FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. In Tech Electronics Ltd/
  3. NV6PR900DX

NV6PR900DXGeneral Mobile Radio Service

In Tech Electronics Ltd
General Mobile Radio Service - FCC ID NV6PR900DX - In Tech Electronics Ltd
Click to zoom

Application Details

Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Jan 24, 2002
Application Purpose
Original Equipment
Date of Application
Oct 30, 2001
Equipment Note
General Mobile Radio Service
Frequency Range
462.55000000 - 462.72500000
Company
In Tech Electronics Ltd
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗
↗

RF Exposure Info

↗
↗

Schematics

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Test SetupFCCID : NV6PR900DX External Photo -front External Photo - rear

Internal Photos

Test SetupFCCID : NV6PR900DX Internal Photo – 1 Internal Photo – 2 Test SetupFCCID : NV6PR900DX Internal Photo – 3 Internal Photo – 4

RF Exposure Info

TEST REPORT Your Ref:Date: 18 Oct 2001 Our Ref: EMC/R/02258Page: 1 of 36 DID: 7729722Fax: 7776409 NOTE: This Report is not a Certificate of Quality. It is issued subject to the “ Terms and Conditions Governing Technical Services” set out in the “Request for Technical Services” form. The terms and conditions governing the issue of this report are set out overleaf. FORMAL REPORT ON TESTING IN ACCORDANCE WITH SAR (Specific Absorption Rate) Requirements using guidelines established in : FCC OET Bulletin 65 - Supplement C (Edition 97-01) OF A GMRS [ Model : PR900DX ] TEST FACILITYTelecoms & EMC, Testing Group, PSB Corporation Pte Ltd 1 Science Park Drive, Singapore 118221 PREPARED FORMr. Simon Lee IN-TECH ELECTRONICS LTD Unit 207-210, 2/F, Century Centre, 44-46 Hung To Road, Kwun Tong, Kowloon, HONG KONG Tel : (852) 2181 8899Fax : (852) 2191 7788 MANUFACTURERMr. Jeffrey Cheung IN-TECH ELECTRONICS LTD Huan Zhen Road, Shajing Bao An, Shenzhen, PRC Tel : (86) 755 7204 700Fax : (86) 755 7204 963 JOB NUMBER56S00374 TEST PERIOD13 Oct 2001 – 18 Oct 2001 PREPARED BYAPPROVED BY ____________________ Gary Ng Ah Chye Associate Engineer ____________________ Teo Swee Hoe Senior Engineer LA-2001-0212-A LA-2001-0213-F LA-2001-0214-E LA-2001-0215-B Your product quality and safety mark LA-2001-0216-G LA-2001-0217-G PSB Corporation Pte Ltd •• Testing Group •• 1 Science Park Drive Singapore 118221 •• Tel 65 772 9620 •• Fax 65 775 9725 •• Email [email protected] •• Website www.psbcorp.com “The results reported herein, unless otherwise stated have been performed in accordance with the laboratory’s terms of accreditation under the Singapore Accreditation Council – Singapore Laboratory Accreditation Scheme” PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 2 of 36 GMRS [ Model : PR900DX ] This Report is issued under the following conditions: 1. Results of the testing/calibration in the form of a report will be issued immediately after the service has been completed or terminated. 2. Unless otherwise requested, a reported shall contain only technical results. Analysis and interpretation of the results and professional opinion and recommendations expressed thereupon, if required, shall be clearly indicated and additional fee paid for, by the Client. 3. This report is not a Certificate of Quality. It only applies to the sample of the specific product/equipment given at the time of its testing/calibration. The results are not used to indicate or imply that they are application to other similar items. In addition, such results must not be used to indicate or imply that PSB Corporation approves, recommends or endorses the manufacturer, supplier or user of such product/equipment, or that PSB Corporation in any way “guarantees” the later performance of the product/equipment. 4. The sample/s mentioned in this report is/are submitted/supplied/manufactured by the Client, PSB Corporation therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture, consignment or any information supplied. 5. Additional copies of the report are available to the Client at an additional fee. No third party can obtain a copy of this report through PSB Corporation, unless the Client has authorised PSB Corporation in writing to do so. 6. PSB Corporation may at its sole discretion add to amend the conditions of the report at the time of issue of the report and such report and such additions or amendments shall be binding on the Client. 7. All copyright in the report shall remain with PSB Corporation and the Client shall, upon payment of PSB Corporation’s fees for the carrying out of the tests/calibrations, be granted a license to use or publish the report to the third parties subject to the terms and conditions herein, provided always that PSB Corporation may at its absolute discretion be entitled to impose such conditions on the license as it sees fit. 8. Nothing in this report shall be interpreted to mean that PSB Corporation has verified or ascertained any endorsement or marks from any testing authority or bodies that may be found on that sample. 9. This report shall not be reproduced wholly or in parts and no reference shall be made by the Client to PSB Corporation or to the report or results furnished by PSB Corporation in any advertisements or sales promotion. PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 3 of 36 GMRS [ Model : PR900DX ] TABLE OF CONTENTS TEST SUMMARY PRODUCT DESCRIPTION TEST RESULTS ANNEX A-TEST INSTRUMENTATION & GENERAL PROCEDURES ANNEX B-TEST PHOTOGRAPHS / DIAGRAMS Test Setup EUT Photographs ANNEX C-TISSUE SIMULANT DATA SHEETS ANNEX D-REFERENCES PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 4 of 36 GMRS [ Model : PR900DX ] TEST SUMMARY The product was tested in accordance with the following standards. Test Results Summary Test StandardsDescription Pass / Fail SAR Measurement (462MHz) For Face-Hand Held Location Pass [ • FCC OET Bulletin 65-1997 (Supplement C) • ANSI/IEEE Standard C95.1- 1993 SAR Measurement (462MHz) For Waist Position with Belt-Clip Location Pass [ [Based on Spatial Peak Uncontrolled exposure / General population Level : Brain : 1.60 W/Kg Body : 1.60 W/Kg Modifications No modifications were made. PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 5 of 36 GMRS [ Model : PR900DX ] PRODUCT DESCRIPTION Description :The Equipment Under Test (EUT) is a GMRS. Model Number : PR900DX Brand Name:COBRA Radio Type :Two Way Mobile Radio Serial Numbers :FCC#6 Frequency Band:462.5500Mhz – 462.7250MHz Operating Frequencies :462.5500Mhz – 462.7250MHz Rated Output Power : 2 Watts Clock / Oscillator Type :VCO Clock / Oscillator Frequency :462.5500Mhz – 462.7250MHz Antenna Type:Integrated Antenna Duty Cycle :50% Input Power :6V DC (UM-4 “AAA” size Battery x Qty 04) Accessories:1) Belt-Clip 2) Headset with Mic. and Speaker PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 6 of 36 GMRS [ Model : PR900DX ] TEST RESULTS The measureme…

Text truncated - open the document above for the full version.

RF Exposure Info

TEST REPORT Your Ref:Date: 18 Oct 2001 Our Ref: EMC/R/02258Page: 1 of 44 DID: 7729722Fax: 7776409 NOTE: This Report is not a Certificate of Quality. It is issued subject to the “ Terms and Conditions Governing Technical Services” set out in the “Request for Technical Services” form. The terms and conditions governing the issue of this report are set out overleaf. FORMAL REPORT ON TESTING IN ACCORDANCE WITH SAR (Specific Absorption Rate) Requirements using guidelines established in : FCC OET Bulletin 65 - Supplement C (Edition 97-01) OF A GMRS [ Model : PR900DX ] TEST FACILITYTelecoms & EMC, Testing Group, PSB Corporation Pte Ltd 1 Science Park Drive, Singapore 118221 PREPARED FORMr. Simon Lee IN-TECH ELECTRONICS LTD Unit 207-210, 2/F, Century Centre, 44-46 Hung To Road, Kwun Tong, Kowloon, HONG KONG Tel : (852) 2181 8899Fax : (852) 2191 7788 MANUFACTURERMr. Jeffrey Cheung IN-TECH ELECTRONICS LTD Huan Zhen Road, Shajing Bao An, Shenzhen, PRC Tel : (86) 755 7204 700Fax : (86) 755 7204 963 JOB NUMBER56S00374 TEST PERIOD13 Oct 2001 – 18 Oct 2001 PREPARED BYAPPROVED BY ____________________ Gary Ng Ah Chye Associate Engineer ____________________ Teo Swee Hoe Senior Engineer LA-2001-0212-A LA-2001-0213-F LA-2001-0214-E LA-2001-0215-B Your product quality and safety mark LA-2001-0216-G LA-2001-0217-G PSB Corporation Pte Ltd •• Testing Group •• 1 Science Park Drive Singapore 118221 •• Tel 65 772 9620 •• Fax 65 775 9725 •• Email [email protected] •• Website www.psbcorp.com “The results reported herein, unless otherwise stated have been performed in accordance with the laboratory’s terms of accreditation under the Singapore Accreditation Council – Singapore Laboratory Accreditation Scheme” PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 2 of 44 GMRS [ Model : PR900DX ] This Report is issued under the following conditions: 1. Results of the testing/calibration in the form of a report will be issued immediately after the service has been completed or terminated. 2. Unless otherwise requested, a reported shall contain only technical results. Analysis and interpretation of the results and professional opinion and recommendations expressed thereupon, if required, shall be clearly indicated and additional fee paid for, by the Client. 3. This report is not a Certificate of Quality. It only applies to the sample of the specific product/equipment given at the time of its testing/calibration. The results are not used to indicate or imply that they are application to other similar items. In addition, such results must not be used to indicate or imply that PSB Corporation approves, recommends or endorses the manufacturer, supplier or user of such product/equipment, or that PSB Corporation in any way “guarantees” the later performance of the product/equipment. 4. The sample/s mentioned in this report is/are submitted/supplied/manufactured by the Client, PSB Corporation therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture, consignment or any information supplied. 5. Additional copies of the report are available to the Client at an additional fee. No third party can obtain a copy of this report through PSB Corporation, unless the Client has authorised PSB Corporation in writing to do so. 6. PSB Corporation may at its sole discretion add to amend the conditions of the report at the time of issue of the report and such report and such additions or amendments shall be binding on the Client. 7. All copyright in the report shall remain with PSB Corporation and the Client shall, upon payment of PSB Corporation’s fees for the carrying out of the tests/calibrations, be granted a license to use or publish the report to the third parties subject to the terms and conditions herein, provided always that PSB Corporation may at its absolute discretion be entitled to impose such conditions on the license as it sees fit. 8. Nothing in this report shall be interpreted to mean that PSB Corporation has verified or ascertained any endorsement or marks from any testing authority or bodies that may be found on that sample. 9. This report shall not be reproduced wholly or in parts and no reference shall be made by the Client to PSB Corporation or to the report or results furnished by PSB Corporation in any advertisements or sales promotion. PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 3 of 44 GMRS [ Model : PR900DX ] TABLE OF CONTENTS TEST SUMMARY PRODUCT DESCRIPTION TEST RESULTS ANNEX A-TEST INSTRUMENTATION & GENERAL PROCEDURES ANNEX B-TEST PHOTOGRAPHS / DIAGRAMS Test Setup EUT Photographs ANNEX C-TISSUE SIMULANT DATA SHEETS ANNEX D-REFERENCES ANNEX E-SAR VERSUS DEPTH PLOTS ANNEX F-PROBE CALIBRATION PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 4 of 44 GMRS [ Model : PR900DX ] TEST SUMMARY The product was tested in accordance with the following standards. Test Results Summary Test StandardsDescription Pass / Fail SAR Measurement (462MHz) For Face-Hand Held Location Pass [ • FCC OET Bulletin 65-1997 (Supplement C) • ANSI/IEEE Standard C95.1- 1993 SAR Measurement (462MHz) For Waist Position with Belt-Clip Location Pass [ [Based on Spatial Peak Uncontrolled exposure / General population Level : Brain : 1.60 W/Kg Body : 1.60 W/Kg Modifications No modifications were made. PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 5 of 44 GMRS [ Model : PR900DX ] PRODUCT DESCRIPTION Description :The Equipment Under Test (EUT) is a GMRS. Model Number : PR900DX Brand Name:COBRA Radio Type :Two Way Mobile Radio Serial Numbers :FCC#6 Frequency Band:462.5500Mhz – 462.7250MHz Operating Frequencies :462.5500Mhz – 462.7250MHz Rated Output Power : 2 Watts Clock / Oscillator Type :VCO Clock / Oscillator Frequency :462.5500Mhz – 462.7250MHz Antenna Type:Integrated Antenna Duty Cycle :50% Input Power :6V DC (UM-4 “AAA” size Battery x Qty 04) Accessories:1) Belt-Clip 2) Headset with Mic. and Speaker PSSB Corporation EMC/R/02258IN-TECH ELECTRONICS LTDPage 6 …

Text truncated - open the document above for the full version.

Test Report

Modulation Frequency Response 0.00 1.00 2.00 3.00 20070012001700220027003200370042004700 Modulation Frequency (Hz) Frequency Deviation (kHz) Modulation Frequency Response 0.00 1.00 2.00 3.00 20070012001700220027003200370042004700 Modulation Frequency (Hz) Modulation Index (%)

Test Report

Modulation Limiting Characteristic 0.00 1.00 2.00 3.00 4.00 5.00 475767778797107117127137 Modulation Input (dBSPL) Frequency Deviation (kHz) 500Hz 1000Hz 2500Hz 3125Hz

Test Report

• The test results rep orted in this rep ort shall refer only to the samp le actually tested and shall not refer or be deemed a refer to bulk from which such a samp le may be said to have been obtained. • This rep ort shall not be rep roduced excep t in full without p rior authorization from Intertek Testing Services Hong Kong Limit ed • For Terms And Conditions of the services, it can be p rovided up on request. Inte rte k Te sting Se rvice s Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 In-Tech Electronics Ltd. Application For Certification (FCC ID: NV6PR900DX) WO# 0111744 WL/Agnes October 31, 2001 INTERTEK TESTING SERVICES FCC ID: NV6PR900DX i SUMMARY OF CONTENTS LIST OF EXHIBITS EXHIBIT 1 :General Description EXHIBIT 2 :System Test Configuration EXHIBIT 3 :RF Power Output EXHIBIT 4 :Modulation Characteristics EXHIBIT 5 :Occupied Bandwidth EXHIBIT 6 :Spurious Emission EXHIBIT 7 :Frequency Stability EXHIBIT 8 :Technical Specifications EXHIBIT 9 :Product Labelling EXHIBIT 10 :Photographs EXHIBIT 11: Instruction Manual EXHIBIT 12: Tune Up Procedure EXHIBIT 13: Part List EXHIBIT 14: RF Exposure Info INTERTEK TESTING SERVICES FCC ID: NV6PR900DX ii MEASUREMENT/TECHNICAL REPORT Application: In-Tech Electronics Ltd. Trade Name/Model No : Cobra PR900DX Date: October 31, 2001 This report concerns (check one:)Original Grant X Class II Change Equipment Type: General Mobile Radio Service, GMRS Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared by:Wilson Loke Intertek Testing Services 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Phone: 852-2173-8575 Fax:852-2745-8306 INTERTEK TESTING SERVICES FCC ID: NV6PR900DX iii Table of Contents 1.0 General Description ................................................................................................................ 2 1.1 Product Description ............................................................................................................2 1.2 Related Submittal(s) Grants ................................................................................................ 3 1.3 Test Methodology ...............................................................................................................3 1.4 Test Facility......................................................................................................................... 3 2.0 System Test Configuration ...................................................................................................... 5 2.1 Justification ......................................................................................................................... 5 2.2 EUT Exercising Software .................................................................................................... 6 2.3 Special Accessories .............................................................................................................6 2.4 Equipment Modification ..................................................................................................... 6 3.0 RF Output Power (Section 95.135) ........................................................................................ 8 3.1 RF Output Power at the antenna terminal........................................................................... 9 3.2 RF Output Power by Substitution Method ........................................................................ 11 4.0 Modulation Characteristics (Section 95.637(a)) ................................................................. 15 4.1 Modulation Frequiency Response ..................................................................................... 16 4.2 Modulation Limiting Characteristic................................................................................... 18 4.3 Audio Low Pass Filter Response....................................................................................... 20 5.0 Occupied Bandwidth (Section 95.633(a)) ........................................................................... 22 6.0 Spurious Emission (Section 95.635(b)) ................................................................................ 24 6.1 Spurious emission at the antenna terminal........................................................................ 25 6.2 Field Strength of Spurious Radiation ................................................................................ 28 7.0 Frequency Stability (Section 95.627) ................................................................................... 32 7.1 Frequency Tolerance ......................................................................................................... 33 7.2 Temperature Extreme Condition ....................................................................................... 35 7.3 Voltage Extreme Condition ............................................................................................... 37 8.0 Technical Specifications ........................................................................................................ 40 9.0 Product Labelling .................................................................................................................. 44 10.0 Equipment Photographs ..................................................................................................... 47 11.0 Instruction Mannal .............................................................................................................. 49 12.0 Tune Up Procedure ............................................................................................................. 51 13.0 Part List ................................................................................................................................5…

Text truncated - open the document above for the full version.

Test Report

Audio Low Pass Filter Response -70.0 -60.0 -50.0 -40.0 -30.0 -20.0 -10.0 0.0 110100 Frequency (kHz) dB relative to 1 kHz LPF Response TIA/EIA-603

Test Setup Photos

Test SetupFCCID : NV6PR900DX Radiated -front Radiated - rear

Contact Information

Applicant

Jacky Tsang(R & D Manager)
[email protected]852 2191-8899Fax: 852 2191-7788

Technical Contact

Intertek Testing Services Hong Kong LtdWilson Loke
[email protected](852) 21738575

2/F., Garment Centre · Kowloon · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong LtdWilson Loke
[email protected](852) 21738575

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195A462.55 MHz - 462.725 MHz2.1 W10K3F3E5.0000000000 ppm

Other Applications from In Tech Electronics Ltd

Bluetooth Extended Ear - FCC ID NV6-CS8144 - In Tech Electronics Ltd
NV6-CS8144

Bluetooth Extended Ear

Jan 11, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Stereo Hearing Enhancer - FCC ID NV6-CS8143 - In Tech Electronics Ltd
NV6-CS8143

Bluetooth Stereo Hearing Enhancer

Jan 10, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Headset - FCC ID NV6-CS8132 - In Tech Electronics Ltd
NV6-CS8132

Bluetooth Headset

Apr 10, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headset - FCC ID NV6-CS8131 - In Tech Electronics Ltd
NV6-CS8131

Bluetooth Headset

Oct 29, 2007

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headset - FCC ID NV6-CS8124 - In Tech Electronics Ltd
NV6-CS8124

Bluetooth Headset

Sep 12, 2007

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter