Power Measurement Adapter
Frequency Range
2405.00000000 - 2480.00000000
Company
GeneTel Systems, Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—
β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMC compliance Ltd. Page: 1 of 1 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 6. User manual 1 PMA(Power Measurement Adapter) Hardware Description GeneTel Systems, Inc. 2012-05-26 2 Contents 1. Hardware Description ........................................................................... 4 1.1 Introduction.................................................................................................................................................. 4 1.2 Overall System Configuration ............................................................................................................ 4 1.3 PMA Introduction ...................................................................................................................................... 5 1.3.1. Front View ........................................................................................................................................... 5 1.4 Block Description ..................................................................................................................................... 6 1.4.1. Overall Block ..................................................................................................................................... 6 1.4.3. BlueBird-XP206 ................................................................................................................................ 7 1.4.2 GT-ZBM(ZigBee) ................................................................................................................................ 8 1.4.3 SPS-PMA-ZBB-PS206 ..................................................................................................................... 9 1.5 Schematics ................................................................................................................................................ 10 1.5.1 BLUEBIRD-XP206 .......................................................................................................................... 10 1.5.2 SPS-PMA-ZBB-PS206 .................................................................................................................. 11 1.5.3 GT-ZBM ............................................................................................................................................... 12 1.6 Part List ....................................................................................................................................................... 13 1.6.1 BLUEBIRD-XP206 .......................................................................................................................... 13 1.6.2 SPS-PMA-ZBB-PS206 .................................................................................................................. 14 1.6.3 ZBM(ZigBee) ..................................................................................................................................... 15 1.7 Circuits Description .............................................................................................................................. 16 1.7.1 Power Supply ................................................................................................................................... 16 1.7.2 ZigBee .................................................................................................................................................. 17 3 1.7.3 MCU ...................................................................................................................................................... 18 1.7.4 Serial Flash EEPROM .................................................................................................................. 19 1.8 RF MODEM Specification................................................................................................................... 20 1.8.1 ZigBee .................................................................................................................................................. 20 1.8.2 ZigBee Antenna Specification and Characteristic .................................................... 22 2. How to setup PMA ............................................................................... 25 2.1 ZigBee .......................................................................................................................................................... 25 2.1.1. Zigbee Channel Setup ............................................................................................................... 25 4 1. Hardware Description 1.1 Introduction PMA (Power Measurement Adaptor) is a kind of smart plug that is connected to the outlet of home electricity AC220V to measure the power consumption through the plug. The measured statistics can be transferred to PCAP(Power Control Access Point) via ZigBee wireless protocol and stores the polled statistics into internal storage device until it was retrieved by the remote smart phone user. A registered user can retrieve the statistics or control the AC line connectivity by using smart phone application. A user can also directly access PMA to read real time power consumption information. . 1.2 Overall System Configuration Figure 1 Overall System Configuration 5 1.3 PMA Introduction 1.3.1. Front View Figure 2 PMA Front View No. Description β‘  LED(ZigBee Transmit Status, Active= LED ON β‘‘ AC 220V Connection Plug 1.3.2. Rear View 6 Figure 3 PMA Rear View 1.4 Block Description 1.4.1. Overall Block 7 Figure 4 Overall Block Configuration DC power required for PMA is DC 5.0V is converted from home electricity AC220 to DC +5.0V using AC/DC adaptor. The +5.0V is used for both BLUEBIRD-XP206 and SPS-PMA-ZBB-PS206 which are the composed of PMA. BLUEBIRD-XP206 is carrier board for SPS-PMA-ZBB-PS206 a…

Text truncated - open the document above for the full version.

Block Diagram

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMC compliance Ltd. Page: 1 of 1 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 4. Block Diagram 31 - 1 κ·Έλ¦Ό 1 BlueBird-XP206

External Photos

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 1 of 3 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 2 External photos of EUT - Front - Rear http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 2 of 3 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. - Top - Bottom http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 3 of 3 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. - Left - Right

ID Label/Location Info

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd. 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Label Location

Internal Photos

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 1 of 3 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 3 Internal photos of EUT - Main board top - Main board bottom http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 2 of 3 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. - Sub board top - Sub board bottom http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 3 of 3 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. - Module board top - Module board bottom

Operational Description

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMC compliance Ltd. Page: 1 of 1 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 9. Antenna specification 1 1.8.2 ZigBee Antenna Specification and Characteristic 2 ELECTRICAL Char.SPECIFICATIONSREMARK ModelAE-2450-38-SMT Frequency Range2400~2500[MHz] V.S.W.R2.0 : 1 Gain3.94 Β±0.5 [dBi] PolarizationsIsotropic Input Impedance50[Ω] Input Power1[W] MECHANICAL Char.SPECIFICATIONS Feed TypeSMT Size[W x H x D]8 x 3 x 1.6[mm]

Operational Description

3 - 1 PMA(Power Measurement Adapter) Operation Description GeneTel Systems, Inc002E 2012-07-23 3 - 2 1. PMA DC +5V power can be supplied by using AC220V to DC adapter. Using DC-DC convert on PMA, +5V is converted to +3.3V to supply power for all the devices on PMA including MSP430. 2. DC +5V is supplied to PS-PMA-PS206 module which ZigBee module is installed on it. PMA communicated with PCAP(Power Control Access Point, WiFi/Ethernet to ZigBee protocol converter) through ZigBee wireless protocol and might controller by remote registered user to block or unblock AC 220V electricity. It also can be used for the user to monitor AC input voltage and power consumption. In addition, the power consumption of electrical appliances plugged into the outlet by measuring the PS-PMA-ZBB-206 board ZigBee modules through the collection device, PCAP (Power Control Access Point: Power control wireless AP) using the ZigBee (2.4 GHz) communication protocol 3. Using a dedicated chip, MG2455 RadioPulse's ZigBee controller is designed to communicate with PCAP. The ZigBee It requires external Power 3.3V and on-chip voltage regulator converts 3.3V to 1.5V to supply power for 2.4GHz frequency circuit inside of MG2455 and external impedance matching circuit. The MG2455 use operational clock 16MHz and also use 32.768Kz for the real time clock. Radio signal which carries user information output in the air through impedance matching circuit and chip type antena on ZBM(ZigBee Module). 4. BLUEBIRD-XP206 board supply DC +5V power to ZBM carrier, SPS-PMA- ZBB-PS206 and gathers real-time data (RTC), Human detection sensor (PIR, ) data, AC input voltage and current consumption and stores gathered data into Storage device (Serial EEPROM). The stored data is polled by PCAP using ZigBee (2.4 GHz) protocol. Firmware for SPS-PMA-ZBB-PS206 board can be updated by using debugger port. 5. The main control unit (Main Control Unit: MSP430) accepts +3.3 V power supply and connected with both 16Mhz and 32.768KHz for internal circuits and real time operation. To measure AC voltage and current, AC voltage measurement circuit input to MSP430 through pin 6 and 7 and AC current measurement circuit Is input to pin 2 and 3. It is also connected to ZigBee commnication module using UART(Univeral Asynchronous Receiver and Transmitter) serial interface through pin 59 and 60. The module is used for the communication with PCAP through ZigBee 2.4GHz protocol. 6. Using the measured AC power voltage and current, power consumption can be calculated. The measured data is stored in the storage device through 3 - 3 SPI(Serial Peripheral Interface) through pin 6 and 5. Pin 6 is clock and pin 5 is data to be stored or retrieved from storage device.

Schematics

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMC compliance Ltd. Page: 1 of 1 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 5. Schematics Main board 55 44 33 22 11 D D C C B B A A D_GNDD_GND D_GND D_GND D_GND D_GND D_GND CN1 CN3 CN2 CN4 D_GND D_GND D_GND D_GND GT-PMA-ZBB V1.0ZigBee Base-board/PS206 MG_ISPMG_RESETn MG_UART1_RXD MG_UART1_TXD MG_UART0_RXDMG_UART0_TXDMG_PIR_INTnSPIDOSPICLKSPICSnSPIDI MG_LINK_LED SPICSn SPIDI SPICLKSPIDO 3.3V5V_IN 3.3V 5V_IN 3.3V 3.3V 3.3V D_GND D_GND D_GND 3.3V 3.3V 5V_IN 3.3V 3.3V 3.3V 3.3V MG_UART0_TXD MG_UART1_TXD MG_UART1_RXDMG_ISPMG_RESETn MG_UART0_RXD MG_ON MG_LINK_LED PIR_PWR_EN MG_LINK_LED MG_ON PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP101 GREEN HIVE ZIGBEE A3 12 Thursday, April 26, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP101 GREEN HIVE ZIGBEE A3 12 Thursday, April 26, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP101 GREEN HIVE ZIGBEE A3 12 Thursday, April 26, 2012 CN3CN-2CN3CN-2 12 CN2CN-2CN2CN-2 12 R1333KR1333K CN1CN-2CN1CN-2 12 R810KR810K C212.2uFC212.2uF C370.01uFC370.01uF C200.01uFC200.01uF R333KR333K C190.01uFC190.01uF R733KR733K U1U-SST25VF080BU1U-SST25VF080B CE 1 SO 2 WP 3 VSS 4 SI 5 SCK 6 HOLD 7 VDD 8 R30330-1608R30330-1608 R1133KR1133K R32 0 R32 0 CN4CN-6CN4CN-6 123456 * Basic chip component size Resistor Capacitor TANTAL CAP 1608(0603)3216 1608(0603) Jumper SMD TYPE :DIP TYPE : INDACTOR 1005 NOTE1 NOTE-ONE SIDE * Basic chip component size Resistor Capacitor TANTAL CAP 1608(0603)3216 1608(0603) Jumper SMD TYPE :DIP TYPE : INDACTOR 1005 NOTE1 NOTE-ONE SIDE LED1LED-2012LED1LED-2012 1 2 + C1810uF_tc3216 + C1810uF_tc3216 12 R133KR133K R533KR533K C172.2uFC172.2uF R2NC_1KR2NC_1K J1ZBMJ1ZBM ACH0 1 ACH1 2 ACH2 3 ACH3 4 MS2/ISP 5 RESETB 6 P1_7/GPO/P0AND/TRSW 7 P1_6/TRSWB 8 VCC1 9 GND1 10 P1_1/TXD1 11 P1_0/RXD1 12 P3_7/PWM3/CTS1/SPICSN 13 P3_6/PWM2/RTS1/SPICLK 14 P3_5/T1/CTS0/QUADYB/SPIDO 15 P3_4/T0/RST0/QUADYA/SPIDI 16 P3_3/INT1B 17 P3_2/INT0B 18 P3_1/TXD0/QUADXB 19 P3_0/RXD0/QUADXA 20 P0_0/I2SRX_DI 30 P0_1/I2SRX_LRCK 29 P0_2/I2SRX_BCLK 28 P0_3/I2SRX_MCLK 27 P0_4/I2STX_DO 26 P0_5/I2STX_LRCLK 25 P0_6/I2STX_BCLK 24 P0_7/I2STX_MCLK 23 VCC2 22 GND2 21 ANT 33 Q2 Q-R113N311D Q2 Q-R113N311D VDD 1 GND 2 CE_CE 3 NC 4 VOUT 5 R31 0 R31 0 55 44 33 22 11 D D C C B B A A GND DS D_GND VCC_IDMD_GND D_GND D_GND 5V_IN D_GND D_GND 3.3VD_GND VCC_IDM D_GND VCC_IDM D_GND D_GND D_GND VCC_IDM D_GND D_GND D_GND VCC_IDM D_GND VCC_IDM PIR_PWR_EN MG_PIR_INTn PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP101 GREENHIVE ZIGBEE A4 22 Thursday, April 26, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP101 GREENHIVE ZIGBEE A4 22 Thursday, April 26, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP101 GREENHIVE ZIGBEE A4 22 Thursday, April 26, 2012 R22100KR22100K RV1NC_10K_VRRV1NC_10K_VR C250.1uFC250.1uF R348KR348K C26470nFC26470nF C352.2uFC352.2uF Q4 Q-R113N311D Q4 Q-R113N311D VDD 1 GND 2 CE_CE 3 NC 4 VOUT 5 + C2410uF + C2410uF 12 R2910KR2910K C230.1uFC230.1uF R33 22KR33 22K R252.2MR252.2M Q5 RE03B Q5 RE03B 12 3 C270.1uFC270.1uF R2810KR2810K * Basic chip component size Resistor Capacitor TANTAL CAP 1608(0603)3216 1608(0603) Jumper SMD TYPE :DIP TYPE : NOTE2 NOTE-ONE SIDE * Basic chip component size Resistor Capacitor TANTAL CAP 1608(0603)3216 1608(0603) Jumper SMD TYPE :DIP TYPE : NOTE2 NOTE-ONE SIDE C320.01uFC320.01uF C33 0.1uFC33 0.1uF C34 2.2uFC34 2.2uF R3533KR3533K R27NC_1.5KR27NC_1.5K R1810KR1810K + C3610uF + C3610uF 12 U2PS206/SO8U2PS206/SO8 VDD1 1 OEN 7 ENVREG 14 VDD2 9 NPIRIN 12 PIRIN 11 SENS 6 REL 2 LED 3 ONTIME 5 VSS1 4 VSS2 13 NC1 8 NC2 10 Q3Q-MMBT2222Q3Q-MMBT2222 23 1 Sub board 55 44 33 22 11 D D C C B B A A BT_ON_A CTL_LED_A BT_TXD_ABT_RXD_A CTL_LED_ABT_ON_A BT_TXD_ABT_RXD_A DGND DGND+5VD BT_3.3VDGND DGND DGND+5VD BT_3.3VDGND BT_3.3V PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP206 Bluetooth A4 1 3 Wednesday, May 02, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP206 Bluetooth A4 1 3 Wednesday, May 02, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP206 Bluetooth A4 1 3 Wednesday, May 02, 2012 U7 R1131N331D VDD 1 GND 2 CE/CE 3 NC 4 VOUT 5 + C2110uF/10V (tantal 3216) 12 CN8 CN-2 12 C231uF/16V (2012) + C2010uF/10V (tantal 3216) 12 CN10 CN-2 12 R280J (1608) C221uF/16V (2012) R2910KJ (1608) U6 U-BC4_MX01 UART_TX 1 UART_RX 2 UART_CTS 3 UART_RTS 4 PCM_CLK 5 PCM_OUT 6 PCM_IN 7 PCM_SYNC 8 AIO0 9 AIO1 10 RESETB 11 VCC_3V3 12 GND1 13 GND2 14 USB_DN 15 SPI_CSB 16 SPI_MOSI 17 SPI_MISO 18 SPI_CLK 19 USB_DP 20 GND3 21 GND4 22 PIO0 23 PIO1 24 PIO2 25 PIO3 26 PIO4 27 PIO5 28 PIO6 29 PIO7 30 PIO8 31 PIO9 32 PIO10 33 PIO11 34 LED1BLUE 1 2 CN9 CN-2 12 R15 0RJ (1608)R14 0RJ (1608) R30330J (1608) 55 44 33 22 11 D D C C B B A A CSSH2728 CTL_LEDBT_ONMANUAL_SWRLY_CNTL_N BT_TXDBT_RXD TDOTDITMSTCKnRESET TDOTDITMSTCKnRESET RLY_CNTL_N nRESET MANUAL_SW BT_TXDBT_RXD CTL_LEDBT_ON +3.3V +3.3V AVCC AGND AC_L AC_N AGND AC_N +5V AGND AC_L AC_N GND +5V +3.3V +3.3V GND +5V +3.3V GND +3.3V +5V GND AGND AVCC +3.3V PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP206 BlueBird A3 1 3 Wednesday, May 02, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP206 BlueBird A3 1 3 Wednesday, May 02, 2012 PROJECT NAMESize Page Name Rev Date: Sheet of <Doc> XP206 BlueBird A3 1 3 Wednesday, May 02, 2012 R1910KJ (1608) C191uF/16V (2012) R160RJ (1608) U1 MSP430FE4272 P2.1_UCLK0_S24 44 P2.0_TA2_S25 45 P1.7_SOMI0_S26 46 P1.6_SIMO0_S27 47 P1.5_TACLK_ACLK_S28 48 P1.4_S29 49 P1.3_SVSOUT_S30 50 P1.2_TA1_S31 51 P1.1_TA0_MCLK 52 P1.0_TA0 53 P2.2_STE0 11 P2.5__URXD0 59 P2.4_UTXD0 60 P2.3_SVSIN 61 S0 12 S1 13 S2 14 S3 15 S4 16 S5 17 S6 18 S7 19 S8 20 S9 21 S10 22 S11 23 S12 24 S13 25 S14 26 S15 27 S16 28 S17 29 S18 30 S19 31 S20 32 S21 33 S22 34 S23 35 DVCC 1 AVCC 64 V1+ 6 V1 7 I1+ 2 I1 3 COM0 36 COM1 37 COM2 38 COM3 39 XIN 8 XOUT 9 T…

Text truncated - open the document above for the full version.

Test Report

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 1 of 35 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. FCC TEST REPORT Test report No:EMC- FCC- R0068 FCC ID:OSGPMA Type of Equipment:Power Metering Adaptor Model Name:PMA Applicant:GeneTel Systems, Inc. FCC Rule Part(s):FCC Part 15 Subpart C Section 15.203, Section 15.209 Section 15.207, Section 15.247 Frequency Range: 2 405 MHz ~ 2 480 MHz Test result:Complied The above equipment was tested by EMC compliance Testing Laboratory for compliance with the requirements of FCC Rules and Regulations. The results of testing in this report apply to the product/system which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Date of test: July 16, 2012 ~ July 19, 2012 Issued date: July 23, 2012 Tested by:Approved by:. LEE, CHANG WONKIM, CHANG MIN http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 2 of 35 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. [ Contents ] 1. Client information.................................................................................................. 3 2. Laboratory information........................................................................................... 4 3. Description of E.U.T................................................................................................ 5 3.1 Basic description................................................................................................ 5 3.2 General description............................................................................................ 5 3.3 Test frequency................................................................................................... 6 3.4 Test Voltage..................................................................................................... 6 4. Summary of test results............................................................................................ 7 4.1 Standards & results............................................................................................. 7 4.2 Uncertainty...................................................................................................... 7 5. Test results.......................................................................................................... 8 5.1 Antenna Requirement........................................................................................... 8 5.2 Maximum Peak Output Power................................................................................. 9 5.3 Peak Power Spectral Density..................................................................................13 5.4 6 dB Bandwidth...............................................................................................17 5.5 SPURIOUS EMISSION, BAND EDGE, AND RESTRICTED BANDS..................................22 5.6 Conducted Emission...........................................................................................31 5.7 RF Exposure...................................................................................................34 6. Test equipment used for test.................................................................................... 35 Appendix 1 Test setup photos Appendix 2 External photos of EUT Appendix 3 Internal photos of EUT Appendix 4 Block diagram Appendix 5 Schematics Appendix 6 User manual Appendix 7 Part list Appendix 8 Layout diagram Appendix 9 Antenna Specification http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 3 of 35 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. 1. Client information Applicant:GeneTel Systems, Inc. Address:518 Yongsan-Dong Yuseong-Gu Daejoen, Korea Telephone number:+82-42-335-3001 Facsimile number :+82-42-335-3003 Contact person:JONG-UK CHAE / [email protected] Manufacturer: GeneTel Systems, Inc. Address:518 Yongsan-Dong Yuseong-Gu Daejoen, Korea http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 4 of 35 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. 2. Laboratory information Address EMC Compliance Ltd. 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea Telephone Number: 82 31 336 9919 Facsimile Number: 82 31 336 4767 Certificate CBTL Testing Laboratory, KOLAS NO.: 231 FCC Filing No.: 508785 VCCI Registration No.: C-1713, R-1606, T-258 SITE MAP SUWON-CITY EMCComplianceLtd. http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 5 of 35 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. 3. Description of E.U.T. 3.1 Basic description Applicant :GeneTel Systems, Inc. Address of Applicant: 518 Yongsan-Dong Yuseong-Gu Daejoen, Korea Manufacturer:GeneTel Systems, Inc. Address of Manufacturer: 518 Yongsan-Dong Yuseong-Gu Daejoen, Korea Type of equipment:Power Metering Adaptor Basic Model:PMA Serial number:Proto Type 3.2 General description Model NamePower Metering Adaptor CommunicationIEEE 802.15.4 Frequency Range2 405 ~ 2 480 MHz Type of ModulationO-QPSK Channel capacity16 ch Antenna Gain3.94 dBi Type of AntennaChip ANTENNA Power supplyAC 120V / 60 Hz Oper…

Text truncated - open the document above for the full version.

Test Setup Photos

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 1 of 2 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Appendix 1 Test setup photos - Below 1 GHz - Above 1 GHz http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0068 EMCcomplianceLtd.Page: 2 of 2 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. - Below 30MHz

Contact Information

Applicant

JONG-UK CHAE(President)
[email protected]042-335-3000Fax: 042-335-3003

Test Firm

EMC Compliance Ltdchangmin kim
[email protected]82313369919Fax: 82313364767

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz500.00 Β΅W
Grant Notes
Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures.