OGB84155RF Electronic Ballast

Shanghai Viva Home Improvement Co. Ltd.

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Mar 07, 2000
Application Purpose
Original Equipment
Date of Application
Feb 25, 2000
Equipment Note
RF Electronic Ballast
Frequency Range
0.03700000 - 0.04000000
Company
Shanghai Viva Home Improvement Co. Ltd.
Country
China

Documents & Files

Select a file to view

Cover Letter(s)

↗

ID Label/Location Info

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Safety & Compliance Consulting 29 Sweetman Lane West Milford, NJ 07480-2932 Tel/Fax (973) 728-5141 February 26, 2000 ACS-2000-F002 Federal Communications Commission Equipment Approval Services P.O. Box 358315 Pittsburgh, PA 15251-5315 Subject:Original Application for Certification of Consumer RF Lighting Device FCC ID: OGB84155 Electronic Ballast for Compact Fluorescent Lamp, Model 84155 Gentlemen: Enclosed, please find Shanghai Viva Home Improvement Co., Ltd.’s application for equipment authorization dated January 8, 2000. This consumer ISM device (RF Lamp) is in compliance with Part 18, Subpart C of the FCC Rules. The subject device is electronic ballast with in-line ferrite core that operates at 37-40 kHz switching frequency for use with compact fluorescent lamp (CFL). This RF ballast technical specifications include rated for 120V/60 Hz input, 55 watt rated CFL power, power factor 0.95, crest factor 1.5 and total harmonic distortion less than 10%. This EUT was tested with host CFL and in accordance with MP-5 to show compliance with FCC Part 18 limits. Should you have any questions or comments, please contact the undersigned. Thank you for your attention and cooperation in this matter. Sincerely yours, Richard Mullen Manager Safety & Compliance Consulting

Test Report

page 1 FCC ID: OGB84155 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-20F001 PPLICATION FOR CERTIFICATION On Behalf of Viva Home Improvement Co., Ltd. Electronic Ballast Model: 84155 Prepared for : Viva Home Improvement Co., Ltd. No.888, Zhangcao Rd, Caojing, Jinshan, Shanghai. Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China Tel: (0755)663-9496 Report Number • ACS-20F001 Date of Test • Dec. 30, 1999 / Jan. 04, 2000 Date of Report • Jan. 11, 2000 page 2 FCC ID: OGB84155 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-20F001 TABLE OF CONTENTS DescriptionPage Test Report Declaration 1.GENERAL INFORMATION.................................................................................................................. 4 1.1. Description of Device (EUT)............................................................................................................... 4 1.2. Test Facility....................................................................................................................................... 5 1.3. Test Uncertainty ................................................................................................................................. 5 2.POWER LINE CONDUCTED EMISSION TEST................................................................................ 6 2.1. Test Equipment................................................................................................................................... 6 Block Diagram of Test Setup....................................................................................................................... 6 2.3. Power Line Conducted Emission Limit ................................................................................................. 6 2.4. EUT Configuration on Test.................................................................................................................. 6 2.5. Operating Condition of EUT................................................................................................................ 7 2.6. Test Procedure ................................................................................................................................... 7 2.7. Power Line Conducted Emission Test Results....................................................................................... 8 3.RADIATED EMISSION TEST............................................................................................................... 9 3.1. Test Equipment................................................................................................................................... 9 3.2. Block Diagram of Test Setup............................................................................................................... 9 3.3. Radiation Limit ..................................................................................................................................10 3.4. EUT Configuration on Test.................................................................................................................10 3.5. Operating Condition of EUT...............................................................................................................10 3.6. Test Procedure ..................................................................................................................................10 3.7. Radiated Emission Test Results. .........................................................................................................11 4.PHOTOGRAPH..................................................................................................................................... 13 4.1. Photos of Power Line Conducted Emission Test...................................................................................13 4.2. Photos of Radiated Emission Test .......................................................................................................14 APPENDIX I (2 pages) APPENDIX II (3 pages) APPENDIX III (Photos of the EUT) (2 pages) page 3 FCC ID: OGB84155 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-20F001 TEST REPORT DECLARATION Applicant • Viva Home Improvement Co., Ltd. Manufacturer • Elec-Mart Co., Ltd EUT Description • Electronic Ballast (A) MODEL NO. : 84155 (B) SERIAL NO. : F2000010401 (C) POWER SUPPLY : AC 120V / 60Hz Test Procedure Used: FCC RULES AND REGULATIONS PART 18 SUBPART C RF LIGHTING DEVICES CONSUMER PRODUCT (1998) AND MP-5/1986 The device described above is tested by AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC 18 Part RF Lighting Device limits both radiated and conducted emissions. The test results are contained in this test report and AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. is assumed of full responsibility for the accuracy and completeness of these tests. Also, this report shows that the EUT is technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. Date of Test :Dec. 30, 1999 / Jan.04, 2000 page 4 FCC ID: OGB84155 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-20F001 1. GENERAL INFORMATION 1.1. Description of Device (EUT) Description • Electronic Ballast Model Number • 84155 Power Cord • Unshielded Detachable 1.5m Applicant • Viva Home Improvement Co., Ltd. No.888, Zhangcao Rd, Caojing, Jinshan, Shanghai. Manufacturer • Elec-Mart Co., Ltd. 4th, Ind. Zone, Paisha, Humen, Dongguan. Date of Test • Dec. 30, 1999 / Jan. 04, 2000 page 5 FCC ID: OGB84155 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-20F001 1.2. Test Facility Site Description 3m Anechoic Chamber:certificated by FCC, USA Aug. 18, 1997 3m & 10m Open Site:certificated by FCC, USA Feb. 13, 1998 EMC …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jason Chen(President)
86-21-5725-0333Fax: 86-21-5725-1999

Technical Contact

Safety & Compliance ConsultingRichard Mullen
[email protected](973) 728-5141

29 Sweetman Lane · West Milford, New Jersey · United States

Test Firm

Audix Technology (Shenzhen) Co.Smart Tsai
[email protected]86-755-663-9495Fax: 86-755-663-2877

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.037 MHz - 0.04 MHz-

Other Applications from Shanghai Viva Home Improvement Co. Ltd.

OGB84155D

RF Electronci Ballast With Dimmer

Mar 09, 2000

Equipment Class

8CC - Part 18 Consumer Device
RF Lamp - FCC ID OGBGSP - Shanghai Viva Home Improvement Co. Ltd.
OGBGSP

RF Lamp

May 06, 1999

Equipment Class

8CC - Part 18 Consumer Device