Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Operating Instructions Radio Transmitter PM NTU BE-PM_NTU-US-L.DOC [ Word 97 ] FL Page 1 / 16 HBC-radiomatic, Inc. , Cincinnati , Ohio 45242 , USA Information and specifications subject to change without notice. 2000-08-16 Radio Control System HBC – Radio Controls R R a a d d i i o o T T r r a a n n s s m m i i t t t t e e r r P P M M N N T T U U for Industrial Cranes made for HBC-electronic Funktechnik GmbH Tel.: +49(0)7951/393-0 Made in Germany Prod.Code: SNTU 1.0 Transmitter Ser.No.: 735- IP55 / Nema 4 U: 6V DC Frequency Band (MHz): 902 918 W5 : FB1 FCC-ID: NO9 SNTU04 Batt. – CANUSA Operating Instructions Radio Transmitter PM NTU Page 2 / 16BE-PM_NTU-US-L.DOC [ Word 97 ] FL HBC-radiomatic, Inc. , Cincinnati , Ohio 45242 , USA 2000-08-16Information and specifications subject to change without notice. Radio Control System Manufactured by :HBC-radiomatic GmbH Haller Strasse 49 - 53 74564 Crailsheim • GERMANY Telephone :+49 ( 0 ) 79 51 – 3 93 - 0 Fax :+49 ( 0 ) 79 51 – 3 93 – 50 E-mail :[email protected] http://www.hbc-radiomatic.com Distributed by :HBC-radiomatic, Inc. 4480 Lake Forest Drive, Suite 306 Cincinnati, OH 45242, USA Telephone :( 513 ) – 7 33 – 49 00 Fax :( 513 ) – 7 33 – 49 03 HBC-radiomatic GmbH is not liable for any misprints or errors! – All rights reserved. ™HBC-radiomatic is a registered American trademark. ©2000 – 07 , HBC-radiomatic GmbH , 74564 Crailsheim , Germany No part of any software or of the present document may be reproduced in any manner whatsoever without the expressed written permission of HBC-radiomatic GmbH. Operating Instructions Radio Transmitter PM NTU BE-PM_NTU-US-L.DOC [ Word 97 ] FLPage 3 / 16 HBC-radiomatic, Inc. , Cincinnati , Ohio 45242 , USA Information and specifications subject to change without notice.2000-08-16 Radio Control System Table of Contents 1Description......................................................................................................4 2Safety Instructions..........................................................................................5 2.1Pictographs..........................................................................................5 2.2General Safety Instructions................................................................6 2.3Operator Safety Instructions..............................................................7 3Operating Instructions....................................................................................8 3.1Battery and Battery Charger..............................................................9 3.1.1FuB 10 AA Transmitter Battery..............................................................9 3.1.2FLG 102 Battery Charger........................................................................9 3.2Special Operating Modes (Optional)................................................10 3.2.1Scanner...................................................................................................10 3.2.2tele-teach-in Battery (TTB 10)...............................................................11 4Trouble-Shooting..........................................................................................13 5Maintenance..................................................................................................14 5.1In The Event of a Fault.....................................................................14 6Technical Data..............................................................................................15 6.1Dimensions of the PM NTU...............................................................16 Operating Instructions Radio Transmitter PM NTU Page 4 / 16BE-PM_NTU-US-L.DOC [ Word 97 ] FL HBC-radiomatic, Inc. , Cincinnati , Ohio 45242 , USA 2000-08-16Information and specifications subject to change without notice. Radio Control System 1Description The PM NTU transmitter is designed to transmit command instructions for controlling construction, industrial and mobile cranes, hoists and machines. Depending on the type and version selected, up to 32 digital or 8 analog + 24 digital control commands plus the integrated safety commands are available to the operator. A non-interchangeable system address ensures the functional safety of the radio telecontrol system when operating cranes or machines. This feature is particularly important when several cranes or machines are in use, for example in halls and shops. The system address is exclusively allocated to each HBC radio transmitter and its respective receiver. It is not possible to activate crane or machine functions using a radio system allocated to another crane or machine. The transmitter has general telecommunications approvals. It is not necessary to have or to apply for a license to operate the transmitter with the respective receiver. The transmitter broadcasts in either a 30 cm or 70 cm bandwidth. The transmitter is equipped with < 10 mW transmitting power. Operating the PM NTU transmitter using a different frequency range or transmitting power requires the approval of the competent regulative authorities for telecommunication. The radio system consists of the PM NTU transmitter, two rechargeable NiCd batteries, a battery charger and a receiver with antenna. The transmitter housing with integrated antenna is made of glass-fiber reinforced plastic. State of the art radio technology complying with the latest guidelines of the FCC and the use of highly developed microprocessor technology guarantees optimal operating safety, availability and longevity. The following radio receiver may be used in conjunction with the PM NTU transmitter: − FSE 722 B − FSE 735 − FSE 770 Note : The improper use, operation or deployment of the device renders the manufacturer guarantee void of any legal substance ! Operating Instructions Radio Transmitter PM NTU BE-PM_NTU-US-L.DOC [ Word 97 ] FLPage 5 / 16 HBC-radiomatic, Inc. , Cincinnati , Ohio 45242 , USA Information and specifications subject to change without notice.2000-08-16 Radio …
Text truncated - open the document above for the full version.
radiomatic ® radiobus ®® HBC- radiomatic GmbH HBC-radiomatic GmbH Postfach 1561 D-74555 Crailsheim!! Radio control systems for industrial applications Registered office: 71561 Crailsheim Registry court: Local court Crailsheim, HRB 652 Managing Directors Martin Brendel, Wolfgang Brendel VAT-Nr. DE 8117 27916 BW-Bank Crailsheim (BLZ 522 300 50) 826 05445 00 Deutsche Bank Aslen/Crailsheim (BLZ 613 700 86) 096 8511 Kreissparkasse Crailsheim (BLZ 622 500 30) 133 65 Postgirokonto Stuttgart (BLZ 600 100 70) 205 90-707 Postfach 1561 - D-74555 Crailsheim Hallerstrasse 49-53 - D-74564 Crailsheim Fon +49 (0) 7951/3 93-0 Fax +49 (0) 7951/3 93-50 http://www.radiomatic.com June 8, 2000 Attn: Reviewing Engineer Federal Communications Commision 7435 Oakland Mills Road Columbia, MD 21046 RE: CONFIDENTIALITY REQUEST FOR HBC-RADIOMATIC’S APPLICATION FOR GRANT OF EQUIPMENT AUTHORIZATION To Whom It May Concern: This letter serves as an official request for confidentiality under FCC Rule Section 0.459. We have requested that the schematic diagrams required to be submitted with this application be withheld from public review. Due to the competitive nature of our industry, a public viewing of these schematics could allow our competitors an unfair advantage in illegally reproducing our technology. Please contact me if there is any information you may need. Sincerely, Jason F. Looman Marketing and Sales Manager, NA HBC-radiomatic, GmbH Haller Strasse 49-53 D-74564 Crailsheim Deutschland
radiomatic ® radiobus ®® HBC- radiomatic GmbH HBC-radiomatic GmbH Postfach 1561 D-74555 Crailsheim!! Radio control systems for industrial applications Registered office: 71561 Crailsheim Registry court: Local court Crailsheim, HRB 652 Managing Directors Martin Brendel, Wolfgang Brendel VAT-Nr. DE 8117 27916 BW-Bank Crailsheim (BLZ 522 300 50) 826 05445 00 Deutsche Bank Aslen/Crailsheim (BLZ 613 700 86) 096 8511 Kreissparkasse Crailsheim (BLZ 622 500 30) 133 65 Postgirokonto Stuttgart (BLZ 600 100 70) 205 90-707 Postfach 1561 - D-74555 Crailsheim Hallerstrasse 49-53 - D-74564 Crailsheim Fon +49 (0) 7951/3 93-0 Fax +49 (0) 7951/3 93-50 http://www.radiomatic.com June 8, 2000 Attn: Reviewing Engineer Federal Communications Commision 7435 Oakland Mills Road Columbia, MD 21046 RE: LETTER OF AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize MET Laboratories, Inc. To act on our behalf in all matters relationg to aplication for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988,21 U.S.C.853(a). This agreement expires one year form the current date. Sincerely, Jason F. Looman Marketing and Sales Manager, NA HBC-radiomatic, GmbH Haller Strasse 49-53 D-74564 Crailsheim Deutschland
File: PM-NTU-von-unten.CDR [ CorelDRW 8.0 ] 27.07.2000 FL This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, & (2) This device must accept any interference received, including interference received that may cause undesired operation. HBC-radiomatic GmbH Tel.: +49(0)7951/393-0 Made in Germany HBC-Remote-Control made for PM Prod.Code: PMNTU Transmitter Ser.No.: 735- IP55 / Nema 4 U: 6V DC Frequency (MHz): 902,000918,000 Frequency Block: W4-FB001 Batt. – FCC ID:N09PMNTU4
Report of Equipment Authorization for the PMNTU Transmitter Certified under the FCC Rules contained in Title 47 of the CFR, Part 15, Subpart B 15.249 for 902 - 928 MHz Operation MET REPORT EMI1308F August 16, 2000 PREPARED FOR: HBC-Radiomatic Haller Strasse 49-53 D-74564 Crailsheim Germany PREPARED BY: MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, Maryland 21230-3432 August 16, 2000 HBC-Radiomatic Haller Strasse 49-53 D-74564 Crailsheim Attention:Juergen Schneider Regarding: Certification of the PMNTU Transmitter under Part 15, Subpart B of the FCC Rules as a Transmitter MET Report: EMI1308F Dear Juergen Schneider: Enclosed is a report of of compliance in accordance with FCC Part 15, Subpart B of Title 47 of the Code of Federal Regulations, Section 15.209 and 15.249 for the PMNTU Transmitter. Based on these results, MET Laboratories, Inc. certifies that the PMNTU Transmitter, tested as configured, meets the requirements and interference limitations contained in Section 15.209 and 15.249 under Part 15, Subpart B of Title 47 of the Code of Federal Regulations. If you have any questions concerning this report or your responsibilities as a manufacturer of Certified equipment, please contact us at your convenience. Thank you for using MET's testing services. Sincerely, MET Laboratories, Inc. Tony Permsombut Project Engineer August 16, 2000- 2 -EMI1308F Report of Equipment Authorization for the PMNTU Transmitter Certified under the FCC Rules contained in Title 47 of the CFR, Part 15, Subpart B 15.249 for 902-928 MHz Operation MET REPORT EMI1308F August 16, 2000 PREPARED FOR: HBC-Radiomatic Haller Strasse 49-53 D-74564 Crailsheim Germany PREPARED BY: MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, Maryland 21230-3432 Test Engineer:________________________________ Tony Permsombut Report Writer:________________________________ Joanna Kolasinski Reviewed by:________________________________ Chris Harvey EMI Laboratory Director August 16, 2000- 3 -EMI1308F TABLE OF CONTENTS COVER LETTER LEGAL STATEMENT....................................................................4 EXHIBIT 1.............................................................................5 MANUFACTURER & PRODUCT INFORMATION.......................................6 ENGINEERING STATEMENT......................................................6 EXHIBIT 2.............................................................................7 INTRODUCTION.................................................................8 TEST SITE......................................................................8 MEASUREMENT PROCEDURES....................................................8 INSTRUMENTATION.............................................................8 TEST CONFIGURATION..........................................................10 PHOTOGRAPH OF RADIATED EMISSIONS..........................................12 EXHIBIT 3............................................................................13 Radiated Emissions Low Oscillator...................................................14 Radiated Emissions Mid-Oscillator...................................................16 Radiated Emissions High Oscillator...................................................18 August 16, 2000- 4 -EMI1308F LEGAL STATEMENT While use of the National Voluntary Laboratory Accreditation Program (NVLAP) letters or the NVLAP Logo in this report reflects the MET Accreditation under the NVLAP Program, these letters, logo, or Statements do not claim product endorsement by NVLAP or any Agency of the U.S. Government. Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. August 16, 2000- 5 -EMI1308F EXHIBIT 1 MANUFACTURER & PRODUCT INFORMATION ENGINEERING STATEMENT August 16, 2000- 6 -EMI1308F MANUFACTURER & PRODUCT INFORMATION TYPE OF AUTHORIZATION: Certification for Transmitter FCC IDENTIFIER:NO9PMNTU4 APPLICABLE FCC RULES:2.907; 2.103 to 2.1041; 15.209 ; 15.249 CLIENT:HBC-Radiomatic Haller Strasse 49-53 D-74564 Crailsheim Germany EQUIPMENT:PMNTU Transmitter TESTING DATE(S):3/10/00 ENGINEERING STATEMENT I ATTEST: the measurements shown in this report were made in accordance with the procedures indicated, and that the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. I FURTHER ATTEST: on the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 15 of the FCC Rules under normal use and maintenance. ______________________ Tony Permsombut Project Engineer August 16, 2000- 7 -EMI1308F EXHIBIT 2 INTRODUCTION TEST SITE MEASUREMENT PROCEDURES INSTRUMENTATION TEST CONFIGURATION MODIFICATIONS STATEMENT PHOTOGRAPHS August 16, 2000- 8 -EMI1308F INTRODUCTION An EMI evaluation to determine compliance of the PMNTU Transmitter with the requirements of Part 15, Subpart B was conducted. (All references are to the most current version of Title 47 of the Code of Federal Regulations in effect). In accordance with §2.955(a)(3), the following data is presented in support of the certification of the PMNTU Transmitter. HBC-Radiomatic should retain a copy of this document should be kept on file for at least two years after the manufacturing of the PMNTU Transmitter has been permanently discontinued, as per §2.955(b). TEST SITE All testing was conducted at MET Laboratories, Inc., 914 West Patapsco Avenue, Baltimore, Maryland 21230- 3432. Radiated emissions measurements were performed on an open area test site (OATS). In accordance with §2.948(a)(3), a complete site description is contained at MET Laboratories. In accordance with §2.948(d), MET Laboratories has been accredited by the National Voluntary Laboratory Accreditation Program (Lab Code: 100273-0) MEASUREMENT PROCEDURES As required by §15.20…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.075 MHz - 918.128 MHz | - |

Inertial Measurement Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DECT ULE Radio Module
Equipment Class
PUB - Part 15 Unlicensed PCS Base Station
Remote Control technos A
Equipment Class
JAD - Part 15 Class A Digital Device
RF Module 902-928 MHz frequency hopping
Equipment Class
DTS - Digital Transmission System
Bluetooth Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter