FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Suzhou Sanex Electronics Co. Ltd./
  3. OUMSMX120

OUMSMX120Compact Fluorescent Lamp

Suzhou Sanex Electronics Co. Ltd.
Compact Fluorescent Lamp - FCC ID OUMSMX120 - Suzhou Sanex Electronics Co. Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Nov 14, 2001
Application Purpose
Original Equipment
Date of Application
Nov 14, 2001
Equipment Note
Compact Fluorescent Lamp
Frequency Range
0.04400000 - 0.04600000
Company
Suzhou Sanex Electronics Co. Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC ID: OUMSMX120 USER MANUAL APPLICATIONS Restaurants HotelsHomes Supermarkets OfficesStores PRECAUTIONS 1. Never use on a source voltage that fluctuates 6% above or 10% below the lamp s rated voltage.. 2. Never disassemble or modify – any changes could void the user s authority to operate this device. 3. Do not hold the glass tube while installing. 4. Not for use in totally enclosed fixtures 5. Risk of electric shock – do not use where directly exposed to water 6. This device is not intended for use with emergency exit fixtures or emergency exit lights. 7. This product could product interference when used near a TV, radio, wireless remote control or maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45 – 30MHz. Of interference should occur, move the lamp away from the appliance a distance of three feet or more, Or, Plug the lamp or the appliance into a different outlet. 8. To prevent burns, do not touch the bulb during operation or immediately after switching off. 9. Not for use with dimmers, electronic timer or photocell devices or occupancy sensor. 10. Never use in circumstance such as low or high temperature and high moisture. 11. Unsuitable for applications where the lamp must be turned on and off frequently. FEATURES Long life ¼ Power consumption compared with standard bulb ¼ Heat radiation compared with standard bulb Soft and brisk light Wide voltage range SANEX ELECTRONICS CO., LTD.

Block Diagram

FCC ID: OUMSMX120 Suzhou Sanex Electronics Co., Ltd. BLOCK DIAGRAM Rectifier Inverter Energy Saving Tube Low Frequency AC Supply (60Hz) DC Supply High Frequency AC Supply 0.044-0.046MHz

External Photos

FCC ID OUMSMX120 External Photograph

External Photos

FCC ID OUMSMX120 External Photograph

ID Label/Location Info

FCC ID: OUMSMX120 ID Label / Location Info FCC ID: OUMSMX120 FCC ID: OUMSMX120

Internal Photos

Page 1 of 6 FCC ID OUMSMX120 Internal Photographs (SMI series) Model SMI-9, Assemble figure SMI-9, Component side Page 2 of 6 FCC ID OUMSMX120 SMI-9, soldering side Model SMI-11, Assemble figure Page 3 of 6 FCC ID OUMSMX120 SMI-11, Component side SMI-11, soldering side Page 4 of 6 FCC ID OUMSMX120 Model SMI-13, Assemble figure SMI-13, Component side Page 5 of 6 FCC ID OUMSMX120 SMI-13, soldering side Model SMI-15, Assemble figure Page 6 of 6 FCC ID OUMSMX120 SMI-15, Component side SMI-15, soldering side

Internal Photos

Page 1 of 6 FCC ID OUMSMX120 Internal Photograph (SMR series) SMI-9 Assemble Figure SMI-9 Component side Page 2 of 6 FCC ID OUMSMX120 SMI-9 soldering side SMI-11 Assemble Figure Page 3 of 6 FCC ID OUMSMX120 SMI-11 Component side SMI-11 soldering side Page 4 of 6 FCC ID OUMSMX120 SMI-13 Assemble Figure SMI-13 Component side Page 5 of 6 FCC ID OUMSMX120 SMI-13 soldering side SMI-15 Assemble Figure Page 6 of 6 FCC ID OUMSMX120 SMI-15 Component side SMI-15 soldering side

Operational Description

FCC ID: OUMSMX120 TECHNICAL DESCRIPTION This is a kind of integral energy saving lamp that is composed of a piece of energy saving tube and electronic ballast. * RECTIFICATION Rectifier converts power supply from AC to DC and also it is a full wave bridge rectifier with large filter capacitor(s) to protect the circuit against line transients. It also attenuates any EMI (Electromagnetic Interference) noise generated by the high frequency source that feeds the tube. * INVERTER Inverter changes the DC supply into high frequency AC. It employs the half bridge- voltage fed topology for inverting. It consists of two transistors connected in series across the output of the rectifier circuit., A train of pulses is created for voltage and current by this inverter switch circuit. The power switch is controlled by a small staturable core transformer. * OUTPUT The energy saving tube is the load of output section. It is in series with a LC resonance circuit. It feeds back the high frequency through the control circuit to synchronize the inverter frequency. The LC resonance circuit provides the high voltage which strike the tube during startup. Once the tube are on, the LC resonance circuit will generated the tube working voltage which is less than the voltage of startup.

Schematics

FCC ID: OUMSMX120 BG1 BG2 C 2 C7 C 5 L2 Tube Blue Marked components in the schematic diagram above were those changed for different power output. The following was paramet er list of them. R1 C1 D2 D1 D3 D4 L1 D5 DB3/D6 C3 D8 R5 D7 R4 C4 R3 C6 RT B R2 FCC ID: OUMSMX120 DIFFERENCES BETWEEN MODELS SMI-9 SMI-11 SMI-13 SMI-15 TransistorBG1,BG2 13002 Vceo=400V Ic=1A 13002 Vceo=400V Ic=1A 13003 Vceo=400V Ic=1.5A 13003 Vceo=400V Ic=1.5A Capacitor C2 CD11 10 F DC200V105 CD11 15 F DC200V105 CD11 22 F DC200V105 CD11 22 F DC200V105 Capacitor C5 CL11 2n7 DC1000V105 CL11 2n7 DC1000V 105 CL11 3n3 DC1000V 105 CL11 3n9 DC1000V 105 Capacitor C7 CL11 1n5 DC1000V105 CL11 1n8 DC1000V 105 CL11 1n8 DC1000V 105 CL11 1n8 DC1000V 105 Inductor L2 SE16-2.3mH SE16-2.1mH SE16-2.3mH SE16-2.1mH Lamp Tube 9w Lamp 11w Lamp 13w Lamp 15w Lamp SMR-9 SMR-11 SMR-13 SMR-15 TransistorBG1,BG2 13002 Vceo=400V Ic=1A 13002 Vceo=400V Ic=1A 13003 Vceo=400V Ic=1.5A 13003 Vceo=400V Ic=1.5A Capacitor C2 CD11 10 F DC200V105 CD11 15 F DC200V105 CD11 22 F DC200V105 CD11 22 F DC200V105 Capacitor C5 CL11 2n7 DC1000V105 CL11 2n7 DC1000V 105 CL11 3n3 DC1000V 105 CL11 3n9 DC1000V 105 Capacitor C7 CL11 1n5 DC1000V105 CL11 1n8 DC1000V 105 CL11 1n8 DC1000V 105 CL11 1n8 DC1000V 105 Inductor L2 SE16-2.3mH SE16-2.1mH SE16-2.1mH SE16-1.9mH Lamp Tube 9w Lamp 11w Lamp 13w Lamp 15w Lamp

Test Report

Report no: JSH01*1066-001 Page 1 of 10 FCC ID OUMSMX120 Application for FCC Identifier On Behalf of Suzhou Sanex Electronics Co., Ltd. (FCC ID OUMSMX120) Summary The equipment comply with the requirements according to the following standard(s): 47CFR Part 18: Industrial, Scientific, and Medical Equipment FCC/OET MP-5 (1986): FCC Methods of Measurements of Radio Noise Emissions From Industrial, Scientific, and Medical Equipment ANSI C63.4 (2000): Interim Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz. Description The appliances were tested by Shanghai Institute of Process Automation Instr. and found compliance with relevant requirements described in FCC Part 18 RF Lighting Device. Test results are contained in this test report and Intertek Testing Services ETL SEMKO Shanghai Limited is assumed full responsibility for the accuracy and completeness of these measurements. The test report applies to tested samples only and shall not be reproduced in part without written approval of Intertek Testing Services ETL SEMKO Shanghai Limited. Date of Test: October 23, 2001 Date of Issue: November 7, 2001 Prepared by: Report Approved by: Steve li (Engineer) Ole Stiling (Chief Engineer) Report no: JSH01*1066-001 Page 2 of 10 FCC ID OUMSMX120 Description of Test Facility Name of Firm :Shanghai Institute of Process Automation Instr. Site Location:103 Cao Bao Road, Shanghai 200233, China Name of contact :Miss. Ying (first name) Wang (last name) Phone:86-21-64368180 ext. 574 Fax: 86-21-64847454 E-mail address :[email protected] FCC Registration number: 96504 Report no: JSH01*1066-001 Page 3 of 10 FCC ID OUMSMX120 CONTENTS Summary ........................................................................................................................................ 1 Description ...................................................................................................................................... 1 Description of Test Facility ........................................................................................................... 2 1.Applicant Information ................................................................................................................ 4 2.Information of Equipment Under Test (EUT) ......................................................................... 4 2.1 Identification of the EUT........................................................................................................ 4 2.2 Additional information about the EUT................................................................................... 4 2.3 Peripheral equipment............................................................................................................. 4 3. Conducted Powerline Measurement ........................................................................................ 5 3.1 Conduction Limit.................................................................................................................... 5 3.2 Instruments List ...................................................................................................................... 5 3.3 Test Setup ............................................................................................................................... 6 3.4 Test Configuration ................................................................................................................. 6 3.5 Test Procedure ....................................................................................................................... 7 3.6 Test Results ............................................................................................................................ 7 3.7 Measurement Uncertainty ....................................................................................................10 Report no: JSH01*1066-001 Page 4 of 10 FCC ID OUMSMX120 1.Applicant Information Applicant :Suzhou Sanex Electronics Co., Ltd. Xin Su Industrial Zone, Northeast of Ba Ji Bridge, Dong Huan Road, Suzhou, Jiangsu 215001, P.R. China Manufacturer: Suzhou Sanex Electronics Co., Ltd. Xin Su Industrial Zone, Northeast of Ba Ji Bridge, Dong Huan Road, Suzhou, Jiangsu 215001, P.R. China Country of origin: P.R. China Name of contact: Mr. Yingping (first name) Shen (last name) Telephone: 86-512-7248473 Telefax: 86-512-7246087 2.Information of Equipment Under Test (EUT) 2.1 Identification of the EUT Equipment: Compact Fluorescent Lamp Type of EUT:! Production " Pre-product " Pro-type Type/model: SMI-9, SMI-11, SMI-13, SMI-15, SMR-9, SMR-11, SMR-13, SMR-15 Serial number: 01*1066-001, 01*1066-002, 01*1066-003, 01*1066-004 01*1066-005, 01*1066-006, 01*1066-007, 01*1066-008 Date of sample receipt2001-10-9 Date of test2001-10-23 Rating: 120V~, 60Hz 9W for SMI-9, SMR-9, 11W for SMI-11, SMR-11 13W for SMI-13, SMR-13, 15W for SMI-15, SMR-15 2.2 Additional information about the EUT The family of product contains 8 models, which were described above. They are the same in schematic diagram, difference between them are their appearance and rating. Internal clock frequencies or other used frequencies: None The tests have been performed on the EUT provided with the following modification: None 2.3 Peripheral equipment None Report no: JSH01*1066-001 Page 5 of 10 FCC ID OUMSMX120 3. Conducted Powerline Measurement 3.1 Conduction Limit For Consumer Equipment Maximum RF line voltage measured with a 50uH/50 ohm LISN Frequency (MHz) (μV)dB(μV) 0.45 – 2.5125048 2.51 – 3.0300069.5 3.0 – 3025048 RF Line Voltage dB(μV) = 20 lg RF Line Voltage (μV) 3.2 Instruments List The following instruments were used during the measurement of RF voltage conducted back into the power lines. ItemEquipmentManu.TypeSerials no.Last Cal. Cal. Interval 1 EMI Test Receiver Rohde & Schwarz ESCS 30828985/0262001-2-81 Year 2A.M.N. Rohde & Schwarz ESH3-Z5825640/0182001-3-51 Year 3 Shielded Room-- 3m×7…

Text truncated - open the document above for the full version.

Test Report

FCC ID:OUMSMX120 Conducted Powerline Waveform 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMI9_fin QP MES SMI9_pre PK LIM FCC Part18 QP SMI-9 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMI15_fin QP MES SMI15_pre PK LIM FCC Part18 QP SMI-11 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMI13_fin QP MES SMI13_pre PK LIM FCC Part18 QP SMI-13 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMI11_fin QP MES SMI11_pre PK LIM FCC Part18 QP SMI-15 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] xx x x x x x xMES SMR9_fin QP MES SMR9_pre PK LIM FCC Part18 QP SMR-9 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMR11_fin QP MES SMR11_pre PK LIM FCC Part18 QP SMR-11 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMR13_fin QP MES SMR13_pre PK LIM FCC Part18 QP SMR-13 FCC ID:OUMSMX120 0 10 20 30 40 50 60 70 80 Level [dBμV] 450k700k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Frequency [Hz] x x x x x x x xMES SMR15_fin QP MES SMR15_pre PK LIM FCC Part18 QP SMR-15 x All graphs shown above are peak values

Test Setup Photos

FCC ID: OUMSMX120 Photograph of test setup

Contact Information

Applicant

Huaxin Chen(Vice President)
[email protected](86) 512- 724 4897Fax: (86) 512- 724 6087

Technical Contact

Intertek Testing Services ETL SEMKO Shanghai LimitSteve Li
[email protected]86-21-58822300

16th, Floor, Fangdi Mansion, No. 201 Laoshan Road · Shanghai · China

Non-Technical Contact

Intertek Testing Services ETL SEMKO Shanghai LimitSteve Li
[email protected]86-21-58822300

Test Firm

Shanghai Institute of Process Automation Instr.Wang Ying
[email protected]86-2-164847452Fax: 86-2-164847454

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.044 MHz - 0.046 MHz-

Other Applications from Suzhou Sanex Electronics Co. Ltd.

8CC - Part 18 Consumer Device - FCC ID OUMSGF120 - Suzhou Sanex Electronics Co. Ltd.
OUMSGF120

8CC - Part 18 Consumer Device

Jan 17, 2000

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving lamp - FCC ID OUMSDF120 - Suzhou Sanex Electronics Co. Ltd.
OUMSDF120

Energy Saving lamp

Jan 10, 2000

Equipment Class