FCC ID: P24RTH-0629 Operation Description: There are a on/off switch and two control sticks on the EUT. Turn on the switch, press the left control sticks to control the forward movement, press the right control stick to control the backward and rotation movement. Circuit Description: The brief circuit description is listed as follows: - C*, R9, Q3 and associated circuit act as Local Oscillator. - Q4 and associated circuit act as RF Amplifier. - Q1, Q2 and associated circuit act as modulation signal generator. Antenna Used: A permanent wire antenna has been used.
β’ The test results reported in this report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. β’ This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited FCC ID : P24RTH-0629 Realtoy International Limited Application For Certification (FCC ID: P24RTH-0629) Transmitter, Model : 82002, 82003 We hereby certify that the sample of the above item is considered to comply with the requirements of FCC Part 15, Subpart C for Intentional Radiator, mention 47 CFR [24-5-2001 edition] WO# 0106398 WN/at November 22, 2001 INTERTEK TESTING SERVICES FCC ID: P24RTH-0629 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: P24RTH-0629 ii MEASUREMENT/TECHNICAL REPORT Realtoy International Limited - MODEL: 82002, 82003 FCC ID: P24RTH-0629 November 22, 2001 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [24-5-2001 Edition] provision Report prepared by:Wilbur Ng Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone:852-2173-8502 Fax:852-2742-9149 INTERTEK TESTING SERVICES FCC ID: P24RTH-0629 iii Table of Contents 1.0 General Description.......................................................................................................................2 1.1 Product Description...................................................................................................................2 1.2 Related Submittal(s) Grants.....................................................................................................2 1.3 Test Methodology......................................................................................................................3 1.4 Test Facility...............................................................................................................................3 2.0 System Test Configuration............................................................................................................5 2.1 Justification...............................................................................................................................5 2.2 EUT Exercising Software..........................................................................................................5 2.3 Special Accessories....................................................................................................................5 2.4 Equipment Modification...........................................................................................................6 2.5 Support Equipment List and Description.................................................................................6 3.0 Emission Results............................................................................................................................8 3.1 Field Strength Calculation........................................................................................................9 3.1 Field Strength Calculation (contβd).........................................................................................10 3.2 Radiated Emission Configuration Photograph......................................................................11 3.3 Radiated Emission Data.........................................................................................................12 4.0 Equipment Photographs.............................................................................................................15 5.0 Product Labelling.........................................................................................................................17 6.0 Technical Specifications..............................................................................................................19 7.0 Instruction Manual......................................................................................................................21 8.0 Miscellaneous Information.........................................................................................................23 8.1 Measured Bandwidth..............................................................................................................24 8.2 Emissions Test Procedures.....................................................................................................25 8.2 Emissions Test Procedures (cont'd)........................................................................................26 INTERTEK TESTING SERVICES FCC ID: P24RTH-0629 iv List of attached file Exhibit typeFile Descriptionfilename Test ReportTest Reportreport.pdf Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated1.jpg to radiated2.jpg Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoophoto1.jpg to ophoto2.jpg Internal PhotoInternal Photoiphoto1.jpg to iphoto2.jpg Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf INTERTEK TESTING SERVICES FCC ID: P24RTH-0629 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: P24RTH-0629 2 1.0General Description 1.1Product Description The equipment under test (EUT) is a tranβ¦
Text truncated - open the document above for the full version.
RADIATED EMISSIONS TEST SETUP PHOTOS
2/F., Garment Centre Β· Kowloon Β· Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 27.145 MHz - 27.145 MHz | - |

RC Car
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RC Car
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RC Car
Equipment Class
CRR - Superregenerative Receiver
Remote Control Toy
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote Controlled Toy Jet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter