Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 51 EXHIBIT 5 User Manual Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 52 User Manual Attached is a preliminary copy of the Instruction Manual. The following information will be included in the next revision of the manual: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Lithonia Lighting could void the user's authority to operate the equipment. This manual will be provided to the end-user with each unit sold/leased in the United States.
Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 71 EXHIBIT 7 External Photographs Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 72 External Photographs
Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 31 EXHIBIT 3 ID Label & Location Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 32 Label Artwork / Location An engineering drawing of the label will be permanently affixed to the unit is shown below. Please note that due to the size of the device, the model number and trade name will be placed on a separate label. The Photo below shows the actual location. The label will be permanently affixed with indelible label.
Intertek Testing Services FCC ID: O4AELARTTEXHIBIT 31 EXHIBIT 3 ID Label & Location Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: O4AELARTT Grantee Code Applied For Lithonia Lighting FCCID: O4AELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: O4AELARTTEXHIBIT 32 Label Artwork / Location An engineering drawing of the label will be permanently affixed to the unit is shown below. Please note that due to the size of the device, the model number and trade name will be placed on a separate label. The Photo below shows the actual location. The label will be permanently affixed with indelible label. FCCID:O4AELARTT FCCID:O4AELARTT
Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 81 EXHIBIT 8 Internal Photographs Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 82 Internal Photographs PC Board Top and BottomView
Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 11 EXHIBIT 1 Operational Description / Letter of Agency Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 12 The Transmitter Model ELA RTT is part of an emergency lighting unit. The emergency lighting unit is equipped with a battery charger circuitry to detect AC power failures. The lighting unit provides 90 minutes of emergency lighting along a path of egress. The unit also contains a EF receiver circuit that controls a solid state switch. This solid state switch acts as a test switch for the unit. Pressing the button on the RF remote transmitter remotely activates this test switch via the RF receiver circuit. The SAW stabilized transmitter is based on the well-known Colpitts oscillator topology. This design is a single transistor type that performs both the function of the oscillation and transmission via a printed circuit coil, which serves as the transmitting antenna.
Intertek Testing Services EXHIBIT 2 Test Report Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT June 19, 2000 Report prepared by:Greg A. Thompson Intertek Testing Services 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 Phone: 678-775-2400 FAX: 678-775-2401 E-mail: [email protected] Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Services FCC ID: A794003 SUMMARY OF CONTENTS LIST OF EXHIBITS EXHIBIT 1:Operational Description / Letter of Agency EXHIBIT 2:Test Report EXHIBIT 3:ID Label & Location EXHIBIT 4:Block Diagram EXHIBIT 5:User Manual EXHIBIT 6:Test Setup Photographs EXHIBIT 7:External Photographs EXHIBIT 8:Internal Photographs EXHIBIT 9:Schematics Intertek Testing Services FCC ID: A794003Test Report i TABLE OF CONTENTS 1.0General Description.........................................................................................................1 1.1Product Description......................................................................................................................................1 1.2Related Submittals / Grants.........................................................................................................................1 1.3Test Methodology..........................................................................................................................................2 1.4Test Facility....................................................................................................................................................2 1.5Test Equipment List......................................................................................................................................3 2.0System Test Configuration..............................................................................................4 2.1Justification....................................................................................................................................................4 2.2EUT Exercising Software..............................................................................................................................4 2.3Special Accessories........................................................................................................................................4 2.4Equipment Modification...............................................................................................................................4 2.5Support Equipment List and Description....................................................................................................5 2.6Test Configuration Block Diagram..............................................................................................................5 3.0Emission Results...............................................................................................................6 3.1Field Strength Calculation............................................................................................................................6 3.2Radiated Emission Test Data........................................................................................................................7 3.3Line Conducted Emission Test Data............................................................................................................9 4.0Miscellaneous Information............................................................................................10 4.1Emissions Test Procedures.........................................................................................................................10 4.2Measured Bandwidth..................................................................................................................................11 4.3Calculation of Average Factor....................................................................................................................12 4.4Operating Characteristics and Holdover Time.........................................................................................13 Intertek Testing Services FCC ID: xxxELARTTTest Report 1 1.0General Description 1.1Product Description The Transmitter Model ELA RTT is part of an emergency lighting unit. The emergency lighting unit is equipped with a battery charger circuitry to detect AC power failures. The lighting unit provides 90 minutes of emergency lighting along a path of egress. The unit also contains a RF receiver circuit that controls a solid state switch. This solid state switch acts as a test switch for the unit. Pressing the button on the RF remote transmitter remotely activates this test switch via the RF receiver circuit. The SAW stabilized transmitter is based on the well-known Colpitts oscillator topology. This design is a single transistor type that performs both the function of the oscillation and transmission via a printed circuit coil, which serves as the transmitting antenna. 1.2Related Submittals There are no related submittals for this application. Intertek Testing Services FCC ID: xxxELARTTTest Report 2 1.3Test Methodology Both AC mains line-conducted and radiated emission measurements were performed according to the procedures in ANSI C63.4 (1992). All measurements were performed in Open Area Test Sites. The procedures for maximizing emissions as described in this report were followed. All radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the "Justification Section" of this Application. 1.4Test Facility The North site is located at 4317-A Park Drive in Norcross, Georgia. The site consists of a wooden enclosed structure with a steel ground plane. The site meets the characteristics of ANSI C63.4: 1992 and is on file with the FCC. Please reference the site filing number: 3140/SIT 1300F2, dated April 26, 1996. This Facility is accredited by NAVLAB program (NVLAB Code: 100409-0โฆ
Text truncated - open the document above for the full version.
Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 61 EXHIBIT 6 Test Setup Photographs Lithonia Lighting FCC Part 15 Application For Certification (Low Power Transmitter) Indura Emergency Lighting Unit Transmitter Models: ELA RTT FCC ID: xxxELARTT Grantee Code Applied For Lithonia Lighting FCCID: xxxELARTT Intertek Testing Service NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth GA 30096 678-775-2400 [email protected] Intertek Testing Services FCC ID: xxxELARTTEXHIBIT 62 Radiated Emission Configuration Photograph X View
1950 Evergreen Blvd., Suite 100 ยท Duluth, Georgia ยท United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 315 MHz - 315 MHz | - |