Application Details

Equipment Class
CSR - Scanning Receiver
Date of Grant
Oct 18, 1999
Application Purpose
Original Equipment
Date of Application
Aug 16, 1999
Frequency Range
406.00000000 - 512.00000000
Company
TAL Scan, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Block Diagram

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—
โ†—
โ†—
โ†—
โ†—

ID Label/Location Info

โ†—
โ†—

Internal Photos

โ†—
โ†—
โ†—

Parts List/Tune Up Info

โ†—
โ†—
โ†—

Schematics

โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

The following is in response to Correspondence Reference Number: 9354 FCC ID Label: FCC ID Label Location FCC ID OOF400QED01 Model: TAL400 FCC Label Locatio n

Test Report

Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1157EUT: TAL400Date: 18 June, 1999Page 1 of 18 EMC Measurement / Technical Report FCC Test Specification : FCC Part 15, Subpart B - Class B Certification for Scanning Receiver Manufacturer : Tal Scan Equipment Under Test : TAL400 Test Report No. : FR1157 Purchase Order No. : TAL060999A Document History RevisionIssue DateAffected Pages Description of ModificationsRevised By Approved By N/C18 June, 1999Initial release Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No. FR1157EUT: TAL400Date: 06/01/01 Page 2 of 18 EMC Measurement / Technical Report Document No. FR1157 From Garwood Laboratories Inc. World Compliance Center Test for TAL SCAN TAL400 WRITTEN BYREVIEWED BYREVIEWED BY Arnulfo TapiaRobert LynchEd Nakauchi Arnulfo Tapia EMC Sr. Technician Robert Lynch Quality Manager Ed Nakauchi EMC Engineer NARTE, Certified Test PersonnelTest Dates Arnulfo TapiaJuly 13, 1999 Test Facility Address City, State, Zip Code Phone Fax Garwood Laboratories Inc. 565 Porter Way Placentia, CA 92870 (714) 572-2027 (714) 572-2725 This report may be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the equipment tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. government. Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No. FR1157EUT: TAL400Date: 06/01/01 Page 3 of 18 TABLE OF CONTENTS (This document contains a total of 18 pages [excluding] attachments.) MEASUREMENT / TECHNICAL REPORT SUMMARY .............................................................................................................4 1. GENERAL INFORMATION....................................................................................................................................................5 1.1 Product Description ..................................................................................................................................5 1.2 Related Submittal(s)/ Grant(s)...................................................................................................................6 1.3 Tested System Description .........................................................................................................................6 1.4 Test Methodology ......................................................................................................................................6 2. PRODUCT LABELING............................................................................................................................................................7 2.1 FCC ID Label ............................................................................................................................................7 2.2 Location of Label on the EUT ...................................................................................................................7 2.3 Information to the User .............................................................................................................................7 3. SYSTEM TEST CONFIGURATION ........................................................................................................................................8 3.1 Justification ...............................................................................................................................................8 3.2 EUT Exercise Software/Equipment ...........................................................................................................8 3.3 Special Accessories....................................................................................................................................8 3.4 Equipment Modifications...........................................................................................................................8 3.5 Configuration of Tested System .................................................................................................................9 3.6 Details of Tested System ............................................................................................................................9 4. BLOCK DIAGRAM(S) OF EUT............................................................................................................................................10 5. TEST MEASUREMENT PHOTOS ........................................................................................................................................11 6. TEST DATA...........................................................................................................................................................................12 6.1 Conducted Emissions Limits....................................................................................................................12 6.2 Summary Table for Highest Conducted Emissions Levels.......................................................................12 6.3 Radiated Emissions Limits.......................................................................................................................13 6.4 Summary Table for Highest Radiated Emissions Levels .........................................................................13 6.5 Field Strength Calculation ......................................................................................................................14 APPENDIX A - TEST EQUIPMENT USED ...................................................................................................................โ€ฆ

Text truncated - open the document above for the full version.

Test Report

Reply to Correspondence Reference Number: 10220 Applicant: TAL Scan, LLC FCC ID: OOF400QED01 731 Confirmation Number: EA95170 1. As per the manufacturer, the Scanner/Receiver Model TAL400 is incapable of readily being altered by the user. This means there are no simple components and/or semiconductor chips, which can be altered or added to the unit to receive transmission in the cell bands. In addition, the unit is incapable of converting digital cellular transmissions to analog voice audio. 2. When the radiated emission data was collected, the receiver was tuned to 29MHz at first then 174MHz and finally 512MHz. The radiated emission level was checked while at each tuned frequency, worst case data was submitted.

Contact Information

Applicant

David C Dominguez(President)
[email protected]949-858-4690Fax: 949-888-7521

Technical Contact

Garwood LaboratoriesArnie Tapia
[email protected]714-572-2027

565 Porter Way ยท Placentia, California ยท United States

Non-Technical Contact

TAL ScanDavid Dominguez
[email protected]714-762-5155

Test Firm

Garwood Laboratories, Inc.Jason Armstrong
714-572-2027Fax: 714-572-2025

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
315B406 MHz - 512 MHz-%