FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ohsung Electronics Co., Ltd./
  3. OZ5URCZR1

OZ5URCZR1Zigbee Router

Ohsung Electronics Co., Ltd.
Zigbee Router - FCC ID OZ5URCZR1 - Ohsung Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 08, 2010
Application Purpose
Original Equipment
Date of Application
Dec 08, 2010
Equipment Note
Zigbee Router
Frequency Range
2405.00000000 - 2480.00000000
Company
Ohsung Electronics Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 1 / 1 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 APPENDIX H : USER’S MANUAL ZR-1 Z Repeater Owners Manual ZR-1 Z Repeater Owners Manual ©2010 Universal Remote Control,Inc. The information in this manual is copyright protected.No part of this manual may be copied or reproduced in any form without prior written consent from Universal Remote Control,Inc. Universal Remote Control,INC.shall not be liable for operational,technical or edito- rial errors/omissions made in this manual. The information in this manual may be subject to change without priornotice. Complete Control is a registered trademark of Universal Remote Control,Inc. All other brand or product names are trademarks or registered trademarks of their respective companies or organizations. 500 Mamaroneck Avenue, Harrison, NY 10528 Phone: (914) 835-4484 Fax: (914) 835-4532 TABLEOFCONTENTS Introduction1 Features and Benefits1 Parts Guide1 ZR-1 Front and Side Panel Descriptions2 Specifications2 USA Limited Warranty Statement3 Federal Communication Commission Interference Statement4 Regulatory Information to the user5 Declaration of Conformity6 Page 1 ZR-1 Z REPEATER Introduction Congratulations on your purchase of the ZR-1 Z Repeater! The ZR-1 is used to extend the operational range between Total Control proucts such as the TRC-780 and the MRX-10. Once joined to the MRX-10 it will wirelessly relay communication between an TRC-780 and multi- ple ZR-1 repeaters. Features and Benefits Wirelessly extends the range between Total Control products zExtend the operational range between a MS-780 remote and a MRX-10 Advanced Network System Controller. Control lighting, music and more from throughout the home. Additional ZR-1 Repeaters can be joined to create a wireless mesh network throughout the home. Parts Guide The ZR-1 Z Repeater includes: 1 - ZR-1 Z Repeater1 - AC Power Adapter 1 - Wall Mount and 4 Screws1 - Owner’s Manual Page 2 ZR-1 Z REPEATER ZR-1 Front and Side Panel Descriptions Front and Side Panel The front panel consists of 2 indicator lights which will illuminate when in u Power LED: Indicates that the ZR-1 is powered on whenilluminated. Link LED: Indicates the status of the Z communication connectionto the MRX-10. Off = not connected, Blinking = attempting to con- nect, On Steady = connected. Antenna: Omnidirectional antenna. Adjust the antenna for best per- formance. Usually vertical positioning works well. DC9V Power: Attach the included 9V DC power supply here. Mounting Plate: May be attached to a wall or other surface with the included screws for easy slide on/off mounting. Specifications RF Frequency: 2.45GHz (ZigBee-Pro) Effective Range: Typically 50-75 ft, depending on environment Size: L x D x H = 3.625" x 1.125" x 6.625" (with antenna vertical) Weight: 3 oz. Power Supply: 9V DC .300mA Power LED Link LED DC9V Power Mounting Plate Antenna Page 3 USA Limited Warranty Statement Your Universal Remote Control, when delivered to you in new con- dition, is warranted against defects in materials or workmanship as follows: UNIVERSAL REMOTE CONTROL, INC. warrants this prod- uct against defects in material or workmanship for s period of one (1) year and as set forth below. Universal Remote Control will, at its sole option, repair the product using new or comparable rebuilt parts, or exchange the product for a comparable new or rebuilt product. In the event of a defect, these are your exclusive reme- dies. This Limited Warranty covers only the hardware components pack- aged with the Product. It does not cover technical assistance for hardware or software usage and it does not cover any software products whether or not contained in the Product; any such soft- ware is provided “AS IS” unless expressly provided for in any enclosed software Limited Warranty. To obtain warranty service, you must deliver the product, freight prepaid, in its original packaging or packaging affording adequate protection to Universal Remote Control at the address provided in the Owner’s Manual. It is your responsibility to backup any macro programming, artwork, software or other materials that may have been programmed into your unit. It is likely that such data, soft- ware, or other materials will be lost during service and Universal Remote Control will not be responsible for any such damage or loss.A dated purchase receipt, Bill of Sale, Installation Contract or other verifiable Proof of Purchase is required. For product support and other important information visit Universal Remote Control’s website: http://www .UniversalRemote.comor call the Customer Service Center (914) 835-4484. This Limited Warranty only covers product issues caused by defects in material or workmanship during ordinary consumer use. It does not cover product issues caused by any other reason, including but not limited to product issues due to commercial use, acts of God, third-party installation, misuse, limitations of technology, or modifi -cation of or to any part of the Universal Remote Control product. This Limited Warranty does not cover Universal Remote Control products sold as USED, AS IS, REFURBISHED, so-called “B STOCK” or consumables (such as batteries). This Limited Warranty is invalid if the factory-applied serial number has been altered or removed from the product. This Limited Warranty is valid only in the United States of America. This Limited Warranty specifically excludes prod- ucts sold by unauthorized resellers. ZR-1 Z REPEATER Page 4 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc- tions…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 OHSUNG ELECTRONICS CO., LTD #181 Gongdan-Dong, Gumi-Si,Gyeongsangbuk-Do, Korea Tel: +82-54-468-7282, Fax: +82-54-461-8368 December 08, 2010 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, OHSUNG ELECTRONICS CO., LTD, hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: Zigbee Router FCC ID: OZ5URCZR1 We affirm that between SIEMIC and OHSUNG ELECTRONICS CO., LTD, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, --------------------------------------------- Kwang-Jae Ok, Q.C Manager OHSUNG ELECTRONICS CO.,LTD

Cover Letter(s)

Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (current) 1.0 1.0 Nov-14-2006 OHSUNG ELECTRONICS CO., LTD #181 Gongdan-Dong, Gumi-Si,Gyeongsangbuk-Do, Korea Tel: +82-54-468-7282, Fax: +82-54-461-8368 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 Federal Communications Commission Authorization and Evaluation Division December 08, 2010 Confidentiality Request regarding application for certification of FCC ID: OZ5URCZR1 We hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name BLOCK DIAGRAM URCZR1_BlkDia.pdf SCHEMETIC DIAGRAM URCZR1_SchDia.pdf OPERATIONAL DESCRIPTION URCZR1_OpeDes.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. In addition to above mentioned documents, pursuant to Public DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR 2.803 and the importation rules in 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following Exhibit Type File Name TEST SET UP PHOTOS URCZR1_Tsup.pdf EXTERNAL PHOTOGRAPHS URCZR1_ExtPho.pdf INTERNAL PHOTOGRAPHS URCZR1_IntPho.pdf USER’S MANUAL URCZR1_UseMan.pdf The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, --------------------------------------------- Kwang-Jae Ok, Q.C Manager OHSUNG ELECTRONICS CO.,LTD

External Photos

Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 1 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 APPENDIX F : EXTERNAL PHOTOGRAPHS Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 2 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 3 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 4 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1

ID Label/Location Info

Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 1 / 2 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 APPENDIX B : ID SAMPLE LABEL & LOCATION Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 2 / 2 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 LABELLING REQUIREMENTS The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. ID Label  ID Label Location of EUT ID Label

Internal Photos

Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 1 / 6 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 APPENDIX G : INTERNAL PHOTOGRAPHS Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 2 / 6 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 3 / 6 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 4 / 6 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 5 / 6 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 6 / 6 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1

RF Exposure Info

Order Number : GETEC-C1-10-220 FCC Certification Test Report Number : GETEC-E3-10-149 Page 1 / 3 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 APPENDIX L : MAXIMUM PERMISSIBLE EXPOSURE Order Number : GETEC-C1-10-220 FCC Certification Test Report Number : GETEC-E3-10-149 Page 2 / 3 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 Maximum Permissible Exposure 1.1 Applicable Standard Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device (A) Limits for Occupational / Controlled Exposure Frequency range(MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density(S) (mW/cm2) Av er ag ing Time |E|2, |H|2 or S (minutes) 0.3 ~ 3.0 614 1.63 (100)* 6 3.0~30 1842/f 4.89/f (900/f)* 6 30~300 61.4 0.163 1.0 6 300 ~ 1,500 f/300 6 1,500 ~ 100,000 5.0 6 (B) Limits for General Population / Uncontrolled Exposure Frequency range(MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density(S) (mW/cm2) Av er ag ing Time |E|2, |H|2 or S (minutes) 0.3 ~ 1.34 614 1.63 (100)* 30 1.34 ~ 30 824/f 2.19/f (180/f)* 30 30~ 300 27.5 0.073 0.2 30 300 ~ 1,500 f/1500 30 1,500 ~ 100,000 1.0 30 Note: f=frequency in MHz; *Plane-wave equivalent power density 1.2 MPE Calculation Method d GP mVE ×× = 30 )/( Power Density: 377 )/( 2 2 E mWPd= E = Electric field (V/m) P = Peak RF output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to 2 377 30 d GP Pd × ×× = From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained. Order Number : GETEC-C1-10-220 FCC Certification Test Report Number : GETEC-E3-10-149 Page 3 / 3 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 1.3 Calculated Result and Limit Antenna type: dipole antenna Channel Antenna gain (dBi) Antenna gain (numeric) Peak output power (dBm) Peak output power (mW) Power Density (s) (mW/cm 2 ) Limit of Power density (S) (mW/cm 2 ) 11 2.0 1.58 19.32 85.4 0.027 1 20 2.0 1.58 19.36 86.4 0.027 1 26 2.0 1.58 19.25 83.6 0.026 1

Test Report

Order Number : GETEC-C1-10-220 FCC Class B Certification Test Report Number: GETEC-E3-10-149 Page2 / 29 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 CONTENTS 1. GENERAL INFORMATION ...................................................................................................................................... 4 2. INTRODUCTION ........................................................................................................................................................ 5 3. PRODUCT INFORMATION ...................................................................................................................................... 6 3.1 DESCRIPTION OF EUT .............................................................................................................................................. 6 3.2 SUPPORT EQUIPMENT / CABLES USED ..................................................................................................................... 7 3.3 MODIFICATION ITEM(S) ........................................................................................................................................... 7 4. DESCRIPTION OF TESTS ......................................................................................................................................... 8 4.1 TEST CONDITION ...................................................................................................................................................... 8 5. ANTENNA REQUIREMENT - §15.203 ..................................................................................................................... 8 5.1 DESCRIPTION OF ANTENNA ...................................................................................................................................... 8 5.2 CONDUCTED EMISSION ............................................................................................................................................ 9 5.3 RADIATED EMISSION .............................................................................................................................................. 10 6. CONDUCTED EMISSION ........................................................................................................................................ 11 6.1 OPERATING ENVIRONMENT ................................................................................................................................... 11 6.2 TEST SET-UP ........................................................................................................................................................... 11 6.3 MEASUREMENT UNCERTAINTY.............................................................................................................................. 11 6.4 LIMIT ...................................................................................................................................................................... 12 6.5 TEST EQUIPMENT USED .......................................................................................................................................... 12 6.6 TEST DATA FOR CONDUCTED EMISSION ................................................................................................................ 12 7. MAXIMUM PEAK OUTPUT POWER MEASUREMENT .................................................................................. 15 7.1 OPERATING ENVIRONMENT ................................................................................................................................... 15 7.2 TEST SET-UP (LAY O U T) .......................................................................................................................................... 15 7.3 LIMIT ...................................................................................................................................................................... 15 7.4 TEST EQUIPMENT USED .......................................................................................................................................... 15 7.5 TEST RESULT .......................................................................................................................................................... 15 8. POWER SPECTRAL DENSITY MEASUREMENT .............................................................................................. 16 8.1 OPERATING ENVIRONMENT ................................................................................................................................... 16 8.2 TEST SET-UP (LAY O U T) .......................................................................................................................................... 16 8.3 LIMIT ...................................................................................................................................................................... 16 8.4 TEST EQUIPMENT USED .......................................................................................................................................... 16 8.5 TEST RESULT .......................................................................................................................................................... 16 9. 6 DB SPECTRUM BANDWIDTH MEASUREMENT ........................................................................................... 19 9.1 OPERATING ENVIRONMENT ................................................................................................................................... 19 9.2 TEST SET-UP (LAY O U T) .......................................................................................................................................... 19 9.3 LIMIT ...................................................................................................................................................................... 19 9.4 TEST EQUIPMENT USED .......................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 1 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1 APPENDIX E : TEST SET UP PHOTOGRAPHS Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 2 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1  Conducted Test Picture (Front)  Conducted Test Picture (Rear) Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 3 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1  Radiated Test Picture (X axis)  Radiated Test Picture (Y axis) Order Number : GETEC-C1-10-220 FCC Part 15 subpart C Test Report Number : GETEC-E3-10-149 Page 4 / 4 EUT Type: Zigbee Router FCC ID.: OZ5URCZR1  Radiated Test Picture (Z axis)

Contact Information

Applicant

Hak-Ki Kim(General Manager)
[email protected]82-54-468-7281Fax: 82-54-461-8368

Test Firm

Gumi University EMC CenterTae-Sig Park
[email protected]82544401195Fax: 82544401199

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz86.40 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum conducted RF output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Ohsung Electronics Co., Ltd.

OZ5PSRMT

RF4CE RCU

Jan 13, 2026

Equipment Class

DTS - Digital Transmission System
OZ5G32

Remote Controller

Dec 29, 2025

Equipment Class

DTS - Digital Transmission System
OZ5PSEMR

RF Module

Dec 19, 2025

Equipment Class

DTS - Digital Transmission System
OZ5G22

Remote Controller

Dec 16, 2025

Equipment Class

DTS - Digital Transmission System
OZ5G12

Remote Controller

Dec 16, 2025

Equipment Class

DTS - Digital Transmission System