Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Operating Instructions Radio Transmitter spectrum 1 M BE-SP1M-V2-3(FCC).doc [ Word 2000 ] MB Page 1 / 24 HBC-radiomatic GmbH • D-74564 Crailsheim • Germany Information and specifications subject to change without notice. 2003-02-12 Radio Control System HBC – Radio Control R R a a d d i i o o T T r r a a n n s s m m i i t t t t e e r r s s p p e e c c t t r r u u m m 1 1 M M for the Constructional and Industrial Use Operating Instructions Radio Transmitter spectrum 1 M Page 2 / 24 BE-SP1M-V2-3(FCC).doc [ Word 2000 ] MB HBC-radiomatic GmbH • D-74564 Crailsheim • Germany 2003-02-12 Information and specifications subject to change without notice. Radio Control System Manufacturer : HBC-radiomatic GmbH Haller Straße 49 - 53 74564 Crailsheim • Germany Tel. +49 ( 0 ) 79 51 – 3 93 - 0 Fax +49 ( 0 ) 79 51 – 3 93 - 50 E-mail: [email protected] http://www.hbc-radiomatic.com HBC radiomatic GmbH is not liable for any misprints or errors! – All rights reserved. ™ radiomatic is a registered German trademark. © 2002 – 02 , HBC-radiomatic GmbH , D-74564 Crailsheim No part of any software or of the present document may be reproduced in any manner whatsoever without the expressed written permission of HBC-radiomatic GmbH. Operating Instructions Radio Transmitter spectrum 1 M BE-SP1M-V2-3(FCC).doc [ Word 2000 ] MB Page 3 / 24 HBC-radiomatic GmbH • D-74564 Crailsheim • Germany Information and specifications subject to change without notice. 2003-02-12 Radio Control System Table of Contents 1 Description .................................................................................... 4 2 Safety Instructions ........................................................................ 5 2.1 Pictographs.............................................................................................5 2.2 General Safety Instructions ....................................................................6 2.3 Operator Safety Instructions ..................................................................7 3 Operation....................................................................................... 8 Automatic Switch-OFF ( APO Function ) ................................................9 Slewing Gear Release .............................................................................9 3.1 Battery and Battery Charger.................................................................10 3.1.1 FuB 05 AA Transmitter Battery ................................................10 3.1.2 FLG 105 Battery Charger .........................................................10 3.2 Special Operating Modes ( Optional )...................................................11 3.2.1 Option Scanner ( Frequency Selector ) ...................................11 3.2.2 Option "Pitch – Catch".............................................................12 3.2.3 Option Tandem Operation........................................................13 3.2.4 Option infrakey ........................................................................16 3.2.4.1 infrakey Set-up ..........................................................17 4 Fault Correction ...........................................................................18 5 Maintenance .................................................................................19 5.1 In the Event of a Fault...........................................................................19 6 Technical Data..............................................................................20 6.1 Dimensions and Operating Elements of spectrum 1 M ........................21 6.1.1 Industrial Version ....................................................................21 6.1.2 Constructional Version ............................................................22 7 Certification and Approvals .........................................................23 Operating Instructions Radio Transmitter spectrum 1 M Page 4 / 24 BE-SP1M-V2-3(FCC).doc [ Word 2000 ] MB HBC-radiomatic GmbH • D-74564 Crailsheim • Germany 2003-02-12 Information and specifications subject to change without notice. Radio Control System 1 Description The spectrum 1 M transmitter is designed to transmit command instructions for controlling construction, industrial and mobile cranes, hoists and machines. Depending on the type and version selected, up to 24 control commands plus the integrated STOP commands are available to the operator. A non-interchangeable system address ensures the functional safety of the radio control system when operating cranes or machines. This feature is particularly important when several cranes or machines are in use, for example in halls and shops. The system address is exclusively allocated to each HBC radio transmitter and its respective receiver. It is not possible to activate crane or machine functions using a radio control system allocated to another crane or machine. The radio control system consists of the spectrum 1 M transmitter, two rechargeable NiCd batteries, a battery charger and a receiver with antenna. The transmitter housing with integrated antenna is made of impact resistant plastic. The transmitter is powered by rechargeable batteries. Two batteries and a memory effect-free battery charger are included. State of the art radio technology complying with the latest guidelines of the regulations on labor safety and the use of highly developed microprocessor technology guarantees optimal operating safety, availability and longevity. The transmitter has general telecommunications approvals. It is not necessary to have or to apply for a license to operate the transmitter with the respective receiver. The transmitter must be operated in the 433.100 MHz to 434.750 MHz range or 869 MHz to 870 MHz bandwidth. The transmitter is equipped with < 10 mW (average) transmitting power. Operating the radio transmitter using a different frequency range or transmitting power requires the approval of the competent regulative authorities for telecommunication. …
Text truncated - open the document above for the full version.
2x6 Keyswitch Stopswitch GND 13.02.2003 01 of 01 ( MED ) 11051a_95_MED.pdf M.Metzger / T.Renner 11.051.A.95 Blockschaltbild / block diagram Sender "eco" + "spectrum 1" Sheet File: Doc.No.: Date:Designed by / checked by: D-74555 Crailsheim Postfach 15 61HBC-radiomatic GmbH 8MHz 3V 5V level shifter Pegelwandler UB4 6,3V 6,3V UB4 TCS UB5 +5V UB5 TCS TRP1TRP2 Akku- check UART UB2 UB2 UB3 UB3 SPI UB4 UB3UB4UB5 UB5 Config Speaker IR-Key Function-LED serial Data serial Data FuS671/680 - Modul DECT-Modul MD32 (TIS) Transponder Battery 6,3V Bestückung wahlweise placement to choose ENCODER-Modul EDA Bestückung wahlweise in unterschiedlicher Anzahl placement to choose with different quantities joystick KMS switches + keys 125kHz 30 switch mode inputs 6 proportional inputs serial Data fromTEACH-Commander TEACH-Commander 2x ST5 Option for LED-Feedback Opion for LCD-Display
Attachment E1 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E2 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0
Datum: 02.12.2002 ans_spec1_typ.cdr D.Hahn AA.330.A.91 1/1 Date: Z.-Nr.: Doc.-No.: Gezeichnet / Drawn by: M.Metzger Geräteansicht Typenschilder spectrum 1 Arrangement nameplates spectrum 1 Geprüft / Checked: Datei: Blatt: File: Sheet: HBC-radiomatic GmbH Postfach 1561 D-74555 Crailsheim This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, & (2) This device must accept any interference received, including interference that may cause undesired operation. HBC-radiomatic GmbH Tel.: +49(0)7951/393-0 Made in Germany Prod.Code: spectrum 1 - MED Transmitter Ser.No.: 735-0201319/2 IP 55/Nema 4 U: 6V DC Batt. Frequency (MHz): 905,200-908,375 Frequency Block: W5-FB001 Frequ. 1 (MHz): 905,200 USA: NO9MED004CAN: XXXX.XXXX.XXX Datum: 19.02.2003 typ_spec1.cdr D.Hahn AA.326.A.93 1/1 Date: Z.-Nr.: Doc.-No.: Gezeichnet / Drawn by: M.Metzger Typenschild Spectrum1-MED nameplate spectrum1-MED Geprüft / Checked: Datei: Blatt: File: Sheet: HBC-radiomatic GmbH Postfach 1561 D-74555 Crailsheim HBC radiomatic GmbH Tel.: +49(0)7951/393-0 Made in Germany FCC-ID: CANADA: NO9MED004 2977 YYY YYYY Frequ. 1 (MHz): Frequency Block: Voltage: Frequency (MHz): IP 55 / Nema 4 Transmitter Ser.No.: Prod.Code: Spectrum1-MED W5-FB001 905,200-908,375 735-0201319/2 6VDC 905,200 Datum: 18.04.2002 typ_text_fcc.cdr D.Hahn AA.328.A.93 1/1 Date: Z.-Nr.: Doc.-No.: Gezeichnet / Drawn by: M.Metzger Text FCC Geprüft / Checked: Datei: Blatt: File: Sheet: HBC-radiomatic GmbH Postfach 1561 D-74555 Crailsheim This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, & (2) This device must accept any interference received, including interference that may cause undesired operation.
Attachment E3 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E4 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E5 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E6 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E7 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E8 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E9 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E10 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E11 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E12 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E13 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E14 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E15 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E16 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E3 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E4 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E5 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0 Attachment E6 spectrum 1 - MED FCC ID: NO9MED004 File No. T 22695-00 AA MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D-94342 Strasskirchen Tel.:+49 94 24 94 07-0 Fax:+49 94 24 94 07-60 Rev.Nr. 9.0
FCC ID: NO9MED004 TTI - P-G 009 / 98-00 TTI - P-G 089 / 94-50 File No. 1 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page E M I S S I O N -- T E S T R E P O R T Test Report File No. : T 22695-1-00 AA ________________ Date : November 13, 2002 of issue ________________ Type Designation : spectrum 1 - MED ______________________________________________ Kind of Product : Remote Control Transmitter ______________________________________________ Applicant : HBC-radiomatic GmbH ______________________________________________ Manufacturer : HBC-radiomatic GmbH ______________________________________________ Licence holder : HBC-radiomatic GmbH ______________________________________________ Address : Haller Str. 49-53 ______________________________________________ 74564 Crailsheim ______________________________________________ Test result accdg. to the regulation(s) at page 3 : Positive This test report with attachment consists of 32 pages. The test result only corresponds to the tested sample. It is not permitted to copy this report, in part or in full, without the permission of the test laboratory. FCC ID: NO9MED004 File No. 2 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page D I R E C T O R Y Page Documentation Directory 2 ________ Test regulations 3 ________ General information 4-5 ________ Discovery of worst case condition 6 ________ Equipment under Test 17 ________ Summary 18 ________ Test data Conducted emissions 10/150 kHz - 30 MHz 7 ________ Spurious emissions (magnetic field) 9 kHz - 30 MHz 8-9 ________ Spurious emissions (electric field) 30 MHz - 1000 MHz 10-11 ________ Spurious emissions (electric field) 1 GHz - 18 GHz 12-13 ________ Radiated power of the fundamental wave 14-15 ________ Conducted power of the fundamental wave measured on 16 the antenna terminals ________ Attachment A) Test data A1-A2 ________ B) List of Test Equipment B1 ________ C) Photos of the test setup C1-C2 ________ D) Technical description of the test sample D1-D3 (e.g. CDF, Declaration) ________ E) Photos of the EuT E1-E6 ________ F) Measurement Protocol for FCC, VCCI and AUSTEL -- ________ FCC ID: NO9MED004 File No. 3 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page T E S T R E G U L A T I O N S The tests were performed according to following regulations : o - EN 50081-1 / 2.1991 o - EN 50081-2 / 7.1993 -------------------------------------------------------------------------------- o - EN 55011 / 3.1991 o - Group 1 o - Group 2 o - class A o - class B o - EN 55014 / 4.1993 o - Household appliances and similar o - tools o - Semiconductor devices o - EN 55014 / A2:1990 o - EN 55104 / 5.1995 Category: o - EN 55015 / A1:1990 o - EN 55015 / 12.1993 o - EN 55022 / 5.1995 o - class A o - class B o - prEN 55103-1 / 3.1995 o - prEN 50121-3-2 / 3.1995 o - EN 60601-1-2 / 4.1994 o - VCCI o - class 1 o - class 2 o - Part 15 Subpart C (15.209) - Part 15 Subpart C (15.249) FCC ID: NO9MED004 File No. 4 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page A D D R E S S O F T H E T E S T L A B O R A T O R Y - MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D - 94342 Strasskirchen o - ______________________________________ ______________________________________ ______________________________________ ______________________________________ E N V I R O N M E N T A L C O N D I T I O N S Temperature: 15-35 ° C ____________ Humidity 45-60 % ____________ Atmospheric pressure 860-1060 mbar ____________ POWER SUPPLY SYSTEM UTILIZED Power supply system o 230V/50 Hz / 1φ 6 VDC o 400V/50 Hz 3PE o 400V/50 Hz 3NPE STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report accdg. to NIS 81 /5.1994 „The Treatment of Uncertainty in EMC Measurements“ and is documented in the MIKES BABT Product Service quality system accdg. to EN 45001. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EuT) The spectrum 1 - MED transmitter is designed to transmit command instructions for controlling industrial cranes and hoists as well as operating machines and plants. Number of received/tested samples: 1 / 1 Serial Number: Prototype DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT The black square indicates that the listed condition, standard or equipment is applicable for this report. o Blank box indicates that the listed condition, standard or equipment was not applicable for this report. FCC ID: NO9MED004 File No. 5 of 18 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page M E A S U R E M E N T P R O T O C O L F O R F C C , V C C I A N D A U S T E L Test Methodology Conducted and radiated emission testing is performed according to the procedures in International Special Committee on Radio Interference (CISPR) Publication 22 (1993), European Standard EN 55022 and Australian Standard AS 3548 (which are based on CISPR 22). The Japanese standard, "Voluntary Control Council for Interference (VCCI) by Data Processing Equipment and Electronic Office Machines, Technical Requirements" is technically equivalent to CISPR 22 (1993). For official compliance, a conformance report must be sent to and accepted by the VCCI. In compliance with FCC Docket 92-152, "Harmonizat…
Text truncated - open the document above for the full version.
FCC ID: NO9MED004 Test-Setup: SPURIOUS EMISSIONS (electric field) 30 MHz - 1000 MHz File No. C 1 of C 2 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page FCC ID: NO9MED004 Test-Setup: SPURIOUS EMISSIONS (electric field) 1000 MHz – 10 th -harmonics (9180 MHz) File No. C 2 of C 2 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.0 T 22695-1-00 AA , Page
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902 MHz - 918 MHz | - |

Inertial Measurement Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DECT ULE Radio Module
Equipment Class
PUB - Part 15 Unlicensed PCS Base Station
Remote Control technos A
Equipment Class
JAD - Part 15 Class A Digital Device
RF Module 902-928 MHz frequency hopping
Equipment Class
DTS - Digital Transmission System
Bluetooth Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter