Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 16, 2007
Application Purpose
Original Equipment
Date of Application
Apr 16, 2007
Equipment Note
900MHz Wireless Transmitter
Frequency Range
912.40000000 - 913.60000000
Company
Atom Industrial Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (External) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (External)

ID Label/Location Info

This is the property of Atom Industrial Limited. Copy without prior permission is strictly prohibited. Atom Industrial Limited AW872 (Transmitter) Base FCC Statement / Rating Label / Date Code

Internal Photos

INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal) INTERTEK TESTING SERVICE Report No.: 0704631 FCC ID: NOY-AW872TX Equipment Photographs Model : AW872 (Internal)

Operational Description

                                                      !"  #$%%&       %& '  & (            )$* + ,)-(% + .   /      +)$*,   ,                   +                    ,  +    )+    /     + . $        #$%%&   + .   01    +            +  %2"34     ,&   2, ',    .                !56/ .   #$%%&    +     "02!0("  '56/ 7 )+  + .  Antenna Configuration Antenna 8.5cmΦ1mm PCBboard FCC ID: NOY-AW872TX Preliminary GP214D 1.4GHz DUAL PLL DESCRIPTION The GP214D is a dual frequency synthesizer designed for RF operation up to 1.4GHz. The device contains prescalers, programmable reference, and feedback frequency dividers, phase detectors, and charge pumps necessary for the precision control of dual VCO loops. Data transfer is made via a simple serial data interface. The GP214D is fabricated using advanced CMOS process and available in a 16-pin TSSOP plastic package with 0.65mm pitch . FEATURES ▪ Two systems for transmitter and receiver 16-Pin TSSOP ▪ 2.4V to 5.0V operation (200MHz to 1.4GHz) ▪ Low current consumption 8.5mA @ 3.0V (Typ.) ▪ Modulus prescaler, 64 / 66 ▪ Selectable charge pump current ± 0.2mA, ± 0.4mA, ± 0.8mA, ± 1.6mA APPLICATIONS ▪ Portable wireless communications (PCS, cordless) ▪ Other wireless communication systems BLOCK DIAGRAM Version 1.1 (Jan, 2005) 1GAINTECH INCORPORATED Preliminary GP214D 1.4GHz DUAL PLL Version 1.1 (Jan, 2005) 2GAINTECH INCORPORATED PIN DESCRIPTION Pin No. Symbol Function Description I / O 1 Fin1 RF input, channel 1. I 2, 15 Vcc Power supply. Two pins are connected each other. - 3 CP1 Charge pump output, channel 1. Charge pump current is selected by the input serial data. O 4, 13 GND Ground. Two pins are connected. - 5 LD Output of lock detection. It is the open drain output. O 6 CK Clock input. 7 DATA Serial data input. 8 EN Input of enable signal. Serial data interface. I 9 BO Output of buffer amplifier. The local signal passes through the buffer amplifier. O 10 OSCO Oscillator output. O 11 OSCI PLL reference input. Typically connected to a TCXO output. I 12 SW Switchover terminal to control time constant of loop filter. It is the open drain output. When switched off, it’s normal output. O 14 CP2 Charge pump output, channel 2. O 16 Fin2 RF input, channel 2. I ABSOLUTE MAXIMUM RATINGS Parameters Symbol Value Unit Power supply voltage Vcc 5.5 V Operating temperature T OPR -30 to +85 °C Storage temperature T STG -35 to +150 °C ESD (Human body model) 2000 V Note: This device is ESD sensitive. Appropriate ESD protection is required for device handling and assembly. Preliminary GP214D 1.4GHz DUAL PLL Version 1.1 (Jan, 2005) 3GAINTECH INCORPORATED ELECTRICAL CHARACTERISTICS (Unless otherwise specified, Vcc = 3.0V, Ta = 25°C) Characteristic Symbol Test Condition Min. Typ. Max.Unit Operating power supply voltage Vcc Fin1= Fin2= 200MHz~1.4GHz 2.4 3.0 5.0 V Operating current consumption Icc Fin1= Fin2= 800MHz/ -5dBm input 7.0 8.5 14.5mA Standby current I SB Standby mode - 0 80 μA Fin operating frequency Fin Fin1=Fin2= -5dBm 200 - 1400MHz Vcc = 2.4V -15 - 10 Vcc = 3.0V -15 - 10 Fin1= Fin2= 200~1200MHz Vcc = 5.0V -15 - 10 Vcc = 2.4V -15 - 0 Vcc = 3.0V -15 - 0 Fin input sensitivity Fin Fin1= Fin2= 1200~1400MHz Vcc = 5.0V -15 - 0 dBm OSCI operating frequency F OSC V Fin = 0dBm, sinewave 4 - 40 MHz F OSC = 4~10MHz Vcc= 2.4~3.7V -10 0 10 OSCI input voltage V OSC F OSC = 10~40MHz Vcc= 2.4~5.0V -15 0 20 dBm Serial data input high voltage (CK, DATA, EN) V IH Vcc= 1.7 to 5.0V Vcc – 0.2 Vcc - V Serial data input low voltage (CK, DATA, EN) V IL Vcc= 1.7 to 5.0V - 0 0.2 V I CP1 CP1= 0, CP2= 0 (V CP = 1/2 Vcc) - 15% ± 1.6 + 15% I CP2 CP1= 1, CP2= 0 (V CP = 1/2 Vcc) - 15% ± 0.2 + 15% I CP3 CP1= 0, CP2= 1 (V CP = 1/2 Vcc) - 15% ± 0.4 +15% Charge pump output current I CP4 CP1= 1, CP2= 1 (V CP = 1/2 Vcc) - 15% ± 0.8 +15% mA Charge pump leakage I CPL Standby mode (V CP = 1/2 Vcc) -1 - 1 μA Preliminary GP214D 1.4GHz DUAL PLL Version 1.1 (Jan, 2005) 4GAINTECH INCORPORATED PROGRAMMING DESCRIPTION SERIAL DATA INPUT AND TIMING The programmable functions are accessed through the MCU serial data interface. The interface includes clock (CK, pin 6), data (DATA, pin 7) and enable signal (EN, pin 8). Serial data controls programmable reference counter and programmable counters in channel 1 and channel 2. The serial data is clocked in on the rising edge of clock and transferred into the shift register composed of 17-bit data field and 2-bit control field. When EN is high, stored data is latched. Data is entered LSB first. 0.2us 0.2us LSB 0.1us 0.1us GC2 N17(R12) N2(R2) N1(R1) GC1 0.2us 0.2us 0.1us MSB 0.2us CK DATA EN GROUP CODE AND LOCATION The data stored in the shift register is loaded into one of four appropriate latches depending on the state of group code (control bits) listed below. Control Bits GC2(MSB-1) GC1(MSB) Data Location 0 0 Control Latch 1 0 Ch 1 N Latch 0 1 Ch 2 N Latch 1 1 OSC R Latch Preliminary GP214D 1.4GHz DUAL PLL Version 1.1 (Jan, 2005) 5GAINTECH INCORPORATED OPTIONAL CONTROL The control register enables various functions shown in the table below. LSB Channel 1 Channel 2 MSB Bit1 Bit2 Bit3 Bit4 Bit5 Bit6…

Text truncated - open the document above for the full version.

Schematics

                                                                   !" # $ #%&  !"          !  " #!  $%   !    #&   &  !    '   !    ( !!  &    $%    $%    (   &  ! (      ! )!   ( ! # &   # &           ( !   " !' $'   !'   !   # " ) #& " ) (        !         ( !    " &     !      (       !  '   &  !   # " ) # " ) (           (     "     ! !  !  !  ( !       (   (     !' ( !   ( !    (  !  ! & !  !  ( !&     !   !&  !!  !    '! ' !  (      !   !&  !&      '! ' *++* *++*     * & *  +*' (                                                                  !" $  !"       #"! !             !      ! !    % ',         & !   # "! !           # "!   !  % %   &  (   (     &    &     & !   &                    (        !    ! !  !    !!  !          )   ! & !  !  '  !   ! +-.   )     "     )    +-.    ! &       !  ) !  ! &         &  !  !  !   +*' *++*   *++*   * * & ( 

Test Report

− The evaluation data of the report will be kept for 3 years from the date of issuance. − This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Atom Industrial Limited Application For Certification (FCC ID: NOY-AW872TX) Transmitter 07046311 TC/el April 02, 2007 INTERTEK TESTING SERVICES FCC ID: NOY-AW872TX i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual EXHIBIT 8: Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: NOY-AW872TX ii MEASUREMENT / TECHNICAL REPORT Atom Industrial Limited − MODEL: AW872 FCC ID: NOY-AW872TX April 02, 2007 This report concerns (check one:) Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart C for intentional radiator − the new 47 CFR [04-05-05 Edition] provision. Report prepared by: Ho Wai Kin, Ben Intertek Testing Services Hong Kong Ltd. 2/F., Garment Center, 576 Castle Peak Road, Kowloon, Hong Kong. Phone: 852-2173-8505 Fax: 852-2371-0914 INTERTEK TESTING SERVICES FCC ID: NOY-AW872TX iii Table of Contents 1.0 General Description......................................................................................... 2 1.1 Product Description................................................................................... 2 1.2 Related Submittal(s) Grants ...................................................................... 2 1.3 Test Methodology...................................................................................... 3 1.4 Test Facility ............................................................................................... 3 2.0 System Test Configuration ............................................................................. 5 2.1 Justification ............................................................................................... 5 2.2 EUT Exercising Software .......................................................................... 5 2.3 Special Accessories .................................................................................. 5 2.4 Equipment Modification............................................................................. 6 2.5 Measurement Uncertainty ......................................................................... 6 2.6 Support Equipment List and Description ................................................... 6 3.0 Emission Results ............................................................................................. 8 3.1 Field Strength Calculation ......................................................................... 9 3.2 Radiated Emission Configuration Photograph ........................................ 11 3.3 Radiated Emission Data.......................................................................... 12 3.4 Conducted Emission Configuration Photograph...................................... 15 3.5 Conducted Emission Data....................................................................... 16 4.0 Equipment Photographs ............................................................................... 18 5.0 Product Labelling .......................................................................................... 20 6.0 Technical Specifications ............................................................................... 22 7.0 Instruction Manual ......................................................................................... 24 8.0 Miscellaneous Information ........................................................................... 26 8.1 Radiated Emission on the Bandedge....................................................... 27 8.2 Discussion of Pulse Desensitization........................................................ 28 8.3 Calculation of Average Factor ................................................................. 29 8.4 Emissions Test Procedures .................................................................... 30 INTERTEK TESTING SERVICES FCC ID: NOY-AW872TX iv List of attached file Exhibit Type File Description Filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Radiated Emission radiated photos.pdf Test Setup Photo Conducted Emission conducted photos.pdf Test Report Conducted Emission Test Result conducted.pdf Test Report Emission Plot bw.pdf External Photo External Photo external photos.pdf Internal Photo Internal Photo internal photos.pdf Block Diagram Block Diagram block.pdf Schem…

Text truncated - open the document above for the full version.

Test Report

Report No.: 0704631 Transmit mode AC Mains Ctrl No.: PAGE 1 Tested By:Hong, Report No.:0704631 Scan Settings (1 Range) |--------- Frequencies -----------||----------- Receiver Settings ------------| Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150k 30M 5k 10k PK+AV 10ms AUTO LN OFF 60dB Final Measurement: x QP / + AV Meas Time: 1 s Subranges: 16 Acc Margin: 20dB Transducer No. Start Stop Name 2 1 9k 30M EW0699 12 9k 30M EW0192 0 10 20 30 40 50 60 70 80 90 dBuV 100 0.15 MHz 30 110 F15Q F15A Report No.: 0704631 Transmit mode AC Mains Ctrl No.: Tested By:Hong, Report No.:0704631 Scan Settings (1 Range) |--------- Frequencies -----------||----------- Receiver Settings ------------| Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150k 30M 5k 10k PK+AV 10ms AUTO LN OFF 60dB Final Measurement Results: no Results

Test Setup Photos

INTERTEK TESTING SERVICE Report No: 0704631 Configuration Photographs Worst-Case Radiated Emissions (Front View) Model : AW872 Fig.1 FCC ID: NOY-AW872TX INTERTEK TESTING SERVICE Report No: 0704631 Configuration Photographs Worst-Case Radiated Emissions (Back View) Model : AW872 Fig.2 FCC ID: NOY-AW872TX

Test Setup Photos

INTERTEK TESTING SERVICE Report No: 0704631 FCC ID: NOY-AW872TX i Configuration Photographs Worst-Case Line-Conducted Emissions (Front View) Model : AW872 INTERTEK TESTING SERVICE Report No: 0704631 FCC ID: NOY-AW872TX ii Configuration Photographs Worst-Case Line-Conducted Emissions (Back View) Model : AW872 INTERTEK TESTING SERVICE Report No: 0704631 FCC ID: NOY-AW872TX iii Configuration Photographs Worst-Case Line-Conducted Emissions (Side View) Model : AW872

Contact Information

Applicant

Carol Chan(Senior Marketing Executive)
[email protected](852) 2707-0098Fax: (852) 2798-7234

Technical Contact

Intertek Testing Services Hong Kong Ltd.Ben Ho
[email protected](852) 2173-8505

Flat 5D, 5/F., Garment Centre, · Kowloon · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Ben Ho
[email protected](852) 2173-8505

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
115C912.4 MHz - 913.6 MHz-

Other Applications from Atom Industrial Limited

900MHz Outdoor Speakers RCA822C - FCC ID NOY-RCA822CTX - Atom Industrial Limited
NOY-RCA822CTX

900MHz Outdoor Speakers RCA822C

Apr 11, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
900MHz Outdoor Speakers RCA822C - FCC ID NOY-RCA822CRX - Atom Industrial Limited
NOY-RCA822CRX

900MHz Outdoor Speakers RCA822C

Apr 08, 2010

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
900MHz Outdoor Speakers AW828 - FCC ID NOY-AW828RX - Atom Industrial Limited
NOY-AW828RX

900MHz Outdoor Speakers AW828

Apr 07, 2010

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
900MHz Outdoor Speakers AW827 - FCC ID NOY-AW827RX - Atom Industrial Limited
NOY-AW827RX

900MHz Outdoor Speakers AW827

Apr 07, 2010

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Headphone - FCC ID NOY-AWD204RX - Atom Industrial Limited
NOY-AWD204RX

Wireless Headphone

Dec 13, 2009

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter