User Guide TMO-G4SE 5 G Gateway Release 1.0.0 Manufacturer Sercomm Corporation 8F, 3-1 YuanQu St., Nankang Taipei 115, Taiwan Import fromSercomm Corporation DistributorT-Mobile, Inc. ©T-Mobile USA, Inc. All rights reserved. T-Mobile, the T logo, Magenta, the magenta color and the T-Mobile Internet logo are registered trademarks of Deutsche Telekom AG. Page 3 Need help? Visit https://www.t-mobile.com/internethelp or call T-Mobile customer service at 1-844-275-9310 Metro support service at 1-888-8Metro8 T-Mobile 5G Gateway User Guide Contents Safety Guidelines ..............................................................................................................................5 Potential Equipment Damage ...................................................................................................5 Risk of Electric Shock or Fire .....................................................................................................5 Introduction .......................................................................................................................................6 Getting to Know Your T-Mobile 5G Gateway ...............................................................................6 Physical Interfaces.......................................................................................................................7 Setting up the T-Mobile 5G Gateway ............................................................................................7 Recommended Setup: Use the Mobile App.............................................................................7 Manual Setup: Identify An Ideal Location ...............................................................................8 Connecting Power to the T-Mobile 5G Gateway ...............................................................8 Starting the T-Mobile 5G Gateway .......................................................................................9 Connecting Devices .........................................................................................................................9 Connecting Wi-Fi Devices ..........................................................................................................9 Connecting Ethernet Devices ....................................................................................................9 Viewing Connected Devices ....................................................................................................10 Accessing Your Web GUI (Graphical User Interface) ................................................................10 Home Screen ..............................................................................................................................11 Language Selection ..............................................................................................................12 Wi-Fi Networks Screen .........................................................................................................12 Replacing the SIM Card .................................................................................................................17 Resetting the T-Mobile 5G Gateway ..................................................................................18 Page 4 Need help? Visit https://www.t-mobile.com/internethelp or call T-Mobile customer service at 1-844-275-9310 Metro support service at 1-888-8Metro8 T-Mobile 5G Gateway User Guide Troubleshooting ..............................................................................................................................19 No Signal ......................................................................................................................................19 Prevent Overheating ..................................................................................................................19 T-Mobile 5G Gateway Does Not Start ....................................................................................19 Poor Internet Experience ..........................................................................................................19 Forget Your Admin Password? .................................................................................................19 Understanding the LCD .................................................................................................................19 Connection .................................................................................................................................20 Devices........................................................................................................................................20 Messages .....................................................................................................................................21 Language Settings ....................................................................................................................23 Technical Specifications ...............................................................................................................24 Terms and Conditions ...................................................................................................................25 Privacy Policy .................................................................................................................................25 Customer Support .........................................................................................................................25 Page 5 Need help? Visit https://www.t-mobile.com/internethelp or call T-Mobile customer service at 1-844-275-9310 Metro support service at 1-888-8Metro8 T-Mobile 5G Gateway User Guide Safety Guidelines Potential Equipment Damage Follow these recommendations to protect yourself and the Product from harm: żUse the Product only in upright position as shown in the Quick Start Guide żDo not insert any sharp object into the openings of the Product żDo n…
Text truncated - open the document above for the full version.
Date:March13,2023 We,SercommCorporationdeclarethatthedevicedoesnotsupportchannel12~13 in2.4GHzbandandanynon-USchannelsinalltheoperationalmode(s)forthe followingproduct. FCCID:P27-TMOG4SE Ifyoushouldhaveanyquestion(s)regardingthisdeclaration,pleasedon’thesitateto contactus.Thankyou! ----------------------------------- NickWu/Engineer SercommCorporation Tel:886-2-2655-3988 Fax:886-2-2655-3965 E-mail:[email protected]
Date:2023-03-28 FCCID:P27-TMOG4SE Totheattentionof FederalCommunicationsCommission AuthorizationandEvaluationDivision AttestationStatements AttestationStatementsPart2.911(d)(5)(i)Filing SercommCorporationcertifiesthattheequipmentforwhichauthorizationissoughtis not“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuant tosection2.903oftheFCCrules. AttestationStatementsPart2.911(d)(5)(ii)Filing SercommCorporationcertifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredListasanentityproducing“covered” equipment. Sincerelyyours, -------------------------------------- NickWu/Engineer SercommCorporation Tel:886-2-2655-3988 Fax:886-2-2655-3965 E-mail:[email protected]
Date:2023-03-13 FCCID:P27-TMOG4SE Totheattentionof FederalCommunicationsCommission AuthorizationandEvaluationDivision PermanentConfidentialityRequest PursuanttoSections0.457and0.459oftheCommission’sRules,theApplicanthereby requestsconfidentialtreatmentofinformationaccompanyingthisApplicationasoutlined below: Schematics BlockDiagram OperationalDescription SoftwareOperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesemattersmightbeharmfultothe Applicantandprovideunjustifiedbenefitstoitscompetitors. TheApplicantunderstandsthatpursuanttoRule0.457,disclosureofthisApplicationand allaccompanyingdocumentationwillnotbemadebeforethedateoftheGrantforthis application. Sincerelyyours, ----------------------------------- NickWu/Engineer SercommCorporation Tel:886-2-2655-3988 Fax:886-2-2655-3965 E-mail:[email protected]
Date:2023-03-13 FCCID:P27-TMOG4SE Totheattentionof FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequest PursuanttoSections0.457and0.459ofthecommission’srules,werequestshort-term confidentialtreatmentforthefollowinginformationuntil180daysaftertheGrantDateof EquipmentAuthorizationinordertoensuresensitivebusinessinformationremains confidentialuntiltheactualmarketingofthedevice: Externalphotos TestSetupphotos User’smanual InternalPhotos Sincerelyyours, ----------------------------------- NickWu/Engineer SercommCorporation Tel:886-2-2655-3988 Fax:886-2-2655-3965 E-mail:[email protected]
Date:2023-03-28 FCCID:P27-TMOG4SE AUTHORIZATIONLETTER ToWhomItMayConcern: SercommCorporationherebyauthorizesAndreaHsia/SupervisorofBureauVeritas ConsumerProductsServices(H.K.)Ltd.,TaoyuanBranch(“BVCPSTaoyuan”),toacton itsbehalfinallmattersrelatingtotheFederalCommunicationCommission(“FCC”) applicationforequipmentauthorizationinconnectionwiththeFCCIDlistedabove, includingsigningofalldocumentsrelatingtothesematters.Anyandallactscarriedout byAndreaHsia/SupervisorofBVCPSTaoyuanonSercommCorporation’sbehalf,within thescopeofthepowersgrantedherein,shallhavethesameeffectasactsofitsown. Ifyouhaveanyquestionsregardingtheauthorization,pleasedon’thesitatetocontactus. Sincerelyyours, ----------------------------------------------- NickWu/Engineer SercommCorporation Tel:886-2-2655-3988 Fax:886-2-2655-3965 E-mail:[email protected]
Sercomm Corporation中磊電子股份有限公司 Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Date: 2023-05-08 Re: Supersede request for FCC ID: P27-TMOG4SE; Granted on 04/15/2023 To Whom It May Concern: We regret to inform you that a correction to the certified module's WWAN external antenna gain is needed; this is an update to the antenna gain specified in filing only, no hardware changes were made. To prevent misunderstanding to the public, we would like to request the FCC to supersede the original incorrect Test Report (Co-located)_rev and RF Exposure Info (MPE)_rev2 exhibits with Test Report (Co-located)_rev 2 and RF Exposure Info (MPE)_rev3 respectively. ----------------------------------------------------- Sercomm Corporation Nick Wu/ Engineer TEL: 886-2-2655-3988*2556 FAX: 886-2-2655-3965 E-mail: [email protected]
Reference No.: BEIH-WTW-P22120620-ExtPho Page 1 / 10 CONSTRUCTION PHOTOS OF EUT Reference No.: BEIH-WTW-P22120620-ExtPho Page 2 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 3 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 4 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 5 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 6 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 7 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 8 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 9 / 10 Reference No.: BEIH-WTW-P22120620-ExtPho Page 10 / 10
Reference No.: BEIH-WTW-P22120620-IntPho Page 1 / 15 CONSTRUCTION PHOTOS OF EUT GPS Ant DA 2 DA 4 WiFi Ant 1 WiFi Ant 2 Reference No.: BEIH-WTW-P22120620-IntPho Page 2 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 3 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 4 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 5 / 15 WiFi Ant 0 Ant 6 Reference No.: BEIH-WTW-P22120620-IntPho Page 6 / 15 Ant 5 WiFi Ant 3 Reference No.: BEIH-WTW-P22120620-IntPho Page 7 / 15 BT Reference No.: BEIH-WTW-P22120620-IntPho Page 8 / 15 Ant 2 Ant 4 Ant 3 Ant 1 Reference No.: BEIH-WTW-P22120620-IntPho Page 9 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 10 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 11 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 12 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 13 / 15 Ant 0 Reference No.: BEIH-WTW-P22120620-IntPho Page 14 / 15 Reference No.: BEIH-WTW-P22120620-IntPho Page 15 / 15
Report No.: MFBEIH-WTW-P22120620 R1 Page No. 1 / 13 Report Format Version: 7.1.0 Cancels and replaces the report no. : MFBEIH-WTW-P22120620 dated on Mar. 31, 2023 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1091) Report No.: MFBEIH-WTW-P22120620 R1 FCC ID: P27-TMOG4SE Product: T-Mobile 5G Gateway Brand: T-Mobile Model No.: TMO-G4SE Received Date: 2022/12/19 Test Date: 2023/2/15 Issued Date: 2023/5/5 Applicant: Sercomm Corp. Address: 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kewi Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Designation Number: 788550 / TW0003 Approved by: , Date: 2023/5/5 Jeremy Lin / Project Engineer This test report consists of 13 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Lena Wang / Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBEIH-WTW-P22120620 R1 Page No. 2 / 13 Report Format Version: 7.1.0 Cancels and replaces the report no. : MFBEIH-WTW-P22120620 dated on Mar. 31, 2023 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Applicable RF Exposure Limit .................................................................................................................................. 5 2.1 RF Exposure ............................................................................................................................................................. 7 3 Test Results ................................................................................................................................................................ 9 3.1 RF Exposure ............................................................................................................................................................. 9 4 Conclusion ................................................................................................................................................................ 12 5 Information of the Testing Laboratories ................................................................................................................ 13 Report No.: MFBEIH-WTW-P22120620 R1 Page No. 3 / 13 Report Format Version: 7.1.0 Cancels and replaces the report no. : MFBEIH-WTW-P22120620 dated on Mar. 31, 2023 Release Control Record Issue No. Description Date Issued MFBEIH-WTW-P22120620 Original Release 2023/3/31 MFBEIH-WTW-P22120620 R1 Revise P10~11 External Antenna gain and data 2023/5/5 Report No.: MFBEIH-WTW-P22120620 R1 Page No. 4 / 13 Report Format Version: 7.1.0 Cancels and replaces the report no. : MFBEIH-WTW-P22120620 dated on Mar. 31, 2023 1 Certificate Product: T-Mobile 5G Gateway Brand: T-Mobile Test Model: TMO-G4SE Sample Status: Engineering Sample Applicant: Sercomm Corp. Test Date: 2023/2/15 FCC Rule Part: FCC Part 2 (Section 2.1091) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBEIH-WTW-P22120620 R1 Page No. 5 / 13 Report Format Version: 7.1.0 Cancels and replaces the report no. : MFBEIH-WTW-P22120620 dated on Mar. 31, 2023 2 Applicable RF Exposure Limit § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be us…
Text truncated - open the document above for the full version.
TMO Rainier Antenna Test Report Jan. 18, 2023 Prepared by AK Chen / Shian Chuang Confidential & Proprietary 2 Test Infomation IteamDescription Brand NameT-Mobile EquipmentT-Mobile 5G Gateway, TMO-G4SE Test Location8F, No. 3-1, YuanQu St. Taipei, Taiwan 115 R.O.C. Test ConditionRadiation Test EngineerAK Chen, Sercomm Test EnvironmentETS-Lindgren AMS-8500 Antenna Measurement Chamber Te s t D a t e May. 03, 2022 ~ Dec. 30, 2022 Confidential & Proprietary 3 ETS-Lindgren AMS-8500 antenna measurement system with a size of 7.32(L) ×3.66(W) ×3.66(H) m 3 is used for antenna performance test, which is based on the great-circle test method defined by CTIA. The multi- axis positioning system (MAPS) rotates the DUT around two orthogonal axes for full spherical coverage. Test Configuration Confidential & Proprietary 4 Test Setup & Procedure 1.Fixthe DUT on the dielectric support structure and connect the feeding cable to the antenna used for test 2.Set measurement parameters such as frequency range and sampling angle 3.Perform test and then get far-f ield data (radiation pattern, gain, efficiency) 4.Repeat test procedure for other antennas Confidential & Proprietary 5 Network analyzer and reference antennas are used for calibration. Path loss and cable loss for different frequency bands can be checked and calculated. Test Equipment & Calibration Confidential & Proprietary 6 InstrumentBrandCharacteristicsModel No.Serial No. Calibration Due Date Precision Sleeve Dipole ETS-Lindgren600 MHz ~ 800 MHz3126-70000169715May 21, 2024 Precision Sleeve Dipole ETS-Lindgren800 MHz ~1000 MHz3126-90000169592May 21, 2024 Precision Sleeve Dipole ETS-Lindgren1400 MHz ~1700 MHz3126-155000164599May 21, 2024 Precision Sleeve Dipole ETS-Lindgren1700 MHz ~2000 MHz3126-185000169588May 21, 2024 Precision Sleeve Dipole ETS-Lindgren2000 MHz ~2300 MHz3126-215000169593May 21, 2024 Precision Sleeve Dipole ETS-Lindgren2300 MHz ~2700 MHz3126-250000169597May 21, 2024 Precision Sleeve Dipole ETS-Lindgren5000 MHz ~6000 MHz3126-550000169728May 21, 2024 Horn AntennaSCHWARZBECK1 GHz ~ 18 GHzBBHA 9120DBBHA 9120D-1294Apr. 07, 2024 EMQuest Antenna Measurement Software ETS-LindgrenControl chamber systemEMQ-1001437Non-Calibration Required Test Equipment & Calibration Confidential & Proprietary 7 Outline •Antenna Structure & Placement •Return Loss & Isolation •Radiation Pattern •Peak Gain & Efficiency Confidential & Proprietary 8 Antenna Structure & Placement Ant No.Operating BandTypeMaterial FeedingConn.Dimension Ant 0 LB Tx/Rx PIFAPCBCable I- pex (同等級) 85 x 11.2 x 0.4 mm 3 Ant 1 LB Rx MHB Rx PIFAFPCBSpringNA60.52 x 17.7 x 13.56 mm 3 Ant 2 MHB Tx/Rx UHB Tx/Rx PIFAFPCBSpringNA60.52 x 17.7 x 13.56 mm 3 Ant 3 LB Rx MHB Rx PIFAFPCBSpringNA60.52 x 17.7 x 13.56 mm 3 Ant 4 LB Rx MHB Tx/Rx UHB Tx/Rx PIFAFPCBSpringNA60.52 x 17.7 x 13.56 mm 3 Confidential & Proprietary 9 Antenna Structure & Placement Ant No.Operating BandTypeMaterial FeedingConn.Dimension Ant 5 & Ant 6 UHB Tx/Rx DipolePCBCable I- pex (同等級) 33.5 x 9.25 x 0.4 mm 3 DA2 MHB Tx/Rx UHB Tx/Rx DipolePCBCable I- pex (同等級) 105 x 22 x 0.4 mm 3 DA4 LB Rx MHB Tx/Rx UHB Tx/Rx DipolePCBCable I- pex (同等級) 140 x 22 x 0.4 mm 3 WF0 & WF3 WiFi 2.4G/5G DipolePCBCable I- pex (同等級) 35 x 10 x 0.4 mm 3 WF1 & WF2 WiFi 2.4G/5G PIFAFPCBCable I- pex (同等級) 23.35 x 10.35 x 10.79 mm 3 GPS L1 DipolePCBCable I- pex (同等級) 50 x 10 x 0.4 mm 3 BT 2.4G DipolePCBCable I- pex (同等級) 35 x 10 x 0.4 mm 3 Confidential & Proprietary 10 Return Loss – Ant 0 n71B12B5 Freq. (MHz) 617663698699716746824849894 Return Loss (dB) -7.1-7.31-8.56-8.56-9.62-13.3-10.9-10.6-8.98 Confidential & Proprietary 11 Return Loss – Ant 1 n71B12B5 Freq. (MHz)617634652729737746869880894 Return Loss (dB)-7.5 -9.3 -8.6 -11.5 -9.7 -9.0 -9.1 -8.6 -7.9 B66B2/B25n41 Freq. (MHz)211021402170193019601990249626002690 Return Loss (dB)-8.4 -8.1 -8.2 -12.2 -11.7 -11.8 -11.4 -17.5 -15.4 Confidential & Proprietary 12 Return Loss – Ant 2 B66B2/B25n41n77 Freq. (MHz)171017802150185019101990249626002690330037004200 Return Loss (dB)-15.7 -14.4 -20.2 -14.2 -14.4 -16.6 -21.7 -24.3 -19.6 -17.4 -13.4 -10.0 Confidential & Proprietary 13 Return Loss – Ant 3 n71B12B5 Freq. (MHz)617634652729737746869880894 Return Loss (dB)-6.3 -6.7 -7.1 -9.8 -11.3 -11.3 -6.7 -6.3-6.0 B66B2/B25n41 Freq. (MHz)211021402170193019601990249626002690 Return Loss (dB)-17.6 -23.8 -26.5 -17.7 -17.6 -17.4 -17.2 -12.8 -13.4 Confidential & Proprietary 14 Return Loss – Ant 4 n71B12B5 Freq. (MHz)617634652729737746869880894 Return Loss (dB)-6.8 -7.2 -8.3 -11.8 -13.2 -12.0 -7.5 -7.3 -7.8 B66B2/B25n41n77 Freq. (MHz)171017802150185019101990249626002690330037004200 Return Loss (dB)-11.1 -12.1 -21.1 -13.4 -20.6 -22.8 -16.2 -15.3 -18.1 -22.1 -13.8 -9.7 Confidential & Proprietary 15 Return Loss – Ant 5 n77 Freq. (MHz)330037004200 Return Loss (dB)-10.1 -20.9 -11.8 Confidential & Proprietary 16 Return Loss – Ant 6 n77 Freq. (MHz)330037004200 Return Loss (dB)-10.9 -16.0 -16.6 Confidential & Proprietary 17 Return Loss – DA2 B66B2/B25n41n77 Freq. (MHz)171017802150185019101990249626002690330037004200 Return Loss (dB)-9.4 -8.9 -11.1 -9.5 -10.6 -12.2 -12.5 -12.5 -13.3 -7.0 -10.6 -18.1 Confidential & Proprietary 18 Return Loss – DA4 n71B12B5 Freq. (MHz)617634652729737746869880894 Return Loss (dB)-8.7 -10.2 -9.4 -23.3 -17.9 -13.0 -6.4 -6.2 -6.0 B66B2/B25n41n77 Freq. (MHz)171017802150185019101990249626002690330037004200 Return Loss (dB)-17.2 -19.6 -15.5 -22.9 -16.4 -13.4 -12.6 -15.0 -29.5 -8.0 -15.4 -13.3 Confidential & Proprietary 19 Return Loss – GPS GPS Freq. (MHz)157015751580 Return Loss (dB)-18.1 -18.1 -18.2 Confidential & Proprietary 20 Return Loss – WF0 2.4G5G Freq. (MHz)240024502500515055005850 Return Loss (dB)-18.4 -17.4 -22.3 -12.2 -24.9 -17.6 Confidential & Proprietary 21 Return Loss – WF1 2.4G5G Freq. (MHz)240024502500515055005850 Return Loss (dB)-11.1 -14.2 -10.9 -15.8 -13.5 -14.2 Confidential & Proprietary 22 Return Loss – WF2 2.4G5G Freq. (MHz)240024502500515055005850 Return Loss (dB)-22.7 -17.5 -14.3 -20.3 -20.3 -15.2 Con…
Text truncated - open the document above for the full version.
Report No.: RFBEIH-WTW-P22120620 Page No. 1 / 37 Report Format Version: 7.1.0 TEST REPORT CERTIFICATE OF CONFORMITY Standard: 47 CFR FCC Part 15, Subpart C (Section 15.247) Report No.: RFBEIH-WTW-P22120620 FCC ID: P27-TMOG4SE Product: T-Mobile 5G Gateway Brand: T-Mobile Model No.: TMO-G4SE Received Date: 2022/12/19 Test Date: 2023/1/30 ~ 2023/3/2 Issued Date: 2023/3/29 Applicant: Sercomm Corp. Address: 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location (1): No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan Test Location (2): B2F., No.215, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan FCC Registration / Designation Number: 788550 / TW0003 427177 / TW0011 Approved by: , Date: 2023/3/29 Jeremy Lin / Project Engineer This test report consists of 37 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Lena Wang / Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: RFBEIH-WTW-P22120620 Page No. 2 / 37 Report Format Version: 7.1.0 Table of Contents Release Control Record ....................................................................................................................................................... 4 1 Certificate .................................................................................................................................................................... 5 2 Summary of Test Results .......................................................................................................................................... 6 2.1 Measurement Uncertainty ........................................................................................................................................ 6 2.2 Supplementary Information ...................................................................................................................................... 6 3 General Information ................................................................................................................................................... 7 3.1 General Description .................................................................................................................................................. 7 3.2 Antenna Description of EUT ..................................................................................................................................... 7 3.3 Channel List .............................................................................................................................................................. 8 3.4 Test Mode Applicability and Tested Channel Detail .................................................................................................. 8 3.5 Duty Cycle of Test Signal.......................................................................................................................................... 9 3.6 Test Program Used and Operation Descriptions .................................................................................................... 10 3.7 Connection Diagram of EUT and Peripheral Devices ............................................................................................ 10 3.8 Configuration of Peripheral Devices and Cable Connections ................................................................................ 10 4 Test Instruments ...................................................................................................................................................... 11 4.1 RF Output Power .................................................................................................................................................... 11 4.2 Power Spectral Density .......................................................................................................................................... 11 4.3 6 dB Bandwidth ............................................…
Text truncated - open the document above for the full version.
Report No.: RFBEIH-WTW-P22120620-1 Page No. 1 / 78 Report Format Version: 7.1.0 TEST REPORT CERTIFICATE OF CONFO…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 992.00 mW |
WIRELESS PIR MOTION SENSOR
Equipment Class
DTS - Digital Transmission SystemMoso Canopy 5GOD2
Equipment Class
CBD - Citizens Band Category A and B DevicesCATM1 Module
Equipment Class
PCB - PCS Licensed TransmitterMqio 9W
Equipment Class
DTS - Digital Transmission SystemMachineQ Area 8C V2 LoRaWAN Gateway
Equipment Class
PCB - PCS Licensed Transmitter