Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 11, 2000
Application Purpose
Original Equipment
Date of Application
Mar 26, 2000
Equipment Note
Home Entertainment Remote Control
Frequency Range
310.00000000 - 310.00000000
Company
Silverlit Toys Manufactory Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—
โ†—

Internal Photos

โ†—

Operational Description

โ†—

Parts List/Tune Up Info

โ†—

Schematics

โ†—

Test Report

โ†—
โ†—
โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Set Up and Operating Instructions for Remote Control Model R550 To setup the remote: Direct Entry method: Press and hold CODE SEARCH until the red lights stays on. Press and release TV, VCR, CBL, AUX, AUX1, AUX2, or AUX3. Enter the three digit code for your TV, VCR, etc., from the code list. Code Search method: Manually turn on the device you want to control (TV, VCR, etc.). Press and hold CODE SEARCH until the red light stays on. Press TV, VCR, CBL, etc. Press the power button repeatedly until the device turns off. This may take up to 300 tries. When the device turns off, press MUTE to complete the setup. If you skip past the code (i. e, press power again after the device turns off) press CHANNEL DOWN to go back. Operation: You do not need to aim the remote at anything. The remote transmits wireless Radio Frequency (RF) commands to the RF to IR converter, Model P550 which converts the command back to Infrared (IR) commands to control your TV, VCR, Cable Box, etc. F.C.C. CAUTION - THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for remote control security devices in accordance with the specifications in Sub-Part B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by unplugging the equipment, try to correct the interference by one or more of the following measures. o Reorient the antenna of the radio/TV experiencing the interference. o Relocate the product with respect to the radio/TV. o Move the product away from the radio/TV. o Plug the product into an outlet on a different electrical circuit from the radio/TV experiencing the interference. If necessary, consult your local dealer for additional suggestions. NOTE: NO CHANGES OR MODIFICATIONS MAY BE MADE TO THE UNITS. ANY CHANGES MADE TO THE UNITS WILL VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT. Zenith Electronics, Huntsville, Alabama 35824 R550-2/8/00

Block Diagram

IR Driver Disable MPU Block Diagram for R550 RF Remote Key Matrix 310MHz Transmitter 310MHz

ID Label/Location Info

7 in 1 RF Universal Remote Use with ZEV215 & ZEN550. Use 2 AAA alkaline batteries. 1. Press and hold CODE SEARCH until red light stays on. 2. Press and release mode button (TV, VCR, CBL, etc. 3. Enter 3 digit code from code list. FCC ID: OXYR550 R550 remote rating label 2: 1 3/23/00 Model R550 Zenith Electronics, Huntsville, Alabama 35824 Made in China

Operational Description

Set Up and Operating Instructions for Remote Control Model R550 To setup the remote: Direct Entry method: Press and hold CODE SEARCH until the red lights stays on. Press and release TV, VCR, CBL, AUX, AUX1, AUX2, or AUX3. Enter the three digit code for your TV, VCR, etc., from the code list. Code Search method: Manually turn on the device you want to control (TV, VCR, etc.). Press and hold CODE SEARCH until the red light stays on. Press TV, VCR, CBL, etc. Press the power button repeatedly until the device turns off. This may take up to 300 tries. When the device turns off, press MUTE to complete the setup. If you skip past the code (i. e, press power again after the device turns off) press CHANNEL DOWN to go back. Operation: You do not need to aim the remote at anything. The remote transmits wireless Radio Frequency (RF) commands to the RF to IR converter, Model P550 which converts the command back to Infrared (IR) commands to control your TV, VCR, Cable Box, etc. F.C.C. CAUTION - THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for remote control security devices in accordance with the specifications in Sub-Part B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by unplugging the equipment, try to correct the interference by one or more of the following measures. o Reorient the antenna of the radio/TV experiencing the interference. o Relocate the product with respect to the radio/TV. o Move the product away from the radio/TV. o Plug the product into an outlet on a different electrical circuit from the radio/TV experiencing the interference. If necessary, consult your local dealer for additional suggestions. NOTE: NO CHANGES OR MODIFICATIONS MAY BE MADE TO THE UNITS. ANY CHANGES MADE TO THE UNITS WILL VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT. Zenith Electronics, Huntsville, Alabama 35824 R550-2/8/00

Parts List/Tune Up Info

R550 RF REMOTE 038010H11093PLAIN WHITE LABELEA1.0000 038010H11501INSTRUCTION LABELEA1.0000 038010H11765MODEL NO LABELEA1.0000 183010H16930BATTERY COVEREA1.0000 185000H16150BOTTOM CABINETEA1.0000 185000H16170TOP CABINETEA1.0000 275000H10560RUBBER KEYPADEA1.0000 403011H10159SPRING CONTACTEA1.0000 851001H11049PCB ASSYEA1.0000 042010H10700-CPCBEA1.0000 055-10400000CAP-C 100N +8-2 25V Y5VEA2.0000 C1,3 057-10100019CAP-E 100U 20% 10VEA1.0000 C2 080001H100504MHZ RESONATOR W/2 CAPEA1.0000 Y1 210010H10010TRS-H9013EA1.0000 Q1 211328H10192IC DIEEA1.0000 U1 240-33906011RES-CF 3R3 +/-5% 1/8WEA1.0000 R3 240-68106011RES-CF 680R +/-5% 1/8WEA1.0000 R4 220-00200350LED 2MM-TOWER REDEA1.0000 LED 220-00200220IR EMITTING LED 5MMEA1.0000 IR1 240-10506011RES-CF 1M +/-5% 1/8WEA1.0000 R1 240-82006022RES-CF 82R +/-5% 1/4WEA1.0000 R4 358-60821001WIRE-JUMPER D=0.6MMEA2.0000 403011H10151SPRING CONTACT (-VE)EA1.0000 403011H10152ASPRING CONTACT (+VE)EA1.0000 851001H10598RS REMOTE, RF 310MHZEA1.0000 042010H10410PCB, RFEA1.0000 076-10000002CAP-MCC 10P 5% NPO 0805EA1.0000 076-10900000CAP-MCC 1P .25P NPO 0805EA2.0000 076-30900000CAP-MCC 3P .25P NPO 0805EA1.0000 076-70900000CAP-MCC 7P .25P NPO 0805EA1.0000 124000H10001RF COIL 31TEA1.0000 162089H10014RF WIRE LOOP ID=6 WD=0.6EA1.0000 209117H10002TRS-NPN MPS H10EA1.0000 212107H10000DIODE-SI 1N4148EA1.0000 240-68206011RES-CF 6K8 +/-5% 1/8WEA1.0000 241-30000000RES-TFC 30R 5% 1/10W 0805EA1.0000 241-68200000RES-TFC 6K8 5% 1/10W 0805EA1.0000 358-60821001WIRE-JUMPER D=0.6MMEA4.0000

Schematics

D C B A 12345678 A B C D 87654321 SHEET No. DATE DATE REVISION DATE FIRST DRAWN FILE DRN APPD. DO NOT SCALE DRAWINGTITLE: REV. C:\R550.SCH 11of C ZEN R550 PRINT DATE 1-Feb-2000 17/9/99 17/9/99 24/1/99 KEY13 CAB 13/3 KEY19 AUX 13/4 KEY20 CODESEARCH 14/4 KEY26 A 14/5 KEY31 AUX3 13/6 KEY32 PREV.CH. 14/6 KEY37 AUX1 13/7 KEY7 VCR 13/2 KEY1 TV 13/1 KEY2 MUTE 14/1 KEY8 VOL.DOWN 14/2 KEY14 VOL.UP 14/3 KEY43 AUX2 13/8 KEY50 UP 14/19 LED1 R2 82R Y1 4MHZ R1 1M IR1 TR1 9013G VSS VSS 2 x AAA BATTERIES BATT1 BATT2 C4 VSS OPTIONAL * NOTES:- 1/ ALL UNSPECIFIED DIODES 1N4148 OR EQUIVALENT. 2/ ALL UNSPECIFIED RESISTORS ARE 0.125W 5%. 3/ ALL UNSPECIFIED CAPACITORS ARE AXIAL MLC TYPE. "*" DENOTES COMPONENT NOT INSTALLED +3V 11-7 26 D-0 11 D-1 12 11-6 25 11-5 24 C-1 35 C-0 34 TSTP_P 32 RSTP_N 29 SXI 31 SXO 30 D-7 18 D-6 17 D-5 16 D-4 15 D-3 14 D-2 13 10-1 2 10-0 1 10-3 4 10-2 3 10-5 6 10-4 5 10-7 8 10-6 7 11-1 20 11-0 19 11-3 22 11-2 21 C-3 37 VDD 33 C-2 36 FXI 28 FXO 27 GND 10 11-4 23 IR-OUT 9 U1 ROO8-USA KEY3 CH.DOWN 15/1 KEY15 RECORD 15/3 KEY16 STOP 16/3 KEY17 PAUSE 17/3 KEY21 1 15/4 KEY22 2 16/4 KEY23 3 17/4 KEY27 4 15/5 KEY28 5 16/5 KEY29 6 17/5 KEY33 B 15/6 KEY35 CC 17/6 KEY39 7 15/7 KEY41 9 17/7 KEY5 CH.UP 17/1 KEY9 REWIND 15/2 KEY10 PLAY 16/2 KEY11 FF 17/2 KEY4 POWER 16/1 KEY45 TV/VCR 15/8 KEY47 ENTER 17/8 KEY34 C 16/6 KEY40 8 16/7 KEY46 0 16/8 KEY51 LEFT 15/19 KEY53 RIGHT 17/19 KEY57 MENU 15/20 KEY59 EXIT/QUIT 17/20 KEY58 DOWN 16/20 D-2D-3D-4D-5D-6 10-0 10-1 10-2 10-3 10-4 10-5 10-6 10-7 11-0 11-1 C3 100NF VSS C2 100UF 6.3V VSS SIGNAL ENABLE OPTIONAL RF DAUGHTER BOARD VSS R11 6K8 C4 10PF C5 1P C6 1P C7 7P C8 2P R12 6K8 TR4 MPSH10 R13 100R D2 L1 6MM L2 31T D=2MM DAUGHTER BOARD R3 3R3 R4 680R D1 * VSS

Test Report

Test Report No. R-8412-1 FCC ID: OXYR550 APPLICANT Chungli Investments (Bermuda) LTD. Cedar House 41 Cedar Avenue Hamilton HM EX Bermuda TEST SPECIFICATION:FCC Rules and Regulations Part 15, Subpart C, Para. 15.231 TEST PROCEDURE:ANSI C63.4:1992 TEST SAMP LE DESCRIP TION BRANDNAME:ZentithMODEL:R550 TYPE:Pulsed RF Transmitter POWER REQUIREMENTS:2 new A AAA @ Batteries FREQUENCY OF OPERATION:310 MHz TESTS P ERFORMED Para. 15.231(a), Radiated Emissions, Fundamental and Harmonics Para. 15.231(c), Occupied Bandwidth Duty Cycle Determination REPORT OF MEASUREMENTS Applicant: Chungli Investments Device:Pulsed RF Transmitter FCC ID: OXYR550 Applicable Rule Section:Part 15, Subpart C, Section 15.231 Test Report No. R-8412-1 FCC ID: OXYR550 REPORT OF MEASUREMENTS (continued) TEST RESULTS 15.231 (a) -The device is used as a transmitter for remote control purposes. 15.231 (a)(1) & -The transmitter is manually operated and ceases transmission within 5 15.231(2)seconds after deactivation. 15.231 (a)(3) -The transmitter does not perform periodic transmissions. 15.231 (a)(4)-Not applicable 15.231 (b) -The fundamental field strength did not exceed 5833 ฮฆ V/M (Average) at a test distance of 3 meters. In addition, the requirements of section 15.35 for averaging pulsed emissions and for limiting peak emissions were met. The field strength of harmonic and spurious emissions did not exceed 583 ฮฆ V/M (AVERAGE). 15.231 (c) -The device operates at 310 MHz. The bandwidth of emissions did not exceed 0.25% of the operating frequency (775 kHz). DETERMINATION OF FIELD STRENGTH LIMITS The field strength limits shown below are found in Section 15.231: FrequencyLimit F1=2603750 =L1 Fo=310Lo F2=47012500 =L2 The formula below was utilized to determine the limits: Limit = L1 + [(Fo-F1)(L2-L1)/(F2-F1)] Solving yields: Fundamental Limit= 5,833 ฮฆ V/M (AVERAGE) @ 3 Meters Harmonic Limit= 583 ฮฆ V/M (AVERAGE) @ 3 Meters Test Report No. R-8412-1 FCC ID: OXYR550 REPORT OF MEASUREMENTS (continued) DETERMINATION OF DUTY CYCLE The unit = s RF output was directly coupled to the input of the spectrum analyzer. The analyzer was set for a frequency span of 0Hz. The sweep time was then adjusted in order to display one full pulse train. The transmitter on time was then summed and compared to the time for one full cycle in order to obtain the duty cycle.( See plots for additional information) Transmitter On Time=25.5 milliseconds (maximum- worst case in 100 ms) Transmitter Cycle Time=> 100 milliseconds Transmitter Duty Cycle=25.5 % CALCULATION: 1 Large Pulse = 8.3 milliseconds 33 x 500 ฮฆ s (small pulse)= 16.5 milliseconds 9 + 33= 25.5 milliseconds Duty Cycle=25.5 % Correction Factor = 20 log (0.5) =-11.9 SPECTRUM ANALYZER DESENSITIZATION CONSIDERATIONS Due to the nature of the emissions being measured, care was taken to ensure that the resolution bandwidth of the spectrum analyzer was adequate to provide accurate measurements. The following formula was utilized: Setting pulse desensitization equal to zero and utilizing the minimum observed pulse width of 500 ฮฆ s yields a minimum required bandwidth of 1333 Hz. FCC specified bandwidths of 100kHz and 1MHz were utilized below and above 1GHz, respectively. Test Report No. R-8412-1 FCC ID: OXYR550 REPORT OF MEASUREMENTS (continued) GENERAL NOTES 1. All readings were taken utilizing a peak detector function at a test distance of 3 meters. 2. The duty cycle was applied to the peak readings in order to determine the average value of the emissions. 3. All measurements were made with 2 new A AAA @ batteries. 4. The frequency range was scanned from 30 MHz to 3.1 GHz. All emissions not reported were more than 20 dB below the specified limit. Test Report No. R-8412-1 FCC ID: OXYR550 EQUIPMENT LIST FCC part 15,subpart C, Radiated Emissions, 30MHz-3.1GHz ENTypeManufacturer Frequency RangeModel No.Cal Date Due Date 067Open Area Test SiteRetlif3 MeterRNY10/15/1997 10/15/2000 128C Double Ridge GuideEaton Corporation1 GHz - 18 GHz9600109/16/1999 09/16/2000 133Broadband Pre-Amplifier Electro-Metrics10 kHz - 1 GHz, 26dB BPA-100006/22/1999 06/22/2000 141Spectrum AnalyzerHewlett Packard100 Hz - 40 GHz8566B09/20/1999 03/20/2000 141A Graphics PlotterHewlett PackardN/A7470A03/05/1999 03/05/2000 141B Quasi-Peak AdaptorHewlett Packard100 Hz - 1 GHz85650A09/20/1999 03/20/2000 206B 6.0 dB AttenuatorTexscan0 - 1.0 GHzFP-50 - 6 dB06/22/1999 06/22/2000 523BiconilogElectro-Mechanics26 - 2000 MHz3142B10/22/1998 04/22/2000 543PreamplifierHewlett Packard1.0 GHz - 26.5 GHz8449B06/16/1999 06/16/2001 Test Report No. R-8412-1 FCC ID: OXYR550 FCC 15.231(b) RADIATED EMISSIONS, FUNDAMENTAL & HARMONIC (Please see separate e-file attachment named FCC RE Fund & Harm.doc) Test Report No. R-8412-1 FCC ID: OXYR550 FCC 15.231(c) OCCUPIED BANDWIDTH (Please see separate e-file attachment named Occbw.pdf) Test Report No. R-8412-1 FCC ID: OXYR550 DUTY CYCLE PLOTS (Please see separate e-file attachment named Dutycycle.pdf)

Test Report

Retlif Testing Laboratories R Data Sheet 1 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions, Fundamental & Harmonic Emissions Customer: Chungli Investments (Bermuda) LTD. Job No. R-8412-1 Test Sample: 310 MHz RF Remote Paragraph: 15.231(b) Model No.: R550 FCC ID: OXYR550 Operating Mode: Continuously Transmitting a 310 MHz Signal Technician: T.S./P.L. Date : February 17, 2000 Note s: Test Distance: 3 Meters Detector: Peak, Unless otherwise specified Test Freq. Antenna Pol./Height EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Li mi t MH z( V/ H) / Me te r sX / Y / ZdBuVdBdBuV/ muV/ muV/ m 310H / 1.0X76.3-4.0 72.34121.0 58330 | H / 1.0Y77.5-4.0 73.54731.5 | | H / 2.5Z72.1-4.0 68.12541.0 | |V / 1.0X74.9-4.0 70.93507.5 | | V / 2.2Y75.5-4.0 71.53758.4 | 310V / 1.8Z74.0-4.0 70.03162.3 58330 620H / 1.0X49.93.2 53.1451.9 5833 |H / 1.0Y52.83.2 56.0631.0 | | H / 1.5Z51.33.2 54.5530.9 | |V / 2.0X50.43.2 53.6478.6 | | V / 2.0Y47.63.2 50.8346.7 | 620 V / 1.0Z49.63.2 52.8436.5 5833 930H / 1.0X30.07.4 37.4*74.1 5833 |H / 1.0Y30.07.4 37.4*74.1 | |H / 1.0Z30.07.4 37.4*74.1 | |V / 1.0X30.07.4 37.4*74.1 | |V / 1.0Y30.07.4 37.4*74.1 | 930V / 1.0Z30.07.4 37.4*74.1 5833 1240H / 3.0X51.3-3.8 47.5237.1 5000 |H / 2.5Y54.2-3.8 50.4331.1 | |H / 2.5Z49.0-3.8 45.2182.0 | |V / 2.5X45.4-3.8 41.6120.2 | |V / 2.1Y48.0-3.8 44.2162.2 | 1240V / 1.0Z30.0-3.8 26.2*20.4 5000 1550H / 1.0X44.8-0.1 44.7171.8 5000 |H / 1.0Y30.0-0.1 29.9*31.3 | |H / 1.0Z51.1-0.1 51.0354.8 | |V / 1.0X30.0-0.1 29.9*31.3 | |V / 2.2Y51.3-0.1 51.2363.1 | 1550V / 1.0Z30.0-0.1 29.9*31.3 5000 The frequency range was scanned from 30 MHz to 3.1 GHz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements (Minimum system sensitivity) Retlif Job Number R-8412 Retlif Testing Laboratories R Data Sheet 2 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions, Fundamental & Harmonic Emissions Customer: Chungli Investments (Bermuda) LTD. Job No. R-8412-1 Test Sample: 310 MHz RF Remote Paragraph: 15.231(b) Model No.: R550 FCC ID: OXYR550 Operating Mode: Continuously Transmitting a 310 MHz Signal Technician: T.S./P.L. Date : February 17, 2000 Note s: Test Distance: 3 Meters Detector: Peak, unless otherwise specified Test Freq. Antenna Pol./Height EUT Orientation Meter Reading Correction Factor Corrected Reading Converted Reading Peak Li mi t MH z( V/ H) - Me te r sX / Y / ZdBuVdBdBuV/ muV/ muV/ m 1860H / 1.0X49.31.6 50.9350.8 5833 |H / 1.0Y40.01.6 41.6*120.2 | |H / 1.0Z45.21.6 46.8218.8 | |V / 1.0X40.01.6 41.6*120.2 | |V / 2.0Y45.51.6 47.1226.5 | 1860V / 1.0Z43.71.6 45.3184.1 5833 2170H / 2.5X50.6-1.3 49.3291.7 5833 |H / 2.8Y49.2-1.3 47.9248.3 | |H / 1.0Z40.0-1.3 38.7*86.1 | |V / 2.0X48.5-1.3 47.2229.1 | |V / 1.0Y50.3-1.3 49.0281.8 | 2170V / 1.0Z43.6-1.3 42.3130.3 5833 2480H /1.0X40.00.1 40.1*101.2 5833 |H / 1.0Y40.00.1 40.1*101.2 | |H / 1.0Z40.00.1 40.1*101.2 | |V / 1.0X40.00.1 40.1*101.2 | |V / 1.0Y40.00.1 40.1*101.2 | 2480V / 1.0Z40.00.1 40.1*101.2 5833 2790H / 1.0X40.01.4 41.4*117.5 5000 |H / 1.0Y40.01.4 41.4*117.5 | |H / 1.0Z40.01.4 41.4*117.5 | |V / 1.0X40.01.4 41.4*117.5 | |V / 1.0Y40.01.4 41.4*117.5 | 2790V / 1.0Z40.01.4 41.4*117.5 5000 3100H / 1.0X40.03.5 43.5*149.6 5833 |H / 1.0Y40.03.5 43.5*149.6 | |H / 1.0Z40.03.5 43.5*149.6 | |V / 1.0X40.03.5 43.5*149.6 | |V / 1.0Y40.03.5 43.5*149.6 | 3100V / 1.0Z40.03.5 43.5*149.6 5833 The frequency range was scanned from 30 MHz to 3.1 GHz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements (Minimum system sensitivity) Retlif Job Number R-8412 Retlif Testing Laboratories R Data Sheet 3 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions, Fundamental & Harmonic Emissions Customer: Chungli Investments (Bermuda) LTD. Job No. 8412-1 Test Sample: 310 MHz RF Remote Paragraph: 15.231(b) Model No.: R550 FCC ID: OXYR550 Operating Mode: Continuously Transmitting a 310 MHz Signal Technician: T.S./P.L. Date : February 17, 2000 Note s: Test Distance: 3 MetersDuty Cycle: 25.5% Detector: Peak, unless otherwise specifiedDuty Cycle Correction: - 11.9 dB Test Freq. Antenna Pol./Height EUT Orientation Peak Reading Correction Factor Corrected Reading Converted Reading Avg. Li mi t MH z( V/ H) - Me te r sX / Y / ZdBuVdBdBuV/ muV/ muV/ m 310H / 1.0X 72.3 -11.9 60.41047.1 5833 | H / 1.0Y 73.5 -11.9 61.61202.3 | | H / 2.5Z 68.1 -11.9 56.2645.7 | |V / 1.0X 70.9 -11.9 59.0891.3 | | V / 2.2Y 71.5 -11.9 59.6955.0 | 310V / 1.8Z 70.0 -11.9 58.1803.5 5833 620|H / 1.0X 53.1 -11.9 41.2114.8 583.3 |H / 1.0Y 56.0 -11.9 44.1160.3 | | H / 1.5Z 54.5 -11.9 42.6134.9 | |V / 2.0X 53.6 -11.9 41.7121.6 | | V / 2.0Y 50.8 -11.9 38.988.1 | 620 V / 1.0Z 52.8 -11.9 40.9110.9 583.3 930H / 1.0X 37.4 -11.9 25.5*18.8 583.3 |H / 1.0Y 37.4 -11.9 25.5*18.8 | |H / 1.0Z 37.4 -11.9 25.5*18.8 | |V / 1.0X 37.4 -11.9 25.5*18.8 | |V / 1.0Y 37.4 -11.9 25.5*18.8 | 930V / 1.0Z 37.4 -11.9 25.5*18.8 583.3 1240H / 3.0X 47.5 -11.9 35.660.3 500.0 |H / 2.5Y 50.4 -11.9 38.584.1 | |H / 2.5Z 45.2 -11.9 33.346.2 | |V / 2.5X 41.6 -11.9 29.730.5 | |V / 2.1Y 44.2 -11.9 32.341.2 | 1240V / 1.0Z 26.2 -11.9 14.3*5.2 500.0 1550H / 1.0X 44.7 -11.9 32.843.7 500.0 |H / 1.0Y 29.9 -11.9 18.0*7.9 | |H / 1.0Z 51.0 -11.9 39.190.2 | |V / 1.0X 29.9 -11.9 18.0*7.9 | |V / 2.2Y 51.2 -11.9 39.392.3 | 1550V / 1.0Z 29.9 -11.9 18.0*7.9 500.0 The frequency range was scanned from 30 MHz to 3.1GHz. All emissions not recorded were more Than 10 dB below the specified limit. Emissions from the EUT do not exceed the specified limits. *=Noise Floor Measurements (Minimum system sensitivity) Retlif Job Number R-8412 Retlif Testing Laboratories R Data Sheet 4 of 4 Test Method: FCC Part 15 Subpart C Radiated Emissions, Fundamental & Harmonic Emissions Customer: Chungli Investments (Bermuda) LTD. Job No. 8412-1 Test Sample: 310 MHz RF Remote Paragraph: 15.2โ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Miss May Choi(Admin. Manager)
[email protected]852-2916-2211Fax: 852-2834-8797

Technical Contact

Retlif Testing LaboratoriesThomas J Schneider
[email protected]631-737-1500

795 Marconi Avenue ยท Ronkonkoma, New York ยท United States

Non-Technical Contact

Retlif Testing LaboratoriesMichelle Tirado
[email protected]631-737-1500

Technical Specifications

#Rule PartsFrequency RangePower Output
115C310 MHz - 310 MHz-