Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TweezEpil is an electric tweezer especially designed for painless andlong-lasting removal of hair from the root (Picture A).The hair’s root is destroyed by the transmission of radio waves throughthe hair to the root, dissolving it by electrolysis. After about 30 secondsthe hair can be easily removed. The tweezer can remove hairs from allparts of the body. TweezEpil is battery operated, uses four AA alkalinebatteries and does not need any electric outlet. Its strength selectormonitors the intensity of the radio waves. The tweezer’s locking devicerelieves you from keeping the operating button pressed throughout eachhair treatment (Picture B). After 30 seconds a buzzing tone will be heard.A gentle pull will then remove the hair painlessly.Please read the following instructions carefully.Safety Instructions• Use the device only for its intended purpose and in accordance with the user instructions. Any damage caused by disregarding theseinstructions shall be at the user’s sole responsibility. • DO NOT use the tweezer to remove hair from nostrils, ears or eyelashes. • DO NOT use the device in the bath or shower.• Pregnant women, patients after heart transplants or with pacers, and patients under medical supervision should consult their physicianbefore using the device. • If the device becomes damaged, take it to one of the service stations. Do not attempt to repair it yourself. • Prevent children from playing with or handling the tweezer or any of its parts. E NGLISH User Instructions• Remove the battery compartment’s cover, at the bottom of the kit, by pressing the opening button (picture E). • Insert four AA alkaline batteries according to the markings. If you insert the batteries in the wrong position the tweezer will not work. • Switch the device on using the operating switch, which also serves as the tweezer’s strength selector. The tweezer is immediately readyfor use. To remove delicate hairs, switch the selector to low strength.To remove thick hairs, select the high strength. • Stretch the skin and grab one hair with the tweezer (picture B). Pressing the operating switch will lock the tweezer on the hair and activate thetimer. After 30 seconds a buzzing tone will sound. A gentle shake inthe direction of the hair’s growth will remove it easily and painlessly.(pictures C, D) • It is recommended to use the tweezer first on leg or arm hair, where it is easier to operate and see the results of the treatment. Afteracquiring basic experience you can move to more sensitive areas. • For best results the hairs should be 3-5 mm. long.• The skin should be dry, clean and free of make-up or cream. The tweezer ends should be free of hairs and oil. • After treatment, soothe the treated area with a suitable cream.Cleaning and Maintenance• Keep the tweezer ends clean by wiping them with alcohol after every use.• The batteries should be checked regularly to prevent leakage. If you do not plan to use the tweezer for several weeks, remove the batteriesfrom the device. Important• Do not use the device in the bath, shower or any humid place.• Do not remove hair from areas around open wounds, bruises, sunburns or blisters. TweezEpil est une pince Ă Ă©piler Ă©lectrique spĂ©cialement conçue pourune Ă©pilation indolore et durable du poil et de sa racine (A).La racine du poil est dĂ©truite par Ă©lectrolyse, par la transmission d’ondesradio Ă travers le poil vers sa racine. Au bout d’environ 30 secondes, lepoil est aisĂ©ment dĂ©logĂ©. La pince peut ĂŞtre utilisĂ©e sur tout le corps.TweezEpil nĂ©cessite quatre piles alcaline AA, et ne doit donc pas ĂŞtrebranchĂ©e sur le secteur. Son variateur de puissance contrĂ´le l’intensitĂ©des ondes radio. Le système de verrouillage de l’appareil vous dispensed’appuyer sur l’interrupteur durant l’épilation (B). Au bout de 30 secondes,un signal sonore vous avertit qu’il suffit de tirer lĂ©gèrement sur le poilpour l’enlever sans douleur.Veuillez lire attentivement les consignes suivantes. Consignes de sĂ©curité• Utilisez l’appareil conformĂ©ment Ă sa destination et aux consignes d’utilisation. La responsabilitĂ© des dommages dus Ă une utilisationnon conforme aux prĂ©sentes recommandations sera entièrementassumĂ©e par l’utilisateur. • N’UTILISEZ PAS l’appareil pour l’épilation des narines, des oreilles ou des cils. • N’UTILISEZ PAS l’appareil dans le bain ou sous la douche.• Les femmes enceintes, les personnes ayant subi une transplantation cardiaque, possĂ©dant un stimulateur cardiaque ou sous surveillancemĂ©dicale doivent consulter leur mĂ©decin avant d’utiliser l’appareil. • Rapportez l’appareil endommagĂ© au service clientèle le plus proche. Ne tentez pas de le rĂ©parer vous-mĂŞme. • Ne laissez pas des enfants jouer avec l’appareil ou manipuler ses Ă©lĂ©ments. F RANÇAIS TweezEpil consiste en una pinza elĂ©ctrica diseñada especialmente paraextraer el pelo desde su raĂz, en forma duradera y sin dolor (figura A).La raĂz del pelo es destruida debido a la transmisiĂłn de ondas de radio atravĂ©s del pelo hacia la raĂz, disolviĂ©ndola por medio de electrĂłlisis. Alcabo de aproximadamente 30 segundos, el pelo puede ser extraĂdofácilmente. Esta pinza es capaz de extraer pelos de todas partes del cuerpo.TweezEpil funciona con cuatro baterĂas alcalinas AA y no requiere deningĂşn enchufe elĂ©ctrico. Su selector de intensidad monitorea la intensidadde las ondas de radio. El dispositivo de bloqueo de la pinza la liberará demantener el botĂłn de operaciĂłn oprimido durante el tratamiento de cadapelo (figura B). Al cabo de 30 segundos, oirá un zumbido y el pelo seráextraĂdo sin dolor por medio de un suave tirĂłn.Lea las siguientes instrucciones detenidamente.Instrucciones de seguridad• Utilice el aparto sĂłlo para los propĂłsitos destinados y acorde con las instrucciones de usuario. Todo daño causado por omisiĂłn de dichasinstrucciones quedará bajo la responsabilidad exclusiva del usuario. • NUNCA utilice esta pinza para extraer pelos de los orificios de la nariz, las orejas o las pestañas. • NUNCA utilice el aparato en el baño o la du…
Text truncated - open the document above for the full version.
March 2, 2000 FEDERAL COMMUNICATIONS COMMISSION EQUIPMENT APPROVAL SERVICES P.O.B. 358315 Pittsburgh, PA 15251-5315 USA Subject: Application for certification of Electrolysis Tweezers, ME 510-00, FCC ID:OWQTWEEZEPIL Dear Gentlemen, Please find attached our application for certification of Electrolysis Tweezers, ME 510-00, model ME 510-00, FCC ID: OWQTWEEZEPIL, prepared in accordance with FCC Rules, parts 2 and 18. The product testing and this application for certification were performed by Hermon Laboratories, which is listed by FCC. Hermon Labs responsible person is Dr. Edward Usoskin, tel: 01197266288001, fax:01197266288277, e-mail: [email protected] We hope this application satisfies your requirements. Sincerely yours, Moty Lapid General Manager
External view External view open Bottom view Bottom view with label
The identification label (material – polyester) is affixed to the bottom of TweezEpil rear side. The photograph is shown below.
 March 14, 2000 RATING PLATE FOR “Tweez Epil” MODEL No.: ME 510-10 FCC ID: OWQTWEEZEPIL INPUT: 6 VDC ( 4 x 1.5 AA ) This device complies with FOR INDOOR USE ONLY Part 18 of the FCC rules DESIGNED BY EPILADY MADE IN P.R.C.
Internal view PCB component side PCB printed side
Test Report: 88895 Date: January, 2000 Page 1 of 19 HERMON LABORATORIES Electrical Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972-6628-8001 Fax.+972-6628-8277 Email: [email protected] ELECTROMAGNETIC EMISSIONS TEST REPORT ACCORDING TO FCC CFR 47 PART 18 SUBPART C for EPILADY L.L.C. EQUIPMENT UNDER TEST: Electrolysis Tweezers ME 510-00 Test Report: 88895 Date: January, 2000 Page 2 of 19 HERMON LABORATORIES Description of equipment under test Test itemsElectrolysis tweezers ManufacturerEpilady 2000 L.L.C. Types (Models)ME 510-00 Receipt dateDecember 5, 1999 Applicant information Applicant’s responsible personMr. Aharon Nechushtan CompanyEpilady 2000 L.L.C. AddressKibbutz Hagoshrim, D.N. Upper Galilee Postal code12225 CountryIsrael Telephone number+972 6695 6242 Telefax number +972 6695 6222 Test performance Project Number:13814 LocationHermon Laboratories Test startedDecember 5, 1999 Test completedJanuary 3, 2000 Purpose of testApparatus verification in accordance with FCC part 18 requirements Test specification(s)FCC part 18 Test Report: 88895 Date: January, 2000 Page 3 of 19 HERMON LABORATORIES Table of Contents 1SUMMARY AND SIGNATURES ................................................................................................. 4 2GENERAL INFORMATION......................................................................................................... 5 2.1A BBREVI ATIONS AND ACRONYMS .............................................................................................. 5 2.2S PECIFICATION REFERENCES ...................................................................................................... 5 2.3EUT DESCRIPTION ..................................................................................................................... 6 2.4EUT TEST CONFIGURATION ....................................................................................................... 6 3TEST FACILITY DESCRIPTION................................................................................................ 7 3.1G EN ERA L .................................................................................................................................... 7 3.2E QUIPMENT CALIBRATION .......................................................................................................... 7 3.2.1Expanded uncertainty at 95% confidence in Hermon Labs EMC measurements............. 7 3.3S TATEMENT OF QUALIFICATION ................................................................................................. 8 4TEST PROCEDURES AND RESULTS........................................................................................ 9 4.1R ADIATED EM ISSION MEASUREMEN TS ....................................................................................... 9 4.1.1General.............................................................................................................................. 9 4.1.2Test procedure................................................................................................................... 9 APPENDIX A - TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS ........................ 17 APPENDIX B-TEST EQUIPMENT CORRECTION FACTORS ................................................... 18 Test Report: 88895 Date: January, 2000 Page 4 of 19 HERMON LABORATORIES 1 Summary and signatures The EUT, electrolysis tweezers, were found to comply with the limits of FCC part 18. Test performed by: Mrs. Eleonora Pitt, test engineer________________ Test report prepared by: Mr. Alex Lik, certification engineer________________ Test report approved by: Mr. Alex Usoskin, QA manager_______________ The A2LA logo endorsement applies only to the test methods and the standards that are listed in the scope of Hermon Laboratories accreditation by A2LA. Through this report a point is used as the decimal separator, while thousands are counted with a comma. This report is in conformity with EN 45001 and ISO GUIDE 25. The test results relate only to the items tested. This test report must not be reproduced in any form except in full with the approval of Hermon Laboratories Ltd. Test Report: 88895 Date: January, 2000 Page 5 of 19 HERMON LABORATORIES 2 General information 2.1 Abbreviations and acronyms The following abbreviations and acronyms are applicable to this test report: ACalternating current cmcentimeter CEconducted emissions dBdecibel dBmdecibel referred to one milliwatt dB(μV)decibel referred to one microvolt dB(μV/m)decibel referred to one microvolt per meter DCdirect current EMCelectromagnetic compatibility EUTequipment under test GHzgigahertz Hheight Hzhertz kHzkilohertz kVkilovolt Llength LISNline impedance stabilization network mmeter MHzmegahertz NAnot applicable NARTENational Association of Radio and Telecommunications Engineers, Inc. PCpersonal computer QPquasi-peak (detector) REradiated emission RMSroot-mean-square secsecond Vvolt Wwidth 2.2 Specification references CFR 47, part 18, Subpart C: 10/1998 Industrial Scientific and Medical Equipment, Subpart C. ANSI C63.2:06/1996American National Standard for Instrumentation- Electromagnetic Noise and Field Strength, 10 kHz to 40 GHz-Specifications. ANSI C63.4:1992American National Standard for Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. Test Report: 88895 Date: January, 2000 Page 6 of 19 HERMON LABORATORIES 2.3 EUT description The EUT, TweezEpil, model ME 510-00 is electronic tweezers fed with four 1.5 V batteries and designed for painless and long lasting hair removal by means of transmission of radio waves through the hair to the root, dissolving it by electrolysis and hereby destroying the hair’s root. 2.4 EUT test configuration For full test configuration refer to Figure 2.4.1. Figure 2.4.1 EUT test configuration EUT Tweezers tip Test Report: 88895 Date: January, 2000 Page 7 of 19 HERMON LABORATORIES 3 Test facility descriptio…
Text truncated - open the document above for the full version.
HaRakevet Industrial Zone · Binyamina · Israel
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 27.12 MHz - 27.12 MHz | - |