setupC1-C2 ________ D) Technical description of the test sampleD1-D3 (e.g. CDF, Declaration) ________ E)Photos of the EuTE1-E11 ________ F)Measurement Protocol for FCC, VCCI and AUSTEL-- ________ FCC ID: NO9M50004 File No. T 21804-1-01 AA , Page 3 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T E S T R E G U L A T I O N S The tests were performed according to following regulations : o - EN 50081-1/ 2.1991 o - EN 50081-2/ 7.1993 -------------------------------------------------------------------------------- o - EN 55011/ 3.1991o - Group 1o - Group 2 o - class Ao - class B o - EN 55014/ 4.1993o - Household appliances and similar o - tools o - Semiconductor devices o - EN 55014 / A2:1990 o - EN 55104/ 5.1995Category: o - EN 55015 / A1:1990 o - EN 55015 / 12.1993 o - EN 55022 / 5.1995o - class Ao - class B o - prEN 55103-1/ 3.1995 o - prEN 50121-3-2/ 3.1995 o - EN 60601-1-2/ 4.1994 o - VCCIo - class 1o - class 2 o - Part 15 Subpart C (15.209) Β„- Part 15 Subpart C (15.249) FCC ID: NO9M50004 File No. T 21804-1-01 AA , Page 4 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 A D D R E S S O F T H E T E S T L A B O R A T O R Y Β„-MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D - 94342 Strasskirchen o - ______________________________________ ______________________________________ ______________________________________ ______________________________________ E N V I R O N M E N T A L C O N D I T I O N S Temperature:15-35 Β° C ____________ Humidity45-60 % ____________ Atmospheric pressure 860-1060 mbar ____________ POWER SUPPLY SYSTEM UTILIZED Power supply systemo 230V/50 Hz / 1φ„ 6 VDC o 400V/50 Hz 3PEo 400V/50 Hz 3NPE STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report accdg. to NIS 81 /5.1994 β€žThe Treatment of Uncertainty in EMC Measurementsβ€œ and is documented in the MIKES BABT Product Service quality system accdg. to EN 45001. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EuT) The micron 5 transmitter is designed to transmit command instructions for controlling industrial cranes and hoists as well as operating machines and plants. Number of received/tested samples:1 / 1 Serial Number:Prototype DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT Β„ The black square indicates that the listed condition, standard or equipment is applicable for this report. o Blank box indicates that the listed condition, standard or equipment was not applicable for this report. FCC ID: NO9M50004 File No. T 21804-1-01 AA , Page 5 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 M E A S U R E M E N T P R O T O C O L F O R F C C , V C C I A N D A U S T E L Test Methodology Conducted and radiated emission testing is performed according to the procedures in International Special Committee on Radio Interference (CISPR) Publication 22 (1993), European Standard EN 55022 and Australian Standard AS 3548 (which are based on CISPR 22). The Japanese standard, "Voluntary Control Council for Interference (VCCI) by Data Processing Equipment and Electronic Office Machines, Technical Requirements" is technically equivalent to CISPR 22 (1993). For official compliance, a conformance report must be sent to and accepted by the VCCI. In compliance with FCC Docket 92-152, "Harmonization of Rules for Digital Devices Incorporate International Standards", te…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: NO9M50004 File No. T 21804-1-01 AA , Page C 1 of C 2 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 Test-Setup: SPURIOUS EMISSIONS (electric field) 30 MHz - 1000 MHz FCC ID: NO9M50004 File No. T 21804-1-01 AA , Page C 2 of C 2 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 Test-Setup: SPURIOUS EMISSIONS (electric field) 1000MHz – 10-harmonics

Contact Information

Applicant

Jeff Allan(CEO of US Entity)
[email protected]+1 (859) 689-6480Fax: +1 (859) 266-7227

Test Firm

MIKES BABT Product Service GmbHHarald Buchwald
[email protected]49-9424-9481-150Fax: 49-9424-9481-240

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902 MHz - 918 MHz-
Confidentiality
Long Term

Other Applications from HBC-radiomatic GmbH

Inertial Measurement Unit - FCC ID NO9IMU - HBC-radiomatic GmbH
NO9IMU

Inertial Measurement Unit

Aug 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
DECT ULE Radio Module - FCC ID NO9TC190 - HBC-radiomatic GmbH
NO9TC190

DECT ULE Radio Module

Jul 26, 2023

Equipment Class

PUB - Part 15 Unlicensed PCS Base Station
Remote Control technos A - FCC ID NO9TECA01 - HBC-radiomatic GmbH
NO9TECA01

Remote Control technos A

Sep 28, 2022

Equipment Class

JAD - Part 15 Class A Digital Device
RF Module 902-928 MHz frequency hopping - FCC ID NO9TC792-1 - HBC-radiomatic GmbH
NO9TC792-1

RF Module 902-928 MHz frequency hopping

Jan 27, 2021

Equipment Class

DTS - Digital Transmission System
Bluetooth Module - FCC ID NO9TC240 - HBC-radiomatic GmbH
NO9TC240

Bluetooth Module

Jul 01, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter